Milan Hanajik
7e8dfd472d
Zapne pumpu pred vypustanim
2015-02-01 18:53:09 +01:00
Milan Hanajik
6dbff5978a
Pokus
2015-02-01 17:14:50 +01:00
Milan Hanajik
806f4efe6a
Results printing and saving uses Publish property of GenericDevices.ITestMethod
2015-02-01 16:20:27 +01:00
Milan Hanajik
efa14c6ebb
Adjustment results will not be printed, shown, etc.
2015-02-01 08:20:13 +01:00
Milan Hanajik
0c4da37e85
Adjustment: Graphics added, to be tested
2015-01-28 22:14:30 +01:00
Milan Hanajik
5653628bf7
Adjust: Larger font, place for graphics
2015-01-28 20:57:03 +01:00
Milan Hanajik
94accbf58b
Bugfix: Adjustment method modeless dialog was not started in UI thread, freezes
2015-01-28 19:33:02 +01:00
Milan Hanajik
508f47cb6b
Adjustment test method ready for tests
2015-01-28 18:18:46 +01:00
Milan Hanajik
85bb34030a
Bugfix in Fixed start method when configuration is NOK, no Dummy RR-s
...
Bugfix in FIxed start method Entry form when config.is NOK, WM-s are missing
2015-01-27 23:00:42 +01:00
Milan Hanajik
5cf5fe5eba
CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change)
2015-01-25 08:11:40 +01:00
Milan Hanajik
ad665e5f0b
Combined meters measurement corrections, Q_rise and Q_fall in results
2015-01-17 08:57:50 +01:00
Milan Hanajik
d3532a2796
PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
...
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
bb31cdae56
Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results
2015-01-15 06:34:36 +01:00
Milan Hanajik
9c1db2778e
Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page
2015-01-15 03:16:14 +01:00
Milan Hanajik
1c3c90e171
CombinedMeters and CombinedWithDetection support SupressTrils bool parameter
...
Warnings 'Unreachable code' supressed in DataEntries
2015-01-14 05:33:51 +01:00
Milan Hanajik
5a4df5593a
(1) Passed/Failed with color in the on-screen results
...
(2) Error of main and aux. combined watermeters calculated and can be used in results
(3) Bugfix: no zero reference exception when the list of results items is empty
2015-01-14 03:19:12 +01:00
Milan Hanajik
34dc592e59
Timeout while setting the water flow handled correctly: message displayed, test aborted
2015-01-12 05:56:19 +01:00
Milan Hanajik
b79ae4b1aa
PumpTandem component added (to be completed), fixes in component config edit controls
2015-01-11 05:06:18 +01:00
Milan Hanajik
de90a4638a
Prepared: PID coefficient of the output path is ready to be used,
...
and not the regul.valve parameter. See // TODO PID: ... in source code.
Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
0160dc965d
- RegulValve ADC Open/Close values calibration implemented
...
- 'More' button added to ComponentCfgCtrl-s
- Dataflow from ComponentParametersDlg to components: CfgChangeHandler
- Dataflow from components to ComponentParametersDlg: CmdResponseHandler
- Detection of parameter changes and appropriate MesssageBox display:
1.warning message when component configuration change requires program restart
2.confirmation message box when any configuration changes would be lost
2015-01-03 14:45:58 +01:00
Milan Hanajik
f2005bbf56
Boilerplate code reduced from factories, GetComponent() and GetControl() added to cfg-s
2015-01-02 19:14:19 +01:00
Milan Hanajik
94de991bf6
Everything works OK after serious changes:
...
- all components, componentCfg-s and parameter providers use base classes
- less boilerplate code, simpler access to test/procedure parameters from code
- CreateTestParams(test), CreateProcedureParams(procedure) methods added
- TestBenchSim class is made static, it is not inheritted by any device anymore
2015-01-02 12:51:27 +01:00
Milan Hanajik
752719bd62
Getting rid of and suppressing WARNING messages
2014-12-31 13:44:47 +01:00
Milan Hanajik
0ac7ba05d6
Methods CreateDbEntity and CreateFromDbEntity moved from XyzCfg to ComponentCfgBase, factories modified accordingly.
2014-12-29 18:33:27 +01:00
Milan Hanajik
6d6b322fb5
Process screen and Procedure (dlg, DB) changes to suport combined meters, virtual bench.
...
TODO: Visualize changes of pump/valve, diverter, tank
2014-12-12 12:13:43 +01:00
Milan Hanajik
1afd6870c3
Time2MassMsrmt implemented, database tables Test and TestResult changed
2014-12-11 08:49:07 +01:00
Milan Hanajik
54595c9ebd
ROI detection handled separately from (fatal) camera errors
2014-10-13 17:54:15 +02:00
Milan Hanajik
930db8c379
- many process tab page improvements
...
- program start and state changes logging improved
- IDC100 measurement related changes: reference pulses in RegisterReader
- etc
2014-10-02 20:56:24 +02:00
Milan Hanajik
b6bbad66e7
IDC Camera related fixes - to be tested
2014-10-02 18:05:54 +02:00
Milan Hanajik
deb6b90332
VirtualBenchSequences UI completed, delete step is not OK yet
2014-09-28 22:23:41 +02:00
Milan Hanajik
1c34946a6b
Bugs in sequences fixed: Missing CheckUiOp
2014-09-26 17:48:55 +02:00
Milan Hanajik
9868c41640
Zmeny urobene v ST pri testovani kamery
2014-09-24 19:58:05 +02:00
Milan Hanajik
2f6f24e281
As sent to ST for the last test on Fuzhou300 system
...
- new component with VZ15 and modified position of VZ13
- fixed start method evaluation OK
- handling of entry forms cleaned-up
2014-09-23 13:16:59 +02:00
Milan Hanajik
b1f7730b96
- FixedStartMassCollection method ready to be tested
...
- FlyingStart method (without mass collection) flow corrections fixed
- DataEntry/WMStates data entry forms added (used by FixedStartMassCollection method)
- minor changes
2014-09-16 21:05:54 +02:00
Milan Hanajik
54ef1e1216
- added BenchControl/Operations/ProcessDataLoggingOp.cs (forgotten in previous commits)
...
- fixed a bug in displayng results and progress controls when two tests had the same name
- some work on data entry forms for FixedStartMassCollection method - not finished yet
2014-09-16 16:09:07 +02:00
Milan Hanajik
a79be1e07a
- bug fixed when component (class) in the DB does not exist in the code
...
- preparing FixedStartMassCollection sequence
2014-09-16 12:04:08 +02:00
Milan Hanajik
c187dc9abf
- FlyingStart with corrections
...
- FlowMeterCouple -> FlowMeterTwins
2014-09-15 22:00:37 +02:00
Milan Hanajik
a919a3e9d6
- FLyngStart sequence (without balances) tested -> OK, Todo: use
...
corrections
- totalPulses calculated correctly in case of I11+I12 (use of two flowmeters)
2014-09-12 07:18:24 +02:00
Milan Hanajik
3559ab0ab3
- Elde.FlowMeterCouple component added
...
- LtrPerPulse and LtrPerPulseCorrected property/function added to IFlowMeter and flowmeters
2014-09-10 13:43:33 +02:00
Milan Hanajik
fcfdfeca41
- COmponent properties 'Position' --> 'Idx0' or 'Idx1'
...
- process data logging, RegulVal position logging
- changes for I11+I12, NOK yet
2014-09-10 12:05:49 +02:00
Milan Hanajik
d0ebb62ab3
- Component update (temp.)
...
- Process data logging, first trial
2014-09-09 16:18:23 +02:00
Milan Hanajik
354c13853f
All PumpsWithFM are controlled when opening pumps at the test start
2014-09-09 09:14:47 +02:00
Milan Hanajik
d14cb175a6
FlowStableSec parameter added to RegulValve
2014-09-08 20:24:46 +02:00
Milan Hanajik
6eee83042b
PmpWithFM and Transition sequences functionality implemented
2014-09-08 13:16:31 +02:00
Milan Hanajik
99377ce3b9
Size and location of some dialogs saved: Components, Paths, Transitions, Metrology, Procedures, Procedure
2014-09-07 09:34:28 +02:00
Milan Hanajik
b8faca784e
- ReferenceFlowmeterCalibration method and sequence (ready for tests)
...
- FlyingStart method and sequence files prepared for implementation (copies of FlyingStartMassCollection)
2014-09-06 17:34:26 +02:00
Milan Hanajik
f01a0d84fe
Folder with files for FixedStartMassCollection (copy of FlyingStart..) added to project, builds OK
2014-09-05 09:06:23 +02:00
Milan Hanajik
ea59dd0932
FlyingStart...Seq and CombinedMetersSeq sequences cleaned-up:
...
- Stop should work OK
- Target flow is tested and config error is shown in case it's NOK
- TestEnd sequence executed on Error
2014-08-15 14:32:03 +02:00
Milan Hanajik
596667a67e
Default action and stopping the FM-controlled pump
...
moved to SequenceBase.Transition(sequence, context).
Sequences cleaned-up.
2014-08-14 09:06:01 +02:00
Milan Hanajik
e128784bb8
Sequences cleaned-up
2014-08-13 16:20:00 +02:00