Modbus logging with child component names, ver. 3.1.1606
This commit is contained in:
@@ -17,7 +17,8 @@ namespace TBF.Rig.Modbus.WaterAnalyzer
|
||||
public override string ToString() { return string.Format("{0}({1})", ClassName, Cfg.ToString(-1)); }
|
||||
|
||||
readonly AnalyzerCfg myCfg;
|
||||
readonly Common.Modbus modbus;
|
||||
|
||||
Common.Modbus modbus;
|
||||
|
||||
///
|
||||
/// Measured values when MsrmntState == MsrmntState.Valid
|
||||
@@ -39,28 +40,21 @@ namespace TBF.Rig.Modbus.WaterAnalyzer
|
||||
: base(cfg)
|
||||
{
|
||||
myCfg = cfg as AnalyzerCfg;
|
||||
|
||||
modbus = TbfComponents.FindComponent(cfg.ParentName, components) as Common.Modbus;
|
||||
if (modbus == null) throw new Exception("Cannot find " + Name + " parent");
|
||||
|
||||
log.Warn(this.ToString());
|
||||
}
|
||||
|
||||
/// <summary>Initialize this device</summary>
|
||||
public override void Initialize()
|
||||
{
|
||||
if (myCfg.DebugLevel == DebugMode.Simulate)
|
||||
{
|
||||
conductivity = 0.0F;
|
||||
temperature = 0.0;
|
||||
modbus = TbfComponents.FindComponent(myCfg.ParentName) as Common.Modbus;
|
||||
if (modbus == null) throw new Exception("Cannot find " + Name + " parent");
|
||||
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
return;
|
||||
}
|
||||
conductivity = 0.0F;
|
||||
temperature = 0.0;
|
||||
msrmntTimeStamp = 0;
|
||||
|
||||
modbus.ComponentNames[myCfg.ModbusAddress] = Name;
|
||||
ticketNumber = modbus.RegisterForPolling();
|
||||
|
||||
log.FatalFormat("Successfully initialized device {0}", ToString());
|
||||
log.FatalFormat("{0} initialized: {1}", Name, this);
|
||||
}
|
||||
|
||||
|
||||
@@ -123,7 +117,7 @@ namespace TBF.Rig.Modbus.WaterAnalyzer
|
||||
msg[4] = (byte)(count >> 8); /// Serial Com Reference Hi
|
||||
msg[5] = (byte)(count & 0xFF); /// Serial Com Reference Lo
|
||||
|
||||
modbus.SendMessage(msg);
|
||||
modbus.SendMessage(msg, Name);
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
Reference in New Issue