TestMethods.FlowAdjustment, TestMethods.FixedStartMassCollAdvanced, DataEntry24 changes, ver. 3.1.1471

This commit is contained in:
Milan Hanajik
2020-05-25 14:24:50 +02:00
parent 2ec611964f
commit e5edb90bfd
56 changed files with 2807 additions and 333 deletions
@@ -1,6 +1,10 @@
///
/// Copyright (c) 2013-2015 Sensus Metering Systems
///
using System;
using System.Collections.Generic;
using Results.Entities;
namespace TBF.BenchControl.GenericDevices
{
public interface IHasWMStatesForm
@@ -8,12 +12,16 @@ namespace TBF.BenchControl.GenericDevices
/// <summary>
/// Water meter states on start of test
/// </summary>
double WMStartState(int wmNr);
/// <param name="wmNr0">Zero based water meter number</param>
/// <returns>Water meter state in liters</returns>
double WMStartState(int wmNr0);
/// <summary>
/// Water meter states at the end of test
/// </summary>
double WMEndState(int wmNr);
/// <param name="wmNr0">Zero based water meter number</param>
/// <returns>Water meter state in liters</returns>
double WMEndState(int wmNr0);
/// <summary>
/// Displays form at the beginning of the test to enter water meter start start.
@@ -21,6 +29,12 @@ namespace TBF.BenchControl.GenericDevices
/// <returns>Operation to be used in the sequence</returns>
IOperation ShowTestStartFormOp(IRegisterReader[] regReaders);
/// <summary>
/// Displays form at the beginning of the test to enter water meter start start.
/// </summary>
/// <returns>Operation to be used in the sequence</returns>
IOperation ShowAdvancedTestStartFormOp(IRegisterReader[] regReaders, IList<WaterMeter> waterMeters);
/// <summary>
/// Displays form at the end of the test to enter water meter start start.
/// </summary>