Commit Graph

83 Commits

Author SHA1 Message Date
Milan Hanajik
71613cba5d Q_ref_mean and many other result items added. 2017-05-19 11:25:24 +02:00
Milan Hanajik
6cace280c9 SequenceBase.LogProcessDataHeader() added. 2017-05-10 13:54:38 +02:00
Milan Hanajik
847a4d74d6 UpdateTempPressDensAmb(tstRslt) function added to SequenceBase, used by all sequences. 2017-05-10 10:43:33 +02:00
Milan Hanajik
ed83ae57c5 Progress bars are not displayed as 'completed' when a test was aborted. 2017-05-05 12:46:37 +02:00
Milan Hanajik
17c685148e (1) Flow selection in New Test Wizard extended, (2) MainSeq and BencControlPael modified, etc. 2017-05-03 22:24:25 +02:00
Milan Hanajik
fa57c51786 ProcedureParams initialization/constructors modified. ProcedureParamsBase modified. 2017-05-01 16:03:45 +02:00
Milan Hanajik
59392d8bdc MakeSimulated fixed when there are multiple test repetitions, ver. 2.12.555 2017-05-01 10:28:43 +02:00
Milan Hanajik
eafcf016f3 Setting regulation valves before flow setting disabled, caused porbles all the time, ver. 2.12 549 2017-04-24 11:58:57 +02:00
Milan Hanajik
05982cc2ff Endurance test method sequence modified. 2017-04-24 09:44:11 +02:00
Milan Hanajik
d372a38e7d Camera time read with each sample, calculation : VolumeStart, VolumeEnd, TimestampStart, TimestampEnd used, ver. 2.12.530 2017-04-07 11:29:35 +02:00
Milan Hanajik
44735260ce CLP1611 Measurement done only on successfully detected ROI-s, ver. 2.12.530 2017-04-06 23:47:24 +02:00
Milan Hanajik
464dfc6dd1 FlyingStartMassCollection : 'Next' button can be used to stop the test. 2017-04-05 22:01:21 +02:00
Milan Hanajik
049bbc8655 DEWA Q2 correction modified, Results.Entities.WaterMeter columns added (iPerl only). 2017-03-31 14:17:18 +02:00
Milan Hanajik
5f2da63339 Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519 2017-03-29 09:22:39 +02:00
Milan Hanajik
d420128b4b Draining modified, in BERLIN done always before flow setting, ver. 2.12.518 2017-03-28 23:54:52 +02:00
Milan Hanajik
3c4fe34c1d Test_volume_exceeds_the_scale_capacity situation handled correctly, no Error state. 2017-03-27 14:08:53 +02:00
Milan Hanajik
8d4af6f347 Bug in iPerl IRegisterReader usage by FlyingStartMassCollectionSeq fixed, ver. 2.12.501 2017-03-20 17:44:28 +01:00
Milan Hanajik
87bc0131cf Tests when test volume exceeds the tank capacity cannot be executed, an error message appears. 2017-03-10 13:10:57 +01:00
Milan Hanajik
4515f0fc13 FlyingStartMassCollectionSeq modified : Valves/pumps are closed immediately after the test only when there are no subsequent test repeats. 2017-02-21 10:45:26 +01:00
Milan Hanajik
970fc886c6 FlyingStartMassCollectionSeq : If transitionAfter is not used, the valves/pumps are closed immediately after the test before the 2nd mass measurement, ver. 2.12.472 2017-02-17 10:51:30 +01:00
Milan Hanajik
8d4910fcb0 Symbols: introduced IPERL, ORACLE_DB, HEAT_METERS, TURA_IPERL, TURA_SPECIAL
abandoned IPERLST, IPERLSTSPECIAL, HEAT_METERS_SUPPORT
2017-02-14 13:42:22 +01:00
Milan Hanajik
38c199f6f9 Interfaces between Camera and Roi and sequences finalized, TODO: network communication, ver. 2.12.446
Sequences more robust for debugging, T and Pr-meters checked for null
2017-01-25 17:28:57 +01:00
Milan Hanajik
044e53f2b2 Changes under construction : ROI registration to Cameras, ver. 2.12.441 2017-01-24 12:34:52 +01:00
Milan Hanajik
2150ced11f Propagation of ROI parameters between ROI-s and Cameras implemented, ver. 2.12.438 2017-01-22 20:40:12 +01:00
Milan Hanajik
6d45b2c878 RoiDetectionSeq modified, ready to be tested. 2017-01-16 15:51:34 +01:00
Milan Hanajik
c73cf7002f Camera.Roi.MeasurementOp added, UDP listener added, PulsesPerLtr (and ProcedureParams) added, etc. 2017-01-16 13:49:29 +01:00
Milan Hanajik
89901c75f7 Revert "Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow."
This reverts commit be52e2df96.
2016-12-16 13:07:54 +01:00
Milan Hanajik
be52e2df96 Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow. 2016-12-12 16:43:04 +01:00
Milan Hanajik
216e08d57c Execute(...) arguments changed everywhere, repetitionNr usage depends on outerLoopMode, outerLoopCounter, ver. 2.12.412 2016-12-10 13:03:35 +01:00
Milan Hanajik
f3b178473c Outer loop logic added, TODO: (1) Begin-block and End-block test methods, (2) support in test method sequences 2016-12-10 11:33:31 +01:00
Milan Hanajik
6df36659ab Dummy.Balance component added 2016-12-09 12:13:59 +01:00
Milan Hanajik
98a773700e Bug fix related to PressMtrDelta, ver. 2.12.386 2016-11-17 08:48:52 +01:00
Milan Hanajik
bab677c5c2 PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373 2016-10-18 19:14:01 +02:00
Milan Hanajik
d1fb0e0f0a T warm/cold lo/hi renamed to T hi/lo min/max 2016-10-18 17:27:24 +02:00
Milan Hanajik
03c027ab33 LogProcessDataHeatMeters, ver. 2.11.371 2016-10-18 11:49:32 +02:00
Milan Hanajik
0fb3a74879 Feeding regulation valves functionality implemented, ver. 2.11.367 2016-10-13 16:08:29 +02:00
Milan Hanajik
45e0f50562 Elde.RegulValve supports 'ReTryCommands' parameter (default = false), ver. 2.11.365 2016-10-13 16:08:15 +02:00
Milan Hanajik
dddfc4bed5 Bug-fixes in FlyingStart and FlyingStartMassCollection heat meters, T ref warm and T ref cold statistics, ver. 2.10.362 2016-10-12 01:23:38 +02:00
Milan Hanajik
b3a2c3a0fc FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360 2016-10-11 12:53:17 +02:00
Milan Hanajik
c84fd8089a FlyingStart and FlyingStartMassCollection methods: 'Begin cycle' dialog closed before 'Heat meters prompt message' is displayed. 2016-10-11 09:10:33 +02:00
Milan Hanajik
5f21b5ab26 ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods. 2016-10-10 14:35:59 +02:00
Milan Hanajik
f8331c1c1c Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359 2016-10-10 14:23:20 +02:00
Milan Hanajik
3c15dbab9e Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358 2016-10-10 11:35:45 +02:00
Milan Hanajik
438028506e Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow) 2016-10-07 16:22:36 +02:00
Milan Hanajik
010afcd1e4 Temperatures are internally stored and processed in double variables (except of ambient temp.). 2016-10-07 15:41:27 +02:00
Milan Hanajik
7df9333fba Statistics return doubles instead of float, casting is done just when writing to entities. 2016-10-07 14:46:14 +02:00
Milan Hanajik
4160420844 Masses are stored in double variables everywhere. 2016-10-07 14:06:54 +02:00
Milan Hanajik
c30f905893 SLM50 : Bugfix in energy calculation in FlyingStart and FlyingStartMassCollection methods, ver. 2.10.356 2016-10-07 10:09:38 +02:00
Milan Hanajik
c497c02ef9 Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352 2016-10-06 10:11:13 +02:00
Milan Hanajik
c842c50361 Heat meters evaluation added to FlyingStartMassCollectionSeq and FlyingStartSeq, ver. 2.10.345 2016-08-24 18:30:00 +02:00