Milan Hanajik
|
d2b745dd8e
|
Temperature Tup and Tdown can be checked in Adjustment, Endurance, FlyingStart, FlyingStartMassCollection and FixedStart methods, ver. 2.14.573
|
2017-06-08 16:55:24 +02:00 |
|
Milan Hanajik
|
db55f5b3fd
|
DB entities, mappings and UI added for 'Control water temp.', 'Temp. lim. lo' and 'Temp. lim. hi'.
|
2017-06-08 16:06:48 +02:00 |
|
Milan Hanajik
|
21016a1500
|
iPerl and iPerlHead separated, iPerl removed (WaterMeter should be used instead).
|
2017-06-08 09:14:30 +02:00 |
|
Milan Hanajik
|
294cc73e36
|
tstRslt.FlowMin evaluated, saved to Oracle DB only.
|
2017-05-25 14:06:05 +02:00 |
|
Milan Hanajik
|
71613cba5d
|
Q_ref_mean and many other result items added.
|
2017-05-19 11:25:24 +02:00 |
|
Milan Hanajik
|
6cace280c9
|
SequenceBase.LogProcessDataHeader() added.
|
2017-05-10 13:54:38 +02:00 |
|
Milan Hanajik
|
847a4d74d6
|
UpdateTempPressDensAmb(tstRslt) function added to SequenceBase, used by all sequences.
|
2017-05-10 10:43:33 +02:00 |
|
Milan Hanajik
|
ed83ae57c5
|
Progress bars are not displayed as 'completed' when a test was aborted.
|
2017-05-05 12:46:37 +02:00 |
|
Milan Hanajik
|
17c685148e
|
(1) Flow selection in New Test Wizard extended, (2) MainSeq and BencControlPael modified, etc.
|
2017-05-03 22:24:25 +02:00 |
|
Milan Hanajik
|
fa57c51786
|
ProcedureParams initialization/constructors modified. ProcedureParamsBase modified.
|
2017-05-01 16:03:45 +02:00 |
|
Milan Hanajik
|
59392d8bdc
|
MakeSimulated fixed when there are multiple test repetitions, ver. 2.12.555
|
2017-05-01 10:28:43 +02:00 |
|
Milan Hanajik
|
eafcf016f3
|
Setting regulation valves before flow setting disabled, caused porbles all the time, ver. 2.12 549
|
2017-04-24 11:58:57 +02:00 |
|
Milan Hanajik
|
05982cc2ff
|
Endurance test method sequence modified.
|
2017-04-24 09:44:11 +02:00 |
|
Milan Hanajik
|
d372a38e7d
|
Camera time read with each sample, calculation : VolumeStart, VolumeEnd, TimestampStart, TimestampEnd used, ver. 2.12.530
|
2017-04-07 11:29:35 +02:00 |
|
Milan Hanajik
|
44735260ce
|
CLP1611 Measurement done only on successfully detected ROI-s, ver. 2.12.530
|
2017-04-06 23:47:24 +02:00 |
|
Milan Hanajik
|
464dfc6dd1
|
FlyingStartMassCollection : 'Next' button can be used to stop the test.
|
2017-04-05 22:01:21 +02:00 |
|
Milan Hanajik
|
049bbc8655
|
DEWA Q2 correction modified, Results.Entities.WaterMeter columns added (iPerl only).
|
2017-03-31 14:17:18 +02:00 |
|
Milan Hanajik
|
5f2da63339
|
Drain valve removed from Output path, outPath.Scale.DrainValve used instead of outPath.DrainValve, wait for Event. BalanceDone before 2nd mass measurement in FlyingStartMassCollection, ver. 2.12.519
|
2017-03-29 09:22:39 +02:00 |
|
Milan Hanajik
|
d420128b4b
|
Draining modified, in BERLIN done always before flow setting, ver. 2.12.518
|
2017-03-28 23:54:52 +02:00 |
|
Milan Hanajik
|
3c4fe34c1d
|
Test_volume_exceeds_the_scale_capacity situation handled correctly, no Error state.
|
2017-03-27 14:08:53 +02:00 |
|
Milan Hanajik
|
8d4af6f347
|
Bug in iPerl IRegisterReader usage by FlyingStartMassCollectionSeq fixed, ver. 2.12.501
|
2017-03-20 17:44:28 +01:00 |
|
Milan Hanajik
|
87bc0131cf
|
Tests when test volume exceeds the tank capacity cannot be executed, an error message appears.
|
2017-03-10 13:10:57 +01:00 |
|
Milan Hanajik
|
4515f0fc13
|
FlyingStartMassCollectionSeq modified : Valves/pumps are closed immediately after the test only when there are no subsequent test repeats.
|
2017-02-21 10:45:26 +01:00 |
|
Milan Hanajik
|
970fc886c6
|
FlyingStartMassCollectionSeq : If transitionAfter is not used, the valves/pumps are closed immediately after the test before the 2nd mass measurement, ver. 2.12.472
|
2017-02-17 10:51:30 +01:00 |
|
Milan Hanajik
|
8d4910fcb0
|
Symbols: introduced IPERL, ORACLE_DB, HEAT_METERS, TURA_IPERL, TURA_SPECIAL
abandoned IPERLST, IPERLSTSPECIAL, HEAT_METERS_SUPPORT
|
2017-02-14 13:42:22 +01:00 |
|
Milan Hanajik
|
38c199f6f9
|
Interfaces between Camera and Roi and sequences finalized, TODO: network communication, ver. 2.12.446
Sequences more robust for debugging, T and Pr-meters checked for null
|
2017-01-25 17:28:57 +01:00 |
|
Milan Hanajik
|
044e53f2b2
|
Changes under construction : ROI registration to Cameras, ver. 2.12.441
|
2017-01-24 12:34:52 +01:00 |
|
Milan Hanajik
|
2150ced11f
|
Propagation of ROI parameters between ROI-s and Cameras implemented, ver. 2.12.438
|
2017-01-22 20:40:12 +01:00 |
|
Milan Hanajik
|
6d45b2c878
|
RoiDetectionSeq modified, ready to be tested.
|
2017-01-16 15:51:34 +01:00 |
|
Milan Hanajik
|
c73cf7002f
|
Camera.Roi.MeasurementOp added, UDP listener added, PulsesPerLtr (and ProcedureParams) added, etc.
|
2017-01-16 13:49:29 +01:00 |
|
Milan Hanajik
|
89901c75f7
|
Revert "Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow."
This reverts commit be52e2df96.
|
2016-12-16 13:07:54 +01:00 |
|
Milan Hanajik
|
be52e2df96
|
Elde.FlowMeterTwins bug-fix in calculation of ref. pulses and flow.
|
2016-12-12 16:43:04 +01:00 |
|
Milan Hanajik
|
216e08d57c
|
Execute(...) arguments changed everywhere, repetitionNr usage depends on outerLoopMode, outerLoopCounter, ver. 2.12.412
|
2016-12-10 13:03:35 +01:00 |
|
Milan Hanajik
|
f3b178473c
|
Outer loop logic added, TODO: (1) Begin-block and End-block test methods, (2) support in test method sequences
|
2016-12-10 11:33:31 +01:00 |
|
Milan Hanajik
|
6df36659ab
|
Dummy.Balance component added
|
2016-12-09 12:13:59 +01:00 |
|
Milan Hanajik
|
98a773700e
|
Bug fix related to PressMtrDelta, ver. 2.12.386
|
2016-11-17 08:48:52 +01:00 |
|
Milan Hanajik
|
bab677c5c2
|
PressMtrDelta added to BenchPath, PressDeltaXyz added to TestRslt, test methods modified, ver. 2.12.373
|
2016-10-18 19:14:01 +02:00 |
|
Milan Hanajik
|
d1fb0e0f0a
|
T warm/cold lo/hi renamed to T hi/lo min/max
|
2016-10-18 17:27:24 +02:00 |
|
Milan Hanajik
|
03c027ab33
|
LogProcessDataHeatMeters, ver. 2.11.371
|
2016-10-18 11:49:32 +02:00 |
|
Milan Hanajik
|
0fb3a74879
|
Feeding regulation valves functionality implemented, ver. 2.11.367
|
2016-10-13 16:08:29 +02:00 |
|
Milan Hanajik
|
45e0f50562
|
Elde.RegulValve supports 'ReTryCommands' parameter (default = false), ver. 2.11.365
|
2016-10-13 16:08:15 +02:00 |
|
Milan Hanajik
|
dddfc4bed5
|
Bug-fixes in FlyingStart and FlyingStartMassCollection heat meters, T ref warm and T ref cold statistics, ver. 2.10.362
|
2016-10-12 01:23:38 +02:00 |
|
Milan Hanajik
|
b3a2c3a0fc
|
FlyingStart, FlyingStartMassCollection and CombinedWithDetection methods support Simulation mode, ver. 2.10.360
|
2016-10-11 12:53:17 +02:00 |
|
Milan Hanajik
|
c84fd8089a
|
FlyingStart and FlyingStartMassCollection methods: 'Begin cycle' dialog closed before 'Heat meters prompt message' is displayed.
|
2016-10-11 09:10:33 +02:00 |
|
Milan Hanajik
|
5f21b5ab26
|
ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods.
|
2016-10-10 14:35:59 +02:00 |
|
Milan Hanajik
|
f8331c1c1c
|
Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359
|
2016-10-10 14:23:20 +02:00 |
|
Milan Hanajik
|
3c15dbab9e
|
Bug fixes in heat meter testing using pulses, Flying start and Flying start mass collection methods, ver. 2.10.358
|
2016-10-10 11:35:45 +02:00 |
|
Milan Hanajik
|
438028506e
|
Flows are internally stored and processed in double variables (except of Qfrom, Qto, flowmeter nominal flow)
|
2016-10-07 16:22:36 +02:00 |
|
Milan Hanajik
|
010afcd1e4
|
Temperatures are internally stored and processed in double variables (except of ambient temp.).
|
2016-10-07 15:41:27 +02:00 |
|
Milan Hanajik
|
7df9333fba
|
Statistics return doubles instead of float, casting is done just when writing to entities.
|
2016-10-07 14:46:14 +02:00 |
|