Commit Graph

122 Commits

Author SHA1 Message Date
Milan Hanajik
095d4aab2b Cosmetical changes and minor improvements 2018-01-24 13:55:16 +01:00
Milan Hanajik
d640a2f4b6 FlyingStartFirstRepetWithMassColl test method, 'ConstMaster' and 'ErrorMaster' from the 1st rep. used in remaining reps., ver. 2.17.775 2018-01-16 17:22:21 +01:00
Milan Hanajik
459cb5bb4a (1) Progress bars fixes, (2) Fixes in sequences: cBrd.StopPreviousOp() called at the end (also) when isLastRepetition == true. 2017-12-08 15:07:09 +03:00
Milan Hanajik
c5453fff5b MainSeq, ITestMethod and all test methods changed, transitions are done in MainSeq (DoTransitions()), no outerLoopCounter, ver. 2.17.757 2017-12-03 18:44:57 +03:00
Milan Hanajik
cebaab8e8b iPerl : ConfigStruct erased at the beginning of 'ReadConfiguration', iPerlHead.ClearData() called in MainSeq when procedure selected, ver. 2.17.753 2017-12-01 12:06:24 +01:00
Milan Hanajik
97fc922321 Changes : (1) StandardCamera.TestStartEndForm size, (2) FixedStartMassCollectionSeq delay before 1st mass m., (3) German, (4) Reload prev. btn. hidden, ver. 2.17.744 2017-11-22 10:54:51 +01:00
Milan Hanajik
a2620870ad Changes for Audit, ver. 2.17.730 2017-11-13 16:17:36 +01:00
Milan Hanajik
0c2839e6c9 Temperature (TempUpMean + TempDownMean) / 2 used for density and volume calculations, ver. 2.17.712 2017-10-19 19:04:13 +02:00
Milan Hanajik
38d7562bb3 Repettition nr. > 1 can be selected in the main sequence. 2017-10-19 09:19:31 +02:00
Milan Hanajik
8b321e36db Diverter times saved in SummaryResults and AllResults, timing of 'end' measurement slightly changed, ver. 2.17.706 2017-10-18 12:08:15 +02:00
Milan Hanajik
3822c6f5ab Calculated error limits for heat meter flow measurement testing, ver. 2.17.705 2017-10-18 10:52:15 +02:00
Milan Hanajik
9a905c6111 Minor improvements. 2017-10-17 18:22:01 +02:00
Milan Hanajik
239bcddfa2 ReadDiverterTransitionOp implemented, ver. 2.17.704 2017-10-17 16:06:46 +02:00
Milan Hanajik
04db65f01f Kepno 50 component upgraded, related changes in IControlCom etc., dated 11.10.2017 and 16.10.2017. 2017-10-17 16:04:12 +02:00
Milan Hanajik
9ad0872854 Bug fix: Error flags related bug fixed, ver. 2.17.689 2017-10-04 13:08:28 +02:00
Milan Hanajik
9fa025caa4 Diverter and start/stop valve switch time logging in ms, ver. 2.17.679 2017-09-28 17:11:41 +02:00
Milan Hanajik
4efba80fc6 Measurement of valve open/close time required for E11, E12 evaluation. DiverterStart/DiverterEnd is float in sec., ver. 2.17.677 2017-09-28 12:54:16 +02:00
Milan Hanajik
ae1ed99c9f ErrorFlags E15 and E16, Results DB upgraded (int ErrorFlags in WaterMeter table, int DiverterStart, DiverterEnd in TestRslt table), ver. 2.17.674 2017-09-28 00:07:47 +02:00
Milan Hanajik
63a6cb7afe Diverter time logging in FlyingStartMassCollectionSeq, camera commands logging, ver. 2.16.670 2017-09-27 09:11:53 +02:00
Milan Hanajik
3fb487b67b (1) E9,E10,E15,E16 implemented, (2)Zapiska: Each WM is in one table row, (3) TableRowNr,TableColumnNr,WMRemark added to RsltItems 2017-09-25 22:25:09 +02:00
Milan Hanajik
62ceb13385 FlowStart and FlowEnd saved into TestRslt at the end of each test. 2017-09-13 15:48:31 +02:00
Milan Hanajik
df42ec3d3a Saving ResultCode with RFID and OptoData error code for iPerls implemented, ver. 2.16.646 2017-08-22 09:28:19 +02:00
Milan Hanajik
d5904fe9fa ErrorFlags implementation completed. TODO: E9, E10, E11, E12, E15, E16. Ver. 2.16.643 2017-08-21 12:36:37 +02:00
Milan Hanajik
20d8fbc389 ErrorFlags component added, Results.Entities.TestRslt upgraded to DB v.2.16, ErrorFlags and ErrorFlagsMd added, used in test methods, ver. 2.16.642 2017-08-20 09:54:42 +02:00
Milan Hanajik
175571072f Cleanup 2017-08-19 13:41:44 +02:00
Milan Hanajik
56e006318f Utils.ShowROute() -> Utils.RouteToStr(), dead code Evaluate and Publish removed from all test methods 2017-07-25 16:10:06 +03:00
Milan Hanajik
548973cf11 Bug fixes: (1) Error msg. deleted after selection, (2) pidCoef usage during test, (3) Drain valve always closed in FlyingStartMassCollection. 2017-07-25 11:41:06 +03:00
Milan Hanajik
8d249a96f4 Fixes in Buoyancy calculation, ver. 2.14.612 2017-07-20 19:54:33 +03:00
Milan Hanajik
9bf66f651a Buoyancy is 1.00103, not 1001.03 2017-07-19 07:53:52 +02:00
Milan Hanajik
77a6aff593 iPerl communication changes (completed as in branch 12 - Greece). 2017-07-18 08:43:16 +02:00
Milan Hanajik
bb962ad3b7 iPerl communication changes (in progress). 2017-07-14 17:13:07 +02:00
Milan Hanajik
00a2289e92 Evaluation of Results.Entities.TestRslt.TestDone, Results.Entities.Batch.Buoyancy() etc. fixed, ver. 2.14.599 2017-07-04 11:19:05 +02:00
Milan Hanajik
e71795bfe5 Masses, Buoyancy, Density corr. added to results, Buoyancy -> TestRslt, Dens.corr. -> Batch, MetrologyDlgDensityTab, etc. 2017-06-29 23:04:17 +02:00
Milan Hanajik
17f6f7c3be XmlSerializers created by XmlSerializer.FromType(new[] {typeof(...)})[0]; This prevents throwing an exception => better debugging. 2017-06-22 21:37:05 +02:00
Milan Hanajik
1bf118bdb9 Generic improvements 2017-06-15 18:58:51 +02:00
Milan Hanajik
d2b745dd8e Temperature Tup and Tdown can be checked in Adjustment, Endurance, FlyingStart, FlyingStartMassCollection and FixedStart methods, ver. 2.14.573 2017-06-08 16:55:24 +02:00
Milan Hanajik
db55f5b3fd DB entities, mappings and UI added for 'Control water temp.', 'Temp. lim. lo' and 'Temp. lim. hi'. 2017-06-08 16:06:48 +02:00
Milan Hanajik
21016a1500 iPerl and iPerlHead separated, iPerl removed (WaterMeter should be used instead). 2017-06-08 09:14:30 +02:00
Milan Hanajik
294cc73e36 tstRslt.FlowMin evaluated, saved to Oracle DB only. 2017-05-25 14:06:05 +02:00
Milan Hanajik
71613cba5d Q_ref_mean and many other result items added. 2017-05-19 11:25:24 +02:00
Milan Hanajik
6cace280c9 SequenceBase.LogProcessDataHeader() added. 2017-05-10 13:54:38 +02:00
Milan Hanajik
847a4d74d6 UpdateTempPressDensAmb(tstRslt) function added to SequenceBase, used by all sequences. 2017-05-10 10:43:33 +02:00
Milan Hanajik
ed83ae57c5 Progress bars are not displayed as 'completed' when a test was aborted. 2017-05-05 12:46:37 +02:00
Milan Hanajik
17c685148e (1) Flow selection in New Test Wizard extended, (2) MainSeq and BencControlPael modified, etc. 2017-05-03 22:24:25 +02:00
Milan Hanajik
fa57c51786 ProcedureParams initialization/constructors modified. ProcedureParamsBase modified. 2017-05-01 16:03:45 +02:00
Milan Hanajik
59392d8bdc MakeSimulated fixed when there are multiple test repetitions, ver. 2.12.555 2017-05-01 10:28:43 +02:00
Milan Hanajik
eafcf016f3 Setting regulation valves before flow setting disabled, caused porbles all the time, ver. 2.12 549 2017-04-24 11:58:57 +02:00
Milan Hanajik
05982cc2ff Endurance test method sequence modified. 2017-04-24 09:44:11 +02:00
Milan Hanajik
d372a38e7d Camera time read with each sample, calculation : VolumeStart, VolumeEnd, TimestampStart, TimestampEnd used, ver. 2.12.530 2017-04-07 11:29:35 +02:00
Milan Hanajik
44735260ce CLP1611 Measurement done only on successfully detected ROI-s, ver. 2.12.530 2017-04-06 23:47:24 +02:00