Cause:
1. Background: there was a suspicion that the Bukoven board left RefPulses active across operations; this was investigated and ruled out. The pulse counter is reset by testInProgress when an operation is reused. During the third DataEntry window testInProgress had been temporarily disabled (SLM vs Karlsruhe difference), which allowed RefPulses to appear to persist.
2. Increase revision to 3.9.3134.113
Solution:
1. Restore/ensure testInProgress behavior during the DataEntry sequence and explicitly reset the pulse counter when starting a new operation.
2. Increased revision to 3.9.3134.113
Refactor Flip Mode parameter type in `WMeterRsltItemSpec` to `Quantity.String` for consistency. Add `SetTestModeOpto7Str` alias to improve readability and replace legacy A0 test mode reference in `iPerlCommunicationParams`.
Introduce configurable timeouts for data entry volume reads in `IRegReaderSmart` and its implementations: added optional timeout parameters and updated default values across associated forms and methods. Updated `EntryFormCfg` to support customizable timeout settings.
Add robust handling for form closure in UNI Data Entry: prevent operations on disposed/closing forms, enhance logging, and update logic in serial number and volume updates. Increment version to 3.9.3141.0.
Add debug logging and UI enhancements for data entry processes: Improve register reader handling in sequences and forms, add detailed data entry debug logs, integrate serial number and volume watermarking, and update localized strings in multiple languages.
Add Flip Mode support across iPerl-related test methods and database schema: implement FlipMode property, update MeterTestRslt mappings, integrate schema migration logic, and refine test result handling.
Enhance iPerl dialog layout and error handling: improve `ShuffleTextBoxes` with positional mapping, refine checkbox state tracking, add detailed logging for labels and checkboxes, and handle serial port exceptions. Increment version to 3.9.3139.0.
Add support for Flip Mode configuration in iPerl: Implement `SetFlipMode` functionality in `OptoHeadTest` and `RadioService`, integrate constants, enhance UI, and add unit and integration tests for constant/randomized flip mode settings.
Add AllyReader and AllyCalibration support with tests: Introduce new register readers, calibration methods, and comprehensive unit tests for integration and functionality validation. Update project files accordingly.
Add support for reading and handling additional common parameters in OptoHeadTest. Extend RadioService and related classes with enhanced parsing and validation logic. Update UI and constants for functionality integration.
Add support for reading additional common parameters in OptoHeadTest. Enhance `RadioService` and `VersionTypeResult` with new parsing logic. Update related constants and UI elements for functionality integration.
Cause:
1. Background: there was a suspicion that the Bukoven board left RefPulses active across operations; this was investigated and ruled out. The pulse counter is reset by testInProgress when an operation is reused. During the third DataEntry window testInProgress had been temporarily disabled (SLM vs Karlsruhe difference), which allowed RefPulses to appear to persist.
2. Increase revision to 3.9.3134.112
Solution:
1. Restore/ensure testInProgress behavior during the DataEntry sequence and explicitly reset the pulse counter when starting a new operation.
2. Increased revision to 3.9.3134.112
Improve `VersionTypeResult` parsing and handling: Add compact/legacy payload support. Extend `ReadingUnits`. Update `IperlHatIntegrationTests` and `RadioService` with new tests and functionality integration.
Add protocolCommons classes and enhance RadioService with support for CalibrationFactor, VersionType, ReadingUnits, and FlipMode operations. Add corresponding unit tests for validation. Update project files.
Cause:
1. Missing functionality to display remaining time during tests in `StandingStartMassCollectionSeq.cs` and `StandingStartMassCollectionAdvanceSeq.cs`.
2. Assembly version and file version required an update to reflect changes.
Solution:
1. Implemented remaining time display in `StandingStartMassCollectionSeq.cs` and `StandingStartMassCollectionAdvanceSeq.cs` using `Bridge.OnActivity` to show time in minutes and seconds or seconds only.
2. Updated assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.110`.
- Store the value as the default PumpPower for subsequent test instances in the cycle.
- Add logging when PumpPower is initialized from the pump.
- Add logging at test start including test name, repetition number,
last repetition flag, and PumpPower to improve diagnostics.
- Store the value as the default PumpPower for subsequent test instances in the cycle.
- Add logging when PumpPower is initialized from the pump.
- Add logging at test start including test name, repetition number,
last repetition flag, and PumpPower to improve diagnostics.
- When STOP is pressed during PerformSteps() in the BeforeTest transition,
Transition() returned immediately and skipped the common shutdown logic.
This caused FM pumps and valves to remain in their previous state.
- Perform the required safe shutdown (FM pump off and default valve setup)
before returning UiCmdStop or Error.
- Introduce `TestMethod`, `SequenceConditionOp`, and `Factory` for `GenesisCommunication`.
- Add `TestMethodCfgCtrl` and its designer for test configuration UI.
- Update `.csproj` to include new files.
- Expand Q3 calibration tests with diverse scenarios in `GenesisSmartReader_Q3Test`.
- Introduce channel-specific validation for calibration tests.
- Adjust methods for Q3 calibration in `GenesisSmartReader` to support per-channel factors.
- Add utilities for preparing simulation data and refinements for test consistency.
- Update `CliRunner` with improved task management, timeout handling, and logging enhancements.