Commit Graph
114 Commits
Author SHA1 Message Date
Milan Hanajik f00196c4a8 (1) Adjustment.WMErrorsForm48, (2) MeretRS485Address = new byte[6] for IZRAEL_50 2020-03-31 11:28:42 +02:00
Milan Hanajik dffaa1d3a8 Earlier mass measurement and tank draining in FlyingStartMassCollProlonged, ver. 2.25.1437 2020-03-10 15:39:39 +01:00
Milan Hanajik 7f56fa0aa3 Gelsenwasser : Flowmeter number with diverter info. 2020-03-06 08:21:24 +01:00
Milan Hanajik bd15d3bd83 GEWLSENWASSER: symbol, component, RV.adcChannel and Div.flowMtrNr4Cmd, ROMA_200: route bit 80 fixed.
RegulValve.adcChannel and Diverter.flowMtrNr4Cmd for GELSENWASSER
2020-03-02 12:01:23 +01:00
Milan Hanajik dc31e833ee BatchResults.WaterMeters eliminated, Batch.WaterMeters are used instead ... many changes 2020-02-05 10:33:32 +01:00
Milan Hanajik 6ec2852581 DEWA PT300 : Bit 80 / VI11 issue fixed, ver. 2.25.1405 2020-01-27 14:21:00 +01:00
Milan Hanajik 2ad50a9708 Command.Stop enqueued after Emergency stop in similar way as before. 2020-01-21 17:40:31 +01:00
Milan Hanajik b4763441a8 (1) Bug fix in sending FM pump frequencies to control board, (2) More logging, ver. 2.24.1386 2019-12-18 10:45:25 +01:00
Milan Hanajik 88a7de450a Users cleanup, ver. 2.24.1382 2019-12-13 18:08:38 +01:00
Milan Hanajik e9c6f58e0d ALZIR_25 symbol and component added 2019-11-26 18:03:24 +01:00
Milan Hanajik 3e026d7129 Elde.RegisterReader.RegisterReader.Position, IRegisterReader.Position, etc. introduced., ver. 2.24.1365 2019-11-20 13:09:38 +01:00
Milan Hanajik 0297d74b17 ROMA_200 : (1) Component upgraded (12.11.2019), (2) Dummy scale does not overwrite Tank/DrainValve info, (3) minor changes, ver. 2.24.1363 2019-11-13 08:14:01 +01:00
Milan Hanajik 708610b8ab ROMA_200 : Component added, symbol processing added, ver. 2.24.1359 2019-11-07 14:45:09 +01:00
Milan Hanajik 424be60a05 Bug fixes : (1) FlowMeterDewa, (2) ControlComWrap.ReferenceFreqs(int i) 2019-10-30 09:24:48 +01:00
Milan Hanajik d5c0eb9c09 (1) TBF.BenchControl.Elde.SendCommandArgs class and cbCommandQueue (2) DiverterToTank, DiverterToSink commands modified. 2019-10-24 12:57:37 +02:00
Milan Hanajik dbe87a375d TransitionContext.AfterTestWithOverlap, PID coef. set earlier as well, nextHydroTest in MainSeq. 2019-10-24 12:56:59 +02:00
Milan Hanajik 2aa8b19c87 FlowMeter, FlowmeterTriplet : Condiiton (flow < 0.1 * NominalFlow) removed from LtrPerPulseCorrected( ) 2019-09-26 15:39:19 +02:00
Milan Hanajik 9caae8dffd (1) FlowMeteDewa uses EtPulses2, EtPulses3, (2) WMChart fixed, Q4 displayed, (3) Minor MainSeq bug fix. 2019-09-22 16:37:58 +02:00
Milan Hanajik 3333b4baa2 FlowMeterDewa bug fix, wrong indices used when calculating a correction of a sum of flows. 2019-09-19 07:45:21 +02:00
Milan Hanajik 994568799d Refactorization: TBF.UI namespace, no change of function, ver. 2.18.1314 2019-09-17 10:58:44 +02:00
Milan Hanajik d4eb52d70e RegulValve.SetFlowOp in progress 2019-09-12 13:50:53 +02:00
Milan Hanajik 6079c8419f (1) Diverter switch time measurement modifications (2) const int CountWhenSendingRdDivCmd = 1, CountWhenReadingDiv = 3. 2019-09-04 15:08:36 +02:00
Milan Hanajik 375cea26a6 TURA_IPERL_NEW : (1) Processing symbol implemented, (2) Elde component dated 17.7.2019 added, ver. 2.18.1273 2019-07-24 15:48:32 +02:00
Milan Hanajik 1d31e5c4b7 Output.DB.SaveDiverterCorrections added. 2019-07-23 11:21:43 +02:00
Milan Hanajik a6b8fade23 (1) DiverterTest component added, (2) Filipiny_50 component 9.7.2019, (3) flowMeterIdxAndDiv for FILIPINY_50, ver. 2.18.1263 2019-07-09 15:58:13 +02:00
Milan Hanajik 58d1c1e1ef FILIPINY_50 symbol processing added to sources, component dated 28.6.2019 added, ver. 2.18.1257 2019-06-28 13:04:25 +02:00
Milan Hanajik 1c5c260a82 Puchong : (1) RegValveCalib[] array dimensions changed, (2) component upgraded (26.6.2019), ver. 2.18.1254 2019-06-26 16:25:40 +02:00
Milan Hanajik 4642abac2d SequenceBase : SummaryResults : tstRslt.ConstMasterRaw and tstRslt.RefFlowmeter() unstead of outPath.FlowMeter... (bug fix), ver. 2.18.1252 2019-06-25 12:08:14 +02:00
Milan Hanajik 721904dbae Diverter : flowMtrNr4Cmd fixed for PUCHONG_200, ver. 2.18.1251 2019-06-24 11:22:47 +02:00
Milan Hanajik 899caac18b (1) Puchong-200 component upgraded, 24.6.2019 : dimensions of arrays changed, etc., (2) Related ControlComWrap changes, ver. 2.18.1250 2019-06-24 10:38:20 +02:00
Milan Hanajik f8458a4275 TURA_IPERL : Diverter.flowMtrNr4Cmd corrected. 2019-06-06 09:03:23 +02:00
Milan Hanajik 3fceee156b (1) MetrologyDlgDiverterTab added to UI, (2) double TestTimeCorrection(double flow) added to IDiverter and implemented in Elde.Diverter and Dummy.Diverter. 2019-05-15 11:18:20 +02:00
Milan Hanajik d51edbfbfe Elde.FlowMeterDewa : (1) Exact LtrPerPulseCorrected calc. (2) nominal flow and flowmeters bitfield (=Idx0) calculated from particular flowmeters. 2019-05-12 08:17:52 +02:00
Milan Hanajik 7724c004a0 Elde interface : filters, pidCoef and shortPulses are set by SetFilterPidShortPulses( ) only. 2019-05-10 16:28:18 +02:00
Milan Hanajik 4221de3b22 Stopping flow regulation modifications : cmd=Stop, real flowMeterNr used. 2019-05-10 10:53:48 +02:00
Milan Hanajik 7fa06079c2 Short pulses bug fix : argument was not sent when reading diverter transitions, ver. 2.18.1218 2019-05-09 16:22:20 +02:00
Milan Hanajik 667f548101 ControlComWrap logging levels modified. 2019-05-09 10:42:51 +02:00
Milan Hanajik fed11e6439 Short pulses bug fix. 2019-05-07 13:24:33 +02:00
Milan Hanajik d0bba74dff (1) filters[] initialized earlier in test method sequences, (2) filters and shortPulses used in SetFlowOp(.), ver. 2.18.1206 2019-05-02 10:23:33 +02:00
Milan Hanajik e9bda4f1b2 Short pulses test parameter used in SendCommand(..., shortPulses), ver. 2.18.1204 2019-04-29 10:36:08 +02:00
Milan Hanajik 5dad80d031 Stopping flow regulation after a test completes (in three test methods). 2019-04-25 11:00:34 +02:00
Milan Hanajik 24e23d01e8 More changes : RequredFlowLo/Hi, ReferenceFlow, RefereneFreq, etc. float -> double, ver. 2.18.1202 2019-04-25 08:58:54 +02:00
Milan Hanajik f8671ac516 (1) Range of flow extended to 125%, (2) RequredFlowLo/Hi etc. float -> double, ver. 2.18.1192 2019-04-15 08:15:47 +02:00
Milan Hanajik 556290abf6 DEWA300 double and tripple flowmeters, NominalFlow and LtrPerPulse are doubles, ver. 2.18.1191 2019-04-11 15:39:46 +02:00
Milan Hanajik b410f473e2 TempMeter zero-based index range extended to 0..15, ver. 2.18.1164 2019-03-13 09:39:10 +01:00
Milan Hanajik d45c3f96d6 TBF : (1) flow setting timeout = 300 s = 5 min., (2) stable mass msrmnt. timeout = 300 s = 5 min., ver. 2.18.1162 2019-03-11 08:36:02 +01:00
Milan Hanajik 75e5b75d4d DEWA_300 : (1) component upgraded (6.3.2019), (2) Diverter: flowMtrNr4Cmd fixed, ver. 2.18.1159 2019-03-06 09:42:25 +01:00
Milan Hanajik b47f5e32d4 DEWA_300 symbol usage fixed, ver. 2.18.1158 2019-03-05 15:12:24 +01:00
Milan Hanajik b10ab44fa9 (1) MetrologyDlg displays corrections for all pressure meters, (2) Elde.PressureMeter and Modbus.PressureMeter.Meret use corrections. 2019-03-04 09:20:16 +01:00
Milan Hanajik 138e436645 (1) DEWA_300 component added, (2) DEWA_300 symbol added, (3) IZRAEL_200 symbol bug fix, ver. 2.18.1151 2019-02-25 12:49:04 +01:00