(1) Range of flow extended to 125%, (2) RequredFlowLo/Hi etc. float -> double, ver. 2.18.1192

This commit is contained in:
Milan Hanajik
2019-04-15 08:15:47 +02:00
parent 556290abf6
commit f8671ac516
16 changed files with 172 additions and 171 deletions
+2 -2
View File
@@ -9,7 +9,6 @@ namespace TBF.BenchControl.Elde
interface IControlCom
{
StatusP StatusP { get; }
float ReferenceFreq { get; }
int EtPulses(int wmNr1);
int EtPulsesK { get; }
UInt16 WMeterPulses(int wmNr1);
@@ -24,7 +23,8 @@ namespace TBF.BenchControl.Elde
float ImpulseTime(int WMNr1);
uint FmState { get; }
uint BeginState(int wmNr0);
float ReferenceFlow { get; }
double ReferenceFreq { get; }
double ReferenceFlow { get; }
float RValvePosition(int rvNr1);
float DivSamples(int time, int divIx0); /// time unit is 2 ms
int ScopeSamples(int i, int j, int k);