Milan Hanajik
3c15dbab9e
Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358
2016-10-10 11:35:45 +02:00
Milan Hanajik
438028506e
Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow)
2016-10-07 16:22:36 +02:00
Milan Hanajik
010afcd1e4
Temperatures are internally stored and processed in double variables (except of ambient temp.).
2016-10-07 15:41:27 +02:00
Milan Hanajik
7df9333fba
Statistics return doubles instead of float, casting is done just when writing to entities.
2016-10-07 14:46:14 +02:00
Milan Hanajik
4160420844
Masses are stored in double variables everywhere.
2016-10-07 14:06:54 +02:00
Milan Hanajik
c30f905893
SLM50 : Bugfix in energy calculation in FlyingStart and FlyingStartMassCollection methods, ver. 2.10.356
2016-10-07 10:09:38 +02:00
Milan Hanajik
c497c02ef9
Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352
2016-10-06 10:11:13 +02:00
Milan Hanajik
2286877fad
Test method names cleaned up.
2016-09-26 11:08:16 +02:00
Milan Hanajik
c842c50361
Heat meters evaluation added to FlyingStartMassCollectionSeq and FlyingStartSeq, ver. 2.10.345
2016-08-24 18:30:00 +02:00
Milan Hanajik
e484697f60
Heat meters reference temperature measurement during Data entry form before the test starts.
2016-08-24 15:46:39 +02:00
Milan Hanajik
618f0b1bca
Modification of sequences to use ProcessData.TempRefWarm(Cold)1(2) and ReadTempOp operations, ver. 2.10.343
2016-08-23 15:21:33 +02:00
Milan Hanajik
0f7790e538
Prompt message box at the beginning of each heat meters test.
2016-08-22 16:00:48 +02:00
Milan Hanajik
9c0430a0d8
Adjustment component class name changed to TestMethods.Adjustment.Single
2016-08-22 15:59:37 +02:00
Milan Hanajik
df7631eb3a
Units of energy can be selected in DataEntry.HeatMeters12.TestStartEndForm.
2016-08-22 13:55:28 +02:00
Milan Hanajik
d8bb450a2e
VolumeForEnergy calculated in [l], ver. 2.10.341
2016-08-22 09:58:27 +02:00
Milan Hanajik
774d47a86f
More changes and fixes for heat measurement.
2016-08-21 22:07:20 +02:00
Milan Hanajik
e3318179c1
More changes for heat meters testing, DataEntry form completed.
2016-08-19 17:19:09 +02:00
Milan Hanajik
53ead401d0
FixedStartMassCollection : Changes for heat metetrs
2016-08-19 15:37:16 +02:00
Milan Hanajik
0426d2510a
Energy and RefEnergy added to ResultsDB, First/Last/Min/Max of all three ambient values added to TestRslt, ver. 2.10.340
2016-08-19 15:37:00 +02:00
Milan Hanajik
83ddb7c8bf
Waiting loop for temperature stability check in heat meters tests.
2016-08-17 18:11:34 +02:00
Milan Hanajik
011219d491
Heat meters test parameters updated.
2016-08-17 16:32:07 +02:00
Milan Hanajik
d4b20876b2
All FixedStart, FlyingStart and FlyingStartMassCollection methods reorganised, common sequences used, ver. 2.9.337
2016-08-17 15:38:09 +02:00
Milan Hanajik
0859dd28d5
PMAxTest, LeakTest, pressure in bar internally, ver. 2.9.335
2016-08-16 08:32:55 +02:00
Milan Hanajik
f7a7987831
Configs.NameOnly.TestMethodCfg[Ctrl] introduced and reused by Adjustment, FixedStartAdvanced, ...
...
... FixedStartCombinedMeters, FixedStartMassCollection, FlyingStart, FlyingStartMassCollection, ReferenceFlowMeterCalibration.
2016-08-15 10:14:14 +02:00
Milan Hanajik
8dae45e10e
IComponentCfg and IComponentFactory interfaces and all derived classes modified.
2016-08-05 14:32:36 +02:00
Milan Hanajik
e5ad1ac93b
HeatMeters test method, ver.2.9.333
2016-08-04 15:46:17 +02:00
Milan Hanajik
111e3d8647
Minimum and maximum (reference) flow during a test calculated and saved to Results.Entities.TestRslt.
2016-08-02 14:48:18 +02:00
Milan Hanajik
c88ac1fcab
Pressure up and Pressure down stored in mbar, not in kPa. Display in process data screens fixed.
2016-08-02 10:47:51 +02:00
Milan Hanajik
fa2896d755
Enthalpy calculation (1st ver.), heat meters path modifications (incl. UI)
2016-07-07 16:02:57 +02:00
Milan Hanajik
0ac1fe2b4e
HeatMetersPath, UI, etc., HEAT_METERS_SUPPORT symbol introduced
...
ProcedureDlg modifications: (1) localization by TBF.Resources.Strings, (2) Heat meters support
FlyingStartMassCollection and CombinedMeters methods with similar sequences
2016-07-06 15:59:28 +02:00
Milan Hanajik
ac1bdbe476
Bug fix: Updating water meter results in case of a test with parts, copes also with single meters/multiple lines.
2016-06-30 14:03:51 +02:00
Milan Hanajik
799fda63e9
Bug fix : Updating water meters results in case of test with 'parts'.
2016-06-30 12:55:35 +02:00
Milan Hanajik
9d56836c80
Procedure number displayed in ProceduresDlg (the list of procedures).
...
Deleting a procedure modified, confirmed by a question, change applied to the DB immediately,
Localization to DE, CS, ... pressure test and leak test, etc.
2016-06-28 15:09:32 +02:00
Milan Hanajik
8a3a0ca6ef
(1) iPerlCommunicationForm displays green/red rectangle as opto-data indication, (2) ProcedureDlg displays date and time of changes, ver. 2.8.314
2016-06-27 15:45:35 +02:00
Milan Hanajik
1337fff2dc
Fixed: (1) STOP button does not function in FlyingStart and FlyingStartMassCollection methods, (2) Results.Entities.WaterMeterData.Equals(.)
2016-06-15 17:04:25 +02:00
Milan Hanajik
2935bc2c77
Many localisation improvements, ver.2.7.297
2016-05-29 23:17:48 +02:00
Milan Hanajik
7c7f330a0b
Progress bar fixed for Pressure and Leak test.
2016-05-19 12:43:45 +02:00
Milan Hanajik
291bb72cf5
iPerlCommunicationForm resized depending on the number of iPerl-s, gray color, ver.2.5.273
2016-04-23 14:32:15 +02:00
Milan Hanajik
a41d0517d2
Bug fixes in resources, ano/ne usage, etc., ver.2.5.271
2016-04-20 17:45:18 +02:00
Milan Hanajik
e09aad2a6d
iPerlSpecial bug fix
2016-04-20 15:03:18 +02:00
Milan Hanajik
1d924d7d40
iPerlSpecial modifications: RFID ports defined by watermeters, no Quido used, ver.2.5.268.
2016-04-19 10:10:51 +02:00
Milan Hanajik
b1e0e74d8a
iPerlSpecial modifications
2016-04-18 13:38:13 +02:00
Milan Hanajik
9a725de4a9
Stable mass measurement rewritten, it can use immediate measurement, DB change, ver.2.5.265.
2016-04-14 17:03:33 +02:00
Milan Hanajik
e037720115
iPerlST: Logging of a STOP command via UI.
2016-04-14 09:16:20 +02:00
Milan Hanajik
f901367817
iPerl ST component, symbol IPERLST_SPECIAL, etc. added to the project, ver. 2.4.260.
2016-04-07 15:37:49 +02:00
Milan Hanajik
b006e36d52
Stop Backflow Valve added, used in FlyingStartMassCollection method, ver.2.4.248.
2016-03-18 10:36:33 +08:00
Milan Hanajik
2392bfa2a7
FlyingStartCollectionMethod timing modified, start valve used, ver.2.3.245.
2016-03-17 13:02:25 +08:00
Milan Hanajik
b86ca9fac8
Active FM pump is switched off in 'default action' after test (not when transition sequences are used), ver.2.3.242.
2016-03-15 19:29:47 +08:00
Milan Hanajik
25eff13c41
Bug fix in iPerl communication when L1 only or L2 only used.
2016-03-01 18:57:36 +01:00
Milan Hanajik
d2493b0331
Bug fix: padlo v Active mode na konci cyklu, ver.2.3.230.
2016-03-01 16:22:49 +01:00