ControlBoards, IControlBoard iface, Devices, test methods.
This commit is contained in:
@@ -0,0 +1,142 @@
|
||||
///
|
||||
/// Copyright (c) 2020 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Windows.Forms;
|
||||
using Config.Entities;
|
||||
using TBF.BenchControl.Generic;
|
||||
|
||||
namespace TBF.BenchControl.ControlBoard.Papouch
|
||||
{
|
||||
public partial class CBoardCfgCtrl : UserControl, IComponentCfgCtrl
|
||||
{
|
||||
ComponentParametersDlg parent;
|
||||
|
||||
public bool ShowMore { get { return false; } }
|
||||
|
||||
CBoardCfg config;
|
||||
public IComponentCfg Config
|
||||
{
|
||||
get { return config as IComponentCfg; }
|
||||
set
|
||||
{
|
||||
config = value as CBoardCfg;
|
||||
Redraw();
|
||||
}
|
||||
}
|
||||
|
||||
public CBoardCfgCtrl()
|
||||
{
|
||||
InitializeComponent();
|
||||
}
|
||||
|
||||
private void ControlBoardCfgCtrl_Load(object sender, EventArgs e)
|
||||
{
|
||||
parent = ParentForm as ComponentParametersDlg;
|
||||
if (parent == null) return;
|
||||
|
||||
if (parent.TbfComponents != null)
|
||||
{
|
||||
foreach (var cmpnt in parent.TbfComponents)
|
||||
{
|
||||
if (TbfComponents.CmpntFactoryFromClassName(cmpnt.ClassName) is Modbus.Common.Factory)
|
||||
{
|
||||
parentNameComboBox.Items.Add(cmpnt.Name);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
for (QuidoVariant v = 0; v < QuidoVariant.Count; v++) variantComboBox.Items.Add(v.ToString());
|
||||
|
||||
Redraw();
|
||||
}
|
||||
|
||||
public void Closing()
|
||||
{
|
||||
}
|
||||
|
||||
void Redraw()
|
||||
{
|
||||
if (config == null) return; /// Control was not loaded, settings were not changed
|
||||
|
||||
classNameLabel.Text = config.Factory.ClassName;
|
||||
nameTextBox.Text = config.Name;
|
||||
parentNameComboBox.Text = string.IsNullOrEmpty(config.ParentName) ? "---" : config.ParentName;
|
||||
variantComboBox.Text = config.Variant.ToString();
|
||||
modbusAddressTextBox.Text = config.ModbusAddress.ToString();
|
||||
vValveRangeLoTextBox.Text = config.VirtualValvesRangeLo.ToString();
|
||||
vValveRangeHiTextBox.Text = config.VirtualValvesRangeHi.ToString();
|
||||
}
|
||||
|
||||
public void Unlock()
|
||||
{
|
||||
nameTextBox.Enabled = true;
|
||||
parentNameComboBox.Enabled = true;
|
||||
variantComboBox.Enabled = true;
|
||||
modbusAddressTextBox.Enabled = true;
|
||||
vValveRangeLoTextBox.Enabled = true;
|
||||
vValveRangeHiTextBox.Enabled = true;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Verify current user controls for validity.
|
||||
/// Called when user wants to close/save the configuration.
|
||||
/// </summary>
|
||||
/// <returns>See VerifyFlags</returns>
|
||||
public CfgUpdateFlags VerifyCfg(ref string message)
|
||||
{
|
||||
CfgUpdateFlags flags = CfgUpdateFlags.None;
|
||||
|
||||
int dummy;
|
||||
if (!parentNameComboBox.Items.Contains(parentNameComboBox.Text))
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "Invalid 'Parent Name'";
|
||||
}
|
||||
if (!variantComboBox.Items.Contains(variantComboBox.Text))
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "Invalid 'Variant'";
|
||||
}
|
||||
if (!int.TryParse(modbusAddressTextBox.Text, out dummy) || dummy < 0 || dummy > 255)
|
||||
{
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
message += Environment.NewLine + "'Modbus Address' should be between 0 and 255";
|
||||
}
|
||||
if (!int.TryParse(vValveRangeLoTextBox.Text, out dummy) || dummy < 0 || dummy > 63)
|
||||
{
|
||||
message += "Virtual valves range Lo is invalid";
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
}
|
||||
if (!int.TryParse(vValveRangeHiTextBox.Text, out dummy) || dummy < 0 || dummy > 63)
|
||||
{
|
||||
message += "Virtual valves range Hi is invalid";
|
||||
flags |= CfgUpdateFlags.Error;
|
||||
}
|
||||
|
||||
return flags;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Save settings to the configuration class.
|
||||
/// </summary>
|
||||
public CfgUpdateFlags UpdateCfg()
|
||||
{
|
||||
CfgUpdateFlags flags = CfgUpdateFlags.RestartRqrd;
|
||||
|
||||
if (config == null) return CfgUpdateFlags.Error; /// Control was not loaded, settings were not changed
|
||||
|
||||
this.Name = nameTextBox.Text;
|
||||
config.ParentName = parentNameComboBox.Text.Equals("---") ? string.Empty : parentNameComboBox.Text;
|
||||
for (QuidoVariant v = 0; v < QuidoVariant.Count; v++)
|
||||
{
|
||||
if (variantComboBox.Text == v.ToString()) { config.Variant = v; break; }
|
||||
}
|
||||
config.ModbusAddress = (byte)int.Parse(modbusAddressTextBox.Text);
|
||||
config.VirtualValvesRangeLo = int.Parse(vValveRangeLoTextBox.Text);
|
||||
config.VirtualValvesRangeHi = int.Parse(vValveRangeHiTextBox.Text);
|
||||
|
||||
return flags;
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue