diff --git a/TBF/BenchControl/Output/DB/SensusOracle/Database.cs b/TBF/BenchControl/Output/DB/SensusOracle/Database.cs
index 1c9722fba..7f42feff1 100644
--- a/TBF/BenchControl/Output/DB/SensusOracle/Database.cs
+++ b/TBF/BenchControl/Output/DB/SensusOracle/Database.cs
@@ -31,8 +31,19 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
public enum WMKind
{
- Iperl,
- S620,
+ iPERL,
+ Mechanical,
+ Count
+ }
+
+ ///
+ /// Test/Q designation mode for IperlLogger and IperlHead opto data files
+ ///
+ public enum DesigMode
+ {
+ Auto,
+ Based_on_procedure,
+ As_specified,
Count
}
@@ -42,18 +53,19 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
private static readonly ILog log = LogManager.GetLogger(typeof(Database));
public override string ToString() { return string.Format("{0}({1})", GetType().Namespace.Substring(17), Cfg.ToString(1)); }
- const int Anbid_StaraTura = 4;
+ public const int Anbid_StaraTura = 4;
DatabaseCfg dbCfg;
public DBUsed DBUsed { get { return (dbCfg == null || dbCfg.ProcParams == null) ? DBUsed.None : dbCfg.ProcParams.DBUsed; } }
- public WMKind WMKind { get { return (dbCfg == null || dbCfg.ProcParams == null) ? WMKind.Iperl : dbCfg.ProcParams.WMKind; } }
+ public WMKind WMKind { get { return (dbCfg == null || dbCfg.ProcParams == null) ? WMKind.iPERL : dbCfg.ProcParams.WMKind; } }
public int WMTypeId { get { return (dbCfg == null || dbCfg.ProcParams == null) ? 0 : dbCfg.ProcParams.WMTypeId; } }
public int YearOfManufacture { get { return (dbCfg == null || dbCfg.ProcParams == null) ? DateTime.Now.Year : dbCfg.ProcParams.YearOfManufacture; } }
public bool SaveResults { get { return (dbCfg == null || dbCfg.ProcParams == null) ? false : dbCfg.ProcParams.SaveResults; } }
public bool ReadStartInfo { get { return (dbCfg == null || dbCfg.ProcParams == null) ? true : dbCfg.ProcParams.ReadStartInfo; } }
public bool StartInfoIsRequired { get { return (dbCfg == null || dbCfg.ProcParams == null) ? false : dbCfg.ProcParams.StartInfoIsRequired; } }
-
+ public DesigMode DesigMode { get { return (dbCfg == null || dbCfg.ProcParams == null) ? DesigMode.Auto : dbCfg.ProcParams.DesigMode; } }
+ public LogType DesigType { get { return (dbCfg == null || dbCfg.ProcParams == null) ? LogType.Just_Q3Q2Q1 : dbCfg.ProcParams.DesigType; } }
enum OpState
{
@@ -83,17 +95,15 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
OracleConnection qualityDB; /// Quality Oracle DB connection
OracleConnection testDB; /// Test Oracle DB connection
- OracleConnection selectedDB
+ public OracleConnection SelectedDB
{
get
{
- if (dbCfg == null || dbCfg.ProcParams == null) return null;
-
- switch (dbCfg.ProcParams.DBUsed)
+ switch (DBUsed)
{
case DBUsed.Production: return productionDB;
- case DBUsed.Quality: return qualityDB;
- case DBUsed.Test: return testDB;
+ case DBUsed.Quality: return qualityDB;
+ case DBUsed.Test: return testDB;
default:
case DBUsed.None:
@@ -120,7 +130,7 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
{
dbCfg = cfg as DatabaseCfg;
currentOpState = OpState.None;
- log.Debug(this.ToString());
+ log.Warn(this.ToString());
}
///
@@ -128,26 +138,26 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
///
public void Initialize()
{
+ if (dbCfg.DebugLevel == DebugMode.Simulate) return;
+
productionDB = new OracleConnection("Data Source=STARA01.WORLD;User Id=deltachef;Password=deltachef;");
qualityDB = new OracleConnection("Data Source=STARA01.WORLD;User Id=deltaqual;Password=test;");
testDB = new OracleConnection("Data Source=STARA_TEST.WORLD;User Id=deltachef;Password=deltachef;");
- if (dbCfg.DebugLevel == DebugMode.Simulate) return;
-
///
/// Do something with the database to see if the connection works well
///
- if (productionDB != null)
+ if (DBUsed == DBUsed.Production)
{
- productionDB.Open();
+ SelectedDB.Open();
string rslt = "none";
- OracleCommand cmd = new OracleCommand("select Standort from ANBIETER_SD where ANBID = 4", productionDB);
+ OracleCommand cmd = new OracleCommand("SELECT standort FROM anbieter_sd WHERE anbid = 4", SelectedDB);
OracleDataReader dr = cmd.ExecuteReader();
if (dr.Read()) rslt = dr.GetString(0);
dr.Close();
- productionDB.Close();
+ SelectedDB.Close();
}
}
///
@@ -188,8 +198,10 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
q3 = 0;
timeStamp = DateTime.MinValue;
remark = string.Empty;
-
- OracleCommand cmd = new OracleCommand("select REV_WZTYP, WZTYP, METROLKLASSE, ZULASSZEICHEN, MATERIALNR, QMAX, AENDERUNGSDATUM, BEMERKUNG from VT_WZTYP_SD where ANBID=4 and ID_WZTyp=:1 and AKTIV=:2", conn);
+
+ OracleCommand cmd = new OracleCommand("SELECT rev_wztyp, wztyp, metrolklasse, zulasszeichen, materialnr, qmax, aenderungsdatum, bemerkung " +
+ "FROM vt_wztyp_sd " +
+ "WHERE anbid=4 AND id_wztyp=:1 AND aktiv=:2", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeId }); ///:1
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 1 }); ///:2
///
@@ -209,7 +221,9 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
if (wmTypeRevision == -1) return null; /// No 'wmTypeRevision' found
- cmd = new OracleCommand("select PRUEFUNGSNR, Q_SOLL, PRUEFZEIT, POSFEHLERKALT, NEGFEHLERKALT, PRUEFBEREICHMIN, PRUEFBEREICHMAX, QBEZEICHNUNG from VT_PRUEFPUNKT_SOLL_SD where ANBID=4 and ID_WZTyp=:1 and Rev_WZTyp=:2", conn);
+ cmd = new OracleCommand("SELECT pruefungsnr, q_soll, pruefzeit, posfehlerkalt, negfehlerkalt, pruefbereichmin, pruefbereichmax, qbezeichnung " +
+ "FROM vt_pruefpunkt_soll_sd " +
+ "WHERE anbid=4 AND id_wztyp=:1 AND rev_wztyp=:2", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeId }); ///:1
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeRevision }); ///:2
///
@@ -253,11 +267,7 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
/// Reference to the operation
public IOperation ReadStartInfoOp(IList waterMeters)
{
- if (!ReadStartInfo)
- {
- return null;
- }
- else if ((currentOpState == OpState.ReadStartInfoRunning) || (currentOpState == OpState.WriteResultsRunning))
+ if ((currentOpState == OpState.ReadStartInfoRunning) || (currentOpState == OpState.WriteResultsRunning))
{
throw new Exception("Sequence error");
}
@@ -317,15 +327,25 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
{
if (!opCompleted)
{
- if (waterMeters.Count == 0) return Event.ResultsWritten;
+ log.WarnFormat("{0} : Run() : currentOp = {1}", Name, currentOpState);
- if ((dbCfg.DebugLevel == DebugMode.Normal) && (selectedDB != null))
+ if (dbCfg.DebugLevel == DebugMode.Normal && SelectedDB != null && ReadStartInfo && waterMeters.Count != 0)
{
- log.WarnFormat("{0} : Run() : currentOp = {1}", Name, currentOpState);
#if ORACLE_DB
- if (ReadStartInfoFromDB(selectedDB) == Retv.Error) anyError = true;
+ log.WarnFormat("{0} : Run() : reading from database", Name);
+ if (ReadStartInfoFromDB(SelectedDB) == Retv.Error) anyError = true;
#endif
}
+
+ if (DesigMode == DesigMode.Based_on_procedure && StateMachine.Procedure != null)
+ {
+ Sequences.ProcessData.CompleteTestInfos = Results.Output.SensusTestInfo.CreateFromProcedure(StateMachine.Procedure);
+ }
+ else if (DesigMode == DesigMode.As_specified && DesigType >= 0 && DesigType < LogType.Count)
+ {
+ Sequences.ProcessData.CompleteTestInfos = SensusTestInfo.GetTestInfos(DesigType);
+ }
+
opCompleted = true;
}
@@ -337,11 +357,11 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
{
if (batch.WaterMeters.Count == 0) return Event.ResultsWritten;
- if ((dbCfg.DebugLevel == DebugMode.Normal) && (selectedDB != null))
+ if ((dbCfg.DebugLevel == DebugMode.Normal) && (SelectedDB != null))
{
log.WarnFormat("{0} : Run() : currentOp = {1}", Name, currentOpState);
#if ORACLE_DB
- if (WriteResultsToDB(selectedDB, batch, false) == Retv.Error) anyError = true;
+ if (WriteResultsToDB(SelectedDB, batch, false) == Retv.Error) anyError = true;
#endif
}
opCompleted = true;
@@ -478,7 +498,6 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
OracleCommand cmd;
OracleDataReader dr;
- // SELECT * FROM VT_ZAEHLER_PD WHERE VT_Fernum = :1 AND ANBID = 4
int maxPruefindex = 0;
string purchaseOrder = string.Empty;
int assignedSerialNr = 0;
@@ -499,8 +518,10 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
///
/// Read data from VT_ZAEHLER_PD
///
- cmd = new OracleCommand("select MAX_PRUEFINDEX, AUFTRAGSNUMMER, ZAEHLERNUMMER, PALETTE_NR, UMKARTON_NR, Z_NR_KOMPLETT, VT_MODUL_SNR from VT_ZAEHLER_PD where VT_FERNUM = :1 AND ANBID = 4", conn);
- /// 100*benchId+MPix, purchase_order, assigned_s/n, palette_nr, box_nr., complete_s/n, radio_address
+ /// 100*benchId+MPix, purchase_order, assigned_s/n, palette_nr, box_nr., complete_s/n, radio_address
+ cmd = new OracleCommand("SELECT max_pruefindex, auftragsnummer, zaehlernummer, palette_nr, umkarton_nr, z_nr_komplett, vt_modul_snr " +
+ "FROM vt_zaehler_pd " +
+ "WHERE vt_fernum = :1 AND anbid = 4", conn);
cmd.Parameters.Add(new OracleParameter { ParameterName = "1", OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
dr = cmd.ExecuteReader();
if (dr.Read())
@@ -530,8 +551,10 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
///
/// Read data from VT_ZAEHLER_PINDEX_PD
///
- cmd = new OracleCommand("select PRUEFINDEX, ID_WZPRUEFREIHE, WT_PLATZ_NR, WZGUT, ID_BENUTZER from VT_ZAEHLER_PINDEX_PD where VT_FERNUM = :1 AND ANBID = 4", conn);
- /// test_bench_ID, line_ID, WM_position, result, user_ID
+ /// test_bench_ID, line_ID, WM_position, result, user_ID
+ cmd = new OracleCommand("SELECT pruefindex, id_wzpruefreihe, wt_platz_nr, wzgut, id_benutzer " +
+ "FROM vt_zaehler_pindex_pd " +
+ "WHERE vt_fernum = :1 AND anbid = 4", conn);
cmd.Parameters.Add(new OracleParameter { ParameterName = "1", OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
dr = cmd.ExecuteReader();
while (dr.Read())
@@ -551,8 +574,10 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
///
/// Read data from VT_IP_ZAEHLER_PINDEX_PD
///
- cmd = new OracleCommand("select PRUEFINDEX, Q2CORRECTIONLEFT, Q2CORRECTIONRIGHT, ERRQ2 from VT_IP_ZAEHLER_PINDEX_PD where VT_FERNUM = :1 AND ANBID = 4", conn);
/// pruefindex, Q2_correction_RL, Q2_correction_LR, Q2_error_before_correction
+ cmd = new OracleCommand("SELECT pruefindex, q2correctionleft, q2correctionright, errq2 " +
+ "FROM vt_ip_zaehler_pindex_pd " +
+ "WHERE vt_fernum = :1 AND anbid = 4", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
dr = cmd.ExecuteReader();
while (dr.Read())
@@ -572,7 +597,9 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
/// Read data from VT_PRUEFREIHE_IST_PD
///
/// testID, flow, rel.err., passed
- cmd = new OracleCommand("select PRUEFUNGSNR, Q_WZ, Q_FEHLER, Q_BEST from VT_PRUEFREIHE_IST_PD where VT_FERNUM = :1 AND PRUEFINDEX = :2 AND ANBID = 4", conn);
+ cmd = new OracleCommand("SELECT pruefungsnr, q_wz, q_fehler, q_best " +
+ "FROM vt_pruefreihe_ist_pd " +
+ "WHERE vt_fernum = :1 AND pruefindex = :2 AND anbid = 4", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 100 * testBenchID + maxPruefindex });
@@ -679,17 +706,17 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
SaveBatchData(conn, batch);
foreach (var wMtr in batch.WaterMeters)
{
- if (WMKind == WMKind.Iperl)
+ if (WMKind == WMKind.iPERL)
{
if ((wMtr.ErrorFlags & ((int)ErrorFlagMask.E26 | (int)ErrorFlagMask.E27 | (int)ErrorFlagMask.E28)) == 0)
{
/// No production error => write the result of testing to Oracle DB
- SaveOneIperlToDB(conn, wMtr, safeMode);
+ SaveIperlToDB(conn, wMtr, safeMode);
}
}
- else if (WMKind == WMKind.S620)
+ else if (WMKind == WMKind.Mechanical)
{
- SaveOneS620ToDB(conn, wMtr, safeMode);
+ SaveMechanicalMeterToDB(conn, wMtr, safeMode);
}
}
@@ -719,7 +746,7 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
IList pruefindexes = new List();
{
- OracleCommand cmd = new OracleCommand("SELECT Pruefindex FROM VT_ZAEHLER_PINDEX_PD WHERE VT_Fernum = :1 AND ANBID = 4", conn);
+ OracleCommand cmd = new OracleCommand("SELECT pruefindex FROM vt_zaehler_pindex_pd WHERE vt_fernum = :1 AND anbid = 4", conn);
OracleParameter parm = new OracleParameter();
parm.OracleDbType = OracleDbType.Varchar2;
@@ -733,8 +760,11 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
}
}
{
- OracleCommand cmd = new OracleCommand("SELECT Max_Pruefindex, Auftragsnummer, Z_Nr_Komplett, VT_Modul_Snr FROM VT_ZAEHLER_PD WHERE VT_Fernum = :1 AND ANBID = 4", conn);
- /// purchase order assigned s/n radio address PCB number Producer ID
+ /// purchase order assigned s/n radio address
+ OracleCommand cmd = new OracleCommand("SELECT max_pruefindex, auftragsnummer, z_nr_komplett, vt_modul_snr " +
+ "FROM vt_zaehler_pd " +
+ "WHERE vt_fernum = :1 AND anbid = 4", conn);
+ /// PCB number Producer ID
OracleParameter parm = new OracleParameter();
parm.OracleDbType = OracleDbType.Varchar2;
parm.Value = wm.SerialNr;
@@ -814,11 +844,11 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
if (!dbCfg.TestMode)
{
- OracleCommand cmd = new OracleCommand("INSERT INTO VT_PRUEFREIHE_PD(ANBID, ID_Pruefstand, ID_WzPruefreihe, ID_WZTyp, " +
- "Rev_WZTyp, Rev_Pruefstand_WZTyp, StartDatumZeit, EndDatumZeit, Betriebsart, " +
- "QVzKontakt, FuellenBegDruck, DruckEvakVorne, DruckEvakHinten, DruckBeiAbpressen, " +
- "Druckentwaessern, SpuelDurchflussIst, ProgrammVersion)" +
- " VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17)", conn);
+ OracleCommand cmd = new OracleCommand("INSERT INTO vt_pruefreihe_pd(anbid, id_pruefstand, id_wzpruefreihe, id_wztyp," +
+ " rev_wztyp, rev_pruefstand_wztyp, startdatumzeit, enddatumzeit, betriebsart," +
+ " qvzkontakt, fuellenbegdruck, druckevakvorne, druckevakhinten, druckbeiabpressen," +
+ " druckentwaessern, spueldurchflussist, programmversion) " +
+ "VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 18000 + b.TestBenchId });
@@ -860,9 +890,9 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
if (!dbCfg.TestMode)
{
#if false
- OracleCommand cmd2 = new OracleCommand("INSERT INTO VT_PRUEFDURCHFLUSS_PD(ANBID, ID_Pruefstand, ID_WzPruefreihe, PruefungsNr, PVOL, PMasse, " +
- "MinDurchfluss, MaxDurchfluss, Q_ist, KFaktor, Q_VZ, F_VZ, RegelEinstellZeit, Drehzahl, BeginnDruck_Vorne, " +
- "BeginnDruck_Hinten, EndDruck_Vorne, EndDruck_Hinten, TVWZ, IVWZ, Verwendeter_VZ, BeginnGewicht, EndGewicht) " +
+ OracleCommand cmd2 = new OracleCommand("INSERT INTO vt_pruefdurchfluss_pd(anbid, id_pruefstand, id_wzpruefreihe, pruefungsnr, pvol, pmasse," +
+ " mindurchfluss, maxdurchfluss, q_ist, kfaktor, q_vz, f_vz, regeleinstellzeit, drehzahl, beginndruck_vorne," +
+ " beginndruck_hinten, enddruck_vorne, enddruck_hinten, tvwz, ivwz, verwendeter_vz, beginngewicht, endgewicht) " +
"VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17, :18, :19, :20, :21, :22, :23)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
@@ -891,14 +921,11 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Units.ConvertTo(Unit.kg, tr.MassEnd) });
cmd2.ExecuteNonQuery(); /// Returns nr. of updated rows
#else
- OracleCommand cmd2 = new OracleCommand("INSERT INTO VT_PRUEFDURCHFLUSS_PD(" +
- "ANBID, ID_Pruefstand, ID_WzPruefreihe, PruefungsNr, " +
- "PVOL, PMasse, MinDurchfluss, MaxDurchfluss, " +
- "Q_ist, KFaktor, Q_VZ, F_VZ, RegelEinstellZeit, Drehzahl, " +
- "BeginnDruck_Vorne, BeginnDruck_Hinten, EndDruck_Vorne, EndDruck_Hinten, " +
- "TVWZ, IVWZ, Verwendeter_VZ, BeginnGewicht, EndGewicht)" +
- " VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, " +
- ":16, :17, :18, :19, :20, :21, :22, :23)", conn);
+ var cmd2 = new OracleCommand("INSERT INTO vt_pruefdurchfluss_pd(anbid, id_pruefstand, id_wzpruefreihe, pruefungsnr," +
+ " pvol, pmasse, mindurchfluss, maxdurchfluss, q_ist, kfaktor, q_vz, f_vz, regeleinstellzeit," +
+ " drehzahl, beginndruck_vorne, beginndruck_hinten, enddruck_vorne, enddruck_hinten," +
+ " tvwz, ivwz, verwendeter_vz, beginngewicht, endgewicht) " +
+ "VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17, :18, :19, :20, :21, :22, :23)", conn);
OracleParameter parm;
parm = new OracleParameter("ANBID", OracleDbType.Int32); parm.Value = Anbid_StaraTura; cmd2.Parameters.Add(parm); ///:1
parm = new OracleParameter("ID_Pruefstand", OracleDbType.Int32); parm.Value = 18000 + b.TestBenchId; cmd2.Parameters.Add(parm); ///:2
@@ -948,7 +975,7 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
///
/// 0-based water meter number
/// Sorted list of results to save
- void SaveOneIperlToDB(OracleConnection conn, Results.Entities.WaterMeter wm, bool safeMode)
+ void SaveIperlToDB(OracleConnection conn, Results.Entities.WaterMeter wm, bool safeMode)
{
if (safeMode && !wm.Passed) return;
@@ -989,9 +1016,9 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
{
if (!dbCfg.TestMode)
{
- OracleCommand cmd = new OracleCommand("INSERT INTO VT_ZAEHLER_PD(Auftragsnummer, VT_Identnummer, VT_Fernum, Max_Pruefindex," +
- " Zaehlernummer, Sekundaere_Adr, Hydr_Pruefung, ID_Benutzer, ANBID, Baujahr)" +
- " VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10)", conn);
+ OracleCommand cmd = new OracleCommand("INSERT INTO vt_zaehler_pd(auftragsnummer, vt_identnummer, vt_fernum, max_pruefindex," +
+ " zaehlernummer, sekundaere_adr, hydr_pruefung, id_benutzer, anbid, baujahr) " +
+ "VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "IPBATMXX" });
@@ -1016,7 +1043,9 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
{
if (!dbCfg.TestMode)
{
- OracleCommand cmd = new OracleCommand("UPDATE VT_ZAEHLER_PD SET Auftragsnummer = :1, VT_Identnummer = :2, Max_Pruefindex = :3, Hydr_Pruefung= :4, ID_Benutzer= :5, Baujahr= :6 WHERE VT_Fernum = :7 and ANBID = :8", conn);
+ OracleCommand cmd = new OracleCommand("UPDATE vt_zaehler_pd " +
+ "SET auftragsnummer=:1, vt_identnummer=:2, max_pruefindex=:3, hydr_pruefung=:4, id_benutzer=:5, baujahr=:6 " +
+ "WHERE vt_fernum = :7 AND anbid = :8", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "IPBATMXX" });
@@ -1038,11 +1067,11 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
if (!dbCfg.TestMode)
{
- OracleCommand cmd = new OracleCommand("INSERT INTO VT_ZAEHLER_PINDEX_PD(" +
- "VT_Fernum, Pruefindex, ANBID, ID_Pruefstand, ID_WzPruefreihe, Hydr_Pruefung, " +
- "ReedKontakt, ReedKontaktOK, ReedKontaktZeit, KorrImprate, FestWertWZ, PtestOK, " +
- "Zaehlerstand, WT_Platz_NR, WZgut, ID_Benutzer, AnzahlPruefungen)" +
- " VALUES (:1, :2, :3, :4, :5, :6, 0, 0, 0, :7, 0, :8, 0, :9, :10, :11, :12)", conn); /// ReedKontakt = ReedKontaktOK = ReedKontaktZeit = FestWertWZ = Zaehlerstand = 0
+ OracleCommand cmd = new OracleCommand("INSERT INTO vt_zaehler_pindex_pd(vt_fernum, pruefindex, anbid," +
+ " id_pruefstand, id_wzpruefreihe, hydr_pruefung, reedkontakt," +
+ " reedkontaktok, reedkontaktzeit, korrimprate, festwertwz, ptestok," +
+ " zaehlerstand, wt_platz_nr, wzgut, id_benutzer, anzahlpruefungen) " +
+ "VALUES (:1, :2, :3, :4, :5, :6, 0, 0, 0, :7, 0, :8, 0, :9, :10, :11, :12)", conn); /// ReedKontakt = ReedKontaktOK = ReedKontaktZeit = FestWertWZ = Zaehlerstand = 0
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
@@ -1113,10 +1142,10 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
{
double q2ErrWOCorrection = Math.Min(100.0, Math.Max(-100.0, wm.Q2ErrWOCorrection));
- OracleCommand cmd = new OracleCommand("INSERT INTO VT_IP_ZAEHLER_PINDEX_PD(" +
- "VT_Fernum, Pruefindex, ANBID, WITHCORRECTION2HZ, CORRECTION2HZ, DIFF2HZ8HZ, " +
- "WITHQ2CORRECTION, Q2CORRECTIONRIGHT, ERRQ2, Q2CORRECTIONFLOWRIGHT, Q2CORRECTIONLEFT)" +
- " VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11)", conn);
+ OracleCommand cmd = new OracleCommand("INSERT INTO vt_ip_zaehler_pindex_pd(vt_fernum, pruefindex, anbid," +
+ " withcorrection2hz, correction2hz, diff2hz8hz, withq2correction," +
+ " q2correctionright, errq2, q2correctionflowright, q2correctionleft) " +
+ "VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11)", conn);
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
@@ -1141,11 +1170,11 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
///
- /// Write one meter results into the database
+ /// Write results of one mechanical meter into the database
///
/// 0-based water meter number
/// Sorted list of results to save
- void SaveOneS620ToDB(OracleConnection conn, Results.Entities.WaterMeter wm, bool safeMode)
+ void SaveMechanicalMeterToDB(OracleConnection conn, Results.Entities.WaterMeter wm, bool safeMode)
{
if (safeMode && !wm.Passed) return;
@@ -1174,32 +1203,41 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
wm.Pruefindex = MAX_Pruefindex;
wm.HydrPruefung = Hydr_Pruefung;
- SaveOrUpdateS620(conn, wm, MAX_Pruefindex, Hydr_Pruefung);
+ SaveOrUpdateMechanicalMeter(conn, wm, MAX_Pruefindex, Hydr_Pruefung);
}
- void SaveOrUpdateS620(OracleConnection conn, Results.Entities.WaterMeter wm, int max_Pruefindex, int hydr_Pruefung)
+ void SaveOrUpdateMechanicalMeter(OracleConnection conn, Results.Entities.WaterMeter wm, int max_Pruefindex, int hydr_Pruefung)
{
- int sekundaere_Adr = wm.Passed ? 1 : 0;
int idBenutzer = 6; // = wm.Batch.UserNumber;
if (max_Pruefindex % 100 == 1)
{
if (!dbCfg.TestMode)
{
- OracleCommand cmd = new OracleCommand("INSERT INTO VT_ZAEHLER_PD(Auftragsnummer, VT_Identnummer, VT_Fernum, Max_Pruefindex," +
- " Zaehlernummer, Sekundaere_Adr, Hydr_Pruefung, ID_Benutzer, ANBID, Baujahr)" +
- " VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10)", conn);
+ OracleCommand cmd = new OracleCommand("INSERT INTO vt_zaehler_pd(auftragsnummer, vt_identnummer, vt_fernum, max_pruefindex," +
+ " mbus_adr, liegenschafts_nr, sekundaere_adr, hydr_pruefung, mark_date, baujahr, eich_jahr," +
+ " umkarton_nr, palette_nr, zaehlernummer, prefix, suffix, z_nr_komplett, anbid, id_benutzer) " +
+ "VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17, :18, :19)", conn);
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "IPBATMXX" });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = -1 });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = sekundaere_Adr });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture });
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder }); /// :1
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "88888888" }); /// :2
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr }); /// :3
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex }); /// :4
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :5 MBUS_ADR
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :6 LIEGENSCHAFTS_NR
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :7 Sekundaere_Adr
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung }); /// :8
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.TimeStamp, Value = wm.Batch.EndTime }); /// :9
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture }); /// :10
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture }); /// :11
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :12 UMKARTON_NR
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :13 PALETTE_NR
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.AssignedSerialNr }); /// :14
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.Prefix }); /// :15
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.Suffix }); /// :16
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.CompleteSerialNr }); /// :17
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura }); /// :18
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer }); /// :19
cmd.ExecuteNonQuery();
log.InfoFormat("VT_ZAEHLER_PD inserted, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
@@ -1213,16 +1251,31 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
{
if (!dbCfg.TestMode)
{
- OracleCommand cmd = new OracleCommand("UPDATE VT_ZAEHLER_PD SET Auftragsnummer = :1, VT_Identnummer = :2, Max_Pruefindex = :3, Hydr_Pruefung= :4, ID_Benutzer= :5, Baujahr= :6 WHERE VT_Fernum = :7 and ANBID = :8", conn);
+ OracleCommand cmd = new OracleCommand("UPDATE vt_zaehler_pd " +
+ "SET auftragsnummer=:1, vt_identnummer=:2, max_pruefindex=:3, mbus_adr=:4, liegenschafts_nr=:5," +
+ " sekundaere_adr=:6, hydr_pruefung=:7, mark_date=:8, baujahr=:9, eich_jahr=:10, umkarton_nr=:11," +
+ " palette_nr=:12, zaehlernummer=:13, prefix=:14, suffix=:15, z_nr_komplett=:16, id_benutzer=:17 " +
+ "WHERE vt_fernum = :18 AND anbid = :19", conn);
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "IPBATMXX" });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.PurchaseOrder }); /// :1
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = "88888888" }); /// :2
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex }); /// :3
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :4 MBUS_ADR
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :5 LIEGENSCHAFTS_NR
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :6 Sekundaere_Adr
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = hydr_Pruefung }); /// :7
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.TimeStamp, Value = wm.Batch.EndTime }); /// :8
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture }); /// :9
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = YearOfManufacture }); /// :10
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :11 UMKARTON_NR
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :12 PALETTE_NR
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wm.AssignedSerialNr }); /// :13
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.Prefix }); /// :14
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.Suffix }); /// :15
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.CompleteSerialNr }); /// :16
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = idBenutzer }); /// :17
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr }); /// :18
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura }); /// :19
cmd.ExecuteNonQuery();
log.InfoFormat("VT_ZAEHLER_PD updated, PcbNr={0}, pos={1}, maxPruefix={2}", wm.SerialNr, wm.WMPosition, max_Pruefindex);
@@ -1235,11 +1288,10 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
if (!dbCfg.TestMode)
{
- OracleCommand cmd = new OracleCommand("INSERT INTO VT_ZAEHLER_PINDEX_PD(" +
- "VT_Fernum, Pruefindex, ANBID, ID_Pruefstand, ID_WzPruefreihe, Hydr_Pruefung, " +
- "ReedKontakt, ReedKontaktOK, ReedKontaktZeit, KorrImprate, FestWertWZ, PtestOK, " +
- "Zaehlerstand, WT_Platz_NR, WZgut, ID_Benutzer, AnzahlPruefungen)" +
- " VALUES (:1, :2, :3, :4, :5, :6, 0, 0, 0, :7, 0, :8, 0, :9, :10, :11, :12)", conn); /// ReedKontakt = ReedKontaktOK = ReedKontaktZeit = FestWertWZ = Zaehlerstand = 0
+ OracleCommand cmd = new OracleCommand("INSERT INTO vt_zaehler_pindex_pd(vt_fernum, pruefindex, anbid, id_pruefstand, id_wzpruefreihe," +
+ " hydr_pruefung, reedkontakt, reedkontaktok, reedkontaktzeit, korrimprate, festwertwz, ptestok," +
+ " zaehlerstand, wt_platz_nr, wzgut, id_benutzer, anzahlpruefungen) " +
+ "VALUES (:1, :2, :3, :4, :5, :6, 0, 0, 0, :7, 0, :8, 0, :9, :10, :11, :12)", conn); /// ReedKontakt = ReedKontaktOK = ReedKontaktZeit = FestWertWZ = Zaehlerstand = 0
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = wm.SerialNr });
cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
@@ -1320,27 +1372,26 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
if (!dbCfg.TestMode)
{
- OracleCommand cmd = new OracleCommand("INSERT INTO VT_PRUEFREIHE_IST_PD(" +
- "VT_Fernum, Pruefindex, PruefungsNr, ANBID, ID_WZTyp, Rev_WZTyp, Rev_WZPruefpunkt, " +
- "Q_WZ, Q_Fehler, Q_Best, NIZ, AnfangZStand, EndZStand, " +
- "KorrErrQok, KorrErrQ, KorrQWz, TIZ, Vol_WZ_US, TempMittel_US)" +
- " VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, 0, :14, 0, :15, 0, 0)", conn);
+ OracleCommand cmd = new OracleCommand("INSERT INTO vt_pruefreihe_ist_pd( vt_fernum, pruefindex, pruefungsnr, anbid," +
+ " id_wztyp, rev_wztyp, rev_wzpruefpunkt, q_wz, q_fehler, q_best, niz," +
+ " anfangzstand, endzstand, korrerrqok, korrerrq, korrqwz, tiz, vol_wz_us, tempmittel_us) " +
+ "VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, 0, :14, 0, :15, 0, 0)", conn);
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = mtr.WaterMeter.SerialNr });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = pruefungsNr });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = mtr.WaterMeter.WaterMeterData.WMTypeId });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeRevision });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 1 });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Q_wm_with_upper_bound });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100.0, Math.Max(-100.0, mtr.Error)) });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = mtr.Passed ? 1 : 0 });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Max(-99999.999, Math.Min(mtr.VolumeStart, 99999.999)) });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Max(-99999.999, Math.Min(mtr.VolumeEnd, 99999.999)) });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100.0, Math.Max(-100.0, mtr.KorrErrQ)) });
- cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100000, mtr.TestTime) });
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Varchar2, Value = mtr.WaterMeter.SerialNr }); /// :1 vt_fernum
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = max_Pruefindex }); /// :2 pruefindex
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = pruefungsNr }); /// :3 pruefungsnr
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = Anbid_StaraTura }); /// :4 anbid
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = mtr.WaterMeter.WaterMeterData.WMTypeId }); /// :5 id_wztyp
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = wmTypeRevision }); /// :6 rev_wztyp
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 1 }); /// :7 rev_wzpruefpunkt
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Q_wm_with_upper_bound }); /// :8 q_wz
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100.0, Math.Max(-100.0, mtr.Error)) }); /// :9 q_fehler
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = mtr.Passed ? 1 : 0 }); /// :10 q_best
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Int32, Value = 0 }); /// :11 niz
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Max(-99999.999, Math.Min(mtr.VolumeStart, 99999.999)) }); /// :12 anfangzstand
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Max(-99999.999, Math.Min(mtr.VolumeEnd, 99999.999)) }); /// :13 endzstand
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100.0, Math.Max(-100.0, mtr.KorrErrQ)) }); /// :14 korrerrq
+ cmd.Parameters.Add(new OracleParameter { OracleDbType = OracleDbType.Double, Value = Math.Min(100000, mtr.TestTime) }); /// :15 tiz
retv = cmd.ExecuteNonQuery();
log.DebugFormat("VT_PRUEFREIHE_IST_PD inserted, PcbNr={0}, pruefungsNr={1}, error={2}", mtr.WaterMeter.SerialNr, pruefungsNr, mtr.Error);
diff --git a/TBF/BenchControl/Output/DB/SensusOracle/ProcedureParams.cs b/TBF/BenchControl/Output/DB/SensusOracle/ProcedureParams.cs
index b30d71ecf..b1224b029 100644
--- a/TBF/BenchControl/Output/DB/SensusOracle/ProcedureParams.cs
+++ b/TBF/BenchControl/Output/DB/SensusOracle/ProcedureParams.cs
@@ -2,13 +2,14 @@
/// Copyright (c) 2020 Sensus Slovensko a.s.
///
using System;
+using System.Collections.Generic;
using System.IO;
using System.Text;
using System.Xml.Serialization;
using Config.Entities;
+using Results.Output;
using TBF.BenchControl.Generic;
using TBF.Resources;
-using System.Collections.Generic;
namespace TBF.BenchControl.Output.DB.SensusOracle
{
@@ -17,76 +18,87 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
public static XmlSerializer Serializer = XmlSerializer.FromTypes(new[] { typeof(ProcedureParams) })[0];
public override XmlSerializer GetSerializer() { return Serializer; }
- public DBUsed DBUsed; /// 0
- public WMKind WMKind; /// 1
- public int WMTypeId; /// 2
- public int YearOfManufacture; /// 3
- public bool SaveResults; /// 4
- public bool ReadStartInfo; /// 5
- public bool StartInfoIsRequired; /// 6
-
- public override void InitializeAll()
- {
- DBUsed = DBUsed.Production; /// 0
- WMKind = WMKind.Iperl; /// 1
- WMTypeId = 2; /// 2
- YearOfManufacture = DateTime.Now.Year; /// 3
-#if TURA_SPECIAL
- SaveResults = false; /// 4
-#else
- SaveResults = true; /// 4
-#endif
- ReadStartInfo = true; /// 5
- StartInfoIsRequired = false; /// 6
- }
+ public DBUsed DBUsed; /// 0
+ public WMKind WMKind; /// 1
+ public int WMTypeId; /// 2
+ public int YearOfManufacture; /// 3
+ public bool SaveResults; /// 4
+ public bool ReadStartInfo; /// 5
+ public bool StartInfoIsRequired; /// 6
+ public DesigMode DesigMode; /// 7
+ public Results.Output.LogType DesigType; /// 8
+
+ public override void InitializeAll()
+ {
+ DBUsed = DBUsed.Production; /// 0
+ WMKind = WMKind.iPERL; /// 1
+ WMTypeId = 2; /// 2
+ YearOfManufacture = DateTime.Now.Year; /// 3
+#if TURA_SPECIAL
+ SaveResults = false; /// 4
+#else
+ SaveResults = true; /// 4
+#endif
+ ReadStartInfo = true; /// 5
+ StartInfoIsRequired = false; /// 6
+ DesigMode = DesigMode.Auto; /// 7
+ DesigType = Results.Output.LogType.Just_Q3Q2Q1; /// 8
+ }
string[] paramNames = new string[]
{
- "Database", /// 0
- "Kind of WMs", /// 1
- "WM type ID", /// 2
- "Year of manufacture", /// 3
- "Save results", /// 4
- "Read start info", /// 5
- "Start info is required", /// 6
+ "Database", /// 0
+ "Kind of WMs", /// 1
+ "WM type ID", /// 2
+ "Year of manufacture", /// 3
+ "Save results", /// 4
+ "Read start info", /// 5
+ "Start info is required", /// 6
+ "Designation Mode", /// 7
+ "Designation when mode is 'As_specified'", /// 8
};
public override string ParamName(int i) { return paramNames[i]; }
public override int ParamsCount() { return paramNames.Length; }
public override IList ParamValues(int i)
{
- if (i == 0)
- {
- IList retVal = new List();
- for (DBUsed db = 0; db < DBUsed.Count; db++) retVal.Add(db.ToString());
- return retVal;
- }
+ IList retVal = new List();
- if (i == 1)
+ switch (i)
{
- IList retVal = new List();
- for (WMKind wm = 0; wm < WMKind.Count; wm++) retVal.Add(wm.ToString());
- return retVal;
- }
+ case 0:
+ for (DBUsed db = 0; db < DBUsed.Count; db++) retVal.Add(db.ToString());
+ return retVal;
- if (i == 3)
- {
- IList retVal = new List();
- int year = DateTime.Now.Year;
- retVal.Add(year.ToString());
- retVal.Add((year + 1).ToString());
- return retVal;
- }
+ case 1:
+ for (WMKind wm = 0; wm < WMKind.Count; wm++) retVal.Add(wm.ToString());
+ return retVal;
- if (i == 4 || i == 5 || i == 6)
- {
- IList retVal = new List();
- retVal.Add(Strings.yes);
- retVal.Add(Strings.no);
- return retVal;
- }
+ case 2:
+ default:
+ return null;
- return null;
+ case 3:
+ int year = DateTime.Now.Year;
+ retVal.Add(year.ToString());
+ retVal.Add((year + 1).ToString());
+ return retVal;
+
+ case 4:
+ case 5:
+ case 6:
+ retVal.Add(Strings.yes);
+ retVal.Add(Strings.no);
+ return retVal;
+
+ case 7:
+ for (DesigMode md = 0; md < DesigMode.Count; md++) retVal.Add(md.ToString());
+ return retVal;
+
+ case 8:
+ for (Results.Output.LogType wm = 0; wm < Results.Output.LogType.Count; wm++) retVal.Add(wm.ToString());
+ return retVal;
+ }
}
public override string ToString(int i)
@@ -100,6 +112,8 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
case 4: return SaveResults ? Strings.yes : Strings.no;
case 5: return ReadStartInfo ? Strings.yes : Strings.no;
case 6: return StartInfoIsRequired ? Strings.yes : Strings.no;
+ case 7: return DesigMode.ToString();
+ case 8: return DesigType.ToString();
default: return string.Empty;
}
}
@@ -136,7 +150,29 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
case 4: SaveResults = (strValue == Strings.yes); break;
case 5: ReadStartInfo = (strValue == Strings.yes); break;
case 6: StartInfoIsRequired = (strValue == Strings.yes); break;
- }
+
+ case 7:
+ for (DesigMode db = 0; db < DesigMode.Count; db++)
+ {
+ if (db.ToString() == strValue)
+ {
+ DesigMode = db;
+ return CfgUpdateFlags.None;
+ }
+ }
+ break;
+
+ case 8:
+ for (Results.Output.LogType wm = 0; wm < Results.Output.LogType.Count; wm++)
+ {
+ if (wm.ToString() == strValue)
+ {
+ DesigType = wm;
+ return CfgUpdateFlags.None;
+ }
+ }
+ break;
+ }
return CfgUpdateFlags.None;
}
@@ -180,6 +216,20 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
return true;
break;
+ case 7:
+ for (DesigMode db = 0; db < DesigMode.Count; db++)
+ {
+ if (db.ToString() == strValue) return true;
+ }
+ break;
+
+ case 8:
+ for (Results.Output.LogType wm = 0; wm < Results.Output.LogType.Count; wm++)
+ {
+ if (wm.ToString() == strValue) return true;
+ }
+ break;
+
default:
message = "Invalid index";
return false;
@@ -198,7 +248,9 @@ namespace TBF.BenchControl.Output.DB.SensusOracle
prms.SaveResults = this.SaveResults;
prms.ReadStartInfo = this.ReadStartInfo;
prms.StartInfoIsRequired = this.StartInfoIsRequired;
- }
+ prms.DesigMode = this.DesigMode;
+ prms.DesigType = this.DesigType;
+ }
public IParamsProvider Clone()
{