Milan Hanajik
7e8dfd472d
Zapne pumpu pred vypustanim
2015-02-01 18:53:09 +01:00
Milan Hanajik
6dbff5978a
Pokus
2015-02-01 17:14:50 +01:00
Milan Hanajik
806f4efe6a
Results printing and saving uses Publish property of GenericDevices.ITestMethod
2015-02-01 16:20:27 +01:00
Milan Hanajik
0238a96975
More comments in SetFlowOp
2015-02-01 15:07:15 +01:00
Milan Hanajik
ae5abde1e6
Results printing and saving improced, correct order of tests, etc.
2015-02-01 13:43:04 +01:00
Milan Hanajik
8009774c20
Bugfixes: FM pumps % interpretation after adding a pump, Tabs order in entry forms
2015-02-01 11:04:05 +01:00
Milan Hanajik
efa14c6ebb
Adjustment results will not be printed, shown, etc.
2015-02-01 08:20:13 +01:00
Milan Hanajik
0c4da37e85
Adjustment: Graphics added, to be tested
2015-01-28 22:14:30 +01:00
Milan Hanajik
5653628bf7
Adjust: Larger font, place for graphics
2015-01-28 20:57:03 +01:00
Milan Hanajik
94accbf58b
Bugfix: Adjustment method modeless dialog was not started in UI thread, freezes
2015-01-28 19:33:02 +01:00
Milan Hanajik
cca60e56ff
Yet one more change - adjust
2015-01-28 19:03:00 +01:00
Milan Hanajik
508f47cb6b
Adjustment test method ready for tests
2015-01-28 18:18:46 +01:00
Milan Hanajik
6a3e3e7682
Layout changes, c:/TBF/header.png used
2015-01-28 07:24:03 +01:00
Milan Hanajik
545cce6d11
Printed and Saved basic results output improved
2015-01-27 23:02:34 +01:00
Milan Hanajik
85bb34030a
Bugfix in Fixed start method when configuration is NOK, no Dummy RR-s
...
Bugfix in FIxed start method Entry form when config.is NOK, WM-s are missing
2015-01-27 23:00:42 +01:00
Milan Hanajik
0b7c6a0fed
First version of Basic printing (one page only)
2015-01-27 02:37:24 +01:00
Milan Hanajik
8aa9ed9f21
Bugfix for PT200IL: Test does not complete, Status bits definition changed
2015-01-26 13:15:47 +01:00
Milan Hanajik
c3f64215f1
ProtocolTitle added to 'Procedure' and 'TestResult'. ResultsWriter-Basic rewritten
2015-01-25 23:43:17 +01:00
Milan Hanajik
5cf5fe5eba
CycleNr added to LocalSettings, Entities.TestResults, Mappings, is used in sequences (DB change)
2015-01-25 08:11:40 +01:00
Milan Hanajik
ad665e5f0b
Combined meters measurement corrections, Q_rise and Q_fall in results
2015-01-17 08:57:50 +01:00
Milan Hanajik
d3532a2796
PumpFM,pumpTandem test parameter Power replaced by parameter Entities.Test.PumpPower,
...
all changes done except of UI changes (which can be done in more different ways)
2015-01-17 04:52:42 +01:00
Milan Hanajik
a0fb8000f0
PumpTandem can also be used as one of pumps in the tandem, PumpTandems can be chained
2015-01-16 07:40:04 +01:00
Milan Hanajik
b1c9e0d3b5
Bugfixes: (1) PumpTandem was missing a Mask to be used as Valve, (2) Column widths in results screen
2015-01-16 07:08:26 +01:00
Milan Hanajik
e07cf3c5d3
PumpTandem implemented for the case of two FM pumps with equal distribution of power
2015-01-16 05:24:34 +01:00
Milan Hanajik
2b6b569dee
Process log format changes: flow with 4 valid digits, Et. -> Ref.
2015-01-16 03:09:39 +01:00
Milan Hanajik
5a2d7f09ce
CycleBeginForm is opened earlier, immediately after procedure selection, before purging
2015-01-16 03:09:37 +01:00
Milan Hanajik
bb31cdae56
Make sure CycleBeginForm is closed before the 1st test ends and s/n is in all results
2015-01-15 06:34:36 +01:00
Milan Hanajik
11bdb1b2f1
Bugfix in MainSeq (opening EntryForm instead of closing)
2015-01-15 05:03:46 +01:00
Milan Hanajik
49a004d7fe
DataEntry dlg at the beginning closes at the end of the 1st test (at the latest)
2015-01-15 03:51:33 +01:00
Milan Hanajik
9c1db2778e
Data of all combined meters are used in TestProgressEventArgs, in sequences and the process page
2015-01-15 03:16:14 +01:00
Milan Hanajik
1c3c90e171
CombinedMeters and CombinedWithDetection support SupressTrils bool parameter
...
Warnings 'Unreachable code' supressed in DataEntries
2015-01-14 05:33:51 +01:00
Milan Hanajik
5a4df5593a
(1) Passed/Failed with color in the on-screen results
...
(2) Error of main and aux. combined watermeters calculated and can be used in results
(3) Bugfix: no zero reference exception when the list of results items is empty
2015-01-14 03:19:12 +01:00
Milan Hanajik
00b937553c
Localization via strings table added to DataEntry.Munich3 (accepts 6 single WM-s)
2015-01-13 09:12:40 +01:00
Milan Hanajik
1f489a481c
Entry form DataEntry.Munich modified so that it accepts up to 3 combined WM-s
2015-01-13 08:46:32 +01:00
Milan Hanajik
de7a04d689
Bug fix in UI: Process -> Metrology1 -> Emptying
2015-01-12 07:43:54 +01:00
Milan Hanajik
34dc592e59
Timeout while setting the water flow handled correctly: message displayed, test aborted
2015-01-12 05:56:19 +01:00
Milan Hanajik
0829655880
Messages and Errors display is supported, transition messages are displayed now
2015-01-12 04:53:50 +01:00
Milan Hanajik
d1cb0a4f43
Fixed problem: FM Pump is switched off when setting the flow, more logging
2015-01-11 08:24:05 +01:00
Milan Hanajik
b79ae4b1aa
PumpTandem component added (to be completed), fixes in component config edit controls
2015-01-11 05:06:18 +01:00
Milan Hanajik
11f8343a1d
Bug fix in purging sequence when no RV-s
2015-01-08 08:05:23 +01:00
Milan Hanajik
b8fb6ba12c
Fuzhou150 component updated, contains MakeExtComm()
2015-01-07 15:56:57 +01:00
Milan Hanajik
a86ad864e1
Reconfigured for Fuzhou150, missing an upgraded component
2015-01-07 10:11:29 +01:00
Milan Hanajik
9fb462b087
Bug fix Null reference exception when starting a test
2015-01-07 10:11:29 +01:00
Milan Hanajik
580d4330e3
- PidCoef from OutputPath used in flow control, PidCoef regulValve parameter abandoned
...
- Part field (int) added to Test and TestResult, shown and processed in UI in ProcedureDlg
2015-01-04 23:21:12 +01:00
Milan Hanajik
035416b785
Bug fix: Null reference exception when closing a modified procedure
2015-01-04 16:26:54 +01:00
Milan Hanajik
de90a4638a
Prepared: PID coefficient of the output path is ready to be used,
...
and not the regul.valve parameter. See // TODO PID: ... in source code.
Database: 'PidCoef' float should be added to 'OutputPath' after col.'FlowMeter'
2015-01-03 21:17:11 +01:00
Milan Hanajik
0160dc965d
- RegulValve ADC Open/Close values calibration implemented
...
- 'More' button added to ComponentCfgCtrl-s
- Dataflow from ComponentParametersDlg to components: CfgChangeHandler
- Dataflow from components to ComponentParametersDlg: CmdResponseHandler
- Detection of parameter changes and appropriate MesssageBox display:
1.warning message when component configuration change requires program restart
2.confirmation message box when any configuration changes would be lost
2015-01-03 14:45:58 +01:00
Milan Hanajik
f2005bbf56
Boilerplate code reduced from factories, GetComponent() and GetControl() added to cfg-s
2015-01-02 19:14:19 +01:00
Milan Hanajik
94de991bf6
Everything works OK after serious changes:
...
- all components, componentCfg-s and parameter providers use base classes
- less boilerplate code, simpler access to test/procedure parameters from code
- CreateTestParams(test), CreateProcedureParams(procedure) methods added
- TestBenchSim class is made static, it is not inheritted by any device anymore
2015-01-02 12:51:27 +01:00
Milan Hanajik
752719bd62
Getting rid of and suppressing WARNING messages
2014-12-31 13:44:47 +01:00