MID pulses for each meter calculated correctly in all FlyingStart... methods for datastream meters.

This commit is contained in:
Milan Hanajik
2018-11-07 08:13:48 +01:00
parent 668304cb72
commit cebdd71065
7 changed files with 50 additions and 19 deletions
@@ -1,5 +1,5 @@
///
/// Copyright (c) 2013-2016 Sensus Metering Systems
/// Copyright (c) 2013-2018 Sensus Slovensko a.s.
///
using System;
using System.Collections.Generic;
@@ -134,6 +134,7 @@ namespace TBF.BenchControl.Elde.RegisterReader
public void Stop()
{
log.DebugFormat("{0}:Stop()", Name);
}
ReadPulses();
}
}
}
@@ -640,7 +640,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
meterRslt.RegReaderType = (int)regReader.RegisterReaderType;
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
if (dstrReader != null)
{
@@ -651,6 +650,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
meterRslt.VolumeEnd = dstrReader.VolumeLtrEnd; /// liter
meterRslt.VolumeMeter = Math.Abs(dstrReader.VolumeLtrEnd - dstrReader.VolumeLtrStart);
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
if (iPerl != null)
{
@@ -679,20 +679,23 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
/// Normal measurement with camera
meterRslt.TestTime = cameraRoi.TimestampEnd - cameraRoi.TimestampStart; /// second
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
}
else
{
/// None or one pulse from the water meter using camera
meterRslt.TestTime = tstRslt.TestTime;
meterRslt.VolumeRef = tstRslt.VolumeCTV;
meterRslt.PulsesMaster = tstRslt.PulsesMaster;
}
}
else
{
meterRslt.VolumeStart = 0;
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
meterRslt.VolumeStart = 0;
meterRslt.VolumeEnd = 0;
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
///
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
///
if (regReader.WMPulses >= 1)
{
/// Normal measurement
@@ -985,7 +985,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
meterRslt.RegReaderType = (int)regReader.RegisterReaderType;
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
if (dstrReader != null)
{
@@ -996,6 +995,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
meterRslt.VolumeEnd = dstrReader.VolumeLtrEnd; /// liter
meterRslt.VolumeMeter = Math.Abs(dstrReader.VolumeLtrEnd - dstrReader.VolumeLtrStart);
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
if (iPerl != null)
{
@@ -1021,11 +1021,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
meterRslt.VolumeMeter = cameraRoi.VolumeEnd - cameraRoi.VolumeStart; /// liter
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
}
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
}
else
{
meterRslt.TestTime = cBrd.ImpulseTime(i + 1);
meterRslt.VolumeStart = 0;
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
meterRslt.VolumeStart = 0;
meterRslt.VolumeEnd = 0;
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// liter
@@ -955,7 +955,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
meterRslt.RegReaderType = (int)regReader.RegisterReaderType;
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
if (dstrReader != null)
{
@@ -966,6 +965,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
meterRslt.VolumeEnd = dstrReader.VolumeLtrEnd; /// liter
meterRslt.VolumeMeter = Math.Abs(dstrReader.VolumeLtrEnd - dstrReader.VolumeLtrStart);
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
if (iPerl != null)
{
@@ -991,11 +991,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
meterRslt.VolumeMeter = cameraRoi.VolumeEnd - cameraRoi.VolumeStart; /// liter
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
}
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
}
else
{
meterRslt.TestTime = cBrd.ImpulseTime(i + 1); /// TODO: Malo by sa citat z dosky
meterRslt.VolumeStart = 0; /// liter
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
meterRslt.VolumeStart = 0; /// liter
meterRslt.VolumeEnd = 0; /// liter
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// liter
@@ -943,7 +943,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
meterRslt.RegReaderType = (int)regReader.RegisterReaderType;
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
if (dstrReader != null)
{
@@ -955,6 +954,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
meterRslt.VolumeEnd = dstrReader.VolumeLtrEnd; /// liter
meterRslt.VolumeMeter = Math.Abs(dstrReader.VolumeLtrEnd - dstrReader.VolumeLtrStart);
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
if (iPerl != null)
{
@@ -983,19 +983,22 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
/// Normal measurement with camera
meterRslt.TestTime = cameraRoi.TimestampEnd - cameraRoi.TimestampStart; /// second
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
}
else
{
/// None or one pulse from the water meter using camera
meterRslt.TestTime = tstRslt.TestTime;
meterRslt.VolumeRef = tstRslt.VolumeCTV;
meterRslt.PulsesMaster = tstRslt.PulsesMaster;
}
}
else
{
meterRslt.VolumeStart = 0; /// liter
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
meterRslt.VolumeStart = 0; /// liter
meterRslt.VolumeEnd = 0; /// liter
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
///
if (regReader.WMPulses >= 1)
{
@@ -596,7 +596,6 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
meterRslt.RegReaderType = (int)regReader.RegisterReaderType;
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
if (dstrReader != null)
{
@@ -608,6 +607,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
meterRslt.VolumeEnd = dstrReader.VolumeLtrEnd; /// liter
meterRslt.VolumeMeter = Math.Abs(dstrReader.VolumeLtrEnd - dstrReader.VolumeLtrStart);
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
if (iPerl != null)
{
@@ -636,17 +636,20 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
/// Normal measurement with camera
meterRslt.TestTime = cameraRoi.TimestampEnd - cameraRoi.TimestampStart; /// second
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
}
else
{
/// None or one pulse from the water meter using camera
meterRslt.TestTime = tstRslt.TestTime;
meterRslt.VolumeRef = tstRslt.VolumeCTV;
meterRslt.PulsesMaster = tstRslt.PulsesMaster;
}
}
else
{
meterRslt.VolumeStart = 0; /// liter
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
meterRslt.VolumeStart = 0; /// liter
meterRslt.VolumeEnd = 0; /// liter
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
///