Heat meters : Prompt message does not stop the sequence, disappears when conditions met, ver. 2.10.359

This commit is contained in:
Milan Hanajik
2016-10-10 14:23:20 +02:00
parent 3c15dbab9e
commit f8331c1c1c
8 changed files with 119 additions and 82 deletions
@@ -106,22 +106,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
while (!e.Contains(Event.ValvesSet));
}
///
/// Display prompt to emerge temperature meters to appropriate baths for heat meters test
///
if (heatMetersTestParams != null && !string.IsNullOrEmpty(heatMetersTestParams.Prompt))
{
State.Create("FixedStartMassCollection : Show heat meters prompt (exchange temperature meters)")
.AddOperation(checkUiOp)
.AddOperation(new Operations.MessageBoxOp(heatMetersTestParams.Prompt))
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
}
while (!e.Contains(Event.OK));
}
///
/// Optionally display prompt to emerge temperature meters to appropriate baths for heat meters test
///
IOperation heatMetersPrompt = null;
if (heatMetersTestParams != null && !string.IsNullOrEmpty(heatMetersTestParams.Prompt))
{
heatMetersPrompt = new Operations.MessageBoxOp(heatMetersTestParams.Prompt);
}
if (inPath.Pump != null)
{
@@ -134,7 +127,8 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation(checkUiOp)
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.EnterState();
.AddOperation(heatMetersPrompt)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
@@ -153,7 +147,8 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.EnterState();
.AddOperation(heatMetersPrompt)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
@@ -172,7 +167,8 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.EnterState();
.AddOperation(heatMetersPrompt)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
@@ -189,7 +185,8 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation(checkUiOp)
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.EnterState();
.AddOperation(heatMetersPrompt)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
@@ -211,7 +208,8 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
.AddOperation(checkUiOp)
.AddOperation(StateMachine.ControlBoard.UpdateTankWeightOp())
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, 990)) /// timeout = 16.5 min.
.EnterState();
.AddOperation(heatMetersPrompt)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();
@@ -245,13 +243,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
double Tw_last = 0;
double Tc_last = 0;
State.Create("FixedStartMassCollection : Check temperature stabilized.")
State.Create("FlyingStartMassCollection : Check temperature stabilized.")
.AddOperation(checkUiOp)
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefWarm1))
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefWarm2))
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefCold1))
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefCold2))
.EnterState();
.AddOperation(heatMetersPrompt)
.EnterState();
do
{
e = StateMachine.WaitRunDevsRunOps();