Modbus modified, UniCB Init. modified, RunDeviceAfter() called in reversed order, ver. 3.1.1597
This commit is contained in:
@@ -74,9 +74,10 @@ namespace TBF.Rig.Modbus.Ambient.Comet
|
||||
/// <summary>Measurement time stamp when MsrmntState == MsrmntState.Valid</summary>
|
||||
int msrmntTimeStamp;
|
||||
|
||||
public Ambient()
|
||||
{
|
||||
}
|
||||
int ticketNumber; /// 1 .. number of devices registered for regular polling
|
||||
|
||||
|
||||
public Ambient() { }
|
||||
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
@@ -106,6 +107,7 @@ namespace TBF.Rig.Modbus.Ambient.Comet
|
||||
}
|
||||
|
||||
msrmntState = MsrmntState.Busy;
|
||||
ticketNumber = modbus.RegisterForPolling();
|
||||
|
||||
log.FatalFormat("Successfully initialized device {0}", ToString());
|
||||
}
|
||||
@@ -143,8 +145,13 @@ namespace TBF.Rig.Modbus.Ambient.Comet
|
||||
log.InfoFormat("Ambient: temperature = {0:F1} C, humidity = {1:F1} %, pressure = {2:F0} mbar", temperature, humidity, 1000 * pressure);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
if ((StateMachine.Time % 10) == (ambientCfg.ModbusAddress % 10)) /// Each 10 seconds
|
||||
public void RunDeviceAfter()
|
||||
{
|
||||
if (ambientCfg.DebugLevel != Config.Entities.DebugMode.Simulate &&
|
||||
ambientCfg.DebugLevel != Config.Entities.DebugMode.FailureDuringOperation &&
|
||||
modbus.IsMyTurn(ticketNumber))
|
||||
{
|
||||
/// Read four registers: 0x31, 0x32, 0x33, 0x34
|
||||
UInt16 regAddr = 0x0030; /// register addr. = 0x31 (Modbus!)
|
||||
@@ -163,7 +170,6 @@ namespace TBF.Rig.Modbus.Ambient.Comet
|
||||
}
|
||||
}
|
||||
|
||||
public void RunDeviceAfter() { }
|
||||
public void StopDevice() { }
|
||||
public void StopDevice2() { }
|
||||
|
||||
|
||||