TBF.BenchControl... --> TBF.Rig...
This commit is contained in:
@@ -0,0 +1,110 @@
|
||||
///
|
||||
/// Copyright (c) 2015-2017 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using System.Text;
|
||||
|
||||
namespace TBF.Rig.TestMethods.GenesisCommunication.GenesisHead
|
||||
{
|
||||
public enum MessageID
|
||||
{
|
||||
Calibration = 0x00, /// Access to stCalibration
|
||||
Configuration = 0x01, /// Access to stConfig
|
||||
Status = 0x02, /// Access to stStaus, read only
|
||||
Power = 0x03, /// Access to stPower, containing power info from both processors
|
||||
LCD = 0x04, /// Access to stLCD
|
||||
EventData = 0x05, /// NOT USED
|
||||
IntervalData = 0x06, /// NOT USED
|
||||
Diagnostics = 0x07, /// Access tostMetroDiagArray, read onl
|
||||
MetrologyMemory = 0x08, /// Memory block access, read only
|
||||
Error_LongAck = 0x09, /// Error message
|
||||
Command = 0x0A, /// Command to execute, with no arguments
|
||||
Parameterizing = 0x0B, /// Parameterizing message is used in MCI-SPI interface only
|
||||
Error_ShortAck = 0x0C, /// Short acknowledge message is used in MCI-SPI interface only
|
||||
ChanelAlive = 0x0D, /// Channel alive message is used in MCI-SPI interface only
|
||||
RadioPassthrough = 0x0E, /// RFID <-> Metrology <-> Radio passthrough message
|
||||
ASICRegisterReadTest = 0x0F, /// ASIC Register read test
|
||||
IMIDebugMessagesAccess = 0x10, /// IMI debug messages read test
|
||||
ProductionChecksumsRead = 0x11, /// Production checksum read: Calibration (1 byte), Configuration (2 bytes), spare (4 bytes)
|
||||
HardwareParametersTest = 0x12, /// Hardware Parameters Testing: User configurable fixed field drive time (1 byte)
|
||||
/// <summary>
|
||||
/// Notes:
|
||||
/// 1. Short Ack message contains 1-byte error code and all the fields (Offset, Payload length, payload and password) will not be present.
|
||||
/// 2. Channel Alive message does not contain the fields (Offset, Payload length, payload and password).
|
||||
/// 3. Except the above two special messages, rest all the messages in the above table will follow the message format mentioned in sections 3.1 and 3.2.
|
||||
/// </summary>
|
||||
Count /// Number of MessageID-s
|
||||
}
|
||||
|
||||
public enum MeterType : byte
|
||||
{
|
||||
DN15 = 0,
|
||||
CoaxManifold = 1,
|
||||
DN20 = 2,
|
||||
DN25 = 3,
|
||||
DN26 = 4, /// DN25*
|
||||
DN32 = 5,
|
||||
DN40 = 6,
|
||||
AutoDetect,
|
||||
Count /// Number of meter types
|
||||
}
|
||||
|
||||
public enum VolumeUnits : byte
|
||||
{
|
||||
m3 = 0,
|
||||
UK_gallon = 1,
|
||||
US_gallon = 2,
|
||||
Count /// Number of volume units
|
||||
}
|
||||
|
||||
public enum FlowArrow : byte
|
||||
{
|
||||
No = 0,
|
||||
Right = 1,
|
||||
Left = 2,
|
||||
Count /// Number of flow arrows
|
||||
}
|
||||
|
||||
public enum MeterSealed : byte
|
||||
{
|
||||
InProduction = 0x00,
|
||||
OutOfProduction = 0xA5,
|
||||
Sealed = 0x5A,
|
||||
}
|
||||
|
||||
public enum MeterState : byte
|
||||
{
|
||||
None = 0,
|
||||
Idle = 1,
|
||||
Active = 2,
|
||||
Test = 3,
|
||||
EndOfLife = 4,
|
||||
Count /// Number of meter states
|
||||
}
|
||||
|
||||
public enum FlowState : byte
|
||||
{
|
||||
No = 0,
|
||||
Reverse = 1,
|
||||
Forward = 2,
|
||||
EmptyPipe = 3,
|
||||
Count /// Number of flow states
|
||||
}
|
||||
|
||||
public enum OptoTelegramFlags : byte
|
||||
{
|
||||
OK = 0,
|
||||
OK_TestStart,
|
||||
OK_TestEnd,
|
||||
InvalidTelegram, /// Wrong telegram format of checksum error
|
||||
SyncError,
|
||||
}
|
||||
|
||||
public enum OptoState
|
||||
{
|
||||
Read,
|
||||
Flush,
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user