DB 3.6 -> 3.7, PulsesPerLtrAux added to WaterMeterData and to Results items, MainSeqUtils and ProcedureDlg changes, ver. 3.7.2088

This commit is contained in:
Milan Hanajik
2023-08-17 19:57:58 +02:00
parent bc0de96ad9
commit eaf60f3292
10 changed files with 133 additions and 34 deletions
+28
View File
@@ -386,5 +386,33 @@ namespace TBF.UI.Settings
upgradeDb_305_306_Button.Enabled = false;
}
}
private void upgradeDb_306_307_Button_Click(object sender, EventArgs e)
{
string[] configDbCommands = new string[] { };
string[] resultsDbCommands = new string[]
{
"ALTER TABLE `watermeterdata` ADD `PulsesPerLtrAux` DOUBLE NOT NULL DEFAULT '1' AFTER `ApprovalInfoAux`;",
};
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
{
MessageBox.Show("No database selected");
return;
}
ActivityStart();
if ((!upgradeConfigDBCheckBox.Checked || configDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(TBF.DB.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
(!upgradeResultsDBCheckBox.Checked || resultsDbCommands.Length == 0 ||
ExecuteCommands(new MySqlConnection(Results.DB.ConnectionString), resultsDbCommands)))
{
ActivityEnd();
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
upgradeDb_306_307_Button.Enabled = false;
}
}
}
}