Diverter times saved in SummaryResults and AllResults, timing of 'end' measurement slightly changed, ver. 2.17.706

This commit is contained in:
Milan Hanajik
2017-10-18 12:08:15 +02:00
parent 3822c6f5ab
commit 8b321e36db
4 changed files with 34 additions and 17 deletions
+9
View File
@@ -39,8 +39,17 @@ namespace Results.Entities
public virtual double VolumeCTV { get; set; } /// [l] Volume conventional true value
public virtual double VolumeMaster { get; set; } /// [l] Volume from the master flow meter
public virtual double ErrorMaster { get; set; } /// [%]
public virtual float DiverterStart { get; set; } /// [s] Diverter switch time when test starts
public virtual float DivStart10 { get; set; } /// [s] Diverter switch time when test starts at level 10 (e.g. 10%) (not mapped to DB)
public virtual float DivStart50 { get; set; } /// [s] Diverter switch time when test starts at level 50 (e.g. 50%) (not mapped to DB)
public virtual float DivStart90 { get; set; } /// [s] Diverter switch time when test starts at level 90 (e.g. 90%) (not mapped to DB)
public virtual float DiverterEnd { get; set; } /// [s] Diverter switch time when test ends
public virtual float DivEnd90 { get; set; } /// [s] Diverter switch time when test starts at level 90 (e.g. 90%) (not mapped to DB)
public virtual float DivEnd50 { get; set; } /// [s] Diverter switch time when test starts at level 50 (e.g. 50%) (not mapped to DB)
public virtual float DivEnd10 { get; set; } /// [s] Diverter switch time when test starts at level 10 (e.g. 10%) (not mapped to DB)
public virtual int ErrorFlags { get; set; } /// bitfield : bit0=E1, bit1=E2, bit2=E3, etc.
public virtual sbyte ErrorFlagsMd { get; set; } /// 0=off, 1=info, 2=on (evaluated in MeterTestRslt.Passed)