(1) Easytherm: proc. params, (2) TankSelector: no. proc. params, seq. conditions added., SetQuidoBitOp, SelectTankOp, UnselectTankOp, ver. 2.12.490

This commit is contained in:
Milan Hanajik 2017-03-09 16:13:23 +01:00
parent efc3efcbfb
commit 8d572a650a
20 changed files with 429 additions and 148 deletions

View File

@ -265,7 +265,6 @@ namespace DeviceTest
{
radioButton1.Text = "SetTemperature(10)";
radioButton2.Text = "SetTemperature(20)";
radioButton3.Text = "GetSomethig(0,1)";
}
else if (className == "Modbus.TankSelector")
{
@ -286,7 +285,6 @@ namespace DeviceTest
{
radioButton21.Text = "SetTemperature(10)";
radioButton22.Text = "SetTemperature(20)";
radioButton23.Text = "GetSomethig(0,1)";
}
else if (className == "Modbus.TankSelector")
{
@ -307,7 +305,6 @@ namespace DeviceTest
{
radioButton31.Text = "SetTemperature(10)";
radioButton32.Text = "SetTemperature(20)";
radioButton33.Text = "GetSomethig(0,1)";
}
else if (className == "Modbus.TankSelector")
{
@ -659,7 +656,6 @@ namespace DeviceTest
{
operation1 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).SetTemperatureOp(10);
operation2 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).SetTemperatureOp(20);
operation3 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).ReadTemperatureOp();
}
else if (tbfComponent1forOp is TBF.BenchControl.Modbus.TankSelector.TankSelector)
{
@ -687,7 +683,6 @@ namespace DeviceTest
{
operation21 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).SetTemperatureOp(10);
operation22 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).SetTemperatureOp(20);
operation23 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).ReadTemperatureOp();
}
else if (tbfComponent2forOp is TBF.BenchControl.Modbus.TankSelector.TankSelector)
{
@ -715,7 +710,6 @@ namespace DeviceTest
{
operation31 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).SetTemperatureOp(10);
operation32 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).SetTemperatureOp(20);
operation33 = (tbfComponent1forOp as TBF.BenchControl.Modbus.Easytherm.Easytherm).ReadTemperatureOp();
}
else if (tbfComponent3forOp is TBF.BenchControl.Modbus.TankSelector.TankSelector)
{

View File

@ -361,6 +361,7 @@ namespace Results
if (!added)
{
WMeterRsltItemSpec item = GetItem(0);
item.Caption = "Prs.Err.";
item.Format = string.Format("Parse error: {0}", strArray[i]);
result.Add(item);
}
@ -369,6 +370,7 @@ namespace Results
catch
{
WMeterRsltItemSpec item = GetItem(0);
item.Caption = "Prs.Err.";
item.Format = string.Format("Parse error: {0}", strArray[i]);
result.Add(item);
}

View File

@ -364,7 +364,7 @@ namespace TBF.BenchControl.Elde
{
string statusPStr = ((ulong)bufferedStatusP).ToString("x16");
log.InfoFormat("RunDeviceBefore() StatusP = {0}", statusPStr);
Program.MainWnd.UpdateStatusP(statusPStr);
//Program.MainWnd.UpdateStatusP(statusPStr); /// TODO 170309
lastStatusP = bufferedStatusP;
}
}
@ -380,7 +380,7 @@ namespace TBF.BenchControl.Elde
{
string statusPStr = ((ulong)bufferedStatusP).ToString("x16");
log.InfoFormat("RunDeviceAfter() StatusP = {0}", statusPStr);
Program.MainWnd.UpdateStatusP(statusPStr);
//Program.MainWnd.UpdateStatusP(statusPStr); /// TODO 170309
lastStatusP = bufferedStatusP;
}
}

View File

@ -20,6 +20,9 @@ namespace TBF.BenchControl.Modbus.Easytherm
private float temperatureSetPoint;
private bool temperatureSetPointValid;
public float requiredTemp { get { return easythermCfg.ProcParams.RequiredTemp; } }
public Easytherm()
{
}
@ -58,9 +61,18 @@ namespace TBF.BenchControl.Modbus.Easytherm
}
/// <summary>
/// Set Easytherm controller required temperature
/// Set Easytherm controller to required temperature procedure parameter
/// </summary>
/// <param name="temperature">output value</param>
/// <returns>true = OK, false = any error</returns>
public bool SetRequiredTemperature()
{
return SetTemperature(requiredTemp);
}
/// <summary>
/// Set Easytherm controller to specified temperature
/// </summary>
/// <param name="temperature">Temperature in °C</param>
/// <returns>true = OK, false = any error</returns>
public bool SetTemperature(float temperature)
{
@ -123,22 +135,20 @@ namespace TBF.BenchControl.Modbus.Easytherm
/// <summary>
/// Events: SetOpututsDone, Error
/// </summary>
/// <param name="temperatureSetpoint">Reference to a variable for the pressure in Bar</param>
/// <returns>SetOutputsOp instance reference casted to IOperaton</returns>
public IOperation SetTemperatureOp(ushort temperatureSetpoint)
public IOperation SetRequiredTemperatureOp()
{
return new SetTemperatureOp(this, temperatureSetpoint);
return new SetRequiredTemperatureOp(this);
}
/// <summary>
/// Events: pressureDone, Error
/// Events: SetOpututsDone, Error
/// </summary>
/// <param name="outValue">Reference to a variable for the pressure in Bar</param>
/// <param name="setOutputsDone">Event returned when SetOutput is done</param>
/// <param name="temperature">Reference to a variable for the pressure in Bar</param>
/// <returns>SetOutputsOp instance reference casted to IOperaton</returns>
public IOperation ReadTemperatureOp()
public IOperation SetTemperatureOp(float temperature)
{
return new ReadTemperatureOp(this);
return new SetTemperatureOp(this, temperature);
}
}
}

View File

@ -2,9 +2,8 @@
/// Copyright (c) 2017 Sensus Metering Systems
///
using System;
using System.Collections.Generic;
using System.IO;
using System.Xml.Serialization;
using Config.Entities;
using TBF.BenchControl.Generic;
namespace TBF.BenchControl.Modbus.Easytherm
@ -18,13 +17,27 @@ namespace TBF.BenchControl.Modbus.Easytherm
///
public byte ModbusAddress; /// 1..255
/// <summary> Procedure parameters </summary>
[XmlIgnore]
public ProcParams ProcParams;
public override IParamsProvider GetProcedureParams() { return ProcParams; }
public override IParamsProvider CreateProcedureParams(Procedure procedure)
{
ProcParams procParams = new ProcParams();
procParams.UpdateProcedureParams(Name, procedure);
return procParams;
}
/// Private parameterless constructor invoked by all other (public) constructors
EasythermCfg()
{
Name = "Easytherm";
ParentName = "Modbus";
ModbusAddress = 49;
}
ProcParams = new ProcParams();
}
public EasythermCfg(IComponentFactory factory)
: this()

View File

@ -1,41 +1,27 @@
///
/// Copyright (c) 2017 Sensus Metering Systems
///
using System;
using System.IO;
using System.Text;
using System.Xml.Serialization;
using Config.Entities;
using TBF.BenchControl.Generic;
using TBF.Resources;
namespace TBF.BenchControl.Modbus.TankSelector
namespace TBF.BenchControl.Modbus.Easytherm
{
public class ProcParams : ProcedureParamsBase, IParamsProvider, IProcedureParams
{
public float TempHotHeating; /// [°C] target temperature for hot water heating
public float TempHotCooling; /// [°C] target temperature for hot water cooling
public float TempWarmHeating; /// [°C] target temperature for warm water heating
public float TempWarmCooling; /// [°C] target temperature for warm water cooling
public float TempColdCooling; /// [°C] target temperature for cold water cooling
public float RequiredTemp; /// [°C] target temperature for temperature controlled
public override void InitializeAll()
{
TempHotHeating = 20.0f;
TempHotCooling = 20.0f;
TempWarmHeating = 20.0f;
TempWarmCooling = 20.0f;
TempColdCooling = 20.0f;
RequiredTemp = 20.0f;
}
string[] paramNames = new string[]
{
Strings.T_hot_heating,
Strings.T_hot_cooling,
Strings.T_warm_heating,
Strings.T_warm_cooling,
Strings.T_cold_cooling,
Strings.Required_temperature_C,
};
public override string ParamName(int i) { return paramNames[i]; }
public override int ParamsCount() { return paramNames.Length; }
@ -44,11 +30,7 @@ namespace TBF.BenchControl.Modbus.TankSelector
{
switch (i)
{
case 0: return TempHotHeating.ToString();
case 1: return TempHotCooling.ToString();
case 2: return TempWarmHeating.ToString();
case 3: return TempWarmCooling.ToString();
case 4: return TempColdCooling.ToString();
case 0: return RequiredTemp.ToString();
default: return string.Empty;
}
}
@ -57,28 +39,28 @@ namespace TBF.BenchControl.Modbus.TankSelector
{
switch (i)
{
case 0: TempHotHeating = Utils.ParseUFloat(strValue); return;
case 1: TempHotCooling = Utils.ParseUFloat(strValue); return;
case 2: TempWarmHeating = Utils.ParseUFloat(strValue); return;
case 3: TempWarmCooling = Utils.ParseUFloat(strValue); return;
case 4: TempColdCooling = Utils.ParseUFloat(strValue); return;
case 0: RequiredTemp = Utils.ParseUFloat(strValue); return;
default: return;
}
}
/// <summary>
/// Verifiy the string representation of the parameter
/// </summary>
/// <param name="i">Parameter ID</param>
/// <param name="strValue">String representation of the parameter</param>
/// <param name="message">In case false is returned this is the error messsage to be displayed</param>
/// <returns>true = parameter OK, false = parameter NOK</returns>
public bool ValidateParam(int i, string strValue, out string message)
{
message = string.Empty;
float dummy;
float temp;
switch (i)
{
case 0: /// T_hot_heating
case 1: /// T_hot_cooling
case 2: /// T_warm_heating
case 3: /// T_warm_cooling
case 4: /// T_cold_cooling
if (Utils.TryParseUFloat(strValue, out dummy)) return true;
if (Utils.TryParseUFloat(strValue, out temp) && temp > 0 && temp < 100.0f)
return true;
break;
default:
message = "Invalid index";
@ -91,11 +73,7 @@ namespace TBF.BenchControl.Modbus.TankSelector
void CopyContentTo(ProcParams prms)
{
prms.TempHotHeating = this.TempHotHeating;
prms.TempHotCooling = this.TempHotCooling;
prms.TempWarmHeating = this.TempWarmHeating;
prms.TempWarmCooling = this.TempWarmCooling;
prms.TempColdCooling = this.TempColdCooling;
prms.RequiredTemp = this.RequiredTemp;
}
public IParamsProvider Clone()

View File

@ -7,15 +7,14 @@ using TBF.Boxes;
namespace TBF.BenchControl.Modbus.Easytherm
{
public class ReadTemperatureOp : IOperation
public class SetRequiredTemperatureOp : IOperation
{
private static readonly ILog log = LogManager.GetLogger(typeof(SetTemperatureOp));
public override string ToString() { return string.Format("SetOutputsOp(.,{0},{1})", outValue, eventDone); }
private static readonly ILog log = LogManager.GetLogger(typeof(SetRequiredTemperatureOp));
public override string ToString() { return string.Format("SetRequiredTemperatureOp({0})", eventDone); }
/// Set by the constructor
readonly Easytherm easytherm;
readonly Event eventDone;
ushort outValue;
/// <summary>
/// Events: PressureInDone, PressureOutDone or Error
@ -23,25 +22,24 @@ namespace TBF.BenchControl.Modbus.Easytherm
/// <param name="easytherm">Pressure meter reference</param>
/// <param name="pressure">Reference to the measured pressure variable, value is in bar</param>
/// <param name="eventDone">Event to be returned by Run() when completed OK</param>
public ReadTemperatureOp(Easytherm easytherm, Event eventDone)
public SetRequiredTemperatureOp(Easytherm easytherm, Event eventDone)
{
if (easytherm == null) throw new ArgumentNullException("easytherm");
this.easytherm = easytherm;
//this.outValue = outValue;
this.eventDone = eventDone;
log.Debug(this.ToString());
}
public ReadTemperatureOp(Easytherm easytherm)
: this(easytherm, Event.Done)
public SetRequiredTemperatureOp(Easytherm easytherm)
: this(easytherm, Event.ConditionMet)
{
}
/// <summary>Start this operation</summary>
public void Start()
{
easytherm.GetSomething(0, 1);
}
easytherm.SetRequiredTemperature();
}
/// <summary>Run this operation</summary>
public Event Run()

View File

@ -10,7 +10,7 @@ namespace TBF.BenchControl.Modbus.Easytherm
public class SetTemperatureOp : IOperation
{
private static readonly ILog log = LogManager.GetLogger(typeof(SetTemperatureOp));
public override string ToString() { return string.Format("SetTemperatureOp(.,{0},{1})", temperatureSetpoint, eventDone); }
public override string ToString() { return string.Format("SetTemperatureOp({0},{1})", temperatureSetpoint, eventDone); }
/// Set by the constructor
readonly Easytherm easytherm;

View File

@ -73,6 +73,28 @@ namespace TBF.BenchControl.Modbus.QuidoRS
SendOutputs(currentOutputs);
}
/// <summary>
/// Set bit(s) specified by a bitMask. Leave other bits unaffeced.
/// </summary>
/// <param name="bitMask">Specifies bit(s) to set</param>
/// <param name="outputs">output value</param>
public void SetBit(ushort bitMask)
{
currentOutputs = (UInt16)((Int32)currentOutputs | (Int32)bitMask);
SendOutputs(currentOutputs);
}
/// <summary>
/// Reset bit(s) specified by a bitMask. Leave other bits unaffeced.
/// </summary>
/// <param name="bitMask">Specifies bit(s) to reset</param>
/// <param name="outputs">output value</param>
public void ResetBit(ushort bitMask)
{
currentOutputs = (UInt16)((Int32)currentOutputs & (~(Int32)bitMask));
SendOutputs(currentOutputs);
}
private void SendOutputs(ushort outputs)
{
byte[] msg = new byte[11];

View File

@ -3,45 +3,59 @@ namespace TBF.BenchControl.Modbus.TankSelector
{
public class SelectTankOp : IOperation
{
public enum OpSpecifier
{
None,
SelectTank,
UnselectTank, /// tankNo is ignored, the selected tank is unselected
}
TankSelector tankSelector;
OpSpecifier currentOp;
int tankNo;
ushort bitMask;
bool alreadySet;
int time;
public SelectTankOp(TankSelector tankSelector, OpSpecifier op, int tankNo)
public SelectTankOp(TankSelector tankSelector, int tankNo)
{
this.tankSelector = tankSelector;
this.currentOp = op;
if (currentOp == OpSpecifier.SelectTank) this.tankNo = tankNo;
this.tankNo = tankNo;
this.bitMask = (ushort)((tankNo == 1) ? 1 : ((tankNo == 2) ? 2 : ((tankNo == 3) ? 4 : 0)));
}
/// <summary>Start this operation</summary>
public void Start()
{
switch (currentOp)
if (tankSelector.CurrentlySelectedTankValid && (tankNo == tankSelector.CurrentlySelectedTank))
{
case OpSpecifier.SelectTank:
tankSelector.SetOutputs((tankNo == 1) ? 1u : ((tankNo == 2) ? 2u : ((tankNo == 3) ? 4u : 0)));
break;
case OpSpecifier.UnselectTank:
tankSelector.SetOutputs((tankNo == 1) ? 8u : ((tankNo == 2) ? 16u : ((tankNo == 3) ? 32u : 0)));
break;
default:
break;
alreadySet = true;
}
else
{
tankSelector.CurrentlySelectedTank = tankNo;
tankSelector.CurrentlySelectedTankValid = true;
alreadySet = false;
time = 0;
tankSelector.QuidoRS.SetBit(bitMask);
}
}
/// <summary>Run this operation</summary>
public Event Run()
{
tankSelector.SetOutputs(0);
return Event.ConditionMet;
if (alreadySet)
{
return Event.ConditionMet;
}
else if (time == 0)
{
tankSelector.QuidoRS.ResetBit(bitMask);
time++;
return Event.ConditionNotMet;
}
else if (time <= 60)
{
time++;
return Event.ConditionNotMet;
}
else
{
return Event.ConditionMet;
}
}
/// <summary>Stop this operation</summary>

View File

@ -0,0 +1,57 @@

namespace TBF.BenchControl.Modbus.TankSelector
{
public class SetQuidoBitOp : IOperation
{
public enum OpSpecifier
{
None,
SelectTank,
UnselectTank, /// tankNo is ignored, the selected tank is unselected
}
readonly TBF.BenchControl.Modbus.QuidoRS.QuidoRS quidoRS;
readonly ushort bitMask;
readonly bool set; /// true = set, false = reset
readonly Event eventDone;
public SetQuidoBitOp(TBF.BenchControl.Modbus.QuidoRS.QuidoRS quidoRS, TankSelector.QuidoOutputs bitMask, bool set)
: this(quidoRS, (ushort)bitMask, set, Event.ConditionMet)
{
}
public SetQuidoBitOp(TBF.BenchControl.Modbus.QuidoRS.QuidoRS quidoRS, ushort bitMask, bool set)
: this(quidoRS, bitMask, set, Event.ConditionMet)
{
}
public SetQuidoBitOp(TBF.BenchControl.Modbus.QuidoRS.QuidoRS quidoRS, ushort bitMask, bool set, Event eventDone)
{
this.quidoRS = quidoRS;
this.bitMask = bitMask;
this.set = set;
this.eventDone = eventDone;
}
/// <summary>Start this operation</summary>
public void Start()
{
if (set)
quidoRS.SetBit(bitMask);
else
quidoRS.ResetBit(bitMask);
}
/// <summary>Run this operation</summary>
public Event Run()
{
return eventDone;
}
/// <summary>Stop this operation</summary>
public void Stop()
{
}
}
}

View File

@ -18,7 +18,7 @@ namespace TBF.BenchControl.Modbus.TankSelector
readonly TankSelectorCfg tankSelectorCfg;
readonly TBF.BenchControl.Modbus.QuidoRS.QuidoRS quidoRS;
public readonly TBF.BenchControl.Modbus.QuidoRS.QuidoRS QuidoRS;
readonly TBF.BenchControl.Modbus.Easytherm.Easytherm hotHeating;
readonly TBF.BenchControl.Modbus.Easytherm.Easytherm hotCooling;
@ -31,10 +31,13 @@ namespace TBF.BenchControl.Modbus.TankSelector
IList<IOperation> sequenceConditions;
public int CurrentlySelectedTank;
public bool CurrentlySelectedTankValid;
/// <summary>
/// Quido digital out board outputs assignment
/// </summary>
private enum QuidoOutputs
public enum QuidoOutputs : ushort
{
None = 0,
SelectColdTank = 0x0001,
@ -62,14 +65,15 @@ namespace TBF.BenchControl.Modbus.TankSelector
{
tankSelectorCfg = cfg as TankSelectorCfg;
quidoRS = (TBF.BenchControl.Modbus.QuidoRS.QuidoRS)TbfComponents.FindComponent(cfg.ParentName, components);
if (quidoRS == null) throw new Exception(string.Format("Cannot find parent '{0}' of the component {1}", cfg.ParentName, Name));
QuidoRS = (TBF.BenchControl.Modbus.QuidoRS.QuidoRS)TbfComponents.FindComponent(cfg.ParentName, components);
if (QuidoRS == null) throw new Exception(string.Format("Cannot find parent '{0}' of the component {1}", cfg.ParentName, Name));
hotHeating = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.HotWaterHeating, components);
hotCooling = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.HotWaterCooling, components);
warmHeating = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.WarmWaterHeating, components);
warmCooling = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.WarmWaterCooling, components);
coldCooling = (TBF.BenchControl.Modbus.Easytherm.Easytherm)TbfComponents.FindComponent(tankSelectorCfg.ColdWaterCooling, components);
if (hotHeating == null) throw new Exception(string.Format("Component '{0}' cannot find temperature controller '{1}'", Name, tankSelectorCfg.HotWaterHeating));
if (hotCooling == null) throw new Exception(string.Format("Component '{0}' cannot find temperature controller '{1}'", Name, tankSelectorCfg.HotWaterCooling));
if (warmHeating == null) throw new Exception(string.Format("Component '{0}' cannot find temperature controller '{1}'", Name, tankSelectorCfg.WarmWaterHeating));
@ -78,34 +82,96 @@ namespace TBF.BenchControl.Modbus.TankSelector
CreateConditions(true);
CurrentlySelectedTankValid = false;
log.Debug(this.ToString());
}
public void Initialize() { SetOutputs(0); }
public void Initialize()
{
SetOutputs(0);
}
public void RunDeviceBefore() {}
public void RunDeviceAfter() {}
public void StopDevice() {}
void CreateConditions(bool createAll)
{
sequenceConditionNames = new List<string>();
sequenceConditionNames.Add(Strings.Select_COLD_tank);
sequenceConditionNames.Add(Strings.Select_WARM_tank);
sequenceConditionNames.Add(Strings.Select_HOT_tank);
sequenceConditionNames.Add(Strings.Unselect_COLD_tank);
sequenceConditionNames.Add(Strings.Unselect_WARM_tank);
sequenceConditionNames.Add(Strings.Unselect_HOT_tank);
sequenceConditions = new List<IOperation>();
if (createAll)
{
sequenceConditions = new List<IOperation>();
sequenceConditions.Add(new SelectTankOp(this, SelectTankOp.OpSpecifier.SelectTank, 1));
sequenceConditions.Add(new SelectTankOp(this, SelectTankOp.OpSpecifier.SelectTank, 2));
sequenceConditions.Add(new SelectTankOp(this, SelectTankOp.OpSpecifier.SelectTank, 3));
sequenceConditions.Add(new SelectTankOp(this, SelectTankOp.OpSpecifier.UnselectTank, 1));
sequenceConditions.Add(new SelectTankOp(this, SelectTankOp.OpSpecifier.UnselectTank, 2));
sequenceConditions.Add(new SelectTankOp(this, SelectTankOp.OpSpecifier.UnselectTank, 3));
}
sequenceConditionNames.Add(Strings.Select_COLD_tank);
if (createAll) sequenceConditions.Add(new SelectTankOp(this, 1));
sequenceConditionNames.Add(Strings.Select_WARM_tank);
if (createAll) sequenceConditions.Add(new SelectTankOp(this, 2));
sequenceConditionNames.Add(Strings.Select_HOT_tank);
if (createAll) sequenceConditions.Add(new SelectTankOp(this, 3));
sequenceConditionNames.Add(Strings.Unselect_COLD_tank);
if (createAll) sequenceConditions.Add(new UnselectTankOp(this, 1));
sequenceConditionNames.Add(Strings.Unselect_WARM_tank);
if (createAll) sequenceConditions.Add(new UnselectTankOp(this, 2));
sequenceConditionNames.Add(Strings.Unselect_HOT_tank);
if (createAll) sequenceConditions.Add(new UnselectTankOp(this, 3));
sequenceConditionNames.Add(Strings.Set_hot_water_heating_temperature);
if (createAll) sequenceConditions.Add(hotHeating.SetRequiredTemperatureOp());
sequenceConditionNames.Add(Strings.Set_hot_water_cooling_temperature);
if (createAll) sequenceConditions.Add(hotCooling.SetRequiredTemperatureOp());
sequenceConditionNames.Add(Strings.Set_warm_water_heating_temperature);
if (createAll) sequenceConditions.Add(warmHeating.SetRequiredTemperatureOp());
sequenceConditionNames.Add(Strings.Set_warm_water_cooling_temperature);
if (createAll) sequenceConditions.Add(warmCooling.SetRequiredTemperatureOp());
sequenceConditionNames.Add(Strings.Set_cold_water_cooling_temperature);
if (createAll) sequenceConditions.Add(coldCooling.SetRequiredTemperatureOp());
sequenceConditionNames.Add("Start heating hot water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.HeatingHotTank, true));
sequenceConditionNames.Add("Stop heating hot water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.HeatingHotTank, false));
sequenceConditionNames.Add("Start cooling hot water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingHotTank, true));
sequenceConditionNames.Add("Stop cooling hot water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingHotTank, false));
sequenceConditionNames.Add("Start heating warm water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.HeatingWarmTank, true));
sequenceConditionNames.Add("Stop heating warm water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.HeatingWarmTank, false));
sequenceConditionNames.Add("Start cooling warm water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingWarmTank, true));
sequenceConditionNames.Add("Stop cooling warm water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingWarmTank, false));
sequenceConditionNames.Add("Start cooling cold water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingColdTank, true));
sequenceConditionNames.Add("Stop cooling cold water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.CoolingColdTank, false));
sequenceConditionNames.Add("Start mixing water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.Mixing, true));
sequenceConditionNames.Add("Stop mixing water");
if (createAll) sequenceConditions.Add(new SetQuidoBitOp(QuidoRS, QuidoOutputs.Mixing, false));
}
@ -115,7 +181,7 @@ namespace TBF.BenchControl.Modbus.TankSelector
/// <param name="outputs">output value</param>
public void SetOutputs(uint outputs)
{
quidoRS.SetOutputs((ushort)outputs);
QuidoRS.SetOutputs((ushort)outputs);
}

View File

@ -1,9 +1,6 @@
///
/// Copyright (c) 2017 Sensus Metering Systems
///
using System;
using System.Xml.Serialization;
using Config.Entities;
using TBF.BenchControl.Generic;
namespace TBF.BenchControl.Modbus.TankSelector
@ -22,24 +19,11 @@ namespace TBF.BenchControl.Modbus.TankSelector
public string ColdWaterCooling; /// Name of the component communicating with the temperature controller
/// <summary> Procedure parameters </summary>
[XmlIgnore]
public ProcParams ProcParams;
public override IParamsProvider GetProcedureParams() { return ProcParams; }
public override IParamsProvider CreateProcedureParams(Procedure procedure)
{
ProcParams procParams = new ProcParams();
procParams.UpdateProcedureParams(Name, procedure);
return procParams;
}
/// Private parameterless constructor invoked by all other (public) constructors
TankSelectorCfg()
{
Name = "TankSelector";
ParentName = "QuidoRS";
ProcParams = new ProcParams();
}
public TankSelectorCfg(IComponentFactory factory)

View File

@ -0,0 +1,66 @@

namespace TBF.BenchControl.Modbus.TankSelector
{
public class UnselectTankOp : IOperation
{
TankSelector tankSelector;
int tankNo;
ushort bitMask;
bool alreadyUnselected;
int time;
public UnselectTankOp(TankSelector tankSelector, int tankNo)
{
this.tankSelector = tankSelector;
this.tankNo = tankNo;
this.bitMask = (ushort)((tankNo == 1) ? 8 : ((tankNo == 2) ? 0x10 : ((tankNo == 3) ? 0x20 : 0)));
}
/// <summary>Start this operation</summary>
public void Start()
{
if (tankSelector.CurrentlySelectedTankValid && (tankNo == 0))
{
alreadyUnselected = true;
}
else
{
tankSelector.CurrentlySelectedTank = tankNo;
tankSelector.CurrentlySelectedTankValid = true;
alreadyUnselected = false;
time = 0;
tankSelector.QuidoRS.SetBit(bitMask);
}
}
/// <summary>Run this operation</summary>
public Event Run()
{
if (alreadyUnselected)
{
return Event.ConditionMet;
}
else if (time == 0)
{
tankSelector.QuidoRS.ResetBit(bitMask);
time++;
return Event.ConditionNotMet;
}
else if (time <= 60)
{
time++;
return Event.ConditionNotMet;
}
else
{
return Event.ConditionMet;
}
}
/// <summary>Stop this operation</summary>
public void Stop()
{
}
}
}

View File

@ -264,7 +264,7 @@ namespace TBF
IList<IComponent> other = new List<IComponent>();
foreach (var cmpnt in TbfComponents)
{
if (cmpnt is TBF.BenchControl.Modbus.TankSelector.TankSelector) other.Add(cmpnt);
if (cmpnt is TBF.BenchControl.Modbus.Easytherm.Easytherm) other.Add(cmpnt);
}
if (other.Count > 0)

View File

@ -29,5 +29,5 @@ using System.Runtime.InteropServices;
// Build Number
// Revision
//
[assembly: AssemblyVersion("2.12.489.1")]
[assembly: AssemblyFileVersion("2.12.489.1")]
[assembly: AssemblyVersion("2.12.490.1")]
[assembly: AssemblyFileVersion("2.12.490.1")]

View File

@ -3255,6 +3255,15 @@ namespace TBF.Resources {
}
}
/// <summary>
/// Looks up a localized string similar to Required temperature [°C].
/// </summary>
internal static string Required_temperature_C {
get {
return ResourceManager.GetString("Required_temperature_C", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Resistance.
/// </summary>
@ -3364,7 +3373,7 @@ namespace TBF.Resources {
}
/// <summary>
/// Looks up a localized string similar to Select COLD tank.
/// Looks up a localized string similar to Select COLD water.
/// </summary>
internal static string Select_COLD_tank {
get {
@ -3382,7 +3391,7 @@ namespace TBF.Resources {
}
/// <summary>
/// Looks up a localized string similar to Select HOT tank.
/// Looks up a localized string similar to Select HOT water.
/// </summary>
internal static string Select_HOT_tank {
get {
@ -3391,7 +3400,7 @@ namespace TBF.Resources {
}
/// <summary>
/// Looks up a localized string similar to Select WORM tank.
/// Looks up a localized string similar to Select WARM water.
/// </summary>
internal static string Select_WARM_tank {
get {
@ -3471,6 +3480,15 @@ namespace TBF.Resources {
}
}
/// <summary>
/// Looks up a localized string similar to Set cold water cooling temperature.
/// </summary>
internal static string Set_cold_water_cooling_temperature {
get {
return ResourceManager.GetString("Set_cold_water_cooling_temperature", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Set flow.
/// </summary>
@ -3480,6 +3498,24 @@ namespace TBF.Resources {
}
}
/// <summary>
/// Looks up a localized string similar to Set hot water cooling temperature.
/// </summary>
internal static string Set_hot_water_cooling_temperature {
get {
return ResourceManager.GetString("Set_hot_water_cooling_temperature", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Set hot water heating temperature.
/// </summary>
internal static string Set_hot_water_heating_temperature {
get {
return ResourceManager.GetString("Set_hot_water_heating_temperature", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Set route.
/// </summary>
@ -3489,6 +3525,24 @@ namespace TBF.Resources {
}
}
/// <summary>
/// Looks up a localized string similar to Set warm water cooling temperature.
/// </summary>
internal static string Set_warm_water_cooling_temperature {
get {
return ResourceManager.GetString("Set_warm_water_cooling_temperature", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Set warm water heating temperature.
/// </summary>
internal static string Set_warm_water_heating_temperature {
get {
return ResourceManager.GetString("Set_warm_water_heating_temperature", resourceCulture);
}
}
/// <summary>
/// Looks up a localized string similar to Setting temperature.
/// </summary>
@ -4393,7 +4447,7 @@ namespace TBF.Resources {
}
/// <summary>
/// Looks up a localized string similar to Unselect COLD tank.
/// Looks up a localized string similar to Unselect COLD water.
/// </summary>
internal static string Unselect_COLD_tank {
get {
@ -4402,7 +4456,7 @@ namespace TBF.Resources {
}
/// <summary>
/// Looks up a localized string similar to Unselect HOT tank.
/// Looks up a localized string similar to Unselect HOT water.
/// </summary>
internal static string Unselect_HOT_tank {
get {
@ -4411,7 +4465,7 @@ namespace TBF.Resources {
}
/// <summary>
/// Looks up a localized string similar to Unselect WARM tank.
/// Looks up a localized string similar to Unselect WARM water.
/// </summary>
internal static string Unselect_WARM_tank {
get {

View File

@ -1401,4 +1401,7 @@
<data name="Other" xml:space="preserve">
<value>&lt;other&gt;</value>
</data>
<data name="Required_temperature_C" xml:space="preserve">
<value>Solltemperatur [°C]</value>
</data>
</root>

View File

@ -1634,22 +1634,22 @@
<value>Do you want to retry RoI detection?</value>
</data>
<data name="Select_COLD_tank" xml:space="preserve">
<value>Select COLD tank</value>
<value>Select COLD water</value>
</data>
<data name="Select_HOT_tank" xml:space="preserve">
<value>Select HOT tank</value>
<value>Select HOT water</value>
</data>
<data name="Select_WARM_tank" xml:space="preserve">
<value>Select WORM tank</value>
<value>Select WARM water</value>
</data>
<data name="Unselect_COLD_tank" xml:space="preserve">
<value>Unselect COLD tank</value>
<value>Unselect COLD water</value>
</data>
<data name="Unselect_HOT_tank" xml:space="preserve">
<value>Unselect HOT tank</value>
<value>Unselect HOT water</value>
</data>
<data name="Unselect_WARM_tank" xml:space="preserve">
<value>Unselect WARM tank</value>
<value>Unselect WARM water</value>
</data>
<data name="T_cold_cooling" xml:space="preserve">
<value>T cold cooling</value>
@ -1669,4 +1669,22 @@
<data name="Other" xml:space="preserve">
<value>Other</value>
</data>
<data name="Required_temperature_C" xml:space="preserve">
<value>Required temperature [°C]</value>
</data>
<data name="Set_cold_water_cooling_temperature" xml:space="preserve">
<value>Set cold water cooling temperature</value>
</data>
<data name="Set_hot_water_cooling_temperature" xml:space="preserve">
<value>Set hot water cooling temperature</value>
</data>
<data name="Set_hot_water_heating_temperature" xml:space="preserve">
<value>Set hot water heating temperature</value>
</data>
<data name="Set_warm_water_cooling_temperature" xml:space="preserve">
<value>Set warm water cooling temperature</value>
</data>
<data name="Set_warm_water_heating_temperature" xml:space="preserve">
<value>Set warm water heating temperature</value>
</data>
</root>

View File

@ -508,7 +508,8 @@
<Compile Include="BenchControl\Modbus\Easytherm\EasythermCfgCtrl.designer.cs">
<DependentUpon>EasythermCfgCtrl.cs</DependentUpon>
</Compile>
<Compile Include="BenchControl\Modbus\Easytherm\ReadTemperatureOp.cs" />
<Compile Include="BenchControl\Modbus\Easytherm\ProcParams.cs" />
<Compile Include="BenchControl\Modbus\Easytherm\SetRequiredTemperatureOp.cs" />
<Compile Include="BenchControl\Modbus\Easytherm\SetTemperatureOp.cs" />
<Compile Include="BenchControl\Modbus\Enums.cs" />
<Compile Include="BenchControl\Modbus\Common\Modbus.cs" />
@ -541,8 +542,8 @@
<Compile Include="BenchControl\Modbus\QuidoRS\Factory.cs" />
<Compile Include="BenchControl\Modbus\QuidoRS\SetOutputsOp.cs" />
<Compile Include="BenchControl\Modbus\TankSelector\Factory.cs" />
<Compile Include="BenchControl\Modbus\TankSelector\ProcParams.cs" />
<Compile Include="BenchControl\Modbus\TankSelector\SelectTankOp.cs" />
<Compile Include="BenchControl\Modbus\TankSelector\SetQuidoBitOp.cs" />
<Compile Include="BenchControl\Modbus\TankSelector\TankSelector.cs" />
<Compile Include="BenchControl\Modbus\TankSelector\TankSelectorCfg.cs" />
<Compile Include="BenchControl\Modbus\TankSelector\TankSelectorCfgCtrl.cs">
@ -551,6 +552,7 @@
<Compile Include="BenchControl\Modbus\TankSelector\TankSelectorCfgCtrl.designer.cs">
<DependentUpon>TankSelectorCfgCtrl.cs</DependentUpon>
</Compile>
<Compile Include="BenchControl\Modbus\TankSelector\UnselectTankOp.cs" />