Milan Hanajik
|
8a85458865
|
Minor DataStream.Reader and Elde.FlowMeter fixes
|
2021-08-18 13:06:37 +02:00 |
|
Milan Hanajik
|
848f9dff9d
|
Initial values: CalibDate = Constants.MinDate, CalibValidDate = Constants.MaxDate, MaxDate = new DateTime(2039, 12, 31);
|
2021-08-18 10:40:51 +02:00 |
|
Milan Hanajik
|
96abee384b
|
IParamsProvider : IList<strig> ParamValues( ) --> ICollection<string> ParamValues( )
|
2021-07-28 13:31:18 +02:00 |
|
Milan Hanajik
|
6f65f0085e
|
Milwaukee: TempCalibData = new float[16, 5], Diverters count bug fix, ver. 3.1.1688
|
2021-06-30 12:33:42 +02:00 |
|
Milan Hanajik
|
4f9b07ba20
|
RegulValve.SetFlowOp : RqrdFlowRangeRatio = 0.5, requiredFlowLo/HI -= Config.Formulas.GetCorrection(...), ver. 2.26.1679
|
2021-06-28 12:09:42 +02:00 |
|
Milan Hanajik
|
18880dc04d
|
Assignment of drain valves to scales and tanks fixed. ver. 2.26.1607
|
2021-04-12 12:00:23 +02:00 |
|
Milan Hanajik
|
b5572c20e3
|
Factories are without ResetStaticProperties( ).
|
2021-04-08 12:03:25 +02:00 |
|
Milan Hanajik
|
1d50b7206d
|
Components Initialize() rewritten, double StartChangeHandler() calls avoided, ToString() methods are equl, use ClassName.
|
2021-04-08 12:03:18 +02:00 |
|
Milan Hanajik
|
2e75d91adc
|
Bug fix in MetrologyDlgFlowMeterTab, etc. when ranges are enabled, ver. 2.26.1588
|
2021-02-08 10:12:12 +01:00 |
|
Milan Hanajik
|
66852682bf
|
Elde.RegulValveMilwaukee, Modbus.Novus added, Elde component updated (18.12.2020), ver. 2.26.1571
|
2021-01-15 14:15:15 +01:00 |
|
Milan Hanajik
|
2981ab2a5f
|
Milwaukee : ADC-s for diverters can be calibrated, ver. 2.26.1568
|
2021-01-05 14:06:15 +01:00 |
|
Milan Hanajik
|
0d8210614d
|
EtPulsesK and DivSamples() fixed for all Fuzhou test benches, ver. 2.26.1567
|
2021-01-05 09:45:34 +01:00 |
|
Milan Hanajik
|
99cd84fb2a
|
Changes for MILWAUKEE, component dated 16.12.2020, ver. 2.26.1561
|
2020-12-16 14:46:53 +01:00 |
|
Milan Hanajik
|
c72fb29f36
|
Constructors of components : Logging level increased to WARN.
|
2020-12-04 11:59:26 +01:00 |
|
Milan Hanajik
|
df1b4527ba
|
ValveCategory.All removed, cleanup, SequenceBase improvement.
|
2020-12-03 13:51:43 +01:00 |
|
Milan Hanajik
|
89b47860a5
|
WARSAW_50 symbol, Warsaw-50 component.
|
2020-12-02 09:34:09 +01:00 |
|
Milan Hanajik
|
1f581a72c1
|
Register readers cleanup, IRegReaderPulses added.
|
2020-11-06 14:33:32 +01:00 |
|
Milan Hanajik
|
f1d46782d3
|
Luxemburg component, LUXEMBURG_40 symbol incl. StatusP, TestMethods.DiverterTest fixed.
|
2020-11-06 14:33:23 +01:00 |
|
Milan Hanajik
|
95c7257d6f
|
Defined symbols in expressions are sorted.
|
2020-10-22 10:26:27 +02:00 |
|
Milan Hanajik
|
037a5be3b3
|
SyncRoute( ) called in RunDeviceBefore( ), this should fix FixedStartMassCollection.
|
2020-10-09 09:41:03 +02:00 |
|
Milan Hanajik
|
49d4cf1ac0
|
HONGKONG_50 symbol added, HongKong component added, ver. 2.26.1519
|
2020-09-09 09:58:58 +02:00 |
|
Milan Hanajik
|
450530a707
|
In FIxedStart methods there is a delay after start of a test before the flow regulation starts.
|
2020-08-07 12:14:04 +02:00 |
|
Milan Hanajik
|
adf30d615b
|
(1) MettlerToledo: Zero instead of Taring, (2) RegValveCalib array size fixed for ADC#8..11, ver. 2.26.1511
|
2020-08-07 11:11:44 +02:00 |
|
Milan Hanajik
|
114e628305
|
(1) Diverter.flowMtrNr4Cmd for SLM_150, (2) Config.Data cleanup
|
2020-08-05 09:36:00 +02:00 |
|
Milan Hanajik
|
5bb94666a4
|
(1) Diverter.nextIdx not incremented when DebugMode.Off, (2) VR1 accepts number entry, ver. 2.26.1499
|
2020-07-09 13:31:24 +02:00 |
|
Milan Hanajik
|
3cbc845183
|
Support for certificates, calib. expiration dates and calendar in many components and in TBF.UI.Bench.Metrology
|
2020-05-11 14:31:37 +02:00 |
|
Milan Hanajik
|
cafb59c9b0
|
Bug fix : Serving events from components, FlowMeter a BalanceDev calibration due date, ver. 2.26.1450
|
2020-04-21 13:34:18 +02:00 |
|
Milan Hanajik
|
b1d692230e
|
Events, EventViewer, Common prjs, UI.EventLogs, UI.Calendar, EventTriggers, GetCalendarEvents() in WT/I.
|
2020-04-21 10:46:42 +02:00 |
|
Milan Hanajik
|
f00196c4a8
|
(1) Adjustment.WMErrorsForm48, (2) MeretRS485Address = new byte[6] for IZRAEL_50
|
2020-03-31 11:28:42 +02:00 |
|
Milan Hanajik
|
dffaa1d3a8
|
Earlier mass measurement and tank draining in FlyingStartMassCollProlonged, ver. 2.25.1437
|
2020-03-10 15:39:39 +01:00 |
|
Milan Hanajik
|
7f56fa0aa3
|
Gelsenwasser : Flowmeter number with diverter info.
|
2020-03-06 08:21:24 +01:00 |
|
Milan Hanajik
|
bd15d3bd83
|
GEWLSENWASSER: symbol, component, RV.adcChannel and Div.flowMtrNr4Cmd, ROMA_200: route bit 80 fixed.
RegulValve.adcChannel and Diverter.flowMtrNr4Cmd for GELSENWASSER
|
2020-03-02 12:01:23 +01:00 |
|
Milan Hanajik
|
dc31e833ee
|
BatchResults.WaterMeters eliminated, Batch.WaterMeters are used instead ... many changes
|
2020-02-05 10:33:32 +01:00 |
|
Milan Hanajik
|
6ec2852581
|
DEWA PT300 : Bit 80 / VI11 issue fixed, ver. 2.25.1405
|
2020-01-27 14:21:00 +01:00 |
|
Milan Hanajik
|
2ad50a9708
|
Command.Stop enqueued after Emergency stop in similar way as before.
|
2020-01-21 17:40:31 +01:00 |
|
Milan Hanajik
|
b4763441a8
|
(1) Bug fix in sending FM pump frequencies to control board, (2) More logging, ver. 2.24.1386
|
2019-12-18 10:45:25 +01:00 |
|
Milan Hanajik
|
88a7de450a
|
Users cleanup, ver. 2.24.1382
|
2019-12-13 18:08:38 +01:00 |
|
Milan Hanajik
|
e9c6f58e0d
|
ALZIR_25 symbol and component added
|
2019-11-26 18:03:24 +01:00 |
|
Milan Hanajik
|
3e026d7129
|
Elde.RegisterReader.RegisterReader.Position, IRegisterReader.Position, etc. introduced., ver. 2.24.1365
|
2019-11-20 13:09:38 +01:00 |
|
Milan Hanajik
|
0297d74b17
|
ROMA_200 : (1) Component upgraded (12.11.2019), (2) Dummy scale does not overwrite Tank/DrainValve info, (3) minor changes, ver. 2.24.1363
|
2019-11-13 08:14:01 +01:00 |
|
Milan Hanajik
|
708610b8ab
|
ROMA_200 : Component added, symbol processing added, ver. 2.24.1359
|
2019-11-07 14:45:09 +01:00 |
|
Milan Hanajik
|
424be60a05
|
Bug fixes : (1) FlowMeterDewa, (2) ControlComWrap.ReferenceFreqs(int i)
|
2019-10-30 09:24:48 +01:00 |
|
Milan Hanajik
|
d5c0eb9c09
|
(1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified.
|
2019-10-24 12:57:37 +02:00 |
|
Milan Hanajik
|
dbe87a375d
|
TransitionContext.AfterTestWithOverlap, PID coef. set earlier as well, nextHydroTest in MainSeq.
|
2019-10-24 12:56:59 +02:00 |
|
Milan Hanajik
|
2aa8b19c87
|
FlowMeter, FlowmeterTriplet : Condiiton (flow < 0.1 * NominalFlow) removed from LtrPerPulseCorrected( )
|
2019-09-26 15:39:19 +02:00 |
|
Milan Hanajik
|
9caae8dffd
|
(1) FlowMeteDewa uses EtPulses2, EtPulses3, (2) WMChart fixed, Q4 displayed, (3) Minor MainSeq bug fix.
|
2019-09-22 16:37:58 +02:00 |
|
Milan Hanajik
|
3333b4baa2
|
FlowMeterDewa bug fix, wrong indices used when calculating a correction of a sum of flows.
|
2019-09-19 07:45:21 +02:00 |
|
Milan Hanajik
|
994568799d
|
Refactorization: TBF.UI namespace, no change of function, ver. 2.18.1314
|
2019-09-17 10:58:44 +02:00 |
|
Milan Hanajik
|
d4eb52d70e
|
RegulValve.SetFlowOp in progress
|
2019-09-12 13:50:53 +02:00 |
|
Milan Hanajik
|
6079c8419f
|
(1) Diverter switch time measurement modifications (2) const int CountWhenSendingRdDivCmd = 1, CountWhenReadingDiv = 3.
|
2019-09-04 15:08:36 +02:00 |
|