Milan Hanajik c3fd5b9366 CEVAK_200 & FlyingStart[Tank|Mass]Collection : Water stopped immediately after test, before measuring the volume/mass. 2018-11-27 07:49:17 +01:00
Milan Hanajik aa24558d07 DataEntry.Standard6.CycleBeginningForm: Remark added, Results.ItemID: WM_remark, etc. added, ver. 2.18.1076 2018-11-26 14:00:44 +01:00
Milan Hanajik 40d4c74493 Bug fix in SequenceBase : FEWA-50 was crashing in Adjustment when T div was not defined), ver. 2.18.1075 2018-11-26 09:54:46 +01:00
Milan Hanajik bc89faf220 ver. 2.18.1074 2018-11-21 07:51:58 +01:00
Milan Hanajik 0b12e79820 FlyingStartMassCollComparative : Reference mass measurement error should be within 3%, ver. 2.18.1073 2018-11-21 07:16:08 +01:00
Milan Hanajik 7bdb7f99d4 FlyingStarMassCollComparative : Mass updated when comparative measurement done, ver. 2.18.1072 2018-11-20 17:49:58 +01:00
Milan Hanajik afea809b97 TestMethods.FlyingStartMassCollComparative.Sigle/Compound/HeatMeters added, ver. 2.18.1071 2018-11-20 17:11:22 +01:00
Milan Hanajik 3122f6dd9a Components upgraded: CEVAK-200 19.11.18 - logging of commands, FEWA-50 19.11.18 - control of valves for mass calibration, ver. 2.18.1070 2018-11-20 14:07:29 +01:00
Milan Hanajik a2f0781fb4 ver. 2.18.1068 2018-11-19 08:23:27 +01:00
Milan Hanajik 31a684f03a (1) DataEntry.iPerl.CycleBeginningForm displays iPerl dir. (2) iPerlCommFrm: CalLNA logged ok (3) FlyStMassCollProlonged and SmryResults modif, ver. 2.18.1067 2018-11-16 14:30:58 +01:00
Milan Hanajik 89eddaa3c2 Transition sequence before test is executed also between two test repetitions, ver. 2.198.1066 2018-11-14 16:41:58 +01:00
Milan Hanajik b060068a95 (1) Nivotrack.ReadStableLevelOp implemented, (2) MettlerToledo.Standard.ReadStableMassOp bug fix, (3) UpdateWeights() clean-up, ver. 2.18.1065 2018-11-14 15:49:43 +01:00
Milan Hanajik 3ffdf4e2cc WaitTankContainsMoreThenOp, related Various.TankWithLevelMsrmnt and TankDraining changes, ver. 2.18.1064 2018-11-14 13:07:37 +01:00
Milan Hanajik 7d1d95305f Transition between two repetitions added. 2018-11-14 08:23:01 +01:00
Milan Hanajik 98fc15a709 bool TestParams.ManualLevelMsrmnt added to ...TankCollection methods, is used in sequnces, ver. 2.18.1062 2018-11-13 18:02:57 +01:00
Milan Hanajik a8e0a8087d Stable level and volume measurement ... in progress. 2018-11-13 16:31:20 +01:00
Milan Hanajik f81c30f072 Elde component updated, water tower tank volume display, 13.11.2018 2018-11-13 15:29:19 +01:00
Milan Hanajik 05f6c8c75c UpdateTankWeightOp removed, ver. 2.18.1061 2018-11-13 15:29:18 +01:00
Milan Hanajik 76a08324b4 CtrlBrd.UpdateWeights() updates also tanks, is used in CtrlBrd.RunDeviceAfter(), UpdteTankWeightOp becomes obsolete, ver. 2.18.1060 2018-11-13 15:29:05 +01:00
Milan Hanajik 2a98c485ef ILevelMeter.Level (immediate measurement), Nivotrack uses correction table, etc. 2018-11-13 10:00:09 +01:00
Milan Hanajik 872409870e MetrologyDlgLevelMeterTab added. 2018-11-13 09:42:23 +01:00
Milan Hanajik f48a71ce12 UiBridge.Bridge.CloseModelessFormHandler isn't used, tank draining before a test is optional, fixes in simulations, ver. 2.18.1056 2018-11-12 16:57:28 +01:00
Milan Hanajik d2d571945c ver. 2.18.1055 2018-11-09 17:03:45 +01:00
Milan Hanajik bd9c3aa5e2 Q2 correction for Suez (RL, LR) modified, 'Q2 correction check Q2bc Q2ac' test method implemented. 2018-11-09 16:25:54 +01:00
Milan Hanajik 73ea0ff586 Previous results display software version, ver. 2.18.1054 2018-11-09 11:25:18 +01:00
Milan Hanajik 78408ed5eb Density calculated from (T up + T dn) / 2 and (Pr up + Pr dn) / 2 used everywhere, ver. 2.18.1053 2018-11-08 13:45:01 +01:00
Milan Hanajik f04cdccd20 EtPulsesK (FlyingStartMassCollectionProlonged) fixed for IPERL_TURA and IPERL_SPECIAL, ver. 2.18.1052 2018-11-08 10:41:05 +01:00
Milan Hanajik 82acf60f2e Target flow range for flow control shrinked by 15% from each side, ver. 2.18.2051 2018-11-08 09:54:40 +01:00
Milan Hanajik 68413867ad FlyingStartMassCollectionProlonged fixed for iPerlSpecial, ver. 2.18.1050 2018-11-07 16:28:36 +01:00
Milan Hanajik 1fd8881d53 LastError added to MeterTestRslt, result items, etc. when ORACLE_DB defined, etc. (CalibFactorLNA, OrigCalibFactorLNA) 2018-11-07 08:43:36 +01:00
Milan Hanajik cebdd71065 MID pulses for each meter calculated correctly in all FlyingStart... methods for datastream meters. 2018-11-07 08:13:48 +01:00
Milan Hanajik 668304cb72 Bug fix in Statistics : Min, Max calculation and UpdateGraph( ), ver. 2.18.1049 2018-11-06 13:39:49 +01:00
Milan Hanajik c28c5a5554 Bug fix in Various.TankWithLevelMsrmnt.Tank. 2018-11-02 10:17:52 +01:00
Milan Hanajik 450493069c (1) SequenceBase.DrainTheTank( ) : DrainValve2 is open first, DrainValve in the 2nd half, (2) Two phase draining in MainSeq when bench is started, ver. 2.18.1047 2018-10-26 11:21:07 +02:00
Milan Hanajik d7519aa95a Draining with 2 drain valves in SequenceBase. 2018-10-25 19:44:54 +02:00
Milan Hanajik e89ab89874 TankCfgCtrl displays ILevelMeter-s, DrainValve2 is in IScaleOrTank and TankWithLevelMsrmnt UI, ver. 2.18.1046 2018-10-25 18:09:08 +02:00
Milan Hanajik 025fa81941 SequencBase : ReadRegistersTempPressAmbient( ) fixed - works OK without an IScale - start/stop method works with a tank, ver.2.18.1045 2018-10-25 17:02:12 +02:00
Milan Hanajik 845c66b511 HART communication : IHart,Hart, Nivotrack changes, sending/receiving works OK. Todo: Interface the level, ver. 2.18.1044 2018-10-25 15:34:48 +02:00
Milan Hanajik 3725e238fc Various.TankWithLevelMsrmnt can use a calibration table loaded from a CSV file. 2018-10-25 15:34:46 +02:00
Milan Hanajik ac2ac82187 Diverter fixed for CEVAK_200, ver. 2.18.1042 2018-10-24 17:16:56 +02:00
Milan Hanajik 5e6be0c4b4 (1) Bug fix in calculations in flying start methods when WMPulses == 1, (2) VolumeCTV results item added, ver. 2.18.1041 2018-10-24 15:04:51 +02:00
Milan Hanajik ed66c6a259 (1) Tank & ManualLevelMsrmnt components added, (2) Sequences cope with IScaleOrTank, (3) FixedStartTankCollection & FlyingStartTankCollection added, etc., ver. 2.18.1040 2018-10-24 13:18:38 +02:00
Milan Hanajik 0db7736247 Minor fix in TestMethods.FlyingStart.FlyingStartSeq. 2018-10-23 19:45:53 +02:00
Milan Hanajik 02cebe0966 CEVAK 200 Elde component upgraded: 23.10.2018, I4 and I5 fixed. 2018-10-23 13:13:26 +02:00
Milan Hanajik 4f2bb6291f Strings, ver. 2.18.1036 2018-10-21 10:58:38 +02:00
Milan Hanajik 498c8afbe4 ver. 2.18.1035 2018-10-18 12:57:09 +02:00
Milan Hanajik 0e6dce4750 Error limits before Q2 correction are not shifted to target, factor 1.0 used for Q2CorrType.RL and Q2CorrType.LR, ver. 2.18.1034 2018-10-18 09:28:35 +02:00
Milan Hanajik 7a74579c8b Q2 correction RL and LR addresses swapped, Q2 correction value multiplied by 0.5, ver. 2.18.1033 2018-10-17 14:41:07 +02:00
Milan Hanajik c23630a980 Separate addresses Q2CorrFactorsAddrRL (0x1878) and Q2CorrFactorsAddrLR (0x1879), ver. 2.18.1031 2018-10-17 11:31:28 +02:00
Milan Hanajik 205df83c1c Test sequences modified, Q2CorrRFlow and Q2CorrLFlow set in iPerlCommunicationForm only, ver. 2.18.1030 2018-10-17 09:56:01 +02:00