Modbus modified, UniCB Init. modified, RunDeviceAfter() called in reversed order, ver. 3.1.1597
This commit is contained in:
@@ -24,9 +24,10 @@ namespace TBF.Rig.Modbus.Easytherm
|
||||
|
||||
public float requiredTemp { get { return easythermCfg.ProcParams.RequiredTemp; } }
|
||||
|
||||
public Easytherm()
|
||||
{
|
||||
}
|
||||
int ticketNumber; /// 1 .. number of devices registered for regular polling
|
||||
|
||||
|
||||
public Easytherm() { }
|
||||
|
||||
public Easytherm(Generic.IComponentCfg cfg, IList<Generic.IComponent> components)
|
||||
: base(cfg)
|
||||
@@ -47,6 +48,7 @@ namespace TBF.Rig.Modbus.Easytherm
|
||||
temperatureSetPointValid = false;
|
||||
temperatureSetPointRequested = false;
|
||||
actualTemperatureIsValid = false;
|
||||
ticketNumber = modbus.RegisterForPolling();
|
||||
}
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
@@ -81,26 +83,31 @@ namespace TBF.Rig.Modbus.Easytherm
|
||||
// StateMachine.ControlBoard.UpdateUI("ReservoirTemp", easythermCfg.ReservoirNr, actualTemperature);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
if (!temperatureSetPointValid && !temperatureSetPointRequested)
|
||||
{
|
||||
RequestTemperatureSetpoint();
|
||||
temperatureSetPointRequested = true;
|
||||
}
|
||||
else if (temperatureSetPointValid && requiredTemp != temperatureSetPoint)
|
||||
{
|
||||
SetTemperatureSetpoint(requiredTemp);
|
||||
log.InfoFormat("{0} - Set new temperature setpoint = {1}", Name, requiredTemp);
|
||||
}
|
||||
else if ((StateMachine.Time % 10) == (easythermCfg.ModbusAddress % 10)) /// This is to prevent overflow of the Modbus component queue for sending data
|
||||
}
|
||||
}
|
||||
|
||||
public void RunDeviceAfter()
|
||||
{
|
||||
if (easythermCfg.DebugLevel != Config.Entities.DebugMode.Simulate &&
|
||||
easythermCfg.DebugLevel != Config.Entities.DebugMode.FailureDuringOperation)
|
||||
{
|
||||
RequestActualTemperature();
|
||||
if (!temperatureSetPointValid && !temperatureSetPointRequested)
|
||||
{
|
||||
RequestTemperatureSetpoint();
|
||||
temperatureSetPointRequested = true;
|
||||
}
|
||||
else if (temperatureSetPointValid && requiredTemp != temperatureSetPoint)
|
||||
{
|
||||
SetTemperatureSetpoint(requiredTemp);
|
||||
log.InfoFormat("{0} - Set new temperature setpoint = {1}", Name, requiredTemp);
|
||||
}
|
||||
else if (modbus.IsMyTurn(ticketNumber))
|
||||
{
|
||||
RequestActualTemperature();
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
public void RunDeviceAfter() { }
|
||||
public void StopDevice() { }
|
||||
public void StopDevice2() { }
|
||||
|
||||
|
||||