(1) ProcessTabPageEx: TRefHi, TRefLo (2) Ambient vals. written directly to ProcessData (3) Sequences changed:'readTempPressOps', ver. 2.18.1171
This commit is contained in:
@@ -107,6 +107,7 @@ namespace TBF.BenchControl.Ambient.Comet
|
|||||||
value = (int)byteArr[9] * 256 + (int)byteArr[10];
|
value = (int)byteArr[9] * 256 + (int)byteArr[10];
|
||||||
pressure = (float)value / 10000.0f;
|
pressure = (float)value / 10000.0f;
|
||||||
|
|
||||||
|
UpdateProcessData(temperature, pressure, humidity);
|
||||||
msrmntTimeStamp = StateMachine.Time;
|
msrmntTimeStamp = StateMachine.Time;
|
||||||
msrmntState = MsrmntState.Valid;
|
msrmntState = MsrmntState.Valid;
|
||||||
log.InfoFormat("Ambient: temperature = {0:F1} C, humidity = {1:F1} %, pressure = {2:F0} mbar", temperature, humidity, 1000 * pressure);
|
log.InfoFormat("Ambient: temperature = {0:F1} C, humidity = {1:F1} %, pressure = {2:F0} mbar", temperature, humidity, 1000 * pressure);
|
||||||
@@ -185,6 +186,14 @@ namespace TBF.BenchControl.Ambient.Comet
|
|||||||
|
|
||||||
public void StopDevice2() { }
|
public void StopDevice2() { }
|
||||||
|
|
||||||
|
void UpdateProcessData(float temperature, float pressure, float humidity)
|
||||||
|
{
|
||||||
|
TBF.BenchControl.Sequences.ProcessData.AmbTemp.Val = temperature;
|
||||||
|
TBF.BenchControl.Sequences.ProcessData.AmbPress.Val = pressure;
|
||||||
|
TBF.BenchControl.Sequences.ProcessData.AmbHumi.Val = humidity;
|
||||||
|
}
|
||||||
|
|
||||||
|
|
||||||
///
|
///
|
||||||
/// Boxes for the operation result
|
/// Boxes for the operation result
|
||||||
///
|
///
|
||||||
|
|||||||
@@ -133,9 +133,10 @@ namespace TBF.BenchControl.Ambient.Greco
|
|||||||
temperature = t;
|
temperature = t;
|
||||||
humidity = h;
|
humidity = h;
|
||||||
pressure = p / 1000.0F;
|
pressure = p / 1000.0F;
|
||||||
msrmntTimeStamp = StateMachine.Time;
|
|
||||||
msrmntState = MsrmntState.Valid;
|
|
||||||
|
|
||||||
|
UpdateProcessData(temperature, pressure, humidity);
|
||||||
|
msrmntTimeStamp = StateMachine.Time;
|
||||||
|
msrmntState = MsrmntState.Valid;
|
||||||
log.InfoFormat("Ambient: temperature = {0:F1} C, humidity = {1:F1} %, pressure = {2:F0} mbar", temperature, humidity, 1000 * pressure);
|
log.InfoFormat("Ambient: temperature = {0:F1} C, humidity = {1:F1} %, pressure = {2:F0} mbar", temperature, humidity, 1000 * pressure);
|
||||||
}
|
}
|
||||||
else
|
else
|
||||||
@@ -170,6 +171,13 @@ namespace TBF.BenchControl.Ambient.Greco
|
|||||||
|
|
||||||
public void StopDevice2() { }
|
public void StopDevice2() { }
|
||||||
|
|
||||||
|
void UpdateProcessData(float temperature, float pressure, float humidity)
|
||||||
|
{
|
||||||
|
TBF.BenchControl.Sequences.ProcessData.AmbTemp.Val = temperature;
|
||||||
|
TBF.BenchControl.Sequences.ProcessData.AmbPress.Val = pressure;
|
||||||
|
TBF.BenchControl.Sequences.ProcessData.AmbHumi.Val = humidity;
|
||||||
|
}
|
||||||
|
|
||||||
///
|
///
|
||||||
/// Boxes for the operation result
|
/// Boxes for the operation result
|
||||||
///
|
///
|
||||||
|
|||||||
@@ -887,9 +887,6 @@ namespace TBF.BenchControl.Sequences
|
|||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
||||||
.AddOperation((realTest && (outPath.Scale is IScale)) ? (outPath.Scale as IScale).ReadMassOp(ref Mass) : null)
|
.AddOperation((realTest && (outPath.Scale is IScale)) ? (outPath.Scale as IScale).ReadMassOp(ref Mass) : null)
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
||||||
: null)
|
|
||||||
//.AddOperation(realTest ? (ticTac ? queryEnd1 : queryEnd2) : null)
|
//.AddOperation(realTest ? (ticTac ? queryEnd1 : queryEnd2) : null)
|
||||||
.AddOperation(realTest ? queryEnd1 : null)
|
.AddOperation(realTest ? queryEnd1 : null)
|
||||||
.AddOperation(realTest ? processDataLoggingOp : null)
|
.AddOperation(realTest ? processDataLoggingOp : null)
|
||||||
|
|||||||
@@ -1,5 +1,5 @@
|
|||||||
///
|
///
|
||||||
/// Copyright (c) 2013-2018 Sensus Slovensko a.s.
|
/// Copyright (c) 2013-2019 Sensus Slovensko a.s.
|
||||||
///
|
///
|
||||||
using System;
|
using System;
|
||||||
using System.Collections.Generic;
|
using System.Collections.Generic;
|
||||||
@@ -57,19 +57,8 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
{
|
{
|
||||||
float simulatedError = 4.5f; /// %
|
float simulatedError = 4.5f; /// %
|
||||||
|
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
IList<Event> e; /// Events from currently running operations
|
||||||
|
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
Event retVal = Event.Done;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
|
||||||
|
|
||||||
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
|
||||||
|
|
||||||
/// Notes:
|
|
||||||
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
|
||||||
/// float timeSec = 3600.0f * timeHr;
|
|
||||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
|
||||||
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
|
||||||
|
|
||||||
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
||||||
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
||||||
@@ -88,16 +77,45 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
if (rangeIx == -1)
|
if (rangeIx == -1)
|
||||||
{
|
{
|
||||||
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
||||||
retVal = Event.UiCmdStop;
|
return new List<Event> { Event.ConfigurationError };
|
||||||
goto stopTestWOStoppingDivGateEtc;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
||||||
|
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -108,13 +126,13 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create("Adjustment : Starting the pump")
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -129,11 +147,11 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -147,11 +165,11 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -163,11 +181,11 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -183,12 +201,12 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create("Adjustment : Setting the flow")
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -217,17 +235,15 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -296,12 +312,12 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
//tstRslt = MakeSimulated(test, 1, simulatedError);
|
//tstRslt = MakeSimulated(test, 1, simulatedError);
|
||||||
simulatedError *= 0.6f;
|
simulatedError *= 0.6f;
|
||||||
|
|
||||||
State.Create("Adjustment : Simulating the test")
|
State.Create(string.Format("{0}({1}) : Simulating the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(5))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(5))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -310,14 +326,13 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
}
|
}
|
||||||
else
|
else
|
||||||
{
|
{
|
||||||
State.Create("Adjustment : Starting the test")
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro,
|
.AddOperations(measureOperations)
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -477,12 +492,11 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
if (isLastRepetition || retVal == Event.UiCmdStop || retVal == Event.OpArgumentError
|
if (isLastRepetition || retVal == Event.UiCmdStop || retVal == Event.OpArgumentError
|
||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create("Adjustment : Stopping diverter, gate, etc.")
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -491,10 +505,7 @@ namespace TBF.BenchControl.TestMethods.Adjustment
|
|||||||
|
|
||||||
stopTestWOStoppingDivGateEtc:
|
stopTestWOStoppingDivGateEtc:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -40,7 +40,7 @@ namespace TBF.BenchControl.TestMethods.ChangeFlowDirection
|
|||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, 0));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, 0));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -106,18 +106,10 @@ namespace TBF.BenchControl.TestMethods.ChangeFlowDirection
|
|||||||
break;
|
break;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
return new List<Event> { Event.Done };
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(Event.Done);
|
|
||||||
return retList;
|
|
||||||
|
|
||||||
stopTest:
|
stopTest:
|
||||||
|
return new List<Event> { Event.UiCmdStop };
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
}
|
||||||
IList<Event> retList2 = new List<Event>(1);
|
|
||||||
retList2.Add(Event.UiCmdStop);
|
|
||||||
return retList2;
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -1,5 +1,5 @@
|
|||||||
///
|
///
|
||||||
/// Copyright (c) 2013-2018 Sensus Slovensko a.s.
|
/// Copyright (c) 2013-2019 Sensus Slovensko a.s.
|
||||||
///
|
///
|
||||||
using System;
|
using System;
|
||||||
using System.Collections.Generic;
|
using System.Collections.Generic;
|
||||||
@@ -50,6 +50,18 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
|
|
||||||
@@ -58,11 +70,10 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Stop diverter gate etc", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stop diverter gate etc", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
}
|
}
|
||||||
@@ -105,8 +116,20 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
/// Start the test, initialize test results
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, (int)totalPulses));
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -118,11 +141,11 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
{
|
{
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Mesuring mass of water in the tank", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Mesuring mass of water in the tank", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) goto error;
|
if (e.Contains(Event.Error)) goto error;
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
@@ -137,7 +160,7 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
}
|
}
|
||||||
|
|
||||||
/// Empty the water tank
|
/// Empty the water tank
|
||||||
switch (DrainTheTank(scale))
|
switch (DrainTheTank(scale, readTempPressOps))
|
||||||
{
|
{
|
||||||
case Event.Error: goto error;
|
case Event.Error: goto error;
|
||||||
case Event.UiCmdStop: goto stopTest;
|
case Event.UiCmdStop: goto stopTest;
|
||||||
@@ -195,13 +218,13 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
Bridge.OnActivity(this, Strings.Switching_flow_detection);
|
Bridge.OnActivity(this, Strings.Switching_flow_detection);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Start the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Start the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation((inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOnOp(test.PumpPower) : null)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
.AddOperation((inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOnOp(test.PumpPower) : null)
|
||||||
.EnterState();
|
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
||||||
|
|
||||||
@@ -211,12 +234,12 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
|
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Set the initial flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Set the initial flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowAndMeasureOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec, (float)test.TolerRed))
|
.AddOperations(measureOperations)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowAndMeasureOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec, (float)test.TolerRed))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
||||||
|
|
||||||
@@ -269,11 +292,11 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Change the RV position", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Change the RV position", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(outPath.RegulValve.ChangeRegulValvePositionOp(rvPulse))
|
.AddOperation(outPath.RegulValve.ChangeRegulValvePositionOp(rvPulse))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
||||||
|
|
||||||
@@ -416,12 +439,12 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
{
|
{
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Switching flow detected, going back", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Switching flow detected, going back", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(measureOperations)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -439,12 +462,12 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Going to the test flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Going to the test flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, qfrom_detected, qto_detected, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, qfrom_detected, qto_detected, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
//.AddOp(pOut.RegulValve.SetPositionOp(35.0f, 38.0f, uint.MaxValue))
|
//.AddOp(pOut.RegulValve.SetPositionOp(35.0f, 38.0f, uint.MaxValue))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -462,13 +485,13 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(Strings.Measure_the_mass)
|
State.Create(Strings.Measure_the_mass)
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) goto error;
|
if (e.Contains(Event.Error)) goto error;
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
@@ -486,13 +509,12 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(Strings.Start_the_test)
|
State.Create(Strings.Start_the_test)
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
.AddOperations(measureOperations)
|
||||||
qfrom_detected, qto_detected, totalPulses, filters))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.Synchro), qfrom_detected, qto_detected, totalPulses, filters))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) goto error;
|
if (e.Contains(Event.Error)) goto error;
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
@@ -557,13 +579,13 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(Strings.Measure_the_mass)
|
State.Create(string.Format("{0}({1}) : Measuring the mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) goto error;
|
if (e.Contains(Event.Error)) goto error;
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
@@ -585,12 +607,12 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
Bridge.OnActivity(this, Strings.Test_completed);
|
Bridge.OnActivity(this, Strings.Test_completed);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(Strings.Stop_the_pump)
|
State.Create(Strings.Stop_the_pump)
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
||||||
.EnterState();
|
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
}
|
}
|
||||||
@@ -598,12 +620,12 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
|
|
||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create("stop_diverter_gate_etc")
|
State.Create(string.Format("{0}({1}) : Stop_diverter_gate_etc", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
}
|
}
|
||||||
@@ -754,18 +776,14 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
||||||
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) goto error;
|
if (e.Contains(Event.Error)) goto error;
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.ValvesSet) || ((inPath.Pump is GenericDevices.IPumpFM) && !e.Contains(Event.TurnPumpOnOffDone)));
|
while (!e.Contains(Event.ValvesSet) || ((inPath.Pump is GenericDevices.IPumpFM) && !e.Contains(Event.TurnPumpOnOffDone)));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create the return value - a list with one event Event.Done - and return
|
return new List<Event> { Event.Done };
|
||||||
IList<Event> retval1 = new List<Event>(1);
|
|
||||||
retval1.Add(Event.Done);
|
|
||||||
return retval1;
|
|
||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
stopTest:
|
stopTest:
|
||||||
@@ -782,9 +800,7 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
}
|
}
|
||||||
while (!e.Contains(Event.ValvesSet));
|
while (!e.Contains(Event.ValvesSet));
|
||||||
|
|
||||||
IList<Event> retval2 = new List<Event>(1);
|
return new List<Event> { Event.UiCmdStop };
|
||||||
retval2.Add(Event.UiCmdStop);
|
|
||||||
return retval2;
|
|
||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
error:
|
error:
|
||||||
@@ -800,9 +816,7 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
}
|
}
|
||||||
while (!e.Contains(Event.ValvesSet));
|
while (!e.Contains(Event.ValvesSet));
|
||||||
|
|
||||||
IList<Event> retval3 = new List<Event>(1);
|
return new List<Event> { Event.Error };
|
||||||
retval3.Add(Event.Error);
|
|
||||||
return retval3;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@@ -836,10 +850,7 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
|||||||
.EnterState();
|
.EnterState();
|
||||||
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done };
|
||||||
IList<Event> retListSim = new List<Event>(1);
|
|
||||||
retListSim.Add(TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done);
|
|
||||||
return retListSim;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -30,13 +30,43 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
string enduranceCycleStr,
|
string enduranceCycleStr,
|
||||||
Config.Entities.DebugMode debugLevel)
|
Config.Entities.DebugMode debugLevel)
|
||||||
{
|
{
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
||||||
Event retVal = Event.Done;
|
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
{
|
||||||
|
Elde.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Elde.FlowMeter.FlowMeter;
|
||||||
|
rangeIx = -1; /// Indicates invalid range
|
||||||
|
for (int r = 0; r <= 5; r++)
|
||||||
|
{
|
||||||
|
if (eldeFM.RangeEnabled(r) && eldeFM.GetTempLo(r) <= test.TempLimLo
|
||||||
|
&& eldeFM.GetTempHi(r) >= test.TempLimHi)
|
||||||
|
{
|
||||||
|
rangeIx = r;
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
|
if (rangeIx == -1)
|
||||||
|
{
|
||||||
|
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
||||||
|
return new List<Event> { Event.ConfigurationError };
|
||||||
|
}
|
||||||
|
}
|
||||||
|
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
|
||||||
string enduranceLogDir = string.Format("C:\\TBF\\Results\\{0:yyyy}\\{0:MM}\\{0:dd}\\", BatchRslts.Batch.StartTime);
|
string enduranceLogDir = string.Format("C:\\TBF\\Results\\{0:yyyy}\\{0:MM}\\{0:dd}\\", BatchRslts.Batch.StartTime);
|
||||||
string enduranceLogName = string.Format("{0}{1:HHmm}.txt", enduranceLogDir, BatchRslts.Batch.StartTime);
|
string enduranceLogName = string.Format("{0}{1:HHmm}.txt", enduranceLogDir, BatchRslts.Batch.StartTime);
|
||||||
@@ -54,41 +84,28 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
enduranceDataLoggingOp = null;
|
enduranceDataLoggingOp = null;
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
|
||||||
/// Notes:
|
|
||||||
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
|
||||||
/// float timeSec = 3600.0f * timeHr;
|
|
||||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
|
||||||
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
||||||
|
|
||||||
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
Event retVal = Event.Done;
|
||||||
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
IList<Event> e; /// Events from currently running operations
|
||||||
{
|
|
||||||
Elde.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Elde.FlowMeter.FlowMeter;
|
|
||||||
rangeIx = -1; /// Indicates invalid range
|
|
||||||
for (int r = 0; r <= 5; r++)
|
|
||||||
{
|
|
||||||
if (eldeFM.RangeEnabled(r) && eldeFM.GetTempLo(r) <= test.TempLimLo
|
|
||||||
&& eldeFM.GetTempHi(r) >= test.TempLimHi)
|
|
||||||
{
|
|
||||||
rangeIx = r;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
if (rangeIx == -1)
|
|
||||||
{
|
|
||||||
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
|
||||||
retVal = Event.UiCmdStop;
|
|
||||||
goto stopTestWOStoppingDivGateEtc;
|
|
||||||
}
|
|
||||||
}
|
|
||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -99,12 +116,12 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -120,11 +137,11 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
int flowSetTime0 = StateMachine.Time;
|
int flowSetTime0 = StateMachine.Time;
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -155,17 +172,15 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -231,27 +246,14 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(enduranceDataLoggingOp)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(enduranceDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -280,28 +282,15 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
|
|
||||||
/// Measurement loop - begin
|
/// Measurement loop - begin
|
||||||
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(readRegistersOp)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(readRegistersOp)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(queryEnd1)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(enduranceDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
||||||
: null)
|
|
||||||
.AddOperation(queryEnd1)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(enduranceDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -495,11 +484,11 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
||||||
}
|
}
|
||||||
@@ -535,20 +524,13 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
cBrd.CyclePar = cyclePar;
|
cBrd.CyclePar = cyclePar;
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Uploading cycle parameters", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Uploading cycle parameters", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.ExecuteCommandOp(Elde.Command.EnduranceCycleParamsUpload, Elde.Command.None, 0))
|
||||||
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(enduranceDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation((StateMachine.Ambient != null) ? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(enduranceDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.ExecuteCommandOp(Elde.Command.EnduranceCycleParamsUpload, Elde.Command.None, 0))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -564,21 +546,14 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
bool stopInProgress = false;
|
bool stopInProgress = false;
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Executing the cycle", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Executing the cycle", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp((int)test.TstTime, Event.TimerExpired))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(new Operations.TimerOp((int)test.TstTime, Event.TimerExpired))
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.ExecuteCommandOp(Elde.Command.EnduranceCycleStart, Elde.Command.EnduranceCycleStop, 0))
|
||||||
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(enduranceDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation((StateMachine.Ambient != null) ? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(enduranceDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.ExecuteCommandOp(Elde.Command.EnduranceCycleStart, Elde.Command.EnduranceCycleStop, 0))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e))
|
if (TestAndLogUiCmdStop(test, e))
|
||||||
@@ -614,20 +589,13 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
Bridge.OnActivity(this, Strings.Last_cycle_wait_please);
|
Bridge.OnActivity(this, Strings.Last_cycle_wait_please);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Delay to make sure the last endu.cycle completed", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Delay to make sure the last endu.cycle completed", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp((int)(duration / 1000) + 1, Event.TimerExpired))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(new Operations.TimerOp((int)(duration / 1000) + 1, Event.TimerExpired))
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(enduranceDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation((StateMachine.Ambient != null) ? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(enduranceDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e))
|
if (TestAndLogUiCmdStop(test, e))
|
||||||
@@ -665,11 +633,10 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
||||||
}
|
}
|
||||||
@@ -678,10 +645,7 @@ namespace TBF.BenchControl.TestMethods.Endurance
|
|||||||
|
|
||||||
stopTestWOStoppingDivGateEtc:
|
stopTestWOStoppingDivGateEtc:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -67,7 +67,20 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
@@ -83,8 +96,20 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
|
|
||||||
///
|
///
|
||||||
@@ -107,11 +132,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Measuring mass of water in the tank", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring mass of water in the tank", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
||||||
|
|
||||||
@@ -139,12 +164,12 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Make sure the drain valve is closed", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Make sure the drain valve is closed", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
||||||
|
|
||||||
@@ -165,13 +190,13 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -186,12 +211,12 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -205,12 +230,12 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -222,12 +247,12 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -249,12 +274,12 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
}
|
}
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Pump on", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Pump on", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(inPath.Pump, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(inPath.Pump, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -264,12 +289,12 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
while (e.Contains(Event.ValvesBusy));
|
while (e.Contains(Event.ValvesBusy));
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Start valve open", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Start valve open", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -281,12 +306,12 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -318,15 +343,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
double Tc_last = 0;
|
double Tc_last = 0;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(heatMetersPromptOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -363,11 +384,9 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -387,15 +406,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
||||||
//-----------------------------------------------------------------
|
//-----------------------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Closing the start/stop valve before the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve before the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -413,15 +428,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
if (test.TimeFlow2Mass > 0)
|
if (test.TimeFlow2Mass > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 1st measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 1st measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -447,8 +458,9 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
{
|
{
|
||||||
string[] startImages = new string[sensPath.RegisterReaders.Length];
|
string[] startImages = new string[sensPath.RegisterReaders.Length];
|
||||||
|
|
||||||
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp);
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps);
|
||||||
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
||||||
{
|
{
|
||||||
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
||||||
@@ -477,15 +489,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
|
|
||||||
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
||||||
State.Create(string.Format("{0}({1}) : Entering begin-state", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Entering begin-state", test.Method, test.Name))
|
||||||
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp(sensPath.RegisterReaders))
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp(sensPath.RegisterReaders))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(checkUiOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -550,22 +558,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro, test.Qfrom, test.Qto, 2 * totalPulses, new int[] { (int)test.TolerRed, }))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, 2 * totalPulses, new int[] { (int)test.TolerRed, }))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -575,21 +572,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
StartTime = (double)StateMachine.Time;
|
StartTime = (double)StateMachine.Time;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Opening the start/stop valve at the beginning of the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the start/stop valve at the beginning of the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -686,21 +673,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
EndTime = (double)StateMachine.Time;
|
EndTime = (double)StateMachine.Time;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -710,25 +687,13 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 2nd measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 2nd measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -741,11 +706,11 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
|
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -770,7 +735,9 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
string[] endImages = new string[sensPath.RegisterReaders.Length];
|
string[] endImages = new string[sensPath.RegisterReaders.Length];
|
||||||
|
|
||||||
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp);
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps);
|
||||||
|
|
||||||
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
||||||
{
|
{
|
||||||
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
||||||
@@ -783,8 +750,7 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
state2.EnterState();
|
state2.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
@@ -801,20 +767,19 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
State state = State.Create(string.Format("{0}({1}) : Entering the end-state", test.Method, test.Name));
|
State state = State.Create(string.Format("{0}({1}) : Entering the end-state", test.Method, test.Name));
|
||||||
if (heatMetersTestParams != null && dataEntryCmpnt is GenericDevices.IHasHeatMtrStatesForm)
|
if (heatMetersTestParams != null && dataEntryCmpnt is GenericDevices.IHasHeatMtrStatesForm)
|
||||||
{
|
{
|
||||||
state.AddOperation((dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).
|
state.AddOperation((dataEntryCmpnt as GenericDevices.IHasHeatMtrStatesForm).ShowTestEndFormOp(sensPath.RegisterReaders,
|
||||||
ShowTestEndFormOp(sensPath.RegisterReaders,
|
volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty,
|
||||||
volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty,
|
refEnergy, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty));
|
||||||
refEnergy, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty));
|
|
||||||
}
|
}
|
||||||
else
|
else
|
||||||
{
|
{
|
||||||
state.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(sensPath.RegisterReaders,
|
state.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(sensPath.RegisterReaders,
|
||||||
volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty));
|
volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty));
|
||||||
}
|
}
|
||||||
state.AddOperation(checkUiOp);
|
state.AddOperation(checkUiOp)
|
||||||
state.EnterState();
|
.AddOperations(readTempPressOps)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -1132,10 +1097,7 @@ namespace TBF.BenchControl.TestMethods.FixedStart
|
|||||||
|
|
||||||
stopTestWOStoppingDivGateEtc:
|
stopTestWOStoppingDivGateEtc:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -64,7 +64,21 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
|
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
Event retVal = Event.Done;
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
@@ -77,12 +91,22 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
||||||
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
||||||
|
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
|
||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
/// Start the test, initialize test results
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -93,11 +117,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
/// Measure the weight in case there is no unconditional draining
|
/// Measure the weight in case there is no unconditional draining
|
||||||
///
|
///
|
||||||
State.Create("FixedStartAdvanced : Measuring mass of water in the tank")
|
State.Create("FixedStartAdvanced : Measuring mass of water in the tank")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -115,7 +139,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
///
|
///
|
||||||
/// Drain the water tank
|
/// Drain the water tank
|
||||||
///
|
///
|
||||||
switch (DrainTheTank(scale))
|
switch (DrainTheTank(scale, readTempPressOps))
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -133,11 +157,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
|
|
||||||
State.Create("FixedStartAdvanced : Waiting 5 sec")
|
State.Create("FixedStartAdvanced : Waiting 5 sec")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(5))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(5))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -148,11 +172,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
|
|
||||||
|
|
||||||
State.Create("FixedStartAdvanced : Starting the pump")
|
State.Create("FixedStartAdvanced : Starting the pump")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -169,11 +193,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
State.Create("FixedStartAdvanced : Starting the pump")
|
State.Create("FixedStartAdvanced : Starting the pump")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -184,11 +208,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create("FixedStartAdvanced : Setting the flow")
|
State.Create("FixedStartAdvanced : Setting the flow")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -212,11 +236,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create("FixedStartAdvanced : Closing the start/stop valve before the fixed start test")
|
State.Create("FixedStartAdvanced : Closing the start/stop valve before the fixed start test")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -278,11 +302,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
{
|
{
|
||||||
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
||||||
State.Create("FixedStartAdvanced : Enter begin-state")
|
State.Create("FixedStartAdvanced : Enter begin-state")
|
||||||
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp(sensPath.RegisterReaders))
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(checkUiOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp(sensPath.RegisterReaders))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -302,22 +326,14 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create("FixedStartAdvanced : Measuring the start mass")
|
State.Create("FixedStartAdvanced : Measuring the start mass")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -337,13 +353,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create("FixedStartAdvanced : Starting the test")
|
State.Create("FixedStartAdvanced : Starting the test")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
.AddOperations(measureOperations)
|
||||||
test.Qfrom, test.Qto, 2 * totalPulses, filters))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.Synchro), test.Qfrom, test.Qto, 2 * totalPulses, filters))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -352,11 +367,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
|
|
||||||
|
|
||||||
State.Create("FixedStartAdvanced : Opening the start/stop valve at the beginning of the fixed start test")
|
State.Create("FixedStartAdvanced : Opening the start/stop valve at the beginning of the fixed start test")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -414,11 +429,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
StopRecordingStatistics();
|
StopRecordingStatistics();
|
||||||
|
|
||||||
State.Create("FixedStartAdvanced : Closing the start/stop valve at the end of the fixed start test")
|
State.Create("FixedStartAdvanced : Closing the start/stop valve at the end of the fixed start test")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -426,21 +441,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
|
|
||||||
|
|
||||||
State.Create("FixedStartAdvanced : Waiting before 2nd mass measurement")
|
State.Create("FixedStartAdvanced : Waiting before 2nd mass measurement")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -452,21 +459,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create("FixedStartAdvanced : Measuring the end mass")
|
State.Create("FixedStartAdvanced : Measuring the end mass")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -483,11 +482,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
|
|
||||||
|
|
||||||
State.Create("FixedStartAdvanced : Stopping diverter, gate, etc.")
|
State.Create("FixedStartAdvanced : Stopping diverter, gate, etc.")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -510,14 +509,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
{
|
{
|
||||||
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
||||||
State.Create("FixedStartAdvanced : Enter end-state")
|
State.Create("FixedStartAdvanced : Enter end-state")
|
||||||
.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(sensPath.RegisterReaders,
|
.AddOperation(checkUiOp)
|
||||||
volumeCTV,
|
.AddOperations(readTempPressOps)
|
||||||
test.ErrLimLo + test.Uncertainty,
|
.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(sensPath.RegisterReaders, volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty))
|
||||||
test.ErrLimHi - test.Uncertainty))
|
.EnterState();
|
||||||
.AddOperation(checkUiOp)
|
do {
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -653,21 +649,17 @@ namespace TBF.BenchControl.TestMethods.FixedStartAdvanced
|
|||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create("FixedStartAdvanced : Stopping diverter, gate, etc.")
|
State.Create("FixedStartAdvanced : Stopping diverter, gate, etc.")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.PreviousStopped));
|
while (!e.Contains(Event.PreviousStopped));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal }; /// default 'retVal' value is Event.Done
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
+169
-243
@@ -94,7 +94,20 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
@@ -110,8 +123,20 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
|
|
||||||
///
|
///
|
||||||
@@ -127,19 +152,18 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
if (!test.DoDraining)
|
if (!test.DoDraining)
|
||||||
{
|
{
|
||||||
///
|
///
|
||||||
/// Measure the weight in case there is no unconditional draining
|
/// Measure the weight in case there is no unconditional draining
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Measuring mass of water in the tank", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring mass of water in the tank", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
||||||
|
|
||||||
@@ -156,7 +180,9 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
///
|
///
|
||||||
/// Drain the water tank
|
/// Drain the water tank
|
||||||
///
|
///
|
||||||
switch (DrainTheTank(scale, heatMetersPromptOp))
|
IList<IOperation> ops = new List<IOperation>(readTempPressOps);
|
||||||
|
ops.Add(heatMetersPromptOp);
|
||||||
|
switch (DrainTheTank(scale, ops))
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -167,12 +193,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Make sure the drain valve is closed", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Make sure the drain valve is closed", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
||||||
|
|
||||||
@@ -193,13 +219,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -214,12 +240,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -233,12 +259,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -250,12 +276,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -277,12 +303,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
}
|
}
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Pump on", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Pump on", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(inPath.Pump, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(inPath.Pump, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -292,12 +318,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
while (e.Contains(Event.ValvesBusy));
|
while (e.Contains(Event.ValvesBusy));
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Start valve open", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Start valve open", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -309,12 +335,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -346,15 +372,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
double Tc_last = 0;
|
double Tc_last = 0;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(heatMetersPromptOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -365,12 +387,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
{
|
{
|
||||||
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
|
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
|
||||||
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
|
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
|
||||||
if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi &&
|
if ((heatMetersTestParams.TempWarmLo <= Tw) && (Tw <= heatMetersTestParams.TempWarmHi) &&
|
||||||
heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi &&
|
(heatMetersTestParams.TempColdLo <= Tc) && (Tc <= heatMetersTestParams.TempColdHi) &&
|
||||||
Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm &&
|
(Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm) &&
|
||||||
Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold &&
|
(Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold) &&
|
||||||
Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm &&
|
(Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm) &&
|
||||||
Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold)
|
(Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -383,7 +405,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
}
|
}
|
||||||
while (true);
|
while (true);
|
||||||
}
|
}
|
||||||
else if (test.DoControlWaterTemp && benchPath.TempMtrUp != null && benchPath.TempMtrDown != null)
|
else if (test.DoControlWaterTemp && (benchPath.TempMtrUp != null) && (benchPath.TempMtrDown != null))
|
||||||
{
|
{
|
||||||
//---------------------------------------------------
|
//---------------------------------------------------
|
||||||
Bridge.OnActivity(this, Strings.Setting_temperature);
|
Bridge.OnActivity(this, Strings.Setting_temperature);
|
||||||
@@ -391,17 +413,15 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -415,15 +435,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
||||||
//-----------------------------------------------------------------
|
//-----------------------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Closing the start/stop valve before the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve before the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -441,15 +457,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
if (test.TimeFlow2Mass > 0)
|
if (test.TimeFlow2Mass > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -465,25 +477,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -509,10 +509,8 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
{
|
{
|
||||||
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps);
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
|
||||||
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
||||||
{
|
{
|
||||||
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
||||||
@@ -525,8 +523,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
state2.EnterState();
|
state2.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
@@ -614,22 +611,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.Synchro),
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
test.Qfrom, test.Qto, (2 * totalPulses), new int[] { (int)test.TolerRed, }))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, 2 * totalPulses, new int[] { (int)test.TolerRed, }))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -638,22 +625,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
|
|
||||||
StartTime = (double)StateMachine.Time;
|
StartTime = (double)StateMachine.Time;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Opening the start/stop valve at the beginning of the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -750,21 +727,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
EndTime = (double)StateMachine.Time;
|
EndTime = (double)StateMachine.Time;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -774,25 +741,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 2nd mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 2nd mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -807,25 +762,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -842,11 +785,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
|
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -875,12 +818,10 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
if (debugLevel != Config.Entities.DebugMode.Simulate)
|
if (debugLevel != Config.Entities.DebugMode.Simulate)
|
||||||
{
|
{
|
||||||
|
|
||||||
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps);
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
|
||||||
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
||||||
{
|
{
|
||||||
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
||||||
@@ -893,8 +834,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
state2.EnterState();
|
state2.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
@@ -1029,8 +969,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } /// TODO: this is an endless loop !!!
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; } /// TODO: this is an endless loop !!!
|
||||||
}
|
}
|
||||||
@@ -1039,10 +978,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
|
|
||||||
stopTestWOTransitionAfter:
|
stopTestWOTransitionAfter:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal }; /// default 'retVal' value is Event.Done
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@@ -1051,15 +987,10 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
/// Fixed start mass collection method with deferred evaluation of images
|
/// Fixed start mass collection method with deferred evaluation of images
|
||||||
/// </summary>
|
/// </summary>
|
||||||
/// <param name="test">Test entity</param>
|
/// <param name="test">Test entity</param>
|
||||||
/// <returns>
|
/// <returns>Always Event.Done</returns>
|
||||||
/// Event.Done . . . . . . . OK
|
|
||||||
/// Event.UiCmdStop . . . . Stopped by the user using the on-screen button STOP
|
|
||||||
/// Event.Error . . . . . . Unspecified error
|
|
||||||
/// </returns>
|
|
||||||
public IList<Event> Execute2ndPass(Config.Entities.Test test, int repetNr, IntermediateData data)
|
public IList<Event> Execute2ndPass(Config.Entities.Test test, int repetNr, IntermediateData data)
|
||||||
{
|
{
|
||||||
IList<Event> e = new List<Event>(1); /// Events from currently running operations
|
IList<Event> e; /// Events from currently running operations
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
|
||||||
///
|
///
|
||||||
/// Populate TestResult data entity with data
|
/// Populate TestResult data entity with data
|
||||||
@@ -1075,13 +1006,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
|
|
||||||
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
||||||
State.Create(string.Format("{0}({1}) : Entering water meter states", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Entering water meter states", test.Method, test.Name))
|
||||||
.AddOperation(de4Cam.ShowDeferredTestEvalFormOp(sensPath.RegisterReaders,
|
.AddOperation(de4Cam.ShowDeferredTestEvalFormOp(sensPath.RegisterReaders, tstRslt.VolumeCTV,
|
||||||
tstRslt.VolumeCTV,
|
test.ErrLimLo + test.Uncertainty,
|
||||||
test.ErrLimLo + test.Uncertainty,
|
test.ErrLimHi - test.Uncertainty))
|
||||||
test.ErrLimHi - test.Uncertainty))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
}
|
}
|
||||||
while (e.Contains(Event.ModelessFormIsOpen));
|
while (e.Contains(Event.ModelessFormIsOpen));
|
||||||
@@ -1203,14 +1132,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartDeferredEvaluation
|
|||||||
allResults.Info(TestResult2CsvLine(data.TestName, data.TestPart));
|
allResults.Info(TestResult2CsvLine(data.TestName, data.TestPart));
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
/// No operation for 1 period so that Stop() function of Data entry component is called
|
/// No operation for 1 period so that Stop() function of Data entry component is called
|
||||||
State.Create(string.Format("{0}({1}) : No Op.", test.Method, test.Name)).EnterState();
|
State.Create(string.Format("{0}({1}) : No Op.", test.Method, test.Name)).EnterState();
|
||||||
do { e = StateMachine.WaitRunDevsRunOps(); } while (false);
|
StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
|
return new List<Event> { Event.Done }; ;
|
||||||
e.Add(retVal);
|
|
||||||
return e;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
+163
-223
@@ -1,5 +1,5 @@
|
|||||||
///
|
///
|
||||||
/// Copyright (c) 2013-2017 Sensus Metering Systems
|
/// Copyright (c) 2013-2019 Sensus Slovensko a.s.
|
||||||
///
|
///
|
||||||
using System;
|
using System;
|
||||||
using System.Collections.Generic;
|
using System.Collections.Generic;
|
||||||
@@ -74,7 +74,20 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
@@ -90,8 +103,20 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
|
|
||||||
///
|
///
|
||||||
@@ -114,12 +139,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
/// Measure the weight in case there is no unconditional draining
|
/// Measure the weight in case there is no unconditional draining
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Measuring mass of water in the tank", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring mass of water in the tank", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
||||||
|
|
||||||
@@ -136,7 +161,9 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
///
|
///
|
||||||
/// Drain the water tank
|
/// Drain the water tank
|
||||||
///
|
///
|
||||||
switch (DrainTheTank(scale, heatMetersPromptOp))
|
IList<IOperation> ops = new List<IOperation>(readTempPressOps);
|
||||||
|
ops.Add(heatMetersPromptOp);
|
||||||
|
switch (DrainTheTank(scale, ops))
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -147,12 +174,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Make sure the drain valve is closed", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Make sure the drain valve is closed", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.JustStarted));
|
||||||
|
|
||||||
@@ -173,13 +200,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -194,12 +221,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -213,12 +240,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -230,12 +257,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -257,12 +284,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
}
|
}
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Pump on", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Pump on", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(inPath.Pump, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(inPath.Pump, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -272,12 +299,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
while (e.Contains(Event.ValvesBusy));
|
while (e.Contains(Event.ValvesBusy));
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Start valve open", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Start valve open", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -289,12 +316,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -326,15 +353,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
double Tc_last = 0;
|
double Tc_last = 0;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(heatMetersPromptOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -345,12 +368,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
{
|
{
|
||||||
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
|
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
|
||||||
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
|
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
|
||||||
if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi &&
|
if ((heatMetersTestParams.TempWarmLo <= Tw) && (Tw <= heatMetersTestParams.TempWarmHi) &&
|
||||||
heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi &&
|
(heatMetersTestParams.TempColdLo <= Tc) && (Tc <= heatMetersTestParams.TempColdHi) &&
|
||||||
Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm &&
|
(Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm) &&
|
||||||
Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold &&
|
(Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold) &&
|
||||||
Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm &&
|
(Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm) &&
|
||||||
Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold)
|
(Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -371,11 +394,9 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -395,15 +416,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
||||||
//-----------------------------------------------------------------
|
//-----------------------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Closing the start/stop valve before the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve before the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -421,15 +438,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
if (test.TimeFlow2Mass > 0)
|
if (test.TimeFlow2Mass > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -445,25 +458,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -493,7 +494,9 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
string[] startImages = new string[sensPath.RegisterReaders.Length];
|
string[] startImages = new string[sensPath.RegisterReaders.Length];
|
||||||
|
|
||||||
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp);
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps);
|
||||||
|
|
||||||
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
||||||
{
|
{
|
||||||
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
||||||
@@ -506,8 +509,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
state2.EnterState();
|
state2.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
@@ -522,15 +524,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
|
|
||||||
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
||||||
State.Create(string.Format("{0}({1}) : Entering begin-state", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Entering begin-state", test.Method, test.Name))
|
||||||
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp(sensPath.RegisterReaders))
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp(sensPath.RegisterReaders))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(checkUiOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -602,22 +600,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.FixedStart),
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
test.Qfrom, test.Qto, (2 * totalPulses), new int[] { (int)test.TolerRed, }))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.FixedStart,
|
|
||||||
test.Qfrom, test.Qto, 2 * totalPulses, new int[] { (int)test.TolerRed, }))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -627,21 +615,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
StartTime = (double)StateMachine.Time;
|
StartTime = (double)StateMachine.Time;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Opening the start/stop valve at the beginning of the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the start/stop valve at the beginning of the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -738,21 +716,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
EndTime = (double)StateMachine.Time;
|
EndTime = (double)StateMachine.Time;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -762,25 +730,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 2nd mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 2nd mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -795,25 +751,13 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -830,11 +774,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
|
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -906,10 +850,10 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
state.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(sensPath.RegisterReaders,
|
state.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(sensPath.RegisterReaders,
|
||||||
volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty));
|
volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty));
|
||||||
}
|
}
|
||||||
state.AddOperation(checkUiOp);
|
state.AddOperation(checkUiOp)
|
||||||
state.EnterState();
|
.AddOperations(readTempPressOps)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -1225,8 +1169,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -1235,10 +1178,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartMassCollection
|
|||||||
|
|
||||||
stopTestWOTransitionAfter:
|
stopTestWOTransitionAfter:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
+125
-137
@@ -77,7 +77,20 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
@@ -94,8 +107,20 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
|
|
||||||
|
|
||||||
@@ -122,12 +147,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -142,11 +167,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -160,11 +185,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -176,11 +201,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -202,11 +227,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
}
|
}
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Pump on", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Pump on", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(inPath.Pump, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(inPath.Pump, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -216,11 +241,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
while (e.Contains(Event.ValvesBusy));
|
while (e.Contains(Event.ValvesBusy));
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Start valve open", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Start valve open", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -232,11 +257,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -265,17 +290,15 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -289,11 +312,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
||||||
//-----------------------------------------------------------------
|
//-----------------------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Closing the start/stop valve before the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve before the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -317,8 +340,10 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
{
|
{
|
||||||
string[] startImages = new string[sensPath.RegisterReaders.Length];
|
string[] startImages = new string[sensPath.RegisterReaders.Length];
|
||||||
|
|
||||||
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp);
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps);
|
||||||
|
|
||||||
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
||||||
{
|
{
|
||||||
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
||||||
@@ -330,9 +355,9 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
state2.AddOperation(roi.GrabImageOp(startImages[i]));
|
state2.AddOperation(roi.GrabImageOp(startImages[i]));
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
state2.EnterState();
|
state2.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
@@ -347,11 +372,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
|
|
||||||
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
||||||
State.Create(string.Format("{0}({1}) : Entering begin-state", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Entering begin-state", test.Method, test.Name))
|
||||||
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp(sensPath.RegisterReaders))
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(checkUiOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation((dataEntryCmpnt as GenericDevices.IHasWMStatesForm).ShowTestStartFormOp(sensPath.RegisterReaders))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -404,18 +429,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.Synchro), test.Qfrom, test.Qto, (totalPulses * 5 / 4), new int[] { (int)test.TolerRed, }))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, (totalPulses * 5 / 4), new int[] { (int)test.TolerRed, }))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -425,17 +443,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
StartTime = (double)StateMachine.Time;
|
StartTime = (double)StateMachine.Time;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Opening the start/stop valve at the beginning of the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the start/stop valve at the beginning of the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, false, outPath))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -513,17 +525,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
EndTime = (double)StateMachine.Time;
|
EndTime = (double)StateMachine.Time;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the start/stop valve at the end of the fixed start test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -533,20 +539,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
log.WarnFormat("Start valve switch time on test end = {0} ms", cBrd.ValveOpenCloseTime);
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 2nd mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 2nd mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -560,20 +558,12 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Water level measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Water level measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(manualLevelMsrmnt ? tank.ManualReadVolumeOp(ref volumeBox) : tank.ReadStableVolumeOp(ref volumeBox, test.MassSpread))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(manualLevelMsrmnt ? tank.ManualReadVolumeOp(ref volumeBox) : tank.ReadStableVolumeOp(ref volumeBox, test.MassSpread))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -585,11 +575,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
|
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -609,8 +599,10 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
{
|
{
|
||||||
string[] endImages = new string[sensPath.RegisterReaders.Length];
|
string[] endImages = new string[sensPath.RegisterReaders.Length];
|
||||||
|
|
||||||
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
State state2 = State.Create(string.Format("{0}({1}) : Grabbing images", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp);
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps);
|
||||||
|
|
||||||
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
||||||
{
|
{
|
||||||
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
GenericDevices.IRoiForFixedStart roi = sensPath.RegisterReaders[i] as GenericDevices.IRoiForFixedStart;
|
||||||
@@ -622,9 +614,9 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
state2.AddOperation(roi.GrabImageOp(endImages[i]));
|
state2.AddOperation(roi.GrabImageOp(endImages[i]));
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
state2.EnterState();
|
state2.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
@@ -639,12 +631,11 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
|
|
||||||
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
Bridge.OnActivity(this, Strings.Enter_water_meter_data);
|
||||||
State.Create(string.Format("{0}({1}) : Entering the end-state", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Entering the end-state", test.Method, test.Name))
|
||||||
.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(sensPath.RegisterReaders,
|
|
||||||
volumeCTV, test.ErrLimLo + test.Uncertainty, test.ErrLimHi - test.Uncertainty))
|
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(dataEntryCmpnt.ShowTestEndFormOp(sensPath.RegisterReaders, volumeCTV, (test.ErrLimLo + test.Uncertainty), (test.ErrLimHi - test.Uncertainty)))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -878,10 +869,7 @@ namespace TBF.BenchControl.TestMethods.FixedStartTankCollection
|
|||||||
while (!e.Contains(Event.PreviousStopped));
|
while (!e.Contains(Event.PreviousStopped));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -31,65 +31,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
HeatMeters.TestParams heatMetersTestParams,
|
HeatMeters.TestParams heatMetersTestParams,
|
||||||
Config.Entities.DebugMode debugLevel)
|
Config.Entities.DebugMode debugLevel)
|
||||||
{
|
{
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
|
||||||
|
|
||||||
if (debugLevel == Config.Entities.DebugMode.Simulate)
|
if (debugLevel == Config.Entities.DebugMode.Simulate)
|
||||||
{
|
{
|
||||||
///
|
return Simulate(test, repetitionNr, isLastRepetition, compoundTestParams, heatMetersTestParams, debugLevel);
|
||||||
/// Test method simulation
|
}
|
||||||
///
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
|
||||||
|
|
||||||
if (compoundTestParams != null)
|
IList<Event> e; /// Events from currently running operations
|
||||||
{
|
|
||||||
if (test.Name.ToLower().Contains("nok")) MakeSimulatedCompound(test, 1, 0, 4.7f, 0.9f);
|
|
||||||
else MakeSimulatedCompound(test, 1, 0, 0.7f, 1.0f);
|
|
||||||
}
|
|
||||||
else if (heatMetersTestParams != null)
|
|
||||||
{
|
|
||||||
MakeSimulatedHeatMeters(test, 1, 0, 1.5f, 1000000, heatMetersTestParams.ErrorLimitLo, heatMetersTestParams.ErrorLimitHi, heatMetersTestParams.EvaluateVolume);
|
|
||||||
}
|
|
||||||
else if (test.Name.ToLower().Contains("q3")) MakeSimulated(test, 1, 0, -0.5f);
|
|
||||||
else if (test.Name.ToLower().Contains("q2")) MakeSimulated(test, 1, 0, 0.5f);
|
|
||||||
else if (test.Name.ToLower().Contains("q1")) MakeSimulated(test, 1, 0, -5.1f);
|
|
||||||
else MakeSimulated(test, 1, 0, 0.9f);
|
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Completed));
|
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
||||||
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(test.Name, BatchRslts.GetTestRslt(Results.Utils.GetTestName(test.Name, 1, 1), 0)));
|
|
||||||
allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file
|
|
||||||
|
|
||||||
//------------------------------------------------------------------
|
|
||||||
Bridge.OnActivity(this, string.Format("{0} simulation", test.Name));
|
|
||||||
//------------------------------------------------------------------
|
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Simulating {0}", test.Method, test.Name))
|
|
||||||
.AddOperation(checkUiOp)
|
|
||||||
.EnterState();
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
|
||||||
|
|
||||||
if (TestAndLogUiCmdStop(test, e)) retVal = Event.UiCmdStop;
|
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
|
||||||
IList<Event> retListSim = new List<Event>(1);
|
|
||||||
retListSim.Add(retVal);
|
|
||||||
return retListSim;
|
|
||||||
}
|
|
||||||
|
|
||||||
|
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
|
||||||
|
|
||||||
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
|
||||||
|
|
||||||
/// Notes:
|
|
||||||
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
|
||||||
/// float timeSec = 3600.0f * timeHr;
|
|
||||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
|
||||||
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
|
||||||
|
|
||||||
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
|
||||||
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
||||||
{
|
{
|
||||||
Elde.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Elde.FlowMeter.FlowMeter;
|
Elde.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Elde.FlowMeter.FlowMeter;
|
||||||
@@ -106,15 +55,48 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
if (rangeIx == -1)
|
if (rangeIx == -1)
|
||||||
{
|
{
|
||||||
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
||||||
retVal = Event.UiCmdStop;
|
return new List<Event> { Event.ConfigurationError }; /// or Event.UiCmdStop ???
|
||||||
goto stopTestWOStoppingDivGateEtc;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
/// Start the test, initialize test results
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -136,13 +118,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -156,12 +138,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -175,12 +157,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -192,12 +174,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -215,12 +197,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
int flowSetTime0 = StateMachine.Time;
|
int flowSetTime0 = StateMachine.Time;
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -253,15 +235,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
double Tc_last = 0;
|
double Tc_last = 0;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Checking if the temperature is stable", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(heatMetersPromptOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -298,17 +276,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -365,26 +341,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -412,28 +375,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, 0);
|
StartNewStatistics(StateMachine.Time, BatchRslts.Batch.BatchNr, test.Name, repetitionNr, 0);
|
||||||
|
|
||||||
/// Measurement loop - begin
|
/// Measurement loop - begin
|
||||||
State.Create("Read water meters")
|
State.Create(string.Format("{0}({1}) : Read water meters", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(readRegistersOp)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(readRegistersOp)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(queryEnd1)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
||||||
: null)
|
|
||||||
.AddOperation(queryEnd1)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -785,11 +735,10 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
||||||
}
|
}
|
||||||
@@ -798,10 +747,48 @@ namespace TBF.BenchControl.TestMethods.FlyingStart
|
|||||||
|
|
||||||
stopTestWOStoppingDivGateEtc:
|
stopTestWOStoppingDivGateEtc:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
IList<Event> Simulate(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
|
||||||
|
Compound.TestParams compoundTestParams,
|
||||||
|
HeatMeters.TestParams heatMetersTestParams,
|
||||||
|
Config.Entities.DebugMode debugLevel)
|
||||||
|
{
|
||||||
|
///
|
||||||
|
/// Test method simulation
|
||||||
|
///
|
||||||
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
|
|
||||||
|
if (compoundTestParams != null)
|
||||||
|
{
|
||||||
|
if (test.Name.ToLower().Contains("nok")) MakeSimulatedCompound(test, 1, 0, 4.7f, 0.9f);
|
||||||
|
else MakeSimulatedCompound(test, 1, 0, 0.7f, 1.0f);
|
||||||
|
}
|
||||||
|
else if (heatMetersTestParams != null)
|
||||||
|
{
|
||||||
|
MakeSimulatedHeatMeters(test, 1, 0, 1.5f, 1000000, heatMetersTestParams.ErrorLimitLo, heatMetersTestParams.ErrorLimitHi, heatMetersTestParams.EvaluateVolume);
|
||||||
|
}
|
||||||
|
else if (test.Name.ToLower().Contains("q3")) MakeSimulated(test, 1, 0, -0.5f);
|
||||||
|
else if (test.Name.ToLower().Contains("q2")) MakeSimulated(test, 1, 0, 0.5f);
|
||||||
|
else if (test.Name.ToLower().Contains("q1")) MakeSimulated(test, 1, 0, -5.1f);
|
||||||
|
else MakeSimulated(test, 1, 0, 0.9f);
|
||||||
|
|
||||||
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Completed));
|
||||||
|
Bridge.OnTestCompleted(this, new TestCompletedEventArgs(test.Name, BatchRslts.GetTestRslt(Results.Utils.GetTestName(test.Name, 1, 1), 0)));
|
||||||
|
allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file
|
||||||
|
|
||||||
|
//------------------------------------------------------------------
|
||||||
|
Bridge.OnActivity(this, string.Format("{0} simulation", test.Name));
|
||||||
|
//------------------------------------------------------------------
|
||||||
|
|
||||||
|
State.Create(string.Format("{0}({1}) : Simulating {0}", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.EnterState();
|
||||||
|
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
|
return new List<Event> { TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done };
|
||||||
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
+140
-200
@@ -82,7 +82,20 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true);
|
checkUiOp = new Operations.CheckUIOp(true);
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
float nextTestVolume = (singleTestParams != null) ? singleTestParams.NextTestVolume
|
float nextTestVolume = (singleTestParams != null) ? singleTestParams.NextTestVolume
|
||||||
: ((compoundTestParams != null) ? compoundTestParams.NextTestVolume
|
: ((compoundTestParams != null) ? compoundTestParams.NextTestVolume
|
||||||
@@ -94,11 +107,24 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
|
|
||||||
|
/// 'totalPulses' calculation has to be inside test repetition loop for this method !!!
|
||||||
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse;
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse;
|
||||||
int totalPulses = (int)((repetitionNr == 1 ? test.Volume : nextTestVolume) / LtrPerRefPulse + 0.5f);
|
int totalPulses = (int)((repetitionNr == 1 ? test.Volume : nextTestVolume) / LtrPerRefPulse + 0.5f);
|
||||||
|
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -116,11 +142,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
/// Measure the weight and skip emptying if there is enough room in the tank
|
/// Measure the weight and skip emptying if there is enough room in the tank
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -146,11 +172,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
drainTheTank = false;
|
drainTheTank = false;
|
||||||
#else
|
#else
|
||||||
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(scale.DrainValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(scale.DrainValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -183,13 +209,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -203,12 +229,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -222,12 +248,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -239,12 +265,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -261,12 +287,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -299,15 +325,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
double Tc_last = 0;
|
double Tc_last = 0;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(heatMetersPromptOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -344,17 +366,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -416,15 +436,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
///
|
///
|
||||||
/// Make sure tank draining completed
|
/// Make sure tank draining completed
|
||||||
///
|
///
|
||||||
IList<IOperation> extraOps = new List<IOperation>();
|
switch (DrainTheTank(scale, readTempPressOps))
|
||||||
if (heatMetersPath != null)
|
|
||||||
{
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
|
||||||
}
|
|
||||||
switch (DrainTheTank(scale, extraOps))
|
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -437,10 +449,10 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
/// Close the drain valve anyway
|
/// Close the drain valve anyway
|
||||||
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -455,15 +467,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
if (test.TimeFlow2Mass > 0)
|
if (test.TimeFlow2Mass > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -477,26 +485,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -521,26 +517,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.StartMeasurementOp(outPath,
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
(repetitionNr == 1) ? (Elde.TestMethods.Diverter | Elde.TestMethods.Synchro) : Elde.TestMethods.Synchro,
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, (repetitionNr == 1) ? Elde.TestMethods.Diverter | Elde.TestMethods.Synchro : Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -569,29 +554,16 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
|
|
||||||
/// Measurement loop - begin
|
/// Measurement loop - begin
|
||||||
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(readRegistersOp)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(readRegistersOp)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation((repetitionNr == 1) ? scale.ReadMassOp(ref Mass) : null)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation((repetitionNr == 1) ? cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr) : null)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(queryEnd1)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((repetitionNr == 1) ? scale.ReadMassOp(ref Mass) : null)
|
|
||||||
.AddOperation((repetitionNr == 1) ? cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr) : null)
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
||||||
: null)
|
|
||||||
.AddOperation(queryEnd1)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -657,12 +629,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
|
|
||||||
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen,
|
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
||||||
StateMachine.DefaultValvesClose))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -674,26 +645,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation((repetitionNr == 1) ? cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr) : null)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation((repetitionNr == 1) ? cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -705,25 +664,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -1087,21 +1034,17 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
if (TestAndLogUiCmdStop(test, e)) { if (retVal == Event.Done) retVal = Event.UiCmdStop; break; }
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.PreviousStopped));
|
while (!e.Contains(Event.PreviousStopped));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@@ -1143,14 +1086,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
|||||||
//-------------------------------------------------------------------
|
//-------------------------------------------------------------------
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Simulation", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Simulation", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.EnterState();
|
.EnterState();
|
||||||
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done };
|
||||||
IList<Event> retListSim = new List<Event>(1);
|
|
||||||
retListSim.Add(TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done);
|
|
||||||
return retListSim;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
+159
-234
@@ -96,7 +96,20 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
FloatBox switchTimeStart = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
FloatBox switchTimeStart = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
||||||
FloatBox switchTimeEnd = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
FloatBox switchTimeEnd = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
||||||
@@ -106,8 +119,20 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
/// Start the test, initialize test results
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -123,11 +148,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
/// Measure the weight and skip emptying if there is enough room in the tank
|
/// Measure the weight and skip emptying if there is enough room in the tank
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -144,7 +169,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
if (drainTheTank)
|
if (drainTheTank)
|
||||||
{
|
{
|
||||||
#if BERLIN || SENTEC
|
#if BERLIN || SENTEC
|
||||||
switch (DrainTheTank(outPath.Scale))
|
switch (DrainTheTank(outPath.Scale, readTempPressOps))
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -152,12 +177,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
|
|
||||||
drainTheTank = false;
|
drainTheTank = false;
|
||||||
#else
|
#else
|
||||||
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(scale.DrainValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(scale.DrainValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -190,13 +215,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -210,12 +235,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -229,12 +254,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -246,12 +271,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -268,12 +293,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -306,15 +331,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
double Tc_last = 0;
|
double Tc_last = 0;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(heatMetersPromptOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -325,12 +346,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
{
|
{
|
||||||
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
|
double Tw = (TempRefHi1.Val + TempRefHi2.Val) / 2;
|
||||||
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
|
double Tc = (TempRefLo1.Val + TempRefLo2.Val) / 2;
|
||||||
if (heatMetersTestParams.TempWarmLo <= Tw && Tw <= heatMetersTestParams.TempWarmHi &&
|
if ((heatMetersTestParams.TempWarmLo <= Tw) && (Tw <= heatMetersTestParams.TempWarmHi) &&
|
||||||
heatMetersTestParams.TempColdLo <= Tc && Tc <= heatMetersTestParams.TempColdHi &&
|
(heatMetersTestParams.TempColdLo <= Tc) && (Tc <= heatMetersTestParams.TempColdHi) &&
|
||||||
Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm &&
|
(Math.Abs(Tw - Tw_last) <= heatMetersTestParams.ChangeInTimeWarm) &&
|
||||||
Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold &&
|
(Math.Abs(Tc - Tc_last) <= heatMetersTestParams.ChangeInTimeCold) &&
|
||||||
Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm &&
|
(Math.Abs(TempRefHi1.Val - TempRefHi2.Val) <= heatMetersTestParams.DeltaTempWarm) &&
|
||||||
Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold)
|
(Math.Abs(TempRefLo1.Val - TempRefLo2.Val) <= heatMetersTestParams.DeltaTempCold))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -351,17 +372,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -422,15 +441,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
///
|
///
|
||||||
/// Make sure tank draining completed
|
/// Make sure tank draining completed
|
||||||
///
|
///
|
||||||
IList<IOperation> extraOps = new List<IOperation>();
|
switch (DrainTheTank(scale, readTempPressOps))
|
||||||
if (heatMetersPath != null)
|
|
||||||
{
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
|
||||||
}
|
|
||||||
switch (DrainTheTank(scale, extraOps))
|
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -443,10 +454,10 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
/// Close the drain valve anyway
|
/// Close the drain valve anyway
|
||||||
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -464,11 +475,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Activate ref. mass valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Activate ref. mass valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(compareValve, null))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(compareValve, null))
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -479,16 +490,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
/// Delay
|
/// Delay
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before the reference mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before the reference mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.AddOperation(new Operations.TimerOp(stabTime))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
.EnterState();
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
do {
|
||||||
.AddOperation(new Operations.TimerOp(stabTime))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -502,26 +509,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "Reference mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "Reference mass");
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the reference mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the reference mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref measuredRefMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref measuredRefMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -546,11 +541,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Deactivate ref. mass valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Deactivate ref. mass valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, compareValve))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, compareValve))
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -561,16 +556,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
/// Delay
|
/// Delay
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.AddOperation(new Operations.TimerOp(stabTime))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
.EnterState();
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
do {
|
||||||
.AddOperation(new Operations.TimerOp(stabTime))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -586,26 +577,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -640,26 +619,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -687,29 +653,16 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
|
|
||||||
/// Measurement loop - begin
|
/// Measurement loop - begin
|
||||||
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(readRegistersOp)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(readRegistersOp)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(cBrd.QueryMeasurementEndOp())
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
||||||
: null)
|
|
||||||
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
|
||||||
.AddOperation(cBrd.QueryMeasurementEndOp())
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -773,12 +726,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
|
|
||||||
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen,
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
||||||
StateMachine.DefaultValvesClose))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -790,26 +742,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -821,25 +761,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -1227,10 +1155,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
|||||||
while (!e.Contains(Event.PreviousStopped));
|
while (!e.Contains(Event.PreviousStopped));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
}
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
+135
-195
@@ -91,6 +91,19 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
Event retVal = Event.Done;
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
FloatBox switchTimeStart = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
FloatBox switchTimeStart = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
||||||
@@ -103,8 +116,20 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
/// Start the test, initialize test results
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, targetTotalPulses));
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, targetTotalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -120,11 +145,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
/// Measure the weight and skip emptying if there is enough room in the tank
|
/// Measure the weight and skip emptying if there is enough room in the tank
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -150,11 +175,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
drainTheTank = false;
|
drainTheTank = false;
|
||||||
#else
|
#else
|
||||||
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(scale.DrainValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(scale.DrainValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -187,13 +212,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -207,12 +232,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -226,12 +251,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -243,12 +268,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -265,12 +290,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -303,15 +328,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
double Tc_last = 0;
|
double Tc_last = 0;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(heatMetersPromptOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -348,17 +369,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -419,15 +438,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
///
|
///
|
||||||
/// Make sure tank draining completed
|
/// Make sure tank draining completed
|
||||||
///
|
///
|
||||||
IList<IOperation> extraOps = new List<IOperation>();
|
switch (DrainTheTank(scale, readTempPressOps))
|
||||||
if (heatMetersPath != null)
|
|
||||||
{
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
|
||||||
}
|
|
||||||
switch (DrainTheTank(scale, extraOps))
|
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -440,10 +451,10 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
/// Close the drain valve anyway
|
/// Close the drain valve anyway
|
||||||
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -459,15 +470,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
if (test.TimeFlow2Mass > 0)
|
if (test.TimeFlow2Mass > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -481,26 +488,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -524,26 +519,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.StartProlongedMeasurementOp(outPath,
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
Elde.TestMethods.Diverter | Elde.TestMethods.Synchro | Elde.TestMethods.MassAndContinue,
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
test.Qfrom, test.Qto, targetTotalPulses, targetMassPulses, filters))
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.StartProlongedMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro | Elde.TestMethods.MassAndContinue,
|
|
||||||
test.Qfrom, test.Qto, targetTotalPulses, targetMassPulses, filters))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -571,29 +555,16 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
|
|
||||||
/// Measurement loop - begin
|
/// Measurement loop - begin
|
||||||
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(readRegistersOp)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(readRegistersOp)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(cBrd.QueryMeasurementEndOp())
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
||||||
: null)
|
|
||||||
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
|
||||||
.AddOperation(cBrd.QueryMeasurementEndOp())
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -657,12 +628,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
|
|
||||||
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen,
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
||||||
StateMachine.DefaultValvesClose))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -674,26 +644,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -705,25 +663,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -1067,11 +1013,8 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
|
|
||||||
stopTestWOStoppingDivGateEtc:
|
stopTestWOStoppingDivGateEtc:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
}
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
|
||||||
|
|
||||||
|
|
||||||
IList<Event> Simulate(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
|
IList<Event> Simulate(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
|
||||||
@@ -1116,10 +1059,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
|||||||
.EnterState();
|
.EnterState();
|
||||||
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done };
|
||||||
IList<Event> retListSim = new List<Event>(1);
|
}
|
||||||
retListSim.Add(TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done);
|
|
||||||
return retListSim;
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
+148
-217
@@ -41,16 +41,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
return Simulate2(test, repetitionNr, isLastRepetition, compoundTestParams, heatMetersTestParams);
|
return Simulate2(test, repetitionNr, isLastRepetition, compoundTestParams, heatMetersTestParams);
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
||||||
|
|
||||||
IScale scale = outPath.Scale as IScale;
|
IScale scale = outPath.Scale as IScale;
|
||||||
if (scale == null)
|
if (scale == null)
|
||||||
{
|
{
|
||||||
Bridge.OnError(this, Strings.Missing_a_scale);
|
Bridge.OnError(this, Strings.Missing_a_scale);
|
||||||
e.Add(Event.ConfigurationError); /// or Event.UiCmdStop
|
return new List<Event> { Event.ConfigurationError }; /// or Event.UiCmdStop ???
|
||||||
return e;
|
}
|
||||||
}
|
|
||||||
|
|
||||||
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
||||||
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
||||||
@@ -69,23 +65,35 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
if (rangeIx == -1)
|
if (rangeIx == -1)
|
||||||
{
|
{
|
||||||
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
||||||
e.Add(Event.ConfigurationError); /// or Event.UiCmdStop
|
return new List<Event> { Event.ConfigurationError }; /// or Event.UiCmdStop ???
|
||||||
return e;
|
}
|
||||||
}
|
|
||||||
}
|
}
|
||||||
|
|
||||||
if (test.Volume > scale.Capacity * Constants.TankFullFactor)
|
if (test.Volume > scale.Capacity * Constants.TankFullFactor)
|
||||||
{
|
{
|
||||||
Bridge.OnError(this, Strings.Test_volume_exceeds_the_scale_capacity);
|
Bridge.OnError(this, Strings.Test_volume_exceeds_the_scale_capacity);
|
||||||
e.Add(Event.UiCmdStop);
|
return new List<Event> { Event.UiCmdStop };
|
||||||
return e;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
IList<Event> e; /// Events from currently running operations
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, heatMetersTestParams != null);
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if(benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if(benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if(outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if(benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if(benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if(benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if(heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if(heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if(heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if(heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
|
||||||
FloatBox switchTimeStart = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
FloatBox switchTimeStart = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
||||||
FloatBox switchTimeEnd = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
FloatBox switchTimeEnd = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
||||||
@@ -95,8 +103,20 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
/// Start the test, initialize test results
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -112,11 +132,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
/// Measure the weight and skip emptying if there is enough room in the tank
|
/// Measure the weight and skip emptying if there is enough room in the tank
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Checking available tank capacity", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -133,7 +153,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
if (drainTheTank)
|
if (drainTheTank)
|
||||||
{
|
{
|
||||||
#if BERLIN || SENTEC
|
#if BERLIN || SENTEC
|
||||||
switch (DrainTheTank(outPath.Scale))
|
switch (DrainTheTank(outPath.Scale, readTempPressOps))
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -141,12 +161,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
|
|
||||||
drainTheTank = false;
|
drainTheTank = false;
|
||||||
#else
|
#else
|
||||||
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Open the drain valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(scale.DrainValve, null))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(scale.DrainValve, null))
|
||||||
.EnterState();
|
.AddOperations(readTempPressOps)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -179,13 +199,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperation(heatMetersPromptOp)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -199,12 +219,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -218,12 +238,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -235,12 +255,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -257,12 +277,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
.AddOperation(heatMetersPromptOp)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(heatMetersPromptOp)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -295,15 +315,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
double Tc_last = 0;
|
double Tc_last = 0;
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Check temperature stabilized.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(heatMetersPromptOp)
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(heatMetersPromptOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
@@ -340,18 +356,16 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.EnterState();
|
||||||
.EnterState();
|
do {
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
@@ -411,15 +425,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
///
|
///
|
||||||
/// Make sure tank draining completed
|
/// Make sure tank draining completed
|
||||||
///
|
///
|
||||||
IList<IOperation> extraOps = new List<IOperation>();
|
switch (DrainTheTank(scale, readTempPressOps))
|
||||||
if (heatMetersPath != null)
|
|
||||||
{
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
|
||||||
extraOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
|
||||||
}
|
|
||||||
switch (DrainTheTank(scale, extraOps))
|
|
||||||
{
|
{
|
||||||
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
case Event.Error: { retVal = Event.Error; goto stopTest; }
|
||||||
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
case Event.UiCmdStop: { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -432,10 +438,10 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
/// Close the drain valve anyway
|
/// Close the drain valve anyway
|
||||||
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Close the drain valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(null, scale.DrainValve))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -451,15 +457,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
if (test.TimeFlow2Mass > 0)
|
if (test.TimeFlow2Mass > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before 1st mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
do {
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeFlow2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -473,25 +475,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "Start mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the start mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient == null) ? null : StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi))
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref StartMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -515,26 +506,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -562,29 +540,16 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
|
|
||||||
/// Measurement loop - begin
|
/// Measurement loop - begin
|
||||||
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(readRegistersOp)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(readRegistersOp)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(cBrd.QueryMeasurementEndOp())
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
||||||
: null)
|
|
||||||
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
|
||||||
.AddOperation(cBrd.QueryMeasurementEndOp())
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -650,12 +615,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
|
|
||||||
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
.AddOperation(new MettlerToledo.KeepReadingMassesOp())
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen,
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
||||||
StateMachine.DefaultValvesClose))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -667,26 +631,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before the 2nd mass measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadMassOp(ref Mass))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
.EnterState();
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadMassOp(ref Mass))
|
|
||||||
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -698,25 +650,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
|
else LogProcessDataHeaderHeatMeters(processDataLogger, "End mass");
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Measuring the end mass", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1))
|
|
||||||
.AddOperation(heatMetersPath == null ? null : heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(scale.ReadStableMassOp(ref EndMass, test.MassRepeats, test.MassSpread, test.MassMethod))
|
|
||||||
.AddOperation(new Operations.TimerOp(StableMassMsrmntTimeoutSec))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -1093,9 +1033,9 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do
|
||||||
{
|
{
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
@@ -1106,10 +1046,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
|
|
||||||
stopTestWOStoppingDivGateEtc:
|
stopTestWOStoppingDivGateEtc:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@@ -1154,10 +1091,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
.EnterState();
|
.EnterState();
|
||||||
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
IList<Event> e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done };
|
||||||
IList<Event> retListSim = new List<Event>(1);
|
|
||||||
retListSim.Add(TestAndLogUiCmdStop(test, e) ? Event.UiCmdStop : Event.Done);
|
|
||||||
return retListSim;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
@@ -1224,10 +1158,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
|||||||
allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file
|
allResults.Info(TestResult2CsvLine(test.Name, 0)); /// Append the results to the CSV-file
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal }; /// default 'retVal' value is Event.Done
|
||||||
IList<Event> retListSim = new List<Event>(1);
|
}
|
||||||
retListSim.Add(retVal);
|
|
||||||
return retListSim;
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
+96
-117
@@ -80,7 +80,20 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
Event retVal = Event.Done;
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
|
||||||
FloatBox switchTimeStart = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
FloatBox switchTimeStart = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
||||||
FloatBox switchTimeEnd = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
FloatBox switchTimeEnd = new FloatBox(0.001f); /// in seconds, initial value is 1 ms
|
||||||
@@ -92,8 +105,20 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
/// Start the test, initialize test results
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -121,12 +146,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -140,11 +165,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -158,11 +183,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -174,11 +199,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -195,11 +220,11 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -229,17 +254,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.EnterState();
|
||||||
.EnterState();
|
do {
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -297,22 +320,14 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Diverter | Elde.TestMethods.Synchro,
|
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -340,24 +355,15 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
|
|
||||||
/// Measurement loop - begin
|
/// Measurement loop - begin
|
||||||
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Reading watermeters", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(readRegistersOp)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(readRegistersOp)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(cBrd.QueryMeasurementEndOp())
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi)
|
|
||||||
: null)
|
|
||||||
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeStart, DiverterStart, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
|
||||||
.AddOperation(cBrd.QueryMeasurementEndOp())
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -404,11 +410,10 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
|
|
||||||
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
State.Create("SequenceBase : Transition : TestEnd - Default action")
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen,
|
.AddOperations(readTempPressOps)
|
||||||
StateMachine.DefaultValvesClose))
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -420,21 +425,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
Bridge.OnActivity(this, Strings.Wait_please);
|
Bridge.OnActivity(this, Strings.Wait_please);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before the water level measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before the water level measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(cBrd.ReadDiverterTransitionOp(outPath.Diverter, 2, 4, switchTimeEnd, DiverterEnd, BatchRslts.Batch.BatchNr, test.Name, repetitionNr))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeStop2Mass))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -446,20 +443,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
|
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Water level measurement", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Water level measurement", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp == null ? null : benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown == null ? null : benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(manualLevelMsrmnt ? tank.ManualReadVolumeOp(ref volumeBox) : tank.ReadStableVolumeOp(ref volumeBox, test.MassSpread))
|
||||||
.AddOperation(outPath.TempDiv == null ? null : outPath.TempDiv.ReadTempOp(ref TempDiv))
|
.AddOperation(processDataLoggingOp)
|
||||||
.AddOperation(benchPath.PressMtrUp == null ? null : benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown == null ? null : benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation((StateMachine.Ambient != null)
|
|
||||||
? StateMachine.Ambient.ReadAmbientOp(AmbTemp, AmbPress, AmbHumi) : null)
|
|
||||||
.AddOperation(manualLevelMsrmnt ? tank.ManualReadVolumeOp(ref volumeBox) : tank.ReadStableVolumeOp(ref volumeBox, test.MassSpread))
|
|
||||||
.AddOperation(processDataLoggingOp)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -767,11 +756,8 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
while (!e.Contains(Event.PreviousStopped));
|
while (!e.Contains(Event.PreviousStopped));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
}
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
|
||||||
|
|
||||||
|
|
||||||
public IList<Event> Simulate(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
|
public IList<Event> Simulate(Config.Entities.Test test, int repetitionNr, bool isLastRepetition,
|
||||||
@@ -784,11 +770,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
if ((outPath.Scale == null) || !(outPath.Scale is IVolumeMeter))
|
if ((outPath.Scale == null) || !(outPath.Scale is IVolumeMeter))
|
||||||
{
|
{
|
||||||
Bridge.OnError(this, Strings.Missing_a_tank_with_volume_measurement);
|
Bridge.OnError(this, Strings.Missing_a_tank_with_volume_measurement);
|
||||||
|
return new List<Event> { Event.ConfigurationError };
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
|
||||||
IList<Event> retListSim1 = new List<Event>(1);
|
|
||||||
retListSim1.Add(Event.ConfigurationError);
|
|
||||||
return retListSim1;
|
|
||||||
}
|
}
|
||||||
IVolumeMeter tank = outPath.Scale as IVolumeMeter;
|
IVolumeMeter tank = outPath.Scale as IVolumeMeter;
|
||||||
|
|
||||||
@@ -846,10 +828,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
|||||||
|
|
||||||
stopSimulation:
|
stopSimulation:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retListSim = new List<Event>(1);
|
|
||||||
retListSim.Add(retVal);
|
|
||||||
return retListSim;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -56,11 +56,7 @@ namespace TBF.BenchControl.TestMethods.GrabImage
|
|||||||
while (e.Contains(Event.CameraBusy));
|
while (e.Contains(Event.CameraBusy));
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, 1, Config.Entities.Progress.Completed));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, 1, Config.Entities.Progress.Completed));
|
||||||
|
return new List<Event> { retVal };
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -1,5 +1,5 @@
|
|||||||
///
|
///
|
||||||
/// Copyright (c) 2015-2016 Sensus Metering Systems
|
/// Copyright (c) 2015-2019 Sensus Slovensko a.s.
|
||||||
///
|
///
|
||||||
using System;
|
using System;
|
||||||
using System.Collections.Generic;
|
using System.Collections.Generic;
|
||||||
@@ -29,16 +29,38 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
|||||||
/// </returns>
|
/// </returns>
|
||||||
public IList<Event> Execute(Config.Entities.Test test, int repetitionNr, bool isLastRepetition, LeakTestParams testParams)
|
public IList<Event> Execute(Config.Entities.Test test, int repetitionNr, bool isLastRepetition, LeakTestParams testParams)
|
||||||
{
|
{
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
IList<Event> e ; /// Events from currently running operations
|
||||||
|
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
Event retVal = Event.Done;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, 1, inPath, benchPath, outPath, sensPath, 0));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, 1, inPath, benchPath, outPath, sensPath, heatMetersPath, 0));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, 1);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, 1);
|
||||||
|
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
@@ -47,17 +69,12 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -78,16 +95,11 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(pumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(pumpPower);
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Setting the water pressure", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the water pressure", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new Operations.TimerOp(5))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(new Operations.TimerOp(5))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -132,16 +144,11 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
|||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Maximum water pressure set", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Maximum water pressure set", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new Operations.TimerOp(testParams.DurationPMax))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(new Operations.TimerOp(testParams.DurationPMax))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -167,16 +174,11 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
|||||||
Bridge.OnActivity(this, Strings.Closing_valve_Pump_off);
|
Bridge.OnActivity(this, Strings.Closing_valve_Pump_off);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Closing the valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(new TBF.BenchControl.Elde.SetValvesOp(cBrd, true, outPath))
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -191,16 +193,11 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOff();
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOff();
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Closing the valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Closing the valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -222,16 +219,11 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
|||||||
Bridge.OnActivity(this, Strings.Test_in_progress);
|
Bridge.OnActivity(this, Strings.Test_in_progress);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new Operations.TimerOp(testParams.DurationLeak))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(new Operations.TimerOp(testParams.DurationLeak))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -379,21 +371,17 @@ namespace TBF.BenchControl.TestMethods.LeakTest
|
|||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.PreviousStopped));
|
while (!e.Contains(Event.PreviousStopped));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -57,11 +57,7 @@ namespace TBF.BenchControl.TestMethods.LiveStream
|
|||||||
while (!e.Contains(Event.OK));
|
while (!e.Contains(Event.OK));
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, 1, Config.Entities.Progress.Completed));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, 1, Config.Entities.Progress.Completed));
|
||||||
|
return new List<Event> { retVal };
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -1,5 +1,5 @@
|
|||||||
///
|
///
|
||||||
/// Copyright (c) 2015-2016 Sensus Metering Systems
|
/// Copyright (c) 2015-2019 Sensus Slovensko a.s.
|
||||||
///
|
///
|
||||||
using System;
|
using System;
|
||||||
using System.Collections.Generic;
|
using System.Collections.Generic;
|
||||||
@@ -29,16 +29,38 @@ namespace TBF.BenchControl.TestMethods.PMaxTest
|
|||||||
/// </returns>
|
/// </returns>
|
||||||
public IList<Event> Execute(Config.Entities.Test test, int repetitionNr, bool isLastRepetition, PMaxTestParams testParams)
|
public IList<Event> Execute(Config.Entities.Test test, int repetitionNr, bool isLastRepetition, PMaxTestParams testParams)
|
||||||
{
|
{
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
IList<Event> e; /// Events from currently running operations
|
||||||
|
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
Event retVal = Event.Done;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, 1, inPath, benchPath, outPath, sensPath, 0));
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, 1, inPath, benchPath, outPath, sensPath, heatMetersPath, 0));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, 1);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, 1);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -48,17 +70,12 @@ namespace TBF.BenchControl.TestMethods.PMaxTest
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
do {
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -79,16 +96,11 @@ namespace TBF.BenchControl.TestMethods.PMaxTest
|
|||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(pumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(pumpPower);
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Setting the water pressure", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the water pressure", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new Operations.TimerOp(5))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(new Operations.TimerOp(5))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -133,16 +145,11 @@ namespace TBF.BenchControl.TestMethods.PMaxTest
|
|||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
.AddOperation(new Operations.TimerOp(testParams.DurationPMax))
|
||||||
.AddOperation(benchPath.PressMtrUp.ReadPressureOp(ref PressUp))
|
.EnterState();
|
||||||
.AddOperation(benchPath.PressMtrDown.ReadPressureOp(ref PressDown))
|
do {
|
||||||
.AddOperation(benchPath.PressMtrDelta == null ? null : benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta))
|
|
||||||
.AddOperation(new Operations.TimerOp(testParams.DurationPMax))
|
|
||||||
.EnterState();
|
|
||||||
do
|
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -290,21 +297,17 @@ namespace TBF.BenchControl.TestMethods.PMaxTest
|
|||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.PreviousStopped));
|
while (!e.Contains(Event.PreviousStopped));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
}
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -55,23 +55,9 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
/// </returns>
|
/// </returns>
|
||||||
public IList<Event> Execute(Test test, int repetitionNr, bool isLastRepetition, TestParams testParams, DebugMode mode)
|
public IList<Event> Execute(Test test, int repetitionNr, bool isLastRepetition, TestParams testParams, DebugMode mode)
|
||||||
{
|
{
|
||||||
float simulatedError = 4.5f; /// %
|
float simulatedError = 4.5f; /// %
|
||||||
|
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
||||||
|
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
|
||||||
|
|
||||||
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
|
||||||
|
|
||||||
/// Notes:
|
|
||||||
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
|
||||||
/// float timeSec = 3600.0f * timeHr;
|
|
||||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
|
||||||
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
|
||||||
|
|
||||||
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
|
||||||
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
||||||
{
|
{
|
||||||
Elde.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Elde.FlowMeter.FlowMeter;
|
Elde.FlowMeter.FlowMeter eldeFM = outPath.FlowMeter as Elde.FlowMeter.FlowMeter;
|
||||||
@@ -88,15 +74,45 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
if (rangeIx == -1)
|
if (rangeIx == -1)
|
||||||
{
|
{
|
||||||
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
||||||
retVal = Event.UiCmdStop;
|
return new List<Event> { Event.ConfigurationError };
|
||||||
goto stopTestWOStoppingDivGateEtc;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
IList<Event> e; /// Events from currently running operations
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
||||||
|
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -108,13 +124,13 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create("Adjustment : Starting the pump")
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -129,11 +145,11 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -147,11 +163,11 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -163,11 +179,11 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -183,12 +199,12 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create("Adjustment : Setting the flow")
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -217,17 +233,15 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
@@ -296,12 +310,12 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
//tstRslt = MakeSimulated(test, 1, simulatedError);
|
//tstRslt = MakeSimulated(test, 1, simulatedError);
|
||||||
simulatedError *= 0.6f;
|
simulatedError *= 0.6f;
|
||||||
|
|
||||||
State.Create("Adjustment : Simulating the test")
|
State.Create(string.Format("{0}({1}) : Simulating the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(5))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(5))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -310,14 +324,13 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
}
|
}
|
||||||
else
|
else
|
||||||
{
|
{
|
||||||
State.Create("Adjustment : Starting the test")
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro,
|
.AddOperations(measureOperations)
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -478,12 +491,11 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
if (isLastRepetition || retVal == Event.UiCmdStop || retVal == Event.OpArgumentError
|
if (isLastRepetition || retVal == Event.UiCmdStop || retVal == Event.OpArgumentError
|
||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create("Adjustment : Stopping diverter, gate, etc.")
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -492,10 +504,7 @@ namespace TBF.BenchControl.TestMethods.PulsesTest
|
|||||||
|
|
||||||
stopTestWOStoppingDivGateEtc:
|
stopTestWOStoppingDivGateEtc:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -57,20 +57,6 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
{
|
{
|
||||||
float simulatedError = 4.5f; /// %
|
float simulatedError = 4.5f; /// %
|
||||||
|
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
|
||||||
|
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
|
||||||
|
|
||||||
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
|
||||||
|
|
||||||
/// Notes:
|
|
||||||
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
|
||||||
/// float timeSec = 3600.0f * timeHr;
|
|
||||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
|
||||||
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
|
||||||
|
|
||||||
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
int rangeIx = 0; /// Default range, used for non-Elde flowmeters
|
||||||
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
if (outPath.FlowMeter is Elde.FlowMeter.FlowMeter)
|
||||||
{
|
{
|
||||||
@@ -88,15 +74,47 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
if (rangeIx == -1)
|
if (rangeIx == -1)
|
||||||
{
|
{
|
||||||
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
Bridge.OnError(this, Strings.Flow_meter_temperature_range_does_not_fit_this_test_conditions);
|
||||||
retVal = Event.UiCmdStop;
|
return new List<Event> { Event.ConfigurationError };
|
||||||
goto stopTestWOStoppingDivGateEtc;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|
||||||
|
IList<Event> e; /// Events from currently running operations
|
||||||
|
Event retVal = Event.Done;
|
||||||
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
|
||||||
|
|
||||||
/// Start the test, initialize test results
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
||||||
|
|
||||||
|
|
||||||
|
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
|
||||||
|
State.Create(string.Format("{0}({1}) : Measuring process data", test.Method, test.Name))
|
||||||
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps)
|
||||||
|
.EnterState();
|
||||||
|
do {
|
||||||
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
|
}
|
||||||
|
while (e.Contains(Event.Busy));
|
||||||
|
|
||||||
|
/// Start the test, initialize test results
|
||||||
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -108,13 +126,13 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
///
|
///
|
||||||
State.Create("Adjustment : Starting the pump")
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
// .AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
//.AddOperation(new Operations.SetAllRegulValvesOp(inPath.RegulValves, inPath.RegulValvesPct, 60))
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -129,11 +147,11 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -147,11 +165,11 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -163,11 +181,11 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -183,12 +201,12 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create("Adjustment : Setting the flow")
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -217,18 +235,16 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Wait until the water temperature is within limits", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(benchPath.TempMtrUp.ReadTempOp(ref TempUp))
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(benchPath.TempMtrDown.ReadTempOp(ref TempDown))
|
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Next)) goto temperature_set;
|
if (e.Contains(Event.Next)) goto temperature_set;
|
||||||
|
|
||||||
if (TempUp.Val >= test.TempLimLo && TempUp.Val <= test.TempLimHi &&
|
if ((test.TempLimLo <= TempUp.Val) && (TempUp.Val <= test.TempLimHi) &&
|
||||||
TempDown.Val >= test.TempLimLo && TempDown.Val <= test.TempLimHi)
|
(test.TempLimLo <= TempDown.Val) && (TempDown.Val <= test.TempLimHi))
|
||||||
{
|
{
|
||||||
goto temperature_set;
|
goto temperature_set;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
@@ -296,12 +312,12 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
//tstRslt = MakeSimulated(test, 1, simulatedError);
|
//tstRslt = MakeSimulated(test, 1, simulatedError);
|
||||||
simulatedError *= 0.6f;
|
simulatedError *= 0.6f;
|
||||||
|
|
||||||
State.Create("Adjustment : Simulating the test")
|
State.Create(string.Format("{0}({1}) : Simulating the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(5))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(5))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -310,14 +326,13 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
}
|
}
|
||||||
else
|
else
|
||||||
{
|
{
|
||||||
State.Create("Adjustment : Starting the test")
|
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro,
|
.AddOperations(measureOperations)
|
||||||
test.Qfrom, test.Qto, totalPulses, filters))
|
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses, filters))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
@@ -474,12 +489,11 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
if (isLastRepetition || retVal == Event.UiCmdStop || retVal == Event.OpArgumentError
|
if (isLastRepetition || retVal == Event.UiCmdStop || retVal == Event.OpArgumentError
|
||||||
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
|| retVal == Event.Error || retVal == Event.ConfigurationError)
|
||||||
{
|
{
|
||||||
State.Create("Adjustment : Stopping diverter, gate, etc.")
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
}
|
}
|
||||||
@@ -488,10 +502,7 @@ namespace TBF.BenchControl.TestMethods.PulsesTestManual
|
|||||||
|
|
||||||
stopTestWOStoppingDivGateEtc:
|
stopTestWOStoppingDivGateEtc:
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -1,5 +1,5 @@
|
|||||||
///
|
///
|
||||||
/// Copyright (c) 2017 Sensus Metering Systems
|
/// Copyright (c) 2017-2019 Sensus Slovensko a.s.
|
||||||
///
|
///
|
||||||
using System;
|
using System;
|
||||||
using System.Collections.Generic;
|
using System.Collections.Generic;
|
||||||
@@ -19,28 +19,33 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
|
|
||||||
public IList<Event> Execute(Test test, GenericDevices.ICameraDisplay display, int repetitionNr, bool isLastRepetition)
|
public IList<Event> Execute(Test test, GenericDevices.ICameraDisplay display, int repetitionNr, bool isLastRepetition)
|
||||||
{
|
{
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
IList<Event> e; /// Events from currently running operations
|
||||||
|
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
|
||||||
Event retVal = Event.Done;
|
Event retVal = Event.Done;
|
||||||
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
/// Operations
|
|
||||||
checkUiOp = new Operations.CheckUIOp(true);
|
checkUiOp = new Operations.CheckUIOp(true);
|
||||||
processDataLoggingOp = null;
|
processDataLoggingOp = null;
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
|
|
||||||
/// LtrPerRefPulse and totalPulses are only to make time estimates
|
/// LtrPerRefPulse and totalPulses are only to make time estimates
|
||||||
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
|
||||||
/// Notes:
|
|
||||||
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
|
||||||
/// float timeSec = 3600.0f * timeHr;
|
|
||||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
|
||||||
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
|
||||||
|
|
||||||
//====================
|
//====================
|
||||||
// Start the test
|
// Start the test
|
||||||
//====================
|
//====================
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, totalPulses));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -50,11 +55,11 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
///
|
///
|
||||||
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
if (inPath.Pump is GenericDevices.IPumpFM) (inPath.Pump as GenericDevices.IPumpFM).TurnOn(test.PumpPower);
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(inPath.Pump != null ? cBrd.SetValvesOp(inPath.Pump, null) : null)
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
|
|
||||||
@@ -67,11 +72,11 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
if (test.TimePump2StartV > 0)
|
if (test.TimePump2StartV > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting after the pump started", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimePump2StartV))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -85,11 +90,11 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
if (benchPath.StopBFValve != null)
|
if (benchPath.StopBFValve != null)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Opening the stop backflow valve", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(StateMachine.ControlBoard.SetValvesOp(benchPath.StopBFValve, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
@@ -101,11 +106,11 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
if (test.TimeBeforeFlow > 0)
|
if (test.TimeBeforeFlow > 0)
|
||||||
{
|
{
|
||||||
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Waiting before flow setting process starts", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(new Operations.TimerOp(test.TimeBeforeFlow))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
@@ -122,11 +127,11 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
Bridge.OnActivity(this, Strings.Setting_the_flow);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.FlowSetting));
|
||||||
|
|
||||||
@@ -169,7 +174,9 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
//---------------------------------------------------------
|
//---------------------------------------------------------
|
||||||
|
|
||||||
State detection = State.Create(string.Format("{0}({1}) : Detection of ROI-s", test.Method, test.Name))
|
State detection = State.Create(string.Format("{0}({1}) : Detection of ROI-s", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp);
|
.AddOperation(checkUiOp)
|
||||||
|
.AddOperations(readTempPressOps);
|
||||||
|
|
||||||
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
for (int i = 0; i < sensPath.RegisterReaders.Length; i++)
|
||||||
{
|
{
|
||||||
GenericDevices.IRoi roi = sensPath.RegisterReaders[i] as GenericDevices.IRoi;
|
GenericDevices.IRoi roi = sensPath.RegisterReaders[i] as GenericDevices.IRoi;
|
||||||
@@ -179,23 +186,15 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
imageNames[i] = roi.ImageFileNamePrefix + "detected.jpg";
|
imageNames[i] = roi.ImageFileNamePrefix + "detected.jpg";
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
detection.EnterState();
|
detection.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
|
||||||
|
|
||||||
if (e.Contains(Event.Error))
|
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||||
{
|
if (TestAndLogUiCmdStop(test,e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||||
retVal = Event.Error;
|
|
||||||
goto stopTest;
|
|
||||||
}
|
|
||||||
if (TestAndLogUiCmdStop(test,e))
|
|
||||||
{
|
|
||||||
retVal = Event.UiCmdStop;
|
|
||||||
goto stopTest;
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
while (e.Contains(Event.CameraBusy));
|
while (e.Contains(Event.CameraBusy));
|
||||||
|
|
||||||
@@ -215,10 +214,10 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
string title = Strings.Select_images_and_press_Retry_to_retry_RoI_detection;
|
string title = Strings.Select_images_and_press_Retry_to_retry_RoI_detection;
|
||||||
State.Create(string.Format("{0}({1}) : Select images and press Retry to retry RoI detection", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Select images and press Retry to retry RoI detection", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation((display == null) ? null : display.ShowStaticImageOp(imageNames, title))
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation((display == null) ? null : display.ShowStaticImageOp(imageNames, title))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
|
|
||||||
if (TestAndLogUiCmdStop(test, e))
|
if (TestAndLogUiCmdStop(test, e))
|
||||||
@@ -264,18 +263,14 @@ namespace TBF.BenchControl.TestMethods.RoiDetection
|
|||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test, e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test, e)) goto stopTest;
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.PreviousStopped));
|
while (!e.Contains(Event.PreviousStopped));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
return new List<Event> { retVal };
|
||||||
IList<Event> retList = new List<Event>(1);
|
|
||||||
retList.Add(retVal);
|
|
||||||
return retList;
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -34,30 +34,39 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
if (debugLevel == Config.Entities.DebugMode.Simulate)
|
if (debugLevel == Config.Entities.DebugMode.Simulate)
|
||||||
{
|
{
|
||||||
/// TODO: Test method simulation
|
/// TODO: Test method simulation
|
||||||
IList<Event> retListSim = new List<Event>(1);
|
return new List<Event> { Event.Done };
|
||||||
retListSim.Add(Event.Done);
|
|
||||||
return retListSim;
|
|
||||||
}
|
}
|
||||||
|
|
||||||
IList<Event> e = new List<Event>(); /// Events from currently running operations
|
IList<Event> e; /// Events from currently running operations
|
||||||
|
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
||||||
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
|
||||||
|
|
||||||
|
IList<IOperation> readTempPressOps = new List<IOperation>();
|
||||||
|
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
|
||||||
|
if (benchPath.TempMtrDown != null) readTempPressOps.Add(benchPath.TempMtrDown.ReadTempOp(ref TempDown));
|
||||||
|
if (outPath.TempDiv != null) readTempPressOps.Add(outPath.TempDiv.ReadTempOp(ref TempDiv));
|
||||||
|
if (benchPath.PressMtrUp != null) readTempPressOps.Add(benchPath.PressMtrUp.ReadPressureOp(ref PressUp));
|
||||||
|
if (benchPath.PressMtrDown != null) readTempPressOps.Add(benchPath.PressMtrDown.ReadPressureOp(ref PressDown));
|
||||||
|
if (benchPath.PressMtrDelta != null) readTempPressOps.Add(benchPath.PressMtrDelta.ReadPressureOp(ref PressDelta));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm1.ReadTempOp(ref TempRefHi1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefWarm2.ReadTempOp(ref TempRefHi2));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold1.ReadTempOp(ref TempRefLo1));
|
||||||
|
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
|
||||||
|
|
||||||
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeStart = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
float switchTimeEnd = 0.001f; /// in seconds, original vale is 1 ms
|
||||||
|
|
||||||
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
|
|
||||||
|
|
||||||
/// Specific for combined meters
|
/// Specific for combined meters
|
||||||
int[] lastWMPulses = new int[Config.Data.WMsCount];
|
int[] lastWMPulses = new int[Config.Data.WMsCount];
|
||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : stopTest diverter gate etc", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : stopTest diverter gate etc", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
.EnterState();
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
}
|
}
|
||||||
@@ -80,7 +89,7 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
//====================================
|
//====================================
|
||||||
loop:
|
loop:
|
||||||
/// Start the test, initialize test results
|
/// Start the test, initialize test results
|
||||||
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, (int)totalPulses));
|
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
|
||||||
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
|
||||||
TestStartTime = DateTime.Now;
|
TestStartTime = DateTime.Now;
|
||||||
|
|
||||||
@@ -127,7 +136,6 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
foreach (var camera in cameras) measureOperations.Add(camera.MeasurementOp());
|
foreach (var camera in cameras) measureOperations.Add(camera.MeasurementOp());
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
int flowDetectTime0 = StateMachine.Time;
|
int flowDetectTime0 = StateMachine.Time;
|
||||||
int flowDetectTime = 0;
|
int flowDetectTime = 0;
|
||||||
float estFlowSetTime = 100.0f;
|
float estFlowSetTime = 100.0f;
|
||||||
@@ -136,13 +144,13 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
Bridge.OnActivity(this, Strings.Switching_flow_detection);
|
Bridge.OnActivity(this, Strings.Switching_flow_detection);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Starting the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation((inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOnOp(test.PumpPower) : null)
|
.AddOperations(measureOperations)
|
||||||
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
.AddOperation((inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOnOp(test.PumpPower) : null)
|
||||||
.EnterState();
|
.AddOperation(cBrd.SetValvesOp(inPath.Pump, null))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
||||||
|
|
||||||
@@ -152,12 +160,12 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
|
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Setting the initial flow", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Setting the initial flow", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(outPath.RegulValve.SetFlowAndMeasureOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec, (float)test.TolerRed))
|
.AddOperations(measureOperations)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.SetFlowAndMeasureOp(outPath.FlowMeter, test.Qfrom, test.Qto, outPath.PidCoef, RefFlow, FlowSettingTimeoutSec, (float)test.TolerRed))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
||||||
|
|
||||||
@@ -212,12 +220,12 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
{
|
{
|
||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Changing the RV position", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Changing the RV position", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperations(measureOperations)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(outPath.RegulValve.ChangeRegulValvePositionOp(rvPulse))
|
.AddOperations(measureOperations)
|
||||||
.EnterState();
|
.AddOperation(outPath.RegulValve.ChangeRegulValvePositionOp(rvPulse))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
Bridge.OnTestProgress(this, new TestProgressEventArgs(test, repetitionNr, Config.Entities.Progress.SwitchingFlowDetection));
|
||||||
|
|
||||||
@@ -334,12 +342,12 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
Bridge.OnActivity(this, Strings.Test_completed);
|
Bridge.OnActivity(this, Strings.Test_completed);
|
||||||
//------------------------------------------------
|
//------------------------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : {2}", test.Method, test.Name, Strings.Stop_the_pump))
|
State.Create(string.Format("{0}({1}) : {2}", test.Method, test.Name, Strings.Stop_the_pump))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
.AddOperations(readTempPressOps)
|
||||||
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
||||||
.EnterState();
|
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
||||||
do
|
.EnterState();
|
||||||
{
|
do {
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
}
|
}
|
||||||
@@ -349,10 +357,10 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
//--------------------------------
|
//--------------------------------
|
||||||
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Stopping diverter, gate, etc.", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.StopPreviousOp())
|
.AddOperations(readTempPressOps)
|
||||||
|
.AddOperation(cBrd.StopPreviousOp())
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
if (TestAndLogUiCmdStop(test,e)) goto stopTest;
|
||||||
}
|
}
|
||||||
@@ -463,59 +471,49 @@ namespace TBF.BenchControl.TestMethods.SensitivityTest
|
|||||||
{
|
{
|
||||||
/// Stop the pump
|
/// Stop the pump
|
||||||
State.Create(string.Format("{0}({1}) : Test(s) completed -> Stopping the pump", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : Test(s) completed -> Stopping the pump", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
.AddOperation(cBrd.SetValvesOp(null, inPath.Pump))
|
||||||
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) goto error;
|
if (e.Contains(Event.Error)) goto error;
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.ValvesSet) || ((inPath.Pump is GenericDevices.IPumpFM) && !e.Contains(Event.TurnPumpOnOffDone)));
|
while (!e.Contains(Event.ValvesSet) || ((inPath.Pump is GenericDevices.IPumpFM) && !e.Contains(Event.TurnPumpOnOffDone)));
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create the return value - a list with one event Event.Done - and return
|
return new List<Event> { Event.Done };
|
||||||
IList<Event> retval1 = new List<Event>(1);
|
|
||||||
retval1.Add(Event.Done);
|
|
||||||
return retval1;
|
|
||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
stopTest:
|
stopTest:
|
||||||
|
|
||||||
State.Create(string.Format("{0}({1}) : User selected STOP -> Closing the valves", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : User selected STOP -> Closing the valves", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
||||||
.AddOperation(cBrd.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
.AddOperation(cBrd.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) goto error;
|
if (e.Contains(Event.Error)) goto error;
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.ValvesSet));
|
while (!e.Contains(Event.ValvesSet));
|
||||||
|
|
||||||
IList<Event> retval2 = new List<Event>(1);
|
return new List<Event> { Event.UiCmdStop };
|
||||||
retval2.Add(Event.UiCmdStop);
|
|
||||||
return retval2;
|
|
||||||
|
|
||||||
//====================================
|
//====================================
|
||||||
error:
|
error:
|
||||||
State.Create(string.Format("{0}({1}) : close_before_error", test.Method, test.Name))
|
State.Create(string.Format("{0}({1}) : close_before_error", test.Method, test.Name))
|
||||||
.AddOperation(checkUiOp)
|
.AddOperation(checkUiOp)
|
||||||
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
.AddOperation((inPath != null && inPath.Pump is GenericDevices.IPumpFM) ? (inPath.Pump as GenericDevices.IPumpFM).TurnOffOp() : null)
|
||||||
.AddOperation(cBrd.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
.AddOperation(cBrd.SetValvesOp(StateMachine.DefaultValvesOpen, StateMachine.DefaultValvesClose))
|
||||||
.EnterState();
|
.EnterState();
|
||||||
do
|
do {
|
||||||
{
|
|
||||||
e = StateMachine.WaitRunDevsRunOps();
|
e = StateMachine.WaitRunDevsRunOps();
|
||||||
if (e.Contains(Event.Error)) break;
|
if (e.Contains(Event.Error)) break;
|
||||||
}
|
}
|
||||||
while (!e.Contains(Event.ValvesSet));
|
while (!e.Contains(Event.ValvesSet));
|
||||||
|
|
||||||
IList<Event> retval3 = new List<Event>(1);
|
return new List<Event> { Event.Error };
|
||||||
retval3.Add(Event.Error);
|
}
|
||||||
return retval3;
|
|
||||||
}
|
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
@@ -291,7 +291,6 @@ namespace TBF.BenchControl.TestMethods.iPerlCommunication
|
|||||||
modelessDlg = null; /// Modeless dialog is closed now
|
modelessDlg = null; /// Modeless dialog is closed now
|
||||||
}
|
}
|
||||||
|
|
||||||
/// Create a list with one item 'retVal' (default is Event.Done) and return it
|
|
||||||
return new List<Event> { Event.Done };
|
return new List<Event> { Event.Done };
|
||||||
}
|
}
|
||||||
|
|
||||||
|
|||||||
@@ -29,5 +29,5 @@ using System.Runtime.InteropServices;
|
|||||||
// Build Number
|
// Build Number
|
||||||
// Revision
|
// Revision
|
||||||
//
|
//
|
||||||
[assembly: AssemblyVersion("2.18.1168.0")]
|
[assembly: AssemblyVersion("2.18.1171.0")]
|
||||||
[assembly: AssemblyFileVersion("2.18.1168.0")]
|
[assembly: AssemblyFileVersion("2.18.1171.0")]
|
||||||
|
|||||||
+92
-14
@@ -33,6 +33,12 @@ namespace TBF.Screens
|
|||||||
{
|
{
|
||||||
System.ComponentModel.ComponentResourceManager resources = new System.ComponentModel.ComponentResourceManager(typeof(ProcessTabPageExCtrl));
|
System.ComponentModel.ComponentResourceManager resources = new System.ComponentModel.ComponentResourceManager(typeof(ProcessTabPageExCtrl));
|
||||||
this.splitContainer1 = new System.Windows.Forms.SplitContainer();
|
this.splitContainer1 = new System.Windows.Forms.SplitContainer();
|
||||||
|
this.tLoCmpntLabel = new System.Windows.Forms.Label();
|
||||||
|
this.tLoDataLabel = new System.Windows.Forms.Label();
|
||||||
|
this.tLoLabel = new System.Windows.Forms.Label();
|
||||||
|
this.tHiCmpntLabel = new System.Windows.Forms.Label();
|
||||||
|
this.tHiDataLabel = new System.Windows.Forms.Label();
|
||||||
|
this.tHiLabel = new System.Windows.Forms.Label();
|
||||||
this.pumpPctTextBox = new System.Windows.Forms.TextBox();
|
this.pumpPctTextBox = new System.Windows.Forms.TextBox();
|
||||||
this.pictureBox1 = new System.Windows.Forms.PictureBox();
|
this.pictureBox1 = new System.Windows.Forms.PictureBox();
|
||||||
this.flowMeterPictureBox = new System.Windows.Forms.PictureBox();
|
this.flowMeterPictureBox = new System.Windows.Forms.PictureBox();
|
||||||
@@ -118,6 +124,12 @@ namespace TBF.Screens
|
|||||||
//
|
//
|
||||||
// splitContainer1.Panel1
|
// splitContainer1.Panel1
|
||||||
//
|
//
|
||||||
|
this.splitContainer1.Panel1.Controls.Add(this.tLoCmpntLabel);
|
||||||
|
this.splitContainer1.Panel1.Controls.Add(this.tLoDataLabel);
|
||||||
|
this.splitContainer1.Panel1.Controls.Add(this.tLoLabel);
|
||||||
|
this.splitContainer1.Panel1.Controls.Add(this.tHiCmpntLabel);
|
||||||
|
this.splitContainer1.Panel1.Controls.Add(this.tHiDataLabel);
|
||||||
|
this.splitContainer1.Panel1.Controls.Add(this.tHiLabel);
|
||||||
this.splitContainer1.Panel1.Controls.Add(this.pumpPctTextBox);
|
this.splitContainer1.Panel1.Controls.Add(this.pumpPctTextBox);
|
||||||
this.splitContainer1.Panel1.Controls.Add(this.pictureBox1);
|
this.splitContainer1.Panel1.Controls.Add(this.pictureBox1);
|
||||||
this.splitContainer1.Panel1.Controls.Add(this.flowMeterPictureBox);
|
this.splitContainer1.Panel1.Controls.Add(this.flowMeterPictureBox);
|
||||||
@@ -187,6 +199,66 @@ namespace TBF.Screens
|
|||||||
this.splitContainer1.SplitterWidth = 1;
|
this.splitContainer1.SplitterWidth = 1;
|
||||||
this.splitContainer1.TabIndex = 182;
|
this.splitContainer1.TabIndex = 182;
|
||||||
//
|
//
|
||||||
|
// tLoCmpntLabel
|
||||||
|
//
|
||||||
|
this.tLoCmpntLabel.AutoSize = true;
|
||||||
|
this.tLoCmpntLabel.Location = new System.Drawing.Point(367, 218);
|
||||||
|
this.tLoCmpntLabel.Name = "tLoCmpntLabel";
|
||||||
|
this.tLoCmpntLabel.Size = new System.Drawing.Size(52, 13);
|
||||||
|
this.tLoCmpntLabel.TabIndex = 250;
|
||||||
|
this.tLoCmpntLabel.Text = "tLoCmpnt";
|
||||||
|
this.tLoCmpntLabel.Visible = false;
|
||||||
|
//
|
||||||
|
// tLoDataLabel
|
||||||
|
//
|
||||||
|
this.tLoDataLabel.AutoSize = true;
|
||||||
|
this.tLoDataLabel.Location = new System.Drawing.Point(367, 234);
|
||||||
|
this.tLoDataLabel.Name = "tLoDataLabel";
|
||||||
|
this.tLoDataLabel.Size = new System.Drawing.Size(45, 13);
|
||||||
|
this.tLoDataLabel.TabIndex = 249;
|
||||||
|
this.tLoDataLabel.Text = "tLoData";
|
||||||
|
this.tLoDataLabel.Visible = false;
|
||||||
|
//
|
||||||
|
// tLoLabel
|
||||||
|
//
|
||||||
|
this.tLoLabel.AutoSize = true;
|
||||||
|
this.tLoLabel.Location = new System.Drawing.Point(306, 234);
|
||||||
|
this.tLoLabel.Name = "tLoLabel";
|
||||||
|
this.tLoLabel.Size = new System.Drawing.Size(48, 13);
|
||||||
|
this.tLoLabel.TabIndex = 248;
|
||||||
|
this.tLoLabel.Text = "T lo [°C]:";
|
||||||
|
this.tLoLabel.Visible = false;
|
||||||
|
//
|
||||||
|
// tHiCmpntLabel
|
||||||
|
//
|
||||||
|
this.tHiCmpntLabel.AutoSize = true;
|
||||||
|
this.tHiCmpntLabel.Location = new System.Drawing.Point(367, 178);
|
||||||
|
this.tHiCmpntLabel.Name = "tHiCmpntLabel";
|
||||||
|
this.tHiCmpntLabel.Size = new System.Drawing.Size(50, 13);
|
||||||
|
this.tHiCmpntLabel.TabIndex = 247;
|
||||||
|
this.tHiCmpntLabel.Text = "tHiCmpnt";
|
||||||
|
this.tHiCmpntLabel.Visible = false;
|
||||||
|
//
|
||||||
|
// tHiDataLabel
|
||||||
|
//
|
||||||
|
this.tHiDataLabel.AutoSize = true;
|
||||||
|
this.tHiDataLabel.Location = new System.Drawing.Point(367, 194);
|
||||||
|
this.tHiDataLabel.Name = "tHiDataLabel";
|
||||||
|
this.tHiDataLabel.Size = new System.Drawing.Size(43, 13);
|
||||||
|
this.tHiDataLabel.TabIndex = 246;
|
||||||
|
this.tHiDataLabel.Text = "tHiData";
|
||||||
|
this.tHiDataLabel.Visible = false;
|
||||||
|
//
|
||||||
|
// tHiLabel
|
||||||
|
//
|
||||||
|
this.tHiLabel.AutoSize = true;
|
||||||
|
this.tHiLabel.Location = new System.Drawing.Point(306, 194);
|
||||||
|
this.tHiLabel.Name = "tHiLabel";
|
||||||
|
this.tHiLabel.Size = new System.Drawing.Size(48, 13);
|
||||||
|
this.tHiLabel.TabIndex = 245;
|
||||||
|
this.tHiLabel.Text = "T hi [°C]:";
|
||||||
|
this.tHiLabel.Visible = false;
|
||||||
|
//
|
||||||
// pumpPctTextBox
|
// pumpPctTextBox
|
||||||
//
|
//
|
||||||
this.pumpPctTextBox.Location = new System.Drawing.Point(797, 372);
|
this.pumpPctTextBox.Location = new System.Drawing.Point(797, 372);
|
||||||
@@ -613,7 +685,7 @@ namespace TBF.Screens
|
|||||||
// prInCmpntLabel
|
// prInCmpntLabel
|
||||||
//
|
//
|
||||||
this.prInCmpntLabel.AutoSize = true;
|
this.prInCmpntLabel.AutoSize = true;
|
||||||
this.prInCmpntLabel.Location = new System.Drawing.Point(141, 124);
|
this.prInCmpntLabel.Location = new System.Drawing.Point(141, 178);
|
||||||
this.prInCmpntLabel.Name = "prInCmpntLabel";
|
this.prInCmpntLabel.Name = "prInCmpntLabel";
|
||||||
this.prInCmpntLabel.Size = new System.Drawing.Size(55, 13);
|
this.prInCmpntLabel.Size = new System.Drawing.Size(55, 13);
|
||||||
this.prInCmpntLabel.TabIndex = 194;
|
this.prInCmpntLabel.TabIndex = 194;
|
||||||
@@ -622,7 +694,7 @@ namespace TBF.Screens
|
|||||||
// prOutCmpntLabel
|
// prOutCmpntLabel
|
||||||
//
|
//
|
||||||
this.prOutCmpntLabel.AutoSize = true;
|
this.prOutCmpntLabel.AutoSize = true;
|
||||||
this.prOutCmpntLabel.Location = new System.Drawing.Point(598, 124);
|
this.prOutCmpntLabel.Location = new System.Drawing.Point(598, 178);
|
||||||
this.prOutCmpntLabel.Name = "prOutCmpntLabel";
|
this.prOutCmpntLabel.Name = "prOutCmpntLabel";
|
||||||
this.prOutCmpntLabel.Size = new System.Drawing.Size(63, 13);
|
this.prOutCmpntLabel.Size = new System.Drawing.Size(63, 13);
|
||||||
this.prOutCmpntLabel.TabIndex = 193;
|
this.prOutCmpntLabel.TabIndex = 193;
|
||||||
@@ -631,7 +703,7 @@ namespace TBF.Screens
|
|||||||
// tOutCmpntLabel
|
// tOutCmpntLabel
|
||||||
//
|
//
|
||||||
this.tOutCmpntLabel.AutoSize = true;
|
this.tOutCmpntLabel.AutoSize = true;
|
||||||
this.tOutCmpntLabel.Location = new System.Drawing.Point(598, 162);
|
this.tOutCmpntLabel.Location = new System.Drawing.Point(598, 218);
|
||||||
this.tOutCmpntLabel.Name = "tOutCmpntLabel";
|
this.tOutCmpntLabel.Name = "tOutCmpntLabel";
|
||||||
this.tOutCmpntLabel.Size = new System.Drawing.Size(57, 13);
|
this.tOutCmpntLabel.Size = new System.Drawing.Size(57, 13);
|
||||||
this.tOutCmpntLabel.TabIndex = 192;
|
this.tOutCmpntLabel.TabIndex = 192;
|
||||||
@@ -640,7 +712,7 @@ namespace TBF.Screens
|
|||||||
// tInCmpntLabel
|
// tInCmpntLabel
|
||||||
//
|
//
|
||||||
this.tInCmpntLabel.AutoSize = true;
|
this.tInCmpntLabel.AutoSize = true;
|
||||||
this.tInCmpntLabel.Location = new System.Drawing.Point(141, 162);
|
this.tInCmpntLabel.Location = new System.Drawing.Point(141, 218);
|
||||||
this.tInCmpntLabel.Name = "tInCmpntLabel";
|
this.tInCmpntLabel.Name = "tInCmpntLabel";
|
||||||
this.tInCmpntLabel.Size = new System.Drawing.Size(49, 13);
|
this.tInCmpntLabel.Size = new System.Drawing.Size(49, 13);
|
||||||
this.tInCmpntLabel.TabIndex = 191;
|
this.tInCmpntLabel.TabIndex = 191;
|
||||||
@@ -658,7 +730,7 @@ namespace TBF.Screens
|
|||||||
// prOutLabel
|
// prOutLabel
|
||||||
//
|
//
|
||||||
this.prOutLabel.AutoSize = true;
|
this.prOutLabel.AutoSize = true;
|
||||||
this.prOutLabel.Location = new System.Drawing.Point(598, 140);
|
this.prOutLabel.Location = new System.Drawing.Point(598, 194);
|
||||||
this.prOutLabel.Name = "prOutLabel";
|
this.prOutLabel.Name = "prOutLabel";
|
||||||
this.prOutLabel.Size = new System.Drawing.Size(33, 13);
|
this.prOutLabel.Size = new System.Drawing.Size(33, 13);
|
||||||
this.prOutLabel.TabIndex = 189;
|
this.prOutLabel.TabIndex = 189;
|
||||||
@@ -667,7 +739,7 @@ namespace TBF.Screens
|
|||||||
// tOutLabel
|
// tOutLabel
|
||||||
//
|
//
|
||||||
this.tOutLabel.AutoSize = true;
|
this.tOutLabel.AutoSize = true;
|
||||||
this.tOutLabel.Location = new System.Drawing.Point(598, 178);
|
this.tOutLabel.Location = new System.Drawing.Point(598, 234);
|
||||||
this.tOutLabel.Name = "tOutLabel";
|
this.tOutLabel.Name = "tOutLabel";
|
||||||
this.tOutLabel.Size = new System.Drawing.Size(27, 13);
|
this.tOutLabel.Size = new System.Drawing.Size(27, 13);
|
||||||
this.tOutLabel.TabIndex = 188;
|
this.tOutLabel.TabIndex = 188;
|
||||||
@@ -676,7 +748,7 @@ namespace TBF.Screens
|
|||||||
// label17
|
// label17
|
||||||
//
|
//
|
||||||
this.label17.AutoSize = true;
|
this.label17.AutoSize = true;
|
||||||
this.label17.Location = new System.Drawing.Point(517, 140);
|
this.label17.Location = new System.Drawing.Point(517, 194);
|
||||||
this.label17.Name = "label17";
|
this.label17.Name = "label17";
|
||||||
this.label17.Size = new System.Drawing.Size(73, 13);
|
this.label17.Size = new System.Drawing.Size(73, 13);
|
||||||
this.label17.TabIndex = 187;
|
this.label17.TabIndex = 187;
|
||||||
@@ -685,7 +757,7 @@ namespace TBF.Screens
|
|||||||
// label18
|
// label18
|
||||||
//
|
//
|
||||||
this.label18.AutoSize = true;
|
this.label18.AutoSize = true;
|
||||||
this.label18.Location = new System.Drawing.Point(524, 178);
|
this.label18.Location = new System.Drawing.Point(524, 234);
|
||||||
this.label18.Name = "label18";
|
this.label18.Name = "label18";
|
||||||
this.label18.Size = new System.Drawing.Size(66, 13);
|
this.label18.Size = new System.Drawing.Size(66, 13);
|
||||||
this.label18.TabIndex = 186;
|
this.label18.TabIndex = 186;
|
||||||
@@ -694,7 +766,7 @@ namespace TBF.Screens
|
|||||||
// prInLabel
|
// prInLabel
|
||||||
//
|
//
|
||||||
this.prInLabel.AutoSize = true;
|
this.prInLabel.AutoSize = true;
|
||||||
this.prInLabel.Location = new System.Drawing.Point(141, 140);
|
this.prInLabel.Location = new System.Drawing.Point(141, 194);
|
||||||
this.prInLabel.Name = "prInLabel";
|
this.prInLabel.Name = "prInLabel";
|
||||||
this.prInLabel.Size = new System.Drawing.Size(25, 13);
|
this.prInLabel.Size = new System.Drawing.Size(25, 13);
|
||||||
this.prInLabel.TabIndex = 185;
|
this.prInLabel.TabIndex = 185;
|
||||||
@@ -703,7 +775,7 @@ namespace TBF.Screens
|
|||||||
// tInLabel
|
// tInLabel
|
||||||
//
|
//
|
||||||
this.tInLabel.AutoSize = true;
|
this.tInLabel.AutoSize = true;
|
||||||
this.tInLabel.Location = new System.Drawing.Point(141, 178);
|
this.tInLabel.Location = new System.Drawing.Point(141, 234);
|
||||||
this.tInLabel.Name = "tInLabel";
|
this.tInLabel.Name = "tInLabel";
|
||||||
this.tInLabel.Size = new System.Drawing.Size(19, 13);
|
this.tInLabel.Size = new System.Drawing.Size(19, 13);
|
||||||
this.tInLabel.TabIndex = 184;
|
this.tInLabel.TabIndex = 184;
|
||||||
@@ -712,7 +784,7 @@ namespace TBF.Screens
|
|||||||
// label14
|
// label14
|
||||||
//
|
//
|
||||||
this.label14.AutoSize = true;
|
this.label14.AutoSize = true;
|
||||||
this.label14.Location = new System.Drawing.Point(73, 140);
|
this.label14.Location = new System.Drawing.Point(73, 194);
|
||||||
this.label14.Name = "label14";
|
this.label14.Name = "label14";
|
||||||
this.label14.Size = new System.Drawing.Size(59, 13);
|
this.label14.Size = new System.Drawing.Size(59, 13);
|
||||||
this.label14.TabIndex = 183;
|
this.label14.TabIndex = 183;
|
||||||
@@ -721,7 +793,7 @@ namespace TBF.Screens
|
|||||||
// label13
|
// label13
|
||||||
//
|
//
|
||||||
this.label13.AutoSize = true;
|
this.label13.AutoSize = true;
|
||||||
this.label13.Location = new System.Drawing.Point(80, 178);
|
this.label13.Location = new System.Drawing.Point(80, 234);
|
||||||
this.label13.Name = "label13";
|
this.label13.Name = "label13";
|
||||||
this.label13.Size = new System.Drawing.Size(52, 13);
|
this.label13.Size = new System.Drawing.Size(52, 13);
|
||||||
this.label13.TabIndex = 182;
|
this.label13.TabIndex = 182;
|
||||||
@@ -737,14 +809,14 @@ namespace TBF.Screens
|
|||||||
this.metersListView.UseCompatibleStateImageBehavior = false;
|
this.metersListView.UseCompatibleStateImageBehavior = false;
|
||||||
this.metersListView.View = System.Windows.Forms.View.Details;
|
this.metersListView.View = System.Windows.Forms.View.Details;
|
||||||
//
|
//
|
||||||
// ProcessTabPageHeatMetersCtrl
|
// ProcessTabPageExCtrl
|
||||||
//
|
//
|
||||||
this.AutoScaleDimensions = new System.Drawing.SizeF(6F, 13F);
|
this.AutoScaleDimensions = new System.Drawing.SizeF(6F, 13F);
|
||||||
this.AutoScaleMode = System.Windows.Forms.AutoScaleMode.Font;
|
this.AutoScaleMode = System.Windows.Forms.AutoScaleMode.Font;
|
||||||
this.BackColor = System.Drawing.SystemColors.Control;
|
this.BackColor = System.Drawing.SystemColors.Control;
|
||||||
this.Controls.Add(this.splitContainer1);
|
this.Controls.Add(this.splitContainer1);
|
||||||
this.Font = new System.Drawing.Font("Microsoft Sans Serif", 8.25F, System.Drawing.FontStyle.Regular, System.Drawing.GraphicsUnit.Point, ((byte)(238)));
|
this.Font = new System.Drawing.Font("Microsoft Sans Serif", 8.25F, System.Drawing.FontStyle.Regular, System.Drawing.GraphicsUnit.Point, ((byte)(238)));
|
||||||
this.Name = "ProcessTabPageHeatMetersCtrl";
|
this.Name = "ProcessTabPageExCtrl";
|
||||||
this.Size = new System.Drawing.Size(1100, 800);
|
this.Size = new System.Drawing.Size(1100, 800);
|
||||||
this.Load += new System.EventHandler(this.ProcessTabPageCtrl_Load);
|
this.Load += new System.EventHandler(this.ProcessTabPageCtrl_Load);
|
||||||
this.Paint += new System.Windows.Forms.PaintEventHandler(this.ProcessTabPageCtrl_Paint);
|
this.Paint += new System.Windows.Forms.PaintEventHandler(this.ProcessTabPageCtrl_Paint);
|
||||||
@@ -828,6 +900,12 @@ namespace TBF.Screens
|
|||||||
private System.Windows.Forms.Label label14;
|
private System.Windows.Forms.Label label14;
|
||||||
private System.Windows.Forms.Label label13;
|
private System.Windows.Forms.Label label13;
|
||||||
private System.Windows.Forms.ListView metersListView;
|
private System.Windows.Forms.ListView metersListView;
|
||||||
|
private System.Windows.Forms.Label tLoCmpntLabel;
|
||||||
|
private System.Windows.Forms.Label tLoDataLabel;
|
||||||
|
private System.Windows.Forms.Label tLoLabel;
|
||||||
|
private System.Windows.Forms.Label tHiCmpntLabel;
|
||||||
|
private System.Windows.Forms.Label tHiDataLabel;
|
||||||
|
private System.Windows.Forms.Label tHiLabel;
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|||||||
@@ -46,6 +46,15 @@ namespace TBF.Screens
|
|||||||
|
|
||||||
InitializeComponent();
|
InitializeComponent();
|
||||||
|
|
||||||
|
#if HEAT_METERS
|
||||||
|
tLoLabel.Visible = true;
|
||||||
|
tLoCmpntLabel.Visible = true;
|
||||||
|
tLoDataLabel.Visible = true;
|
||||||
|
tHiLabel.Visible = true;
|
||||||
|
tHiCmpntLabel.Visible = true;
|
||||||
|
tHiDataLabel.Visible = true;
|
||||||
|
#endif
|
||||||
|
|
||||||
Bridge.ProcedureSelectedHandler += delegate(object sndr, ProcedureSelectedEventArgs args)
|
Bridge.ProcedureSelectedHandler += delegate(object sndr, ProcedureSelectedEventArgs args)
|
||||||
{
|
{
|
||||||
try
|
try
|
||||||
@@ -95,14 +104,20 @@ namespace TBF.Screens
|
|||||||
}
|
}
|
||||||
catch (Exception e) { log.ErrorFormat("ProcessTabPage24.OnProcedureCompleted() failed: {0}", e.Message); }
|
catch (Exception e) { log.ErrorFormat("ProcessTabPage24.OnProcedureCompleted() failed: {0}", e.Message); }
|
||||||
};
|
};
|
||||||
|
|
||||||
|
Timer timer = new Timer();
|
||||||
|
timer.Tick += (s, e) => { OnTimerTick(); };
|
||||||
|
timer.Interval = 5000;
|
||||||
|
timer.Start();
|
||||||
}
|
}
|
||||||
|
|
||||||
private void ProcessTabPageCtrl_Load(object sender, EventArgs e)
|
private void ProcessTabPageCtrl_Load(object sender, EventArgs e)
|
||||||
{
|
{
|
||||||
Once();
|
Once();
|
||||||
ResetLabelsAndTargetVals();
|
ResetLabelsAndTargetVals();
|
||||||
ResetReadings();
|
ResetReadings(); /// Erase all results
|
||||||
|
OnTimerTick(); /// Redraw measurements that are always available
|
||||||
|
ProcessTabPageCtrl_Paint(this, null);
|
||||||
}
|
}
|
||||||
|
|
||||||
void Once()
|
void Once()
|
||||||
@@ -124,19 +139,19 @@ namespace TBF.Screens
|
|||||||
metersListView.Items.Clear();
|
metersListView.Items.Clear();
|
||||||
metersListView.Columns.Clear();
|
metersListView.Columns.Clear();
|
||||||
|
|
||||||
metersListView.Columns.Add(Strings.Meter, 100);
|
metersListView.Columns.Add(Strings.Meter, 60);
|
||||||
metersListView.Columns.Add(Strings.Sensor, 100);
|
metersListView.Columns.Add(Strings.Sensor, 80);
|
||||||
metersListView.Columns.Add(Strings.Pulses_count, 120);
|
metersListView.Columns.Add(Strings.Pulses_count, 100);
|
||||||
metersListView.Columns.Add(Strings.Ref_pulses_count, 120);
|
metersListView.Columns.Add(Strings.Ref_pulses_count, 120);
|
||||||
metersListView.Columns.Add(Strings.Volume, 100);
|
metersListView.Columns.Add(Strings.Volume, 80);
|
||||||
metersListView.Columns.Add(Strings.Error, 100);
|
metersListView.Columns.Add(Strings.Error, 80);
|
||||||
metersListView.Columns.Add(Strings.Result, 100);
|
metersListView.Columns.Add(Strings.Result, 80);
|
||||||
///
|
///
|
||||||
if (metersKind == MetersKind.HeatMeter)
|
if (metersKind == MetersKind.HeatMeter)
|
||||||
{
|
{
|
||||||
metersListView.Columns.Add(Strings.Energy, 100);
|
metersListView.Columns.Add(Strings.Energy, 80);
|
||||||
metersListView.Columns.Add(Strings.Error, 100);
|
metersListView.Columns.Add(Strings.Error, 80);
|
||||||
metersListView.Columns.Add(Strings.Result, 100);
|
metersListView.Columns.Add(Strings.Result, 80);
|
||||||
}
|
}
|
||||||
|
|
||||||
if ((metersKind == MetersKind.Single) || (metersKind == MetersKind.HeatMeter))
|
if ((metersKind == MetersKind.Single) || (metersKind == MetersKind.HeatMeter))
|
||||||
@@ -213,6 +228,8 @@ namespace TBF.Screens
|
|||||||
tInCmpntLabel.Text = "---";
|
tInCmpntLabel.Text = "---";
|
||||||
tOutCmpntLabel.Text = "---";
|
tOutCmpntLabel.Text = "---";
|
||||||
tDivCmpntLabel.Text = "---";
|
tDivCmpntLabel.Text = "---";
|
||||||
|
tHiCmpntLabel.Text = "---";
|
||||||
|
tLoCmpntLabel.Text = "---";
|
||||||
|
|
||||||
scaleCmpntLabel.Text = "---";
|
scaleCmpntLabel.Text = "---";
|
||||||
|
|
||||||
@@ -240,10 +257,6 @@ namespace TBF.Screens
|
|||||||
void ResetReadings()
|
void ResetReadings()
|
||||||
{
|
{
|
||||||
/// Top part
|
/// Top part
|
||||||
airTempLabel.Text = "---";
|
|
||||||
airPressLabel.Text = "---";
|
|
||||||
airHumiLabel.Text = "---";
|
|
||||||
|
|
||||||
refPulsesLabel.Text = "---";
|
refPulsesLabel.Text = "---";
|
||||||
refFreqLabel.Text = "---";
|
refFreqLabel.Text = "---";
|
||||||
refFlowLabel.Text = "---";
|
refFlowLabel.Text = "---";
|
||||||
@@ -253,8 +266,12 @@ namespace TBF.Screens
|
|||||||
tDivLabel.Text = "---";
|
tDivLabel.Text = "---";
|
||||||
|
|
||||||
tInLabel.Text = "---";
|
tInLabel.Text = "---";
|
||||||
tOutLabel.Text = "---";
|
|
||||||
prInLabel.Text = "---";
|
prInLabel.Text = "---";
|
||||||
|
|
||||||
|
tHiDataLabel.Text = "---";
|
||||||
|
tLoDataLabel.Text = "---";
|
||||||
|
|
||||||
|
tOutLabel.Text = "---";
|
||||||
prOutLabel.Text = "---";
|
prOutLabel.Text = "---";
|
||||||
|
|
||||||
massLabel.Text = "---";
|
massLabel.Text = "---";
|
||||||
@@ -309,11 +326,36 @@ namespace TBF.Screens
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
|
void OnTimerTick()
|
||||||
|
{
|
||||||
|
///
|
||||||
|
/// Always available
|
||||||
|
///
|
||||||
|
airTempLabel.Text = ProcessData.AmbTemp.ToString();
|
||||||
|
airPressLabel.Text = Config.Units.ConvertTo(Config.Unit.mbar, ProcessData.AmbPress.Val).ToString("F0");
|
||||||
|
airHumiLabel.Text = ProcessData.AmbHumi.ToString();
|
||||||
|
|
||||||
|
tInLabel.Text = ProcessData.TempUp.ToString();
|
||||||
|
tOutLabel.Text = ProcessData.TempDown.ToString();
|
||||||
|
tDivLabel.Text = ProcessData.TempDiv.ToString();
|
||||||
|
|
||||||
|
prInLabel.Text = ProcessData.PressUp.ToString();
|
||||||
|
prOutLabel.Text = ProcessData.PressDown.ToString();
|
||||||
|
|
||||||
|
massLabel.Text = ProcessData.Mass.ToString();
|
||||||
|
|
||||||
|
#if HEAT_METERS
|
||||||
|
tHiDataLabel.Text = (ProcessData.TempRefHi1.Valid && ProcessData.TempRefHi2.Valid) ? ((ProcessData.TempRefHi1.Val + ProcessData.TempRefHi2.Val) / 2).ToString("F2") : "---";
|
||||||
|
tLoDataLabel.Text = (ProcessData.TempRefLo1.Valid && ProcessData.TempRefLo2.Valid) ? ((ProcessData.TempRefLo1.Val + ProcessData.TempRefLo2.Val) / 2).ToString("F2") : "---";
|
||||||
|
#endif
|
||||||
|
}
|
||||||
|
|
||||||
void OnProcedureSelected(object sender, ProcedureSelectedEventArgs args)
|
void OnProcedureSelected(object sender, ProcedureSelectedEventArgs args)
|
||||||
{
|
{
|
||||||
UpdateCurrentMetersKind(args.Procedure.MetersKind);
|
UpdateCurrentMetersKind(args.Procedure.MetersKind);
|
||||||
ResetLabelsAndTargetVals();
|
ResetLabelsAndTargetVals();
|
||||||
ResetReadings();
|
ResetReadings();
|
||||||
|
OnTimerTick(); /// Redraw measurements that are always available
|
||||||
Invalidate();
|
Invalidate();
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -330,15 +372,21 @@ namespace TBF.Screens
|
|||||||
estmtdTimeLabel.Text = args.Test.TstTime.ToString("F1");
|
estmtdTimeLabel.Text = args.Test.TstTime.ToString("F1");
|
||||||
|
|
||||||
/// Names of virtual bench components
|
/// Names of virtual bench components
|
||||||
if (args.BenchPath.PressMtrUp != null) prInCmpntLabel.Text = args.BenchPath.PressMtrUp.Name;
|
if (args.OutputPath.FlowMeter != null) refFlowCmpntLabel.Text = args.OutputPath.FlowMeter.Name;
|
||||||
|
if (args.OutputPath.RegulValve != null) regValveCmpntLabel.Text = args.OutputPath.RegulValve.Name;
|
||||||
|
if (args.OutputPath.Scale != null) scaleCmpntLabel.Text = args.OutputPath.Scale.Name;
|
||||||
|
if (args.BenchPath.PressMtrUp != null) prInCmpntLabel.Text = args.BenchPath.PressMtrUp.Name;
|
||||||
if (args.BenchPath.PressMtrDown != null) prOutCmpntLabel.Text = args.BenchPath.PressMtrDown.Name;
|
if (args.BenchPath.PressMtrDown != null) prOutCmpntLabel.Text = args.BenchPath.PressMtrDown.Name;
|
||||||
if (args.BenchPath.TempMtrUp != null) tInCmpntLabel.Text = args.BenchPath.TempMtrUp.Name;
|
if (args.BenchPath.TempMtrUp != null) tInCmpntLabel.Text = args.BenchPath.TempMtrUp.Name;
|
||||||
if (args.BenchPath.TempMtrDown != null) tOutCmpntLabel.Text = args.BenchPath.TempMtrDown.Name;
|
if (args.BenchPath.TempMtrDown != null) tOutCmpntLabel.Text = args.BenchPath.TempMtrDown.Name;
|
||||||
if (args.OutputPath.TempDiv != null) tDivCmpntLabel.Text = args.OutputPath.TempDiv.Name;
|
if (args.OutputPath.TempDiv != null) tDivCmpntLabel.Text = args.OutputPath.TempDiv.Name;
|
||||||
if (args.OutputPath.FlowMeter != null) refFlowCmpntLabel.Text = args.OutputPath.FlowMeter.Name;
|
#if HEAT_METERS
|
||||||
if (args.OutputPath.RegulValve != null) regValveCmpntLabel.Text = args.OutputPath.RegulValve.Name;
|
if (args.HeatMetersPath != null && args.HeatMetersPath.TMeterRefWarm1 != null) tHiCmpntLabel.Text = args.HeatMetersPath.TMeterRefWarm1.Name;
|
||||||
if (args.OutputPath.Scale != null) scaleCmpntLabel.Text = args.OutputPath.Scale.Name;
|
if (args.HeatMetersPath != null && args.HeatMetersPath.TMeterRefCold1 != null) tLoCmpntLabel.Text = args.HeatMetersPath.TMeterRefCold1.Name;
|
||||||
|
#endif
|
||||||
|
|
||||||
|
OnTimerTick(); /// Redraw measurements that are always available
|
||||||
|
|
||||||
if ((currentMetersKind == MetersKind.Single) || (currentMetersKind == MetersKind.HeatMeter))
|
if ((currentMetersKind == MetersKind.Single) || (currentMetersKind == MetersKind.HeatMeter))
|
||||||
{
|
{
|
||||||
for (int i = 0; i < metersListView.Items.Count; i++)
|
for (int i = 0; i < metersListView.Items.Count; i++)
|
||||||
@@ -377,17 +425,7 @@ namespace TBF.Screens
|
|||||||
|
|
||||||
void OnProcessDataChanged(object sender, ProcessDataEventArgs args)
|
void OnProcessDataChanged(object sender, ProcessDataEventArgs args)
|
||||||
{
|
{
|
||||||
///
|
/// Pressure may change faster then temperature, therefore it is updated also here
|
||||||
/// Always available
|
|
||||||
///
|
|
||||||
airTempLabel.Text = ProcessData.AmbTemp.ToString();
|
|
||||||
airPressLabel.Text = Config.Units.ConvertTo(Config.Unit.mbar, ProcessData.AmbPress.Val).ToString("F0");
|
|
||||||
airHumiLabel.Text = ProcessData.AmbHumi.ToString();
|
|
||||||
|
|
||||||
tInLabel.Text = ProcessData.TempUp.ToString();
|
|
||||||
tOutLabel.Text = ProcessData.TempDown.ToString();
|
|
||||||
tDivLabel.Text = ProcessData.TempDiv.ToString();
|
|
||||||
|
|
||||||
prInLabel.Text = ProcessData.PressUp.ToString();
|
prInLabel.Text = ProcessData.PressUp.ToString();
|
||||||
prOutLabel.Text = ProcessData.PressDown.ToString();
|
prOutLabel.Text = ProcessData.PressDown.ToString();
|
||||||
|
|
||||||
@@ -490,16 +528,9 @@ namespace TBF.Screens
|
|||||||
Results.Entities.TestRslt tRes = args.TestRslt;
|
Results.Entities.TestRslt tRes = args.TestRslt;
|
||||||
if (tRes == null) return;
|
if (tRes == null) return;
|
||||||
|
|
||||||
airTempLabel.Text = tRes.AmbTempMean.ToString("F1");
|
/// Pressure may change faster then temperature, therefore it is updated also here
|
||||||
airPressLabel.Text = Config.Units.ConvertTo(Config.Unit.mbar, tRes.AmbPressMean).ToString("F0");
|
prInLabel.Text = ProcessData.PressUp.ToString();
|
||||||
airHumiLabel.Text = tRes.AmbHumiMean.ToString("F1");
|
prOutLabel.Text = ProcessData.PressDown.ToString();
|
||||||
|
|
||||||
tInLabel.Text = tRes.TempUpMean.ToString("F2");
|
|
||||||
tOutLabel.Text = tRes.TempDownMean.ToString("F2");
|
|
||||||
tDivLabel.Text = tRes.TempDivMean.ToString("F2");
|
|
||||||
|
|
||||||
prInLabel.Text = tRes.PressUpMean.ToString("F2");
|
|
||||||
prOutLabel.Text = tRes.PressDownMean.ToString("F2");
|
|
||||||
|
|
||||||
massLabel.Text = ProcessData.Mass.ToString();
|
massLabel.Text = ProcessData.Mass.ToString();
|
||||||
massDiffLabel.Text = (tRes.MassEnd - tRes.MassStart).ToString("F3");
|
massDiffLabel.Text = (tRes.MassEnd - tRes.MassStart).ToString("F3");
|
||||||
|
|||||||
@@ -14,9 +14,10 @@ namespace TBF.UiBridge
|
|||||||
public BenchPath BenchPath;
|
public BenchPath BenchPath;
|
||||||
public OutputPath OutputPath;
|
public OutputPath OutputPath;
|
||||||
public MetersPath MetersPath;
|
public MetersPath MetersPath;
|
||||||
|
public HeatMetersPath HeatMetersPath;
|
||||||
public int TotalPulses;
|
public int TotalPulses;
|
||||||
|
|
||||||
public TestSelectedEventArgs(Config.Entities.Test test, int repetitionNr, FeedingPath f, BenchPath b, OutputPath o, MetersPath m, int tp)
|
public TestSelectedEventArgs(Config.Entities.Test test, int repetitionNr, FeedingPath f, BenchPath b, OutputPath o, MetersPath m, HeatMetersPath h, int tp)
|
||||||
{
|
{
|
||||||
Test = test;
|
Test = test;
|
||||||
RepetitionNr = repetitionNr;
|
RepetitionNr = repetitionNr;
|
||||||
@@ -24,6 +25,7 @@ namespace TBF.UiBridge
|
|||||||
BenchPath = b;
|
BenchPath = b;
|
||||||
OutputPath = o;
|
OutputPath = o;
|
||||||
MetersPath = m;
|
MetersPath = m;
|
||||||
|
HeatMetersPath = h;
|
||||||
TotalPulses = tp;
|
TotalPulses = tp;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|||||||
Reference in New Issue