Upgrade: Add remaining time display for tests, version 3.9.3134.110
Cause: 1. Missing functionality to display remaining time during tests in `StandingStartMassCollectionSeq.cs` and `StandingStartMassCollectionAdvanceSeq.cs`. 2. Assembly version and file version required an update to reflect changes. Solution: 1. Implemented remaining time display in `StandingStartMassCollectionSeq.cs` and `StandingStartMassCollectionAdvanceSeq.cs` using `Bridge.OnActivity` to show time in minutes and seconds or seconds only. 2. Updated assembly version and file version in `AssemblyInfo.cs` to `3.9.3134.110`.
This commit is contained in:
+6
@@ -821,6 +821,12 @@ namespace TBF.Rig.TestMethods.StandingStartMassCollectionAdvance
|
||||
|
||||
#endregion
|
||||
|
||||
/// Show remaining time
|
||||
if ((remainingTime = Math.Max(estimtdEndTime - StateMachine.Time, 0)) > 60)
|
||||
Bridge.OnActivity(this, string.Format("{0} ... {1} {2} {3} {4}", Strings.Test_in_progress, remainingTime / 60, "min", remainingTime % 60, Strings.sec));
|
||||
else
|
||||
Bridge.OnActivity(this, string.Format("{0} ... {1} s", Strings.Test_in_progress, remainingTime));
|
||||
|
||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Progress.Test));
|
||||
}
|
||||