DummySeq modified, no message, temperature, pressure measured once, start/end time set, ver. 3.1.1618
This commit is contained in:
@@ -28,37 +28,59 @@ namespace TBF.Rig.TestMethods.Dummy
|
||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||
|
||||
/// Start the test, initialize test results
|
||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath));
|
||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||
TestStartTime = DateTime.Now;
|
||||
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||
if (outPath.TempMtrDiv != null) readTempPressOps.Add(outPath.TempMtrDiv.ReadTempOp(ref TempDiv));
|
||||
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||
|
||||
///
|
||||
/// Show a dialog with OK button and an appropriate message
|
||||
///
|
||||
Bridge.OnAdjustmentInProgress(this, new AdjustmentInProgressEventArgs(testName));
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||
Bridge.OnActivity(this, test.Method);
|
||||
State.Create(string.Format("{0}({1}) : Dummy", test.Method, test.Name))
|
||||
/// Start the test, initialize test results
|
||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath));
|
||||
|
||||
StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, 0);
|
||||
|
||||
/// Read pressure and temperature once
|
||||
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperation(StateMachine.BenchWaitingOp)
|
||||
.AddOperation(new Operations.MessageBoxOp(string.Format("Dummy test {0}", test.Name)))
|
||||
.AddOperations(readTempPressOps)
|
||||
.EnterState();
|
||||
do
|
||||
{
|
||||
do {
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.Error)) return new List<Event> { Event.Error };
|
||||
if (TestAndLogUiCmdStop(test, e)) return new List<Event> { Event.UiCmdStop };
|
||||
}
|
||||
while (e.Contains(Event.Busy));
|
||||
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, 1, Config.Entities.Progress.Test));
|
||||
StopRecordingStatistics();
|
||||
|
||||
if (e.Contains(Event.Error)) goto stopTest;
|
||||
if (TestAndLogUiCmdStop(test, e)) goto stopTest;
|
||||
/// Populate TestResult data entity with data
|
||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||
Results.Entities.TestRslt tstRslt = BatchRslts.GetTestRslt(testName, test.Part);
|
||||
if (tstRslt != null)
|
||||
{
|
||||
Results.Utils.GetCounterStates(tstRslt, Program.LocalSettings.Counters);
|
||||
UpdateTempPressDensAmb(tstRslt);
|
||||
|
||||
tstRslt.MethodClass = TbfComponents.FindComponent(test.Method).ClassName;
|
||||
tstRslt.StartTime = DateTime.Now;
|
||||
tstRslt.EndTime = DateTime.Now;
|
||||
tstRslt.TestDone = true;
|
||||
|
||||
for (int i = 0; i < BatchRslts.WMPositionsCount; i++)
|
||||
{
|
||||
Results.Entities.MeterTestRslt meterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Single);
|
||||
meterRslt.TestDone = true;
|
||||
meterRslt.Passed = true;
|
||||
}
|
||||
}
|
||||
while (!e.Contains(Event.OK));
|
||||
|
||||
return new List<Event> { Event.Done };
|
||||
|
||||
stopTest:
|
||||
return new List<Event> { Event.UiCmdStop };
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user