- many process tab page improvements
- program start and state changes logging improved - IDC100 measurement related changes: reference pulses in RegisterReader - etc
This commit is contained in:
+5
-5
@@ -37,7 +37,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
||||
/// float timeHr = volumeLtr / (1000.0f * targetFlow);
|
||||
/// float timeSec = 3600.0f * timeHr;
|
||||
/// int refPulses = (int)(timeSec * (2000.0f * targetFlow / pOut.FlowMeter.NominalFlow));
|
||||
int totalPulses = (int)(test.Volume / ltrPerRefPulse);
|
||||
int totalPulses = (int)(test.Volume / ltrPerRefPulse + 0.5f);
|
||||
|
||||
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this);
|
||||
|
||||
@@ -111,7 +111,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
||||
|
||||
int flowSetTime = StateMachine.Time - flowSetTime0;
|
||||
float progress = Formulas.TestProgress(flowSetTime, estFlowSetTime, test.TstTime);
|
||||
Bridge.OnTestProgress(this, GetTestProgressData(test, tstRslt, cBrd, flowSetTime, progress));
|
||||
Bridge.OnTestProgress(this, GetTestProgressData(test, tstRslt, false, cBrd, flowSetTime, progress));
|
||||
|
||||
if (e.Contains(Event.UiCmdStop)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
@@ -128,7 +128,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
||||
|
||||
int flowSetTime = StateMachine.Time - flowSetTime0;
|
||||
float progress = Formulas.TestProgress(flowSetTime, estFlowSetTime, test.TstTime);
|
||||
Bridge.OnTestProgress(this, GetTestProgressData(test, tstRslt, cBrd, flowSetTime, progress));
|
||||
Bridge.OnTestProgress(this, GetTestProgressData(test, tstRslt, false, cBrd, flowSetTime, progress));
|
||||
|
||||
if (e.Contains(Event.OpArgumentError)) { retVal = Event.OpArgumentError; goto stopTest; }
|
||||
if (e.Contains(Event.UiCmdStop)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
@@ -253,7 +253,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
||||
|
||||
|
||||
float progress = Formulas.TestProgress(cBrd.EtPulses(0), totalPulses, estFlowSetTime, test.TstTime);
|
||||
Bridge.OnTestProgress(this, GetTestProgressData(test, tstRslt, cBrd, cBrd.TTime, progress));
|
||||
Bridge.OnTestProgress(this, GetTestProgressData(test, tstRslt, true, cBrd, cBrd.TTime, progress));
|
||||
}
|
||||
/// Measurement loop - end
|
||||
|
||||
@@ -314,7 +314,7 @@ namespace TBF.BenchControl.TestMethods.FlyingStartCollectionMethod
|
||||
/// Corrected master pulses per liter
|
||||
if (tstRslt.VolumeCTV <= float.Epsilon)
|
||||
{
|
||||
tstRslt.ErrorMaster = 0.1f;
|
||||
tstRslt.ErrorMaster = 0.0f;
|
||||
}
|
||||
else
|
||||
{
|
||||
|
||||