Stable mass measurement rewritten, it can use immediate measurement, DB change, ver.2.5.265.
This commit is contained in:
+19
-10
@@ -23,18 +23,21 @@ namespace Config.Entities
|
||||
public virtual float Qto { get; set; } /// Water flow high limit in [m3/h]
|
||||
public virtual float Volume { get; set; } /// Test volume (target) in [l]
|
||||
public virtual float TstTime { get; set; } /// Test time (estimate) in [s]
|
||||
public virtual string Method { get; set; }
|
||||
public virtual float ErrLimLo { get; set; } /// in [%] (usually < 0)
|
||||
public virtual float ErrLimHi { get; set; } /// in [%] (usually > 0)
|
||||
public virtual float Uncertainty { get; set; } /// int [%] makes error limits tighter: 0 <= Uncertainty <= abs(ErrLimXx)
|
||||
public virtual int Repeats { get; set; }
|
||||
public virtual bool Emptying { get; set; }
|
||||
public virtual bool Zeroing { get; set; }
|
||||
public virtual float PumpPower { get; set; } /// Power of the pump in [%] in the range 0 .. 100.0f, use values 0% and 100% for non-FM pumps
|
||||
public virtual int MassRepeats { get; set; } /// Number of mass. measurements at the beginning/end of test, 0 = default (=5)
|
||||
public virtual float MassSpread { get; set; } /// Max spread of mass. measurements at the beginning/end of test, 0 = default
|
||||
public virtual bool MassMethod { get; set; } /// method of mass. measurement at the beginning/end of test: false=slow (precise), true=fast (immediate)
|
||||
public virtual int TimeBeforeFlow { get; set; } /// Delay time before the start of flow control in [s]
|
||||
public virtual int TimeFlow2Mass { get; set; } /// Delay time from the flow stable to the 1st mass measurement in [s]
|
||||
public virtual int TimePump2StartV { get; set; }/// Delay time from the start of the pump to opening the start valve in [s]
|
||||
public virtual int TimeStop2Mass { get; set; } /// Delay time from the test end (diverted) to the 2nd mass measuremen in [s]
|
||||
public virtual string Method { get; set; }
|
||||
public virtual float ErrLimLo { get; set; } /// in [%] (usually < 0)
|
||||
public virtual float ErrLimHi { get; set; } /// in [%] (usually > 0)
|
||||
public virtual float Uncertainty { get; set; } /// int [%] makes error limits tighter: 0 <= Uncertainty <= abs(ErrLimXx)
|
||||
public virtual double TolerRed { get; set; } /// = Filter
|
||||
public virtual TestRedType RedType { get; set; }
|
||||
public virtual string FeedingPath { get; set; }
|
||||
@@ -64,15 +67,18 @@ namespace Config.Entities
|
||||
Repeats = 1;
|
||||
Emptying = false;
|
||||
Zeroing = false;
|
||||
PumpPower = 60.0f; /// [%]
|
||||
TimeBeforeFlow = 10; /// [s] time before the start of flow control in [s]
|
||||
TimeFlow2Mass = 5; /// [s] time from the flow stable to the 1st mass measurement in [s]
|
||||
TimePump2StartV = 1; /// [s] time from the 1st mass measurement to the test start in [s]
|
||||
TimeStop2Mass = 5; /// [s] between the test end and the final mass measurement
|
||||
ErrLimLo = -2.0f; /// [%] lower error limit
|
||||
ErrLimHi = 2.0f; /// [%] upper error limit
|
||||
Uncertainty = 0;
|
||||
TolerRed = 0; /// = Filter parameter
|
||||
PumpPower = 60.0f; /// [%]
|
||||
MassRepeats = 0; /// default
|
||||
MassSpread = 0; /// default
|
||||
MassMethod = false; /// default
|
||||
TimeBeforeFlow = 10; /// [s] time before the start of flow control in [s]
|
||||
TimeFlow2Mass = 5; /// [s] time from the flow stable to the 1st mass measurement in [s]
|
||||
TimePump2StartV = 1; /// [s] time from the 1st mass measurement to the test start in [s]
|
||||
TimeStop2Mass = 5; /// [s] between the test end and the final mass measurement
|
||||
TolerRed = 0; /// = Filter parameter
|
||||
RelTransBefore = string.Empty;
|
||||
RelTransBetween = string.Empty;
|
||||
RelTransAfter = string.Empty;
|
||||
@@ -103,6 +109,9 @@ namespace Config.Entities
|
||||
result.Emptying = Emptying;
|
||||
result.Zeroing = Zeroing;
|
||||
result.PumpPower = PumpPower;
|
||||
result.MassRepeats = MassRepeats;
|
||||
result.MassSpread = MassSpread;
|
||||
result.MassMethod = MassMethod;
|
||||
result.TimeBeforeFlow = TimeBeforeFlow;
|
||||
result.TimeFlow2Mass = TimeFlow2Mass;
|
||||
result.TimePump2StartV = TimePump2StartV;
|
||||
|
||||
@@ -25,6 +25,9 @@ namespace Config.Mappings
|
||||
Map(x => x.Emptying);
|
||||
Map(x => x.Zeroing);
|
||||
Map(x => x.PumpPower);
|
||||
Map(x => x.MassRepeats);
|
||||
Map(x => x.MassSpread);
|
||||
Map(x => x.MassMethod);
|
||||
Map(x => x.TimeBeforeFlow);
|
||||
Map(x => x.TimeFlow2Mass);
|
||||
Map(x => x.TimePump2StartV)
|
||||
@@ -34,8 +37,9 @@ namespace Config.Mappings
|
||||
Map(x => x.ErrLimLo);
|
||||
Map(x => x.ErrLimHi);
|
||||
Map(x => x.Uncertainty);
|
||||
Map(x => x.TolerRed); /// ???
|
||||
Map(x => x.RedType); /// ???
|
||||
Map(x => x.TolerRed)
|
||||
.Column("TolerRed"); /// ???
|
||||
Map(x => x.RedType); /// ???
|
||||
Map(x => x.FeedingPath);
|
||||
Map(x => x.BenchPath);
|
||||
Map(x => x.OutputPath);
|
||||
|
||||
@@ -32,5 +32,5 @@ using System.Runtime.InteropServices;
|
||||
// You can specify all the values or you can default the Build and Revision Numbers
|
||||
// by using the '*' as shown below:
|
||||
// [assembly: AssemblyVersion("1.0.*")]
|
||||
[assembly: AssemblyVersion("2.5.251.0")]
|
||||
[assembly: AssemblyFileVersion("2.5.251.0")]
|
||||
[assembly: AssemblyVersion("2.5.265.0")]
|
||||
[assembly: AssemblyFileVersion("2.5.265.0")]
|
||||
|
||||
Reference in New Issue