(1) Range of flow extended to 125%, (2) RequredFlowLo/Hi etc. float -> double, ver. 2.18.1192

This commit is contained in:
Milan Hanajik
2019-04-15 08:15:47 +02:00
parent 556290abf6
commit f8671ac516
16 changed files with 172 additions and 171 deletions
+13 -13
View File
@@ -18,9 +18,10 @@ namespace TBF.BenchControl.Elde
readonly int regulValveNr;
readonly int regulValveStableTime;
readonly int flowMeterNr;
readonly float nominalFlow;
readonly float reqFlowLo;
readonly float reqFlowHi;
readonly double nominalFlow;
readonly double maximalFlow;
readonly double reqFlowLo;
readonly double reqFlowHi;
readonly float pidCoef;
readonly int totalRefPulses; /// Number of reference pulses for a complete test
readonly int massRefPulses; /// Number of reference pulses for mass collection
@@ -28,8 +29,6 @@ namespace TBF.BenchControl.Elde
readonly int[] filters;
readonly int diverterNr;
bool started = false;
///
/// Internal states of this operation
///
@@ -54,7 +53,7 @@ namespace TBF.BenchControl.Elde
/// <param name="totalRefPulses">Test duration in number of reference flowmeter pulses</param>
/// <param name="filterConstant">Specifies filter for watermeter pulses</param>
public StartMeasurementOp(ControlBoardDev controlBoard, OutputPath outputPath, TestMethods method,
float requiredFlowLo, float requiredFlowHi,
double requiredFlowLo, double requiredFlowHi,
int refPulses, int[] filters)
: this(controlBoard, outputPath, method, requiredFlowLo, requiredFlowHi, refPulses, refPulses, filters)
{
@@ -70,7 +69,7 @@ namespace TBF.BenchControl.Elde
/// <param name="refPulses">Test duration in number of reference flowmeter pulses</param>
/// <param name="filterConstant">Specifies filter for watermeter pulses</param>
public StartMeasurementOp(ControlBoardDev controlBoard, OutputPath outputPath, TestMethods method,
float requiredFlowLo, float requiredFlowHi,
double requiredFlowLo, double requiredFlowHi,
int totalRefPulses, int massRefPulses, int[] filters)
{
if (controlBoard == null) throw new ArgumentNullException("controlBoardDev");
@@ -102,7 +101,8 @@ namespace TBF.BenchControl.Elde
diverterNr = (outputPath.Diverter as Elde.Diverter.Diverter).DiverterNr;
}
nominalFlow = (float)outputPath.FlowMeter.NominalFlow;
nominalFlow = outputPath.FlowMeter.NominalFlow;
maximalFlow = 1.25 * nominalFlow;
this.reqFlowLo = requiredFlowLo;
this.reqFlowHi = requiredFlowHi;
@@ -179,7 +179,7 @@ namespace TBF.BenchControl.Elde
///
/// Done once, issues an appropriate ValveMove(...) command
///
if (reqFlowLo >= reqFlowHi || reqFlowLo > nominalFlow || reqFlowHi <= 0)
if ((reqFlowLo >= reqFlowHi) || (reqFlowLo > maximalFlow) || (reqFlowHi <= 0))
{
return Event.OpArgumentError;
}
@@ -187,18 +187,18 @@ namespace TBF.BenchControl.Elde
log.InfoFormat("Run(): rv#={0} flowMtr#={1} TARGET: flowLo={2} flowHi={3}",
regulValveNr, flowMeterNr, reqFlowLo, reqFlowHi);
float freqLo = 2000.0f * reqFlowLo / nominalFlow;
float freqHi = 2000.0f * reqFlowHi / nominalFlow;
double freqLo = 2000.0 * reqFlowLo / nominalFlow;
double freqHi = 2000.0 * reqFlowHi / nominalFlow;
if (regulValve.IsCoax)
{
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
new float[2] { (freqLo + freqHi) / 2, (freqLo + freqHi) / 2 },
new float[2] { (float)((freqLo + freqHi) / 2), (float)((freqLo + freqHi) / 2) },
regulValveStableTime);
}
else
{
controlBoard.ValveMove(regulValveNr, RegulValveMode.TargetFrequency,
new float[2] { freqLo, freqHi },
new float[2] { (float)freqLo, (float)freqHi },
regulValveStableTime);
}