Improve logging and error handling in FlyingStart and FlyingStartMassCollection sequences.
This commit is contained in:
parent
6dc9520897
commit
8229c5eb63
@ -607,6 +607,11 @@ namespace TBF.Rig.TestMethods.FlyingStart
|
||||
meterRslt.VolumeRef = tstRslt.VolumeCTV * meterRslt.TestTime / tstRslt.TestTime;
|
||||
meterRslt.PulsesMaster = tstRslt.PulsesMaster * meterRslt.TestTime / tstRslt.TestTime;
|
||||
|
||||
log.Debug($"TEST TIME meterRslt.TimestampStart:{meterRslt.TimestampStart}, meterRslt.TimestampEnd:{meterRslt.TimestampEnd}, meterRslt.TestTime:{meterRslt.TestTime}");
|
||||
log.Debug($"TEST VOLUME meterRslt.VolumeStart:{meterRslt.VolumeStart}, meterRslt.VolumeEnd:{meterRslt.VolumeEnd}, meterRslt.VolumeMeter:{meterRslt.VolumeMeter}");
|
||||
log.Debug($"TEST modified by time: meterRslt.VolumeRef:{meterRslt.VolumeRef}, meterRslt.PulsesMaster:{meterRslt.PulsesMaster}");
|
||||
|
||||
|
||||
if (iPerl != null)
|
||||
{
|
||||
if (iPerl.ResultCode != 0 && (meterRslt.WaterMeter.ResultCode & (int)Results.Entities.ResultCode.OptoErrorCodeMask) == 0)
|
||||
|
||||
@ -635,7 +635,18 @@ namespace TBF.Rig.TestMethods.FlyingStartMassCollection
|
||||
while (!e.Contains(Event.ScaleDone) && !e.Contains(Event.Next));
|
||||
///
|
||||
tMass2 = StateMachine.Time;
|
||||
log.WarnFormat("End mass = {0}kg", EndMass);
|
||||
try
|
||||
{
|
||||
if (EndMass != null)
|
||||
{
|
||||
log.WarnFormat("End mass = {0}kg", EndMass.Val);
|
||||
}
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
log.ErrorFormat("Error while logging end mass: {0}", ex.Message);
|
||||
}
|
||||
|
||||
TestEndTime = DateTime.Now;
|
||||
|
||||
if (test.DoDrainingAfter)
|
||||
|
||||
Loading…
Reference in New Issue