ControlBoards, IControlBoard iface, Devices, test methods.

This commit is contained in:
Milan Hanajik
2020-05-21 15:55:02 +02:00
parent 6df9261697
commit 7b321abb30
222 changed files with 3995 additions and 1284 deletions
@@ -17,6 +17,40 @@ namespace TBF.BenchControl.TestMethods.Adjustment
{
private static readonly ILog log = LogManager.GetLogger(typeof(AdjustmentSeq));
/// <summary>
/// Check capabilities of devces in the output path required for this test method
/// </summary>
/// <param name="devices">Devices</param>
/// <returns>true when capabilities of devices are OK</returns>
public static bool CheckDeviceCaps(Config.Entities.Test test, OutputPath devices, out string message)
{
if (!(StateMachine.ControlBoard is ControlBoard.Legacy.ControlBoardDev) &&
!(StateMachine.ControlBoard is ControlBoard.New.CBoard))
{
/// Control board does not support this method
message = string.Format("{0}: {1}", test.Name, Strings.Test_bench_does_not_suport_selected_test_method);
return false;
}
if (!(devices.FlowMeter is GenericDevices.IFlowMeter))
{
/// Flow meter is missing
message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_flow_meter);
return false;
}
if (!(devices.RegulValve is GenericDevices.IRegulValve))
{
/// Regulation valve is missing
message = string.Format("{0}: {1}", test.Name, Strings.Missing_a_regulation_valve);
return false;
}
message = string.Empty;
return true;
}
System.Windows.Forms.Form modelessDlg;
///
delegate void ErrorsFormDlgt(AdjustmentSeq myRef, IList<GenericDevices.IWaterMeter> waterMeters);
@@ -85,7 +119,7 @@ namespace TBF.BenchControl.TestMethods.Adjustment
IList<Event> e; /// Events from currently running operations
Event retVal = Event.Done;
Elde.ControlBoardDev cBrd = StateMachine.ControlBoard;
TBF.BenchControl.ControlBoard.IControlBoard cBrd = StateMachine.ControlBoard;
checkUiOp = new Operations.CheckUIOp(true); /// Runs in more then one state
processDataLoggingOp = new TBF.BenchControl.Operations.ProcessDataLoggingOp(processDataLogger, this, false);
@@ -102,7 +136,10 @@ namespace TBF.BenchControl.TestMethods.Adjustment
}
}
cBrd.SetFiltersPidShortPulses(filters, outPath.PidCoef, (test.TolerRed == 0) ? 0 : 1);
if (cBrd is ControlBoard.Legacy.ControlBoardDev)
{
(cBrd as ControlBoard.Legacy.ControlBoardDev).SetFiltersPidShortPulses(filters, outPath.PidCoef, (test.TolerRed == 0) ? 0 : 1);
}
IList<IOperation> readTempPressOps = new List<IOperation>();
if (benchPath.TempMtrUp != null) readTempPressOps.Add(benchPath.TempMtrUp.ReadTempOp(ref TempUp));
@@ -117,11 +154,10 @@ namespace TBF.BenchControl.TestMethods.Adjustment
if (heatMetersPath != null) readTempPressOps.Add(heatMetersPath.TMeterRefCold2.ReadTempOp(ref TempRefLo2));
LtrPerRefPulse = outPath.FlowMeter.LtrPerPulse; /// [ltr/pulse], nominal flow in [m3/h]
int totalPulses = (int)(test.Volume / LtrPerRefPulse + 0.5f);
int flowSetTime = 0;
/// Start the test, initialize test results
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath, totalPulses));
Bridge.OnTestSelected(this, new TestSelectedEventArgs(test, repetitionNr, inPath, benchPath, outPath, sensPath, heatMetersPath));
string testName = Results.Utils.GetTestName(test.Name, test.Repeats, repetitionNr);
/// Read pressure and temperature once before calling Bridge.OnTestSelected(...)
@@ -223,7 +259,7 @@ namespace TBF.BenchControl.TestMethods.Adjustment
State.Create(string.Format("{0}({1}) : Setting the flow", test.Method, test.Name))
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperation(outPath.RegulValve.SetFlowOp(outPath.FlowMeter, test.Qfrom, test.Qto, RefFlow, FlowSettingTimeoutSec))
.AddOperation(cBrd.SetFlowOp(test.Qfrom, test.Qto, RefFlow, FlowSettingTimeoutSec))
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
@@ -342,7 +378,7 @@ namespace TBF.BenchControl.TestMethods.Adjustment
.AddOperation(checkUiOp)
.AddOperations(readTempPressOps)
.AddOperations(measureOperations)
.AddOperation(cBrd.StartMeasurementOp(outPath, Elde.TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses))
.AddOperation(cBrd.StartTestOp(test))
.EnterState();
do {
e = StateMachine.WaitRunDevsRunOps();
@@ -369,8 +405,8 @@ namespace TBF.BenchControl.TestMethods.Adjustment
case Event.MeasurementCompleted: goto one_test_completed;
}
RefFreq.Val = cBrd.ReferenceFreq;
RefFlow.Val = cBrd.ReferenceFlow;
RefFrequency.Val = cBrd.RefFrequency;
RefFlow.Val = cBrd.RefFlow;
UpdateAllStatistics(StateMachine.Time);
Bridge.OnProcessData(this, new ProcessDataEventArgs(test, repetitionNr, Config.Entities.Progress.Test));
@@ -404,8 +440,8 @@ namespace TBF.BenchControl.TestMethods.Adjustment
tstRslt.StartTime = TestStartTime;
tstRslt.EndTime = TestEndTime;
tstRslt.FlowSetTime = flowSetTime;
tstRslt.TestTime = cBrd.TTime; /// [s] measurement time
tstRslt.PulsesMaster = Convert.ToDouble(cBrd.EtPulses(0)); /// Pulses of the master flow meter (test total)
tstRslt.TestTime = cBrd.TestTime; /// [s] measurement time
tstRslt.PulsesMaster = Convert.ToDouble(cBrd.RefPulses); /// Pulses of the master flow meter (test total)
tstRslt.MassStartRaw = 0;
tstRslt.MassStart = 0;
tstRslt.MassEndRaw = 0;
@@ -449,7 +485,7 @@ namespace TBF.BenchControl.TestMethods.Adjustment
meterRslt.VolumeEnd = 0; /// liter
meterRslt.VolumeMeter = meterRslt.PulsesMeter * regReader.LtrsPerPulse; /// liter
meterRslt.VolumeRef = meterRslt.PulsesMaster * tstRslt.ConstMaster; /// liter
meterRslt.TestTime = cBrd.ImpulseTime(i + 1);
meterRslt.TestTime = cBrd.PulsesWM(i + 1);
meterRslt.Error = Config.Formulas.ErrorFromVolumes(meterRslt.VolumeMeter, meterRslt.VolumeRef);
meterRslt.Passed = (meterRslt.Error >= test.GetErrLimLo(tstRslt.VolumeCTV, tstRslt.TestTime) + test.Uncertainty)
&& (meterRslt.Error <= test.GetErrLimHi(tstRslt.VolumeCTV, tstRslt.TestTime) - test.Uncertainty);