Refactorization: TBF.UI namespace, no change of function, ver. 2.18.1314
This commit is contained in:
@@ -0,0 +1,657 @@
|
||||
using System;
|
||||
using System.Drawing;
|
||||
using System.Windows.Forms;
|
||||
using System.Collections.Generic;
|
||||
using log4net;
|
||||
using MySql.Data.MySqlClient;
|
||||
using NHibernate;
|
||||
using Results;
|
||||
using Results.Entities;
|
||||
using TBF.Resources;
|
||||
|
||||
namespace TBF.UI.Settings
|
||||
{
|
||||
public partial class UpgradeSelectionDlg : Form
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(UpgradeSelectionDlg));
|
||||
|
||||
int batchFrom;
|
||||
int batchTo;
|
||||
|
||||
Shared.ModelessActivityForm form;
|
||||
System.Threading.Thread formThread;
|
||||
|
||||
public UpgradeSelectionDlg()
|
||||
{
|
||||
InitializeComponent();
|
||||
|
||||
upgradeConfigDBCheckBox.Checked = true;
|
||||
upgradeResultsDBCheckBox.Checked = true;
|
||||
|
||||
batchFrom = 1;
|
||||
batchTo = Program.LocalSettings.BatchNr - 1;
|
||||
|
||||
textBox1.Text = batchFrom.ToString();
|
||||
textBox2.Text = batchTo.ToString();
|
||||
}
|
||||
|
||||
void ActivityStart()
|
||||
{
|
||||
form = new Shared.ModelessActivityForm()
|
||||
{
|
||||
Message = "Upgrading database",
|
||||
FontFamily = "Arial",
|
||||
FontSize = 24,
|
||||
FontStyle = FontStyle.Regular,
|
||||
BackgroundColor = Color.Green,
|
||||
};
|
||||
formThread = new System.Threading.Thread(() => form.ShowDialog());
|
||||
formThread.Start();
|
||||
}
|
||||
|
||||
void ActivityEnd()
|
||||
{
|
||||
if (form != null && formThread != null)
|
||||
{
|
||||
form.CloseForm(null, new EventArgs());
|
||||
formThread.Join();
|
||||
}
|
||||
form = null;
|
||||
formThread = null;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Common part of database upgrade code
|
||||
/// </summary>
|
||||
/// <param name="dbConn">Database connection</param>
|
||||
/// <param name="commands">Array of SQL commands to be executed</param>
|
||||
/// <returns>true = successful</returns>
|
||||
bool ExecuteCommands(MySqlConnection dbConn, string[] commands)
|
||||
{
|
||||
bool success = false;
|
||||
|
||||
try
|
||||
{
|
||||
dbConn.Open();
|
||||
|
||||
foreach (var cmdText in commands)
|
||||
{
|
||||
MySqlCommand cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = cmdText;
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
}
|
||||
|
||||
success = true;
|
||||
}
|
||||
catch (Exception exc)
|
||||
{
|
||||
log.ErrorFormat(string.Format("Exception when upgrading DB: {0}", exc.Message));
|
||||
if (exc.InnerException != null) log.ErrorFormat(string.Format("Inner exception: {0}", exc.InnerException.Message));
|
||||
ActivityEnd();
|
||||
MessageBox.Show(string.Format("Exception {0}", exc.Message), "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
|
||||
}
|
||||
finally
|
||||
{
|
||||
dbConn.Close();
|
||||
}
|
||||
|
||||
return success;
|
||||
}
|
||||
|
||||
///---------------------------------------------------------------------
|
||||
private void upgradeDb_NFC_button_Click(object sender, EventArgs e)
|
||||
{
|
||||
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
|
||||
{
|
||||
MessageBox.Show("No database selected");
|
||||
return;
|
||||
}
|
||||
|
||||
string[] commands = new string[]
|
||||
{
|
||||
"ALTER TABLE `user` ADD `Tag` VARCHAR(255) NULL DEFAULT NULL AFTER `Number`;",
|
||||
};
|
||||
|
||||
ActivityStart();
|
||||
|
||||
if (!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Config.Data.CurrentBench.ProceduresDBSettings.ConnectionString), commands))
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_NFC_button.Enabled = false;
|
||||
}
|
||||
}
|
||||
|
||||
///---------------------------------------------------------------------
|
||||
private void upgradeDb_24_29_Button_Click(object sender, EventArgs e)
|
||||
{
|
||||
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
|
||||
{
|
||||
MessageBox.Show("No database selected");
|
||||
return;
|
||||
}
|
||||
|
||||
string[] configDbCommands = new string[]
|
||||
{
|
||||
/// 2.4 -> 2.5
|
||||
"ALTER TABLE `test` ADD `MassRepeats` INT NOT NULL DEFAULT '5' AFTER `PumpPower`, ADD `MassSpread` FLOAT NOT NULL DEFAULT '0' AFTER `MassRepeats`, ADD `MassMethod` TINYINT(3) UNSIGNED NOT NULL DEFAULT '0' AFTER `MassSpread`",
|
||||
|
||||
/// 2.5 -> 2.6 ---
|
||||
/// 2.6 -> 2.7 ---
|
||||
/// 2.7 -> 2.8 ---
|
||||
|
||||
/// 2.8 -> 2.9
|
||||
"ALTER TABLE `meterspath` DROP `Qfrom`, DROP `Qto`;",
|
||||
};
|
||||
|
||||
string[] resultsDbCommands = new string[]
|
||||
{
|
||||
/// 2.4 -> 2.5 ---
|
||||
|
||||
/// 2.5 -> 2.6
|
||||
"ALTER TABLE `watermeterdata` DROP `Q3`, CHANGE `Qn` `Q3_Qn` DOUBLE NULL DEFAULT NULL ",
|
||||
"ALTER TABLE `watermeterdata` ADD `DN` DOUBLE NOT NULL DEFAULT '0' AFTER `Producer`, ADD `L` DOUBLE NOT NULL DEFAULT '0' AFTER `DN`, ADD `Mounting` VARCHAR(255) NULL DEFAULT NULL AFTER `L`, ADD `TemperatureClass` VARCHAR(255) NULL DEFAULT NULL AFTER `Q1_Qmin`, ADD `PressureLossClass` VARCHAR(255) NULL DEFAULT NULL AFTER `TemperatureClass`",
|
||||
"ALTER TABLE `watermeterdata` ADD `MaxAdmissiblePressure` VARCHAR(255) NULL DEFAULT NULL AFTER `PressureLossClass`, ADD `FlowProfileSensitivityClass` VARCHAR(255) NULL DEFAULT NULL AFTER `MaxAdmissiblePressure`, ADD `Certificate` VARCHAR(255) NULL DEFAULT NULL AFTER `FlowProfileSensitivityClass`, ADD `PulsesPerLtr` DOUBLE NOT NULL DEFAULT '1' AFTER `Certificate`",
|
||||
"ALTER TABLE `watermeterdata` ADD `Text1` VARCHAR(255) NULL DEFAULT NULL AFTER `PulsesPerLtr`, ADD `Text2` VARCHAR(255) NULL DEFAULT NULL AFTER `Text1`, ADD `Text3` VARCHAR(255) NULL DEFAULT NULL AFTER `Text2`, ADD `Text4` VARCHAR(255) NULL DEFAULT NULL AFTER `Text3`, ADD `Text5` VARCHAR(255) NULL DEFAULT NULL AFTER `Text4`",
|
||||
/// 2.6 -> 2.7
|
||||
"ALTER TABLE `watermeterdata` ADD `ProducerAux` VARCHAR(255) NULL DEFAULT NULL AFTER `PulsesPerLtr`, ADD `Q3_Qn_Aux` DOUBLE NOT NULL DEFAULT '0' AFTER `ProducerAux`, ADD `MetrologicalClassAux` VARCHAR(255) NULL DEFAULT NULL AFTER `Q3_Qn_Aux`, ADD `ApprovalInfoAux` VARCHAR(255) NULL DEFAULT NULL AFTER `MetrologicalClassAux`",
|
||||
/// 2.7 -> 2.8
|
||||
"ALTER TABLE `watermeter` ADD `ResultCode` INT NOT NULL DEFAULT '0' AFTER `Passed`",
|
||||
"ALTER TABLE `batch` ADD `Remark` VARCHAR( 2000 ) NULL DEFAULT NULL AFTER `ProtocolTitle`",
|
||||
|
||||
/// 2.8 -> 2.9 ---
|
||||
};
|
||||
|
||||
ActivityStart();
|
||||
|
||||
if ((!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Config.Data.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
|
||||
(!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(DB.ConnectionString), resultsDbCommands)))
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_24_29_Button.Enabled = false;
|
||||
}
|
||||
}
|
||||
|
||||
///---------------------------------------------------------------------
|
||||
private void upgradeDb_29_212_Button_Click(object sender, EventArgs e)
|
||||
{
|
||||
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
|
||||
{
|
||||
MessageBox.Show("No database selected");
|
||||
return;
|
||||
}
|
||||
|
||||
string[] configDbCommands = new string[]
|
||||
{
|
||||
/// 2.9 -> 2.10
|
||||
|
||||
/// 2.10 -> 2.11
|
||||
"ALTER TABLE `feedingpath` ADD `RegulValvesPct` VARCHAR(255) NULL DEFAULT NULL AFTER `Pump;",
|
||||
|
||||
/// 2.11 -> 2.12
|
||||
"ALTER TABLE `benchpath` ADD `PressMtrDelta` VARCHAR(255) NULL DEFAULT NULL AFTER `PressOut;",
|
||||
};
|
||||
|
||||
string[] resultsDbCommands = new string[]
|
||||
{
|
||||
/// 2.9 -> 2.10
|
||||
"ALTER TABLE `testrslt` ADD `AmbTempStart` FLOAT NOT NULL DEFAULT '0' AFTER `AmbientTempAve`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbTempEnd` FLOAT NOT NULL DEFAULT '0' AFTER `AmbTempStart`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbTempMin` FLOAT NOT NULL DEFAULT '0' AFTER `AmbTempEnd`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbTempMax` FLOAT NOT NULL DEFAULT '0' AFTER `AmbTempMin`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbPressStart` FLOAT NOT NULL DEFAULT '0' AFTER `AmbientPressAve`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbPressEnd` FLOAT NOT NULL DEFAULT '0' AFTER `AmbPressStart`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbPressMin` FLOAT NOT NULL DEFAULT '0' AFTER `AmbPressEnd`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbPressMax` FLOAT NOT NULL DEFAULT '0' AFTER `AmbPressMin`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbHumiStart` FLOAT NOT NULL DEFAULT '0' AFTER `AmbientHumiAve`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbHumiEnd` FLOAT NOT NULL DEFAULT '0' AFTER `AmbHumiStart`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbHumiMin` FLOAT NOT NULL DEFAULT '0' AFTER `AmbHumiEnd`",
|
||||
"ALTER TABLE `testrslt` ADD `AmbHumiMax` FLOAT NOT NULL DEFAULT '0' AFTER `AmbHumiMin`",
|
||||
|
||||
/// 2.10 -> 2.11
|
||||
|
||||
/// 2.11 -> 2.12
|
||||
"ALTER TABLE `testrslt` ADD `PressDeltaMean` FLOAT NOT NULL DEFAULT '0' AFTER `PressDownMax`",
|
||||
"ALTER TABLE `testrslt` ADD `PressDeltaStart` FLOAT NOT NULL DEFAULT '0' AFTER `PressDeltaMean`",
|
||||
"ALTER TABLE `testrslt` ADD `PressDeltaEnd` FLOAT NOT NULL DEFAULT '0' AFTER `PressDeltaStart`",
|
||||
"ALTER TABLE `testrslt` ADD `PressDeltaMin` FLOAT NOT NULL DEFAULT '0' AFTER `PressDeltaEnd`",
|
||||
"ALTER TABLE `testrslt` ADD `PressDeltaMax` FLOAT NOT NULL DEFAULT '0' AFTER `PressDeltaMin`",
|
||||
"ALTER TABLE `testrslt` ADD `FlowStart` FLOAT NOT NULL DEFAULT '0' AFTER `TempDivMax`",
|
||||
"ALTER TABLE `testrslt` ADD `FlowEnd` FLOAT NOT NULL DEFAULT '0' AFTER `FlowStart`",
|
||||
};
|
||||
|
||||
ActivityStart();
|
||||
|
||||
if ((!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Config.Data.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
|
||||
(!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(DB.ConnectionString), resultsDbCommands)))
|
||||
{
|
||||
if (upgradeConfigDBCheckBox.Checked)
|
||||
{
|
||||
MySqlConnection dbConn = new MySqlConnection(Config.Data.CurrentBench.ProceduresDBSettings.ConnectionString);
|
||||
try
|
||||
{
|
||||
dbConn.Open();
|
||||
|
||||
MySqlCommand cmd;
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.Adjustment.Single' WHERE ClassName = 'Adjustment'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FlyingStartMassCollection.Compound' WHERE ClassName = 'CombinedMeters'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.CombinedWithDetection.Compound' WHERE ClassName = 'CombinedWithDetection'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FixedStartMassCollection.Single' WHERE ClassName = 'FixedStartMassCollection'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FixedStartMassCollection.Compound' WHERE ClassName = 'FixedStartCombinedMeters'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FlyingStart.Single' WHERE ClassName = 'FlyingStart'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.FlyingStartMassCollection.Single' WHERE ClassName = 'Flying-Start-Collection'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.LeakTest' WHERE ClassName = 'Leak-Test'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.PMaxTest' WHERE ClassName = 'PMax-Test'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'Output.Printers.Enhanced.Single' WHERE ClassName = 'BasicResultsPrinter'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_29_212_Button.Enabled = false;
|
||||
}
|
||||
catch (Exception exc)
|
||||
{
|
||||
log.ErrorFormat(string.Format("Exception when upgrading DB: {0}", exc.Message));
|
||||
if (exc.InnerException != null) log.ErrorFormat(string.Format("Inner exception: {0}", exc.InnerException.Message));
|
||||
ActivityEnd();
|
||||
MessageBox.Show(string.Format("Exception {0}", exc.Message), "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
|
||||
}
|
||||
finally
|
||||
{
|
||||
dbConn.Close();
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_29_212_Button.Enabled = false;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
///---------------------------------------------------------------------
|
||||
private void upgradeDb_212_215_Button_Click(object sender, EventArgs e)
|
||||
{
|
||||
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
|
||||
{
|
||||
MessageBox.Show("No database selected");
|
||||
return;
|
||||
}
|
||||
|
||||
string[] configDbCommands = new string[]
|
||||
{
|
||||
/// 2.12 -> 2.13
|
||||
"ALTER TABLE `procedure` ADD `Protected` BOOLEAN NOT NULL DEFAULT '0' AFTER `ProtocolTitle`, ADD `MustBeComplete` BOOLEAN NOT NULL DEFAULT '0' AFTER `Protected`, ADD `ManualCtrlDisabled` BOOLEAN NOT NULL DEFAULT '0' AFTER `MustBeComplete`",
|
||||
/// 2.13 -> 2.14
|
||||
"ALTER TABLE `test` ADD `DoControlWaterTemp` BOOLEAN NOT NULL DEFAULT '0' AFTER `Zeroing`, ADD `TempLimLo` FLOAT NOT NULL DEFAULT '15' AFTER `DoControlWaterTemp`, ADD `TempLimHi` FLOAT NOT NULL DEFAULT '25' AFTER `TempLimLo`",
|
||||
/// 2.14 -> 2.15
|
||||
"ALTER TABLE `procedure` ADD `AltProcName` VARCHAR(255) NULL DEFAULT NULL , ADD `AltProcPeriod` INT NOT NULL DEFAULT '0';",
|
||||
//"ALTER TABLE `procedure` DROP `ProtocolTitle`;", /// Commented out to maintain compatibility with an old ResultsBrowser
|
||||
};
|
||||
|
||||
string[] resultsDbCommands = new string[]
|
||||
{
|
||||
/// 2.12 -> 2.13
|
||||
"ALTER TABLE `watermeter` ADD `Remark` VARCHAR( 2000 ) NULL DEFAULT NULL AFTER `ResultCode`",
|
||||
"ALTER TABLE `batch` ADD `Dirty` BOOLEAN NOT NULL DEFAULT '0' AFTER `EndTime`",
|
||||
/// 2.13 -> 2.14
|
||||
#if !IPERL
|
||||
"ALTER TABLE `testrslt` ADD `FlowMean` FLOAT NOT NULL DEFAULT '0' AFTER `TempDivMax`",
|
||||
#endif
|
||||
"ALTER TABLE `testrslt` ADD `TestDone` BOOLEAN NOT NULL DEFAULT '1' AFTER `RepetitionNr`, ADD `Remark` VARCHAR( 2000 ) NULL DEFAULT NULL AFTER `TestDone`",
|
||||
"ALTER TABLE `testdata` ADD `DoControlWaterTemp` BOOLEAN NOT NULL DEFAULT '0' AFTER `Uncertainty`, ADD `TempLimLo` FLOAT NOT NULL DEFAULT '15' AFTER `DoControlWaterTemp`, ADD `TempLimHi` FLOAT NOT NULL DEFAULT '25' AFTER `TempLimLo`",
|
||||
/// 2.14 -> 2.15
|
||||
"ALTER TABLE `watermeter` ADD `ArchivePath` VARCHAR(255) NULL DEFAULT NULL AFTER `ResultCode`;",
|
||||
};
|
||||
|
||||
ActivityStart();
|
||||
|
||||
if ((!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Config.Data.CurrentBench.ProceduresDBSettings.ConnectionString), configDbCommands)) &&
|
||||
(!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(DB.ConnectionString), resultsDbCommands)))
|
||||
{
|
||||
if (upgradeConfigDBCheckBox.Checked)
|
||||
{
|
||||
MySqlConnection dbConn = new MySqlConnection(Config.Data.CurrentBench.ProceduresDBSettings.ConnectionString);
|
||||
try
|
||||
{
|
||||
dbConn.Open();
|
||||
|
||||
int maxItemNr = 0;
|
||||
MySqlCommand cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "SELECT ItemNr FROM component";
|
||||
MySqlDataReader dr = cmd.ExecuteReader();
|
||||
while (dr.Read())
|
||||
{
|
||||
int itemNr = dr.GetInt32(0);
|
||||
if (itemNr > maxItemNr) maxItemNr = itemNr;
|
||||
}
|
||||
dr.Close();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'RegisterReader for standing start/stop' WHERE ClassName = 'Fixed-Start-Register-Reader'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'TestMethods.iPerlCommunication' WHERE ClassName = 'iPerlCommunication'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET ClassName = 'WaterMeter' WHERE ClassName = 'iPerl'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
for (int i = 1; i <= 40; i++)
|
||||
{
|
||||
Text = string.Format("Upgrade selection: {0}/40", i);
|
||||
|
||||
/// Read original iPerl water meter parameters
|
||||
int id = 0;
|
||||
string parameters = string.Empty;
|
||||
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = string.Format("SELECT Id, Parameters FROM Component WHERE Name = 'iPerl{0}' AND ClassName = 'WaterMeter'", i);
|
||||
dr = cmd.ExecuteReader();
|
||||
if (dr.Read())
|
||||
{
|
||||
id = dr.GetInt32(0);
|
||||
parameters = dr.GetString(1);
|
||||
}
|
||||
dr.Close();
|
||||
cmd.Dispose();
|
||||
|
||||
if (id != 0)
|
||||
{
|
||||
/// Rename iPerl water meter
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = string.Format("UPDATE component SET Name = 'WM{0}' WHERE Name = 'iPerl{0}'", i);
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
/// Create iPerl Head
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = string.Format("INSERT INTO component(ItemNr, Name, ClassName, Parentname, Mode, Logging, Parameters) VALUES ({0}, 'iPerl{1}', 'RegisterReader for iPerl', '', 'Normal', 'Off', @params)",
|
||||
maxItemNr + 1, i);
|
||||
cmd.Parameters.AddWithValue("@params", parameters.Replace("WaterMeterCfg", "IperlHeadCfg"));
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
/// Clone procedure parameters
|
||||
IList<int> idList = new List<int>();
|
||||
IList<string> parList = new List<string>();
|
||||
IList<int> procIdList = new List<int>();
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = string.Format("SELECT Id, Parameters, Procedure_id FROM componentprocedure WHERE CmpntName = 'iPerl{0}'", i);
|
||||
dr = cmd.ExecuteReader();
|
||||
while (dr.Read())
|
||||
{
|
||||
idList.Add(dr.GetInt32(0));
|
||||
parList.Add(dr.GetString(1));
|
||||
procIdList.Add(dr.GetInt32(2));
|
||||
}
|
||||
dr.Close();
|
||||
cmd.Dispose();
|
||||
|
||||
if ((idList.Count == parList.Count) && (parList.Count == procIdList.Count))
|
||||
{
|
||||
for (int j = 0; j < parList.Count; j++)
|
||||
{
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = string.Format("INSERT INTO componentprocedure(CmpntName, Parameters, Procedure_id) VALUES ('WM{0}', @params, {1})",
|
||||
i, procIdList[j]);
|
||||
cmd.Parameters.AddWithValue("@params", parList[j].Replace("Q4", "Qmax")
|
||||
.Replace("Q3", "Qn")
|
||||
.Replace("Q2", "Qt")
|
||||
.Replace("Q1", "Qmin")
|
||||
.Replace("<Qmax>", "<NewQnames>true</NewQnames>\r\n <Qmax>"));
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// Delete 'Parmeters' of iPerl water meters
|
||||
cmd = dbConn.CreateCommand();
|
||||
cmd.CommandText = "UPDATE component SET Parameters = '<?xml version=\"1.0\" encoding=\"utf-16\"?>\r\n<WaterMeterCfg xmlns:xsi=\"http://www.w3.org/2001/XMLSchema-instance\" xmlns:xsd=\"http://www.w3.org/2001/XMLSchema\">\r\n</WaterMeterCfg>' WHERE ClassName = 'WaterMeter'";
|
||||
cmd.ExecuteNonQuery();
|
||||
cmd.Dispose();
|
||||
|
||||
Text = string.Format("Upgrade selection");
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_212_215_Button.Enabled = false;
|
||||
}
|
||||
catch (Exception exc)
|
||||
{
|
||||
log.ErrorFormat(string.Format("Exception when upgrading DB: {0}", exc.Message));
|
||||
if (exc.InnerException != null) log.ErrorFormat(string.Format("Inner exception: {0}", exc.InnerException.Message));
|
||||
ActivityEnd();
|
||||
MessageBox.Show(string.Format("Exception {0}", exc.Message), "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
|
||||
}
|
||||
finally
|
||||
{
|
||||
dbConn.Close();
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_212_215_Button.Enabled = false;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
///---------------------------------------------------------------------
|
||||
private void upgradeDb_215_216_Button_Click(object sender, EventArgs e)
|
||||
{
|
||||
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
|
||||
{
|
||||
MessageBox.Show("No database selected");
|
||||
return;
|
||||
}
|
||||
|
||||
string[] commands = new string[]
|
||||
{
|
||||
"ALTER TABLE `testrslt` ADD `ErrorFlagsMd` TINYINT( 4 ) NOT NULL DEFAULT '0' AFTER `ErrorMaster`, ADD `ErrorFlags` INT NOT NULL DEFAULT '0' AFTER `ErrorFlagsMd`;",
|
||||
};
|
||||
|
||||
ActivityStart();
|
||||
|
||||
if (!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(DB.ConnectionString), commands))
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_215_216_Button.Enabled = false;
|
||||
}
|
||||
}
|
||||
|
||||
///---------------------------------------------------------------------
|
||||
private void upgradeDb_216_217_Button_Click(object sender, EventArgs e)
|
||||
{
|
||||
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
|
||||
{
|
||||
MessageBox.Show("No database selected");
|
||||
return;
|
||||
}
|
||||
|
||||
string[] commands = new string[]
|
||||
{
|
||||
"ALTER TABLE `testrslt` ADD `DiverterStart` FLOAT NOT NULL DEFAULT '0.001' AFTER `ErrorMaster`, ADD `DiverterEnd` FLOAT NOT NULL DEFAULT '0.001' AFTER `DiverterStart`;",
|
||||
"ALTER TABLE `watermeter` ADD `ErrorFlags` INT NOT NULL DEFAULT '0' AFTER `QFall`;",
|
||||
};
|
||||
|
||||
ActivityStart();
|
||||
|
||||
if (!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(DB.ConnectionString), commands))
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_216_217_Button.Enabled = false;
|
||||
}
|
||||
}
|
||||
|
||||
///---------------------------------------------------------------------
|
||||
private void upgradeDb_217_218_Button_Click(object sender, EventArgs e)
|
||||
{
|
||||
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
|
||||
{
|
||||
MessageBox.Show("No database selected");
|
||||
return;
|
||||
}
|
||||
|
||||
string[] commands = new string[]
|
||||
{
|
||||
"ALTER TABLE `measurementcorrection` ADD `RangeIx` INT NOT NULL DEFAULT '0' AFTER `Id`;",
|
||||
};
|
||||
|
||||
ActivityStart();
|
||||
|
||||
if (!upgradeConfigDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(Config.Data.CurrentBench.ProceduresDBSettings.ConnectionString), commands))
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_217_218_Button.Enabled = false;
|
||||
}
|
||||
}
|
||||
|
||||
///---------------------------------------------------------------------
|
||||
private void upgradeDb_218_220_Button_Click(object sender, EventArgs e)
|
||||
{
|
||||
if (!upgradeConfigDBCheckBox.Checked && !upgradeResultsDBCheckBox.Checked)
|
||||
{
|
||||
MessageBox.Show("No database selected");
|
||||
return;
|
||||
}
|
||||
|
||||
string[] commands = new string[]
|
||||
{
|
||||
"ALTER TABLE `metertestrslt` ADD `RegReaderType` INT NOT NULL DEFAULT '0' AFTER `CompoundMeterId`;",
|
||||
"ALTER TABLE `testrslt` ADD `MethodClass` VARCHAR(255) NULL DEFAULT NULL AFTER `RepetitionNr`, ADD `ConstMasterRaw` DOUBLE NOT NULL DEFAULT '1' AFTER `PulsesMaster`, ADD `ConstMasterCorr` DOUBLE NOT NULL DEFAULT '1' AFTER `ConstMasterRaw`;",
|
||||
"ALTER TABLE `watermeterdata` ADD `Medium` VARCHAR(255) NULL DEFAULT NULL AFTER `ApprovalInfoAux`;",
|
||||
};
|
||||
|
||||
ActivityStart();
|
||||
|
||||
if (!upgradeResultsDBCheckBox.Checked || ExecuteCommands(new MySqlConnection(DB.ConnectionString), commands))
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show("DB succesfully upgraded", "Confirmation", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
upgradeDb_218_220_Button.Enabled = false;
|
||||
}
|
||||
}
|
||||
|
||||
private void pressureRepresentationButton_Click(object sender, EventArgs e)
|
||||
{
|
||||
try
|
||||
{
|
||||
batchFrom = int.Parse(textBox1.Text);
|
||||
batchTo = int.Parse(textBox2.Text);
|
||||
if (batchFrom < 1 || batchFrom > batchTo) throw new Exception();
|
||||
}
|
||||
catch
|
||||
{
|
||||
MessageBox.Show("Wrong 'From batch #' or 'To batch #'", "Error", MessageBoxButtons.OK, MessageBoxIcon.Exclamation);
|
||||
return;
|
||||
}
|
||||
|
||||
if (MessageBox.Show("Are you sure ?", "", MessageBoxButtons.YesNo, MessageBoxIcon.Question) == DialogResult.No) return;
|
||||
|
||||
ActivityStart();
|
||||
|
||||
try
|
||||
{
|
||||
ISession session = DB.CreateSession();
|
||||
|
||||
IList<Batch> bFrom = session.QueryOver<Batch>().Where(x => (x.BatchNr == batchFrom)).List<Batch>();
|
||||
IList<Batch> bTo = session.QueryOver<Batch>().Where(x => (x.BatchNr == batchTo)).List<Batch>();
|
||||
|
||||
if (bFrom.Count != 1) throw new Exception("No start batch");
|
||||
if (bTo.Count != 1) throw new Exception("No end batch");
|
||||
|
||||
IList<TestRslt> testResults = session.QueryOver<TestRslt>()
|
||||
.WhereRestrictionOn(x => x.StartTime)
|
||||
.IsBetween(bFrom[0].StartTime)
|
||||
.And(bTo[0].EndTime)
|
||||
.List<TestRslt>();
|
||||
|
||||
foreach (var tr in testResults)
|
||||
{
|
||||
Text = string.Format("Batch # = {0}", tr.Batch.BatchNr);
|
||||
|
||||
float factor1 = 0.01f;
|
||||
|
||||
tr.PressUpMean *= factor1;
|
||||
tr.PressUpStart *= factor1;
|
||||
tr.PressUpEnd *= factor1;
|
||||
tr.PressUpMin *= factor1;
|
||||
tr.PressUpMax *= factor1;
|
||||
|
||||
tr.PressDownMean *= factor1;
|
||||
tr.PressDownStart *= factor1;
|
||||
tr.PressDownEnd *= factor1;
|
||||
tr.PressDownMin *= factor1;
|
||||
tr.PressDownMax *= factor1;
|
||||
|
||||
tr.AmbPressMean *= 0.001f;
|
||||
|
||||
session.SaveOrUpdate(tr);
|
||||
}
|
||||
|
||||
session.Flush();
|
||||
ActivityEnd();
|
||||
MessageBox.Show("Upgrade completed", "", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
}
|
||||
catch (Exception exc)
|
||||
{
|
||||
ActivityEnd();
|
||||
MessageBox.Show(string.Format("Upgrade failed:\r\n{0}", exc.Message),
|
||||
"Error", MessageBoxButtons.OK, MessageBoxIcon.Information);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user