diff --git a/TBF/Rig/GenericDevices/IScaleOrTank.cs b/TBF/Rig/GenericDevices/IScaleOrTank.cs
index bb2f7ece6..22b490dbd 100644
--- a/TBF/Rig/GenericDevices/IScaleOrTank.cs
+++ b/TBF/Rig/GenericDevices/IScaleOrTank.cs
@@ -12,11 +12,6 @@ namespace TBF.Rig.GenericDevices
///
public interface IScaleOrTank : IComponent
{
- ///
- /// Balance number: 0-based index required for communication with the Elde component
- ///
- int ScaleNr { get; }
-
///
/// Balance water tank capacity in kg or ltr
///
diff --git a/TBF/Rig/StateMachine.cs b/TBF/Rig/StateMachine.cs
index ae2184db5..df3b6f7c1 100644
--- a/TBF/Rig/StateMachine.cs
+++ b/TBF/Rig/StateMachine.cs
@@ -232,7 +232,6 @@ namespace TBF.Rig
/// Find all balances (to initialize tank capacities in the control board)
/// Find the control board
- IList tanks = new List();
UInt128 valvesToInvert = 0;
foreach (var cmpnt in components)
{
@@ -284,26 +283,12 @@ namespace TBF.Rig
if (cmpnt is ITestMethod && cmpnt.ClassName == "TestMethods.OuterLoop.Start") LoopStartNames.Add(cmpnt.Name);
if (cmpnt is ITestMethod && cmpnt.ClassName == "TestMethods.OuterLoop.End") LoopEndNames.Add(cmpnt.Name);
- if (cmpnt is IScaleOrTank)
- {
- IScaleOrTank tank = cmpnt as IScaleOrTank;
- tanks.Add(tank);
-
- if ((tank.ScaleNr == 0) && (Tank1 == null)) Tank1 = tank;
- else if ((tank.ScaleNr == 1) && (Tank2 == null)) Tank2 = tank;
- else if ((tank.ScaleNr == 2) && (Tank3 == null)) Tank3 = tank;
- }
-
BuiltIn.Valve.Valve plainValve = (cmpnt as BuiltIn.Valve.Valve);
if ((plainValve != null) && plainValve.Inverted) valvesToInvert |= plainValve.Mask;
cmpnt.StartChangeHandler(); /// Start handling parameter change events
}
- /// Create an array with tank capacities
- double[] tankCapacities = new double[tanks.Count];
- for (int i = 0; i < tankCapacities.Length; i++) tankCapacities[i] = tanks[i].Capacity;
-
/// Pre-initialize the control board (= buffer the arguments ctrlBrdComponent, tankCapacities)
if (ControlBoard == null)
{
@@ -362,29 +347,32 @@ namespace TBF.Rig
}
}
- if (cmpnt is IScaleOrTank)
- {
- IScaleOrTank tank = cmpnt as IScaleOrTank;
+ if (cmpnt is IScaleOrTank)
+ {
+ IScaleOrTank tank = cmpnt as IScaleOrTank;
- if ((tank.ScaleNr == 0) && (DrainValve1 == null))
- {
- DrainValve1 = tank.DrainValve;
- log.WarnFormat("InitializeBoardEtc() ... Scale1={0} Draining valve1={1}",
- tank.Name, (DrainValve1 != null) ? DrainValve1.Name : "---");
- }
- else if ((tank.ScaleNr == 1) && (DrainValve2 == null))
- {
- DrainValve2 = tank.DrainValve;
- log.WarnFormat("InitializeBoardEtc() ... Scale2={0} Draining valve2={1}",
- tank.Name, (DrainValve2 != null) ? DrainValve2.Name : "---");
- }
- else if ((tank.ScaleNr == 2) && (DrainValve3 == null))
- {
- DrainValve3 = tank.DrainValve;
- log.WarnFormat("InitializeBoardEtc() ... Scale3={0} Draining valve3={1}",
- tank.Name, (DrainValve3 != null) ? DrainValve3.Name : "---");
- }
- }
+ if (Tank1 == null)
+ {
+ Tank1 = tank;
+ DrainValve1 = tank.DrainValve;
+ log.WarnFormat("InitializeBoardEtc() ... Scale1={0} Draining valve1={1}",
+ tank.Name, (DrainValve1 != null) ? DrainValve1.Name : "---");
+ }
+ else if (Tank2 == null)
+ {
+ Tank2 = tank;
+ DrainValve2 = tank.DrainValve;
+ log.WarnFormat("InitializeBoardEtc() ... Scale2={0} Draining valve2={1}",
+ tank.Name, (DrainValve2 != null) ? DrainValve2.Name : "---");
+ }
+ else if (Tank3 == null)
+ {
+ Tank3 = tank;
+ DrainValve3 = tank.DrainValve;
+ log.WarnFormat("InitializeBoardEtc() ... Scale3={0} Draining valve3={1}",
+ tank.Name, (DrainValve3 != null) ? DrainValve3.Name : "---");
+ }
+ }
}
if (anyComponentIsInSimulMode)