Heat meters support for measurement with pulses, change in ResultsDB.MeterTestRslt, ver. 2.10.352

This commit is contained in:
Milan Hanajik
2016-10-06 10:11:13 +02:00
parent f51360c23d
commit c497c02ef9
25 changed files with 188 additions and 129 deletions
@@ -396,32 +396,47 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
{
if (test.Part != 0 && test.Part != Utils.PartNr(i + 1, BatchRslts.Batch.Compound)) continue;
Results.Entities.MeterTestRslt meterRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.Single);
GenericDevices.IRegisterReader regReader = sensPath.RegisterReaders[i];
Results.Entities.MeterTestRslt volumeRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterVolume);
Results.Entities.MeterTestRslt energyRslt = BatchRslts.GetMeterTestRslt(testName, i, Config.Entities.CompoundMeterId.HeatMeterEnergy);
if (meterRslt != null && regReader != null)
BenchControl.Elde.FixedStartRegisterReader.RegisterReader volumeRegReader =
(sensPath.RegisterReaders.Length > 2 * i) ? sensPath.RegisterReaders[2 * i] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader : null;
BenchControl.Elde.FixedStartRegisterReader.RegisterReader energyRegReader =
(sensPath.RegisterReaders.Length > 2 * i + 1) ? sensPath.RegisterReaders[2 * i + 1] as BenchControl.Elde.FixedStartRegisterReader.RegisterReader : null;
if (volumeRslt != null && volumeRegReader != null)
{
meterRslt.PulsesPerLiter = regReader.PulsesPerLtr;
meterRslt.PulsesMeter = Convert.ToDouble(regReader.WMPulses);
meterRslt.PulsesMaster = Convert.ToDouble(regReader.WMRefPulses);
volumeRslt.PulsesPerLiter = volumeRegReader.PulsesPerLtr; /// [l ^ -1]
volumeRslt.PulsesMeter = Convert.ToDouble(volumeRegReader.WMPulses);
volumeRslt.PulsesMaster = Convert.ToDouble(volumeRegReader.WMRefPulses);
volumeRslt.VolumeStart = 0;
volumeRslt.VolumeEnd = 0;
volumeRslt.VolumeMeter = volumeRslt.PulsesMeter * volumeRegReader.LtrsPerPulse; /// [l]
volumeRslt.VolumeRef = volumeRslt.PulsesMaster * tstRslt.ConstMaster; /// [l]
volumeRslt.TestTime = tstRslt.TestTime; /// [s]
meterRslt.TestTime = tstRslt.TestTime; /// TODO: Malo by sa citat z dosky
meterRslt.VolumeStart = 0; /// liter
meterRslt.VolumeEnd = 0; /// liter
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// liter
volumeRslt.Error = Formulas.ErrorFromVolumes(volumeRslt.VolumeMeter, volumeRslt.VolumeRef);
volumeRslt.Passed = (volumeRslt.Error >= test.ErrLimLo + test.Uncertainty)
&& (volumeRslt.Error <= test.ErrLimHi - test.Uncertainty);
volumeRslt.TestDone = true;
}
/// TODO: Rewrite the following 2 lines
meterRslt.EnergyStart = 0.0;
meterRslt.EnergyEnd = 1.0;
if (energyRslt != null && energyRegReader != null)
{
energyRslt.PulsesPerLiter = energyRegReader.PulsesPerLtr; /// [kWh ^ -1]
energyRslt.PulsesMeter = Convert.ToDouble(energyRegReader.WMPulses);
energyRslt.PulsesMaster = Convert.ToDouble(energyRegReader.WMRefPulses);
energyRslt.VolumeStart = 0;
energyRslt.VolumeEnd = 0;
energyRslt.VolumeMeter = energyRslt.PulsesMeter * Config.Units.ConvertFrom(Config.Unit.kWh, energyRegReader.LtrsPerPulse); /// [J]
energyRslt.VolumeRef = tstRslt.RefEnergy; /// [J]
energyRslt.TestTime = tstRslt.TestTime; /// [s]
meterRslt.Energy = meterRslt.EnergyEnd - meterRslt.EnergyStart;
meterRslt.RefEnergy = tstRslt.RefEnergy;
meterRslt.Error = Formulas.ErrorFromVolumes(meterRslt.Energy, meterRslt.RefEnergy);
meterRslt.Passed = (meterRslt.Error >= test.ErrLimLo + test.Uncertainty)
&& (meterRslt.Error <= test.ErrLimHi - test.Uncertainty);
meterRslt.TestDone = true;
energyRslt.Error = Formulas.ErrorFromVolumes(energyRslt.VolumeMeter, energyRslt.VolumeRef);
energyRslt.Passed = (energyRslt.Error >= test.ErrLimLo + test.Uncertainty)
&& (energyRslt.Error <= test.ErrLimHi - test.Uncertainty);
energyRslt.TestDone = true;
}
}
}