(1) MettlerToledo.Multi workaround for Badger-stredna-trat at the serial protocol level, (2) VB1 display fixed, ver. 2.18.835

This commit is contained in:
Milan Hanajik
2018-03-11 12:10:53 +01:00
parent 62b06b23a5
commit 9b212bd455
4 changed files with 15 additions and 11 deletions
-4
View File
@@ -226,11 +226,7 @@ namespace TBF.BenchControl.Elde
for (int i = 0; i < MettlerToledo.Multi.BalanceDev.BalancesCount; i++)
{
#if BADGER_STREDNA_TRAT
controlCom.SetWeight(i, MettlerToledo.Multi.BalanceDev.Masses[MettlerToledo.Multi.BalanceDev.BalancesCount - 1 - i]);
#else
controlCom.SetWeight(i, MettlerToledo.Multi.BalanceDev.Masses[i]);
#endif
}
}
@@ -1,5 +1,5 @@
///
/// Copyright (c) 2015-2017 Sensus Metering Systems
/// Copyright (c) 2015-2018 Sensus Metering Systems
///
using System;
using System.Collections.Generic;
@@ -30,8 +30,8 @@ namespace TBF.BenchControl.MettlerToledo.Multi
protected readonly BalanceCfg balanceCfg;
protected static BalanceCfg balance1Cfg;
public int MultiIdNr { get { return balanceCfg.IdNr; } }
/// <summary>
/// <summary>
/// Enumeration of balances via static fields and methods
/// </summary>
static int nextBalanceIdx = 0;
@@ -48,7 +48,7 @@ namespace TBF.BenchControl.MettlerToledo.Multi
protected static SerialPort serialPort;
protected static StringBuilder stringBuilder;
public int ScaleNr { get { return balanceNr; } }
public int ScaleNr { get { return balanceNr; } }
public int IdNr { get { return balanceCfg.IdNr; } }
public double Capacity { get { return balanceCfg.Capacity; } }
public double Resolution { get { return balanceCfg.Resolution; } }
@@ -150,7 +150,11 @@ namespace TBF.BenchControl.MettlerToledo.Multi
msrmntState = (MsrmntState)((int)MsrmntState.Busy + scaleId);
stringBuilder.Clear();
#if BADGER_STREDNA_TRAT
string serialData = string.Format("AR WT0{0}01\r\n", 3 - scaleId); /// 2->1 a 1->2
#else
string serialData = string.Format("AR WT0{0}01\r\n", scaleId);
#endif
serialPort.Write(serialData);
log.InfoFormat("{0} - GetStableMassMeasurement() ... \"{1}\" sent", name, serialData);
return true;
@@ -174,8 +178,12 @@ namespace TBF.BenchControl.MettlerToledo.Multi
msrmntState = (MsrmntState)((int)MsrmntState.Busy + scaleId);
stringBuilder.Clear();
#if BADGER_STREDNA_TRAT
string serialData = string.Format("AR WT0{0}01\r\n", 3 - scaleId); /// 2->1 a 1->2
#else
string serialData = string.Format("AR WT0{0}01\r\n", scaleId);
serialPort.Write(serialData);
#endif
serialPort.Write(serialData);
log.InfoFormat("{0} - GetImmediateMassMeasurement() ... \"{1}\" sent", name, serialData);
return true;
}