Commit Graph
21 Commits
Author SHA1 Message Date
Milan Hanajik c950cc231c ParamValues() retval IList->ICollection, GetControl() arg. is a list of components, ver. 3.1.1598 2021-03-02 01:10:04 +01:00
Milan Hanajik 4cf4192ebb BenchControl.Uni.Diverter/FlowMeter/RegReader added, etc. (many changes and refactorization). 2021-02-24 14:15:10 +01:00
Milan Hanajik 63a15fc1de Constructors of components : Logging level increased to WARN 2021-02-19 09:50:48 +01:00
Milan Hanajik 5a1d77dd87 Bug fix in MetrologyDlgFlowMeterTab, etc. when ranges are enabled 2021-02-08 10:09:02 +01:00
Milan Hanajik 1f67899a5c Schematic drawing with live function, bench control by mouse, Dijkstra algo, vacuum, etc. 2020-06-14 13:01:53 +02:00
Milan Hanajik 070a76aade SchematicDrawing: Editing completed, TODO: Display 2020-06-02 12:00:45 +02:00
Milan Hanajik 7b321abb30 ControlBoards, IControlBoard iface, Devices, test methods. 2020-05-21 15:55:02 +02:00
Milan Hanajik 3cbc845183 Support for certificates, calib. expiration dates and calendar in many components and in TBF.UI.Bench.Metrology 2020-05-11 14:31:37 +02:00
Milan Hanajik cafb59c9b0 Bug fix : Serving events from components, FlowMeter a BalanceDev calibration due date, ver. 2.26.1450 2020-04-21 13:34:18 +02:00
Milan Hanajik b1d692230e Events, EventViewer, Common prjs, UI.EventLogs, UI.Calendar, EventTriggers, GetCalendarEvents() in WT/I. 2020-04-21 10:46:42 +02:00
Milan Hanajik 2aa8b19c87 FlowMeter, FlowmeterTriplet : Condiiton (flow < 0.1 * NominalFlow) removed from LtrPerPulseCorrected( ) 2019-09-26 15:39:19 +02:00
Milan Hanajik 994568799d Refactorization: TBF.UI namespace, no change of function, ver. 2.18.1314 2019-09-17 10:58:44 +02:00
Milan Hanajik d51edbfbfe Elde.FlowMeterDewa : (1) Exact LtrPerPulseCorrected calc. (2) nominal flow and flowmeters bitfield (=Idx0) calculated from particular flowmeters. 2019-05-12 08:17:52 +02:00
Milan Hanajik 556290abf6 DEWA300 double and tripple flowmeters, NominalFlow and LtrPerPulse are doubles, ver. 2.18.1191 2019-04-11 15:39:46 +02:00
Milan Hanajik d45c3f96d6 TBF : (1) flow setting timeout = 300 s = 5 min., (2) stable mass msrmnt. timeout = 300 s = 5 min., ver. 2.18.1162 2019-03-11 08:36:02 +01:00
Milan Hanajik 872409870e MetrologyDlgLevelMeterTab added. 2018-11-13 09:42:23 +01:00
Milan Hanajik cdc971f733 public enum CfgUpdateFlags moved to Config.Enums 2018-06-18 14:44:52 +02:00
Milan Hanajik 863856d27d ComponentCfgBase and derived classes : portected XmlSerializer GetSerializer() --> public XmlSerializer GetSerializer(). 2018-06-18 12:44:37 +02:00
Milan Hanajik e88175b349 (1) Output.DB.SaveFlowmeterCorrections: date, validity, certificate, (2) Flow_ctv, Flow_ctv_min, ... 2018-04-25 12:49:07 +02:00
Milan Hanajik 0993716c8e (1) TBF.BenchControl.Formulas --> Config.Formulas, (2) MeterTestRslt.RegReaderType, (3) Rslt.items added, (4) Quantity.Pulses, ver. 2.18.870 2018-04-11 11:11:45 +02:00
Milan Hanajik 0d3ee53bd5 Refactoring : TestBenchFramework --> TBF ver. 2.18.789 2018-01-29 09:48:01 +01:00