MunichPrintDocument : (1) Water pressure in bar, (2) Aux meter data bug fixed, ver. 2.12.388
This commit is contained in:
@@ -32,5 +32,5 @@ using System.Runtime.InteropServices;
|
|||||||
// You can specify all the values or you can default the Build and Revision Numbers
|
// You can specify all the values or you can default the Build and Revision Numbers
|
||||||
// by using the '*' as shown below:
|
// by using the '*' as shown below:
|
||||||
// [assembly: AssemblyVersion("1.0.*")]
|
// [assembly: AssemblyVersion("1.0.*")]
|
||||||
[assembly: AssemblyVersion("2.12.385.0")]
|
[assembly: AssemblyVersion("2.12.387.0")]
|
||||||
[assembly: AssemblyFileVersion("2.12.385.0")]
|
[assembly: AssemblyFileVersion("2.12.387.0")]
|
||||||
|
|||||||
@@ -283,7 +283,7 @@ namespace Results.Output.Printers.Munich
|
|||||||
if (compound)
|
if (compound)
|
||||||
{
|
{
|
||||||
Results.Entities.MeterTestRslt mainMtr = wm.GetMeterTestRslt(mtr.Name(), CompoundMeterId.CompoundMain);
|
Results.Entities.MeterTestRslt mainMtr = wm.GetMeterTestRslt(mtr.Name(), CompoundMeterId.CompoundMain);
|
||||||
Results.Entities.MeterTestRslt auxMtr = wm.GetMeterTestRslt(mtr.Name(), CompoundMeterId.CompoundMain);
|
Results.Entities.MeterTestRslt auxMtr = wm.GetMeterTestRslt(mtr.Name(), CompoundMeterId.CompoundAux);
|
||||||
|
|
||||||
PrintAt(e, FromTest(rowCnt, 2), mainMtr.VolumeMeter.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 2), mainMtr.VolumeMeter.ToString("F2"));
|
||||||
PrintAt(e, FromTest(rowCnt, 3), auxMtr.VolumeMeter.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 3), auxMtr.VolumeMeter.ToString("F2"));
|
||||||
@@ -301,8 +301,8 @@ namespace Results.Output.Printers.Munich
|
|||||||
PrintAt(e, FromTest(rowCnt, 7), mtr.TestRslt.TempDownMean.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 7), mtr.TestRslt.TempDownMean.ToString("F2"));
|
||||||
PrintAt(e, FromTest(rowCnt, 8), mtr.TestRslt.DensityDiv.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 8), mtr.TestRslt.DensityDiv.ToString("F2"));
|
||||||
PrintAt(e, FromTest(rowCnt, 9), mtr.TestTime.ToString("F1"));
|
PrintAt(e, FromTest(rowCnt, 9), mtr.TestTime.ToString("F1"));
|
||||||
PrintAt(e, FromTest(rowCnt, 10), mtr.TestRslt.PressUpMean.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 10), Config.Units.ConvertTo(Config.Unit.bar, mtr.TestRslt.PressUpMean).ToString("F3"));
|
||||||
PrintAt(e, FromTest(rowCnt, 11), mtr.TestRslt.PressDownMean.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 11), Config.Units.ConvertTo(Config.Unit.bar, mtr.TestRslt.PressDownMean).ToString("F3"));
|
||||||
|
|
||||||
rowCnt++;
|
rowCnt++;
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -32,5 +32,5 @@ using System.Runtime.InteropServices;
|
|||||||
// You can specify all the values or you can default the Build and Revision Numbers
|
// You can specify all the values or you can default the Build and Revision Numbers
|
||||||
// by using the '*' as shown below:
|
// by using the '*' as shown below:
|
||||||
// [assembly: AssemblyVersion("1.0.*")]
|
// [assembly: AssemblyVersion("1.0.*")]
|
||||||
[assembly: AssemblyVersion("2.12.385.0")]
|
[assembly: AssemblyVersion("2.12.388.0")]
|
||||||
[assembly: AssemblyFileVersion("2.12.385.0")]
|
[assembly: AssemblyFileVersion("2.12.388.0")]
|
||||||
|
|||||||
@@ -284,7 +284,7 @@ namespace TBF.BenchControl.ResultsPrinters.Munich
|
|||||||
if (compound)
|
if (compound)
|
||||||
{
|
{
|
||||||
Results.Entities.MeterTestRslt mainMtr = wm.GetMeterTestRslt(mtr.Name(), CompoundMeterId.CompoundMain);
|
Results.Entities.MeterTestRslt mainMtr = wm.GetMeterTestRslt(mtr.Name(), CompoundMeterId.CompoundMain);
|
||||||
Results.Entities.MeterTestRslt auxMtr = wm.GetMeterTestRslt(mtr.Name(), CompoundMeterId.CompoundMain);
|
Results.Entities.MeterTestRslt auxMtr = wm.GetMeterTestRslt(mtr.Name(), CompoundMeterId.CompoundAux);
|
||||||
|
|
||||||
PrintAt(e, FromTest(rowCnt, 2), mainMtr.VolumeMeter.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 2), mainMtr.VolumeMeter.ToString("F2"));
|
||||||
PrintAt(e, FromTest(rowCnt, 3), auxMtr.VolumeMeter.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 3), auxMtr.VolumeMeter.ToString("F2"));
|
||||||
@@ -302,8 +302,8 @@ namespace TBF.BenchControl.ResultsPrinters.Munich
|
|||||||
PrintAt(e, FromTest(rowCnt, 7), mtr.TestRslt.TempDownMean.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 7), mtr.TestRslt.TempDownMean.ToString("F2"));
|
||||||
PrintAt(e, FromTest(rowCnt, 8), mtr.TestRslt.DensityDiv.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 8), mtr.TestRslt.DensityDiv.ToString("F2"));
|
||||||
PrintAt(e, FromTest(rowCnt, 9), mtr.TestTime.ToString("F1"));
|
PrintAt(e, FromTest(rowCnt, 9), mtr.TestTime.ToString("F1"));
|
||||||
PrintAt(e, FromTest(rowCnt, 10), mtr.TestRslt.PressUpMean.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 10), Config.Units.ConvertTo(Config.Unit.bar, mtr.TestRslt.PressUpMean).ToString("F3"));
|
||||||
PrintAt(e, FromTest(rowCnt, 11), mtr.TestRslt.PressDownMean.ToString("F2"));
|
PrintAt(e, FromTest(rowCnt, 11), Config.Units.ConvertTo(Config.Unit.bar, mtr.TestRslt.PressDownMean).ToString("F3"));
|
||||||
|
|
||||||
rowCnt++;
|
rowCnt++;
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -29,5 +29,5 @@ using System.Runtime.InteropServices;
|
|||||||
// Build Number
|
// Build Number
|
||||||
// Revision
|
// Revision
|
||||||
//
|
//
|
||||||
[assembly: AssemblyVersion("2.12.387.1")]
|
[assembly: AssemblyVersion("2.12.388.1")]
|
||||||
[assembly: AssemblyFileVersion("2.12.387.1")]
|
[assembly: AssemblyFileVersion("2.12.388.1")]
|
||||||
|
|||||||
@@ -745,7 +745,7 @@
|
|||||||
<value>Auswahl Volumen und Fehlergrenzen</value>
|
<value>Auswahl Volumen und Fehlergrenzen</value>
|
||||||
</data>
|
</data>
|
||||||
<data name="SupressWMTrills" xml:space="preserve">
|
<data name="SupressWMTrills" xml:space="preserve">
|
||||||
<value>Supress trills</value>
|
<value>Filterschütteln</value>
|
||||||
</data>
|
</data>
|
||||||
<data name="Purge_bench_qm" xml:space="preserve">
|
<data name="Purge_bench_qm" xml:space="preserve">
|
||||||
<value>Prüfstand befüllen?</value>
|
<value>Prüfstand befüllen?</value>
|
||||||
|
|||||||
Reference in New Issue