Cause:
1. Background: there was a suspicion that the Bukoven board left RefPulses active across operations; this was investigated and ruled out. The pulse counter is reset by testInProgress when an operation is reused. During the third DataEntry window testInProgress had been temporarily disabled (SLM vs Karlsruhe difference), which allowed RefPulses to appear to persist.
2. Increase revision to 3.9.3134.113
Solution:
1. Restore/ensure testInProgress behavior during the DataEntry sequence and explicitly reset the pulse counter when starting a new operation.
2. Increased revision to 3.9.3134.113
- Store the value as the default PumpPower for subsequent test instances in the cycle.
- Add logging when PumpPower is initialized from the pump.
- Add logging at test start including test name, repetition number,
last repetition flag, and PumpPower to improve diagnostics.
Add support for `ICommonRegReader` interface, enhance `ISmartReader` functionality, and update water meter state handling logic across multiple classes.
- Extended CJMS11 camera handling with new functionalities, including image grabbing, resolution configuration, and improved ROI support.
- Added new `ToString` method implementations for enhanced debugging and logging in key classes like `JmsMessage`, `JmsPacket`, and `RoiCfg`.
- Introduced additional commands (`start_stream_images`, `stop_stream_images`) in `CommandM` and its enum.
- Implemented new resolution handling in `RoiCfg` with support for configurable image frames.
- Refactored resolution-related UI elements in `RoiCfgCtrl` to add a dropdown for selecting resolution.
- Made minor UX improvements by replacing inconsistent string formats with verbatim strings in console messages.
- Updated project dependencies with new resolution-related utilities (`Frame` and `ResolutionFrames`).
- Resolved camera-specific symbolic issues by transitioning to `CJMS11.Camera` over prior naming inconsistencies.