Uni.XyzStartStopTest[WithDiv]Op, etc., AdjustmentSeq and all FlyingStartXyzSeq completed, ver. 3.1.1630
This commit is contained in:
@@ -0,0 +1,142 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using log4net;
|
||||
using TBF.Rig.GenericDevices;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class FlyingStartStopTestOp : IOperation
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(FlyingStartStopTestOp));
|
||||
public override string ToString() { return string.Format("FlyingStartStopTestOp()"); }
|
||||
|
||||
/// Arguments of the constructor
|
||||
readonly UniCB uniCB;
|
||||
readonly TBF.Rig.Uni.RegValve.RegValve regV;
|
||||
readonly TBF.Rig.Uni.FlowMeter.FlowMeter flowMeter;
|
||||
readonly double qFrom;
|
||||
readonly double qTo;
|
||||
readonly int pulsesCount; /// Number of reference pulses for a complete test
|
||||
|
||||
/// <summary>
|
||||
/// Operation for a Flying start-stop test (constructor)
|
||||
///
|
||||
/// Events: OpArgumentError .... invalid arguments, test cannot be started
|
||||
/// StartingTest ....... starting a test
|
||||
/// TestInProgress ..... test was successfully started, test is running
|
||||
/// TestCompleted ...... test was successfully completed
|
||||
/// Error .............. unspecified error while running a test
|
||||
/// </summary>
|
||||
/// <param name="cb">Control board component</param>
|
||||
/// <param name="devices">Components used by the test</param>
|
||||
/// <param name="qFrom">Flow lower limit</param>
|
||||
/// <param name="qTo">Flow upper limit</param>
|
||||
/// <param name="pulsesCount">Test duration - number of reference flow meter pulses</param>
|
||||
public FlyingStartStopTestOp(UniCB cb, OutputPath devices, double qFrom, double qTo, int pulsesCount)
|
||||
{
|
||||
this.uniCB = cb;
|
||||
|
||||
flowMeter = devices.FlowMeter as TBF.Rig.Uni.FlowMeter.FlowMeter;
|
||||
if (flowMeter == null) throw new ArgumentNullException("Invalid flow meter");
|
||||
|
||||
regV = devices.RegValve as TBF.Rig.Uni.RegValve.RegValve;
|
||||
if (regV == null) throw new ArgumentNullException("Invalid regulation valve");
|
||||
|
||||
this.qFrom = qFrom;
|
||||
this.qTo = qTo;
|
||||
this.pulsesCount = pulsesCount;
|
||||
|
||||
log.Debug(this.ToString());
|
||||
}
|
||||
|
||||
/// Internal state of this operation
|
||||
enum OpState
|
||||
{
|
||||
StartingTest,
|
||||
TestInProgress,
|
||||
TestCompleted,
|
||||
}
|
||||
|
||||
OpState opState;
|
||||
|
||||
/// <summary>
|
||||
/// Start this operation
|
||||
/// </summary>
|
||||
public void Start()
|
||||
{
|
||||
log.InfoFormat("Op.Start() RV#={0} Et#={1} Qfrom={2} Qto={3}", regV.Idx1, flowMeter.Idx1, qFrom, qTo);
|
||||
|
||||
/// Start the test (and the flow measurement)
|
||||
uniCB.StartTest(false, flowMeter.Idx1, 0, 40, true, false, false, pulsesCount, 0);
|
||||
|
||||
opState = OpState.StartingTest;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Run this operation
|
||||
/// </summary>
|
||||
/// <returns>
|
||||
/// Event.OpArgumentError .... invalid arguments, test cannot be started
|
||||
/// Event.StartingTest ....... starting a test
|
||||
/// Event.TestInProgress ..... test was successfully started, test is running
|
||||
/// Event.TestCompleted ...... test was successfully completed
|
||||
/// Event.Error .............. unspecified error while running a test
|
||||
/// </returns>
|
||||
public Event Run()
|
||||
{
|
||||
log.DebugFormat("Op.Run() opState={0}", opState);
|
||||
|
||||
switch (opState)
|
||||
{
|
||||
case OpState.StartingTest:
|
||||
|
||||
if (qFrom < 0 || qFrom >= qTo || qTo > 1.25 * flowMeter.NominalFlow)
|
||||
{
|
||||
return Event.OpArgumentError; /// Invalid qFrom, qTo
|
||||
}
|
||||
|
||||
if (!flowMeter.MsrmntAvailable || /// Flow measurement not started yet
|
||||
(uniCB.State & (ulong)StatusP.TestInProgress) == 0 || /// Test was not started yet
|
||||
(flowMeter.ReadFlow()) == 0) /// Measured flow is 0
|
||||
{
|
||||
return Event.StartingTest; /// Flow regulation cannot be started
|
||||
}
|
||||
|
||||
/// Start flow regulation
|
||||
double reqFlowAve = (qFrom + qTo) / 2;
|
||||
double reqFlowLo = (0.7 * qFrom) + (0.3 * reqFlowAve); /// Move the lower limit 15% of the range up
|
||||
double reqFlowHi = (0.7 * qTo) + (0.3 * reqFlowAve); /// Move the upper limit 15% of the range down
|
||||
///
|
||||
uniCB.SetFlow(false, regV.Idx1, 2000 * reqFlowLo / flowMeter.NominalFlow,
|
||||
2000 * reqFlowHi / flowMeter.NominalFlow);
|
||||
|
||||
opState = OpState.TestInProgress;
|
||||
return Event.TestInProgress;
|
||||
|
||||
case OpState.TestInProgress:
|
||||
|
||||
if ((uniCB.State & (ulong)StatusP.TestCompleted) == 0)
|
||||
{
|
||||
return Event.TestInProgress; /// Test was not completed yet
|
||||
}
|
||||
opState = OpState.TestCompleted;
|
||||
return Event.TestCompleted;
|
||||
|
||||
case OpState.TestCompleted:
|
||||
default:
|
||||
return Event.TestCompleted;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Stop this operation
|
||||
/// </summary>
|
||||
public void Stop()
|
||||
{
|
||||
log.Info("Op.Stop()");
|
||||
uniCB.Stop(false);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,189 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using log4net;
|
||||
using TBF.Rig.GenericDevices;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class FlyingStartStopTestWithDivOp : IOperation
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(FlyingStartStopTestWithDivOp));
|
||||
public override string ToString() { return string.Format("FlyingStartStopTestWithDivOp()"); }
|
||||
|
||||
/// Arguments of the constructor
|
||||
readonly UniCB uniCB;
|
||||
readonly TBF.Rig.Uni.RegValve.RegValve regV;
|
||||
readonly TBF.Rig.Uni.FlowMeter.FlowMeter flowMeter;
|
||||
readonly TBF.Rig.Uni.Diverter.Diverter div;
|
||||
readonly double qFrom;
|
||||
readonly double qTo;
|
||||
readonly int pulsesCount; /// Number of reference pulses for a complete test
|
||||
readonly int massPulsesCount; /// Number of reference pulses for mass collection
|
||||
readonly bool readDivTransition;
|
||||
readonly bool isProlongedTest;
|
||||
|
||||
/// <summary>
|
||||
/// Operation for a Flying start-stop test with a diverter (constructor)
|
||||
///
|
||||
/// Events: OpArgumentError ...... invalid arguments, test cannot be started
|
||||
/// StartingTest ......... starting a test
|
||||
/// TestInProgress ....... test was successfully started, test is running
|
||||
/// TestPart2InProgress .. first part when water is diverted to a tank was successfully completed, part2 in progress,
|
||||
/// prolonged method only: (massPulsesCount GT 0) and (massPulsesCount LT pulsesCount)
|
||||
/// TestCompleted ........ test was successfully completed
|
||||
/// Error ................ unspecified error while running a test
|
||||
/// </summary>
|
||||
/// <param name="cb">Control board component</param>
|
||||
/// <param name="devices">Components used by the test</param>
|
||||
/// <param name="qFrom">Flow lower limit</param>
|
||||
/// <param name="qTo">Flow upper limit</param>
|
||||
/// <param name="pulsesCount">Test duration - number of reference flow meter pulses</param>
|
||||
/// <param name="massPulsesCount">Test part 1 duration - number of reference flow meter pulses<</param>
|
||||
public FlyingStartStopTestWithDivOp(UniCB cb, OutputPath devices, double qFrom, double qTo,
|
||||
int pulsesCount, int massPulsesCount, bool readDivTransition)
|
||||
{
|
||||
this.uniCB = cb;
|
||||
|
||||
flowMeter = devices.FlowMeter as TBF.Rig.Uni.FlowMeter.FlowMeter;
|
||||
if (flowMeter == null) throw new ArgumentNullException("Invalid flow meter");
|
||||
|
||||
regV = devices.RegValve as TBF.Rig.Uni.RegValve.RegValve;
|
||||
if (regV == null) throw new ArgumentNullException("Invalid regulation valve");
|
||||
|
||||
div = devices.Diverter as TBF.Rig.Uni.Diverter.Diverter;
|
||||
if (div == null) throw new ArgumentNullException("Invalid diverter");
|
||||
|
||||
this.qFrom = qFrom;
|
||||
this.qTo = qTo;
|
||||
this.pulsesCount = pulsesCount;
|
||||
this.massPulsesCount = massPulsesCount;
|
||||
this.readDivTransition = readDivTransition;
|
||||
this.isProlongedTest = (0 < massPulsesCount) && (massPulsesCount < pulsesCount);
|
||||
|
||||
log.Debug(this.ToString());
|
||||
}
|
||||
|
||||
/// Internal states of this operation
|
||||
enum OpState
|
||||
{
|
||||
StartingTest,
|
||||
ReadingDivTransition,
|
||||
TestInProgress,
|
||||
TestPart1InProgress, /// prolonged test only
|
||||
TestPart2InProgress, /// prolonged test only
|
||||
TestCompleted,
|
||||
}
|
||||
|
||||
OpState opState;
|
||||
|
||||
/// <summary>
|
||||
/// Start this operation
|
||||
/// </summary>
|
||||
public void Start()
|
||||
{
|
||||
log.InfoFormat("Op.Start() RV#={0} Et#={1} Div#={2} Qfrom={3} Qto={4}", regV.Idx1, flowMeter.Idx1, div.DiverterNr, qFrom, qTo);
|
||||
|
||||
/// Start the test (and the flow measurement)
|
||||
uniCB.StartTest(false, flowMeter.Idx1, div.DiverterNr, 40, true, true, false, pulsesCount, massPulsesCount);
|
||||
|
||||
opState = OpState.StartingTest;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Run this operation
|
||||
/// </summary>
|
||||
/// <returns>
|
||||
/// Event.OpArgumentError ...... invalid arguments, test cannot be started
|
||||
/// Event.StartingTest ......... starting a test
|
||||
/// Event.TestInProgress ....... test was successfully started, test is running
|
||||
/// Event.TestPart1InProgress .. first part when water is diverted to a tank was successfully completed, part2 in progress,
|
||||
/// Event.TestPart2InProgress .. first part when water is diverted to a tank was successfully completed, part2 in progress,
|
||||
/// prolonged method only: (massPulsesCount GT 0) and (massPulsesCount LT pulsesCount)
|
||||
/// Event.TestCompleted ........ test was successfully completed
|
||||
/// Event.Error ................ unspecified error while running a test
|
||||
/// </returns>
|
||||
public Event Run()
|
||||
{
|
||||
log.DebugFormat("Op.Run() opState={0}", opState);
|
||||
|
||||
switch (opState)
|
||||
{
|
||||
case OpState.StartingTest:
|
||||
|
||||
if (qFrom < 0 || qFrom >= qTo || qTo > 1.25 * flowMeter.NominalFlow)
|
||||
{
|
||||
return Event.OpArgumentError; /// Invalid qFrom, qTo
|
||||
}
|
||||
|
||||
if (!flowMeter.MsrmntAvailable || /// Flow measurement not started yet
|
||||
(uniCB.State & (ulong)StatusP.TestInProgress) == 0 || /// Test was not started yet
|
||||
(flowMeter.ReadFlow()) == 0) /// Measured flow is 0
|
||||
{
|
||||
return Event.StartingTest; /// Flow regulation cannot be started
|
||||
}
|
||||
|
||||
/// Start flow regulation
|
||||
double reqFlowAve = (qFrom + qTo) / 2;
|
||||
double reqFlowLo = (0.7 * qFrom) + (0.3 * reqFlowAve); /// Move the lower limit 15% of the range up
|
||||
double reqFlowHi = (0.7 * qTo) + (0.3 * reqFlowAve); /// Move the upper limit 15% of the range down
|
||||
///
|
||||
uniCB.SetFlow(false, regV.Idx1, 2000 * reqFlowLo / flowMeter.NominalFlow,
|
||||
2000 * reqFlowHi / flowMeter.NominalFlow);
|
||||
|
||||
opState = readDivTransition ? OpState.ReadingDivTransition
|
||||
: (isProlongedTest ? OpState.TestPart1InProgress : OpState.TestInProgress);
|
||||
return isProlongedTest ? Event.TestPart1InProgress : Event.TestInProgress;
|
||||
|
||||
case OpState.ReadingDivTransition:
|
||||
|
||||
/// Read diverter transition data
|
||||
uniCB.ReadDiverterTransition(false, div.DiverterNr);
|
||||
opState = isProlongedTest ? OpState.TestPart1InProgress : OpState.TestInProgress;
|
||||
return isProlongedTest ? Event.TestPart1InProgress : Event.TestInProgress;
|
||||
|
||||
case OpState.TestInProgress:
|
||||
|
||||
if ((uniCB.State & (ulong)StatusP.TestCompleted) == 0)
|
||||
{
|
||||
return Event.TestInProgress; /// Test was not completed yet
|
||||
}
|
||||
opState = OpState.TestCompleted;
|
||||
return Event.TestCompleted;
|
||||
|
||||
case OpState.TestPart1InProgress:
|
||||
|
||||
if ((uniCB.State & (ulong)StatusP.TestCompleted) == 0)
|
||||
{
|
||||
return Event.TestPart1InProgress; /// Test was not completed yet
|
||||
}
|
||||
opState = OpState.TestPart2InProgress;
|
||||
return Event.TestPart2InProgress;
|
||||
|
||||
case OpState.TestPart2InProgress:
|
||||
|
||||
if ((uniCB.State & (ulong)StatusP.TestCompleted) == 0)
|
||||
{
|
||||
/// Test was not completed yet
|
||||
return Event.TestPart2InProgress;
|
||||
}
|
||||
opState = OpState.TestCompleted;
|
||||
return Event.TestCompleted;
|
||||
|
||||
case OpState.TestCompleted:
|
||||
default:
|
||||
return Event.TestCompleted;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Stop this operation
|
||||
/// </summary>
|
||||
public void Stop()
|
||||
{
|
||||
log.Info("Op.Stop()");
|
||||
uniCB.Stop(false);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,142 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using log4net;
|
||||
using TBF.Rig.GenericDevices;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class StandingStartStopTestOp : IOperation
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(StandingStartStopTestOp));
|
||||
public override string ToString() { return string.Format("StandingStartStopTestOp()"); }
|
||||
|
||||
/// Arguments of the constructor
|
||||
readonly UniCB uniCB;
|
||||
readonly TBF.Rig.Uni.RegValve.RegValve regV;
|
||||
readonly TBF.Rig.Uni.FlowMeter.FlowMeter flowMeter;
|
||||
readonly double qFrom;
|
||||
readonly double qTo;
|
||||
readonly int pulsesCount; /// Number of reference pulses for a complete test
|
||||
|
||||
/// <summary>
|
||||
/// Operation for a Standing start-stop test (constructor)
|
||||
///
|
||||
/// Events: OpArgumentError .... invalid arguments, test cannot be started
|
||||
/// StartingTest ....... starting a test
|
||||
/// TestInProgress ..... test was successfully started, test is running
|
||||
/// TestCompleted ...... test was successfully completed
|
||||
/// Error .............. unspecified error while running a test
|
||||
/// </summary>
|
||||
/// <param name="cb">Control board component</param>
|
||||
/// <param name="devices">Components used by the test</param>
|
||||
/// <param name="qFrom">Flow lower limit</param>
|
||||
/// <param name="qTo">Flow upper limit</param>
|
||||
/// <param name="pulsesCount">Test duration - number of reference flow meter pulses</param>
|
||||
public StandingStartStopTestOp(UniCB cb, OutputPath devices, double qFrom, double qTo, int pulsesCount)
|
||||
{
|
||||
this.uniCB = cb;
|
||||
|
||||
flowMeter = devices.FlowMeter as TBF.Rig.Uni.FlowMeter.FlowMeter;
|
||||
if (flowMeter == null) throw new ArgumentNullException("Invalid flow meter");
|
||||
|
||||
regV = devices.RegValve as TBF.Rig.Uni.RegValve.RegValve;
|
||||
if (regV == null) throw new ArgumentNullException("Invalid regulation valve");
|
||||
|
||||
this.qFrom = qFrom;
|
||||
this.qTo = qTo;
|
||||
this.pulsesCount = pulsesCount;
|
||||
|
||||
log.Debug(this.ToString());
|
||||
}
|
||||
|
||||
/// Internal states of this operation
|
||||
enum OpState
|
||||
{
|
||||
StartingTest,
|
||||
TestInProgress,
|
||||
TestCompleted,
|
||||
}
|
||||
|
||||
OpState opState;
|
||||
|
||||
/// <summary>
|
||||
/// Start this operation
|
||||
/// </summary>
|
||||
public void Start()
|
||||
{
|
||||
log.InfoFormat("Op.Start() RV#={0} Et#={1} Qfrom={2} Qto={3}", regV.Idx1, flowMeter.Idx1, qFrom, qTo);
|
||||
|
||||
/// Start the test (and the flow measurement)
|
||||
uniCB.StartTest(false, flowMeter.Idx1, 0, 40, false, false, true, pulsesCount, 0);
|
||||
|
||||
opState = OpState.StartingTest;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Run this operation
|
||||
/// </summary>
|
||||
/// <returns>
|
||||
/// Event.OpArgumentError .... invalid arguments, test cannot be started
|
||||
/// Event.StartingTest ....... starting a test
|
||||
/// Event.TestInProgress ..... test was successfully started, test is running
|
||||
/// Event.TestCompleted ...... test was successfully completed
|
||||
/// Event.Error .............. unspecified error while running a test
|
||||
/// </returns>
|
||||
public Event Run()
|
||||
{
|
||||
log.DebugFormat("Op.Run() opState={0}", opState);
|
||||
|
||||
switch (opState)
|
||||
{
|
||||
case OpState.StartingTest:
|
||||
|
||||
if (qFrom < 0 || qFrom >= qTo || qTo > 1.25 * flowMeter.NominalFlow)
|
||||
{
|
||||
return Event.OpArgumentError; /// Invalid qFrom, qTo
|
||||
}
|
||||
|
||||
if (!flowMeter.MsrmntAvailable || /// Flow measurement not started yet
|
||||
(uniCB.State & (ulong)StatusP.TestInProgress) == 0 || /// Test was not started yet
|
||||
(flowMeter.ReadFlow()) == 0) /// Measured flow is 0
|
||||
{
|
||||
return Event.StartingTest; /// Flow regulation cannot be started
|
||||
}
|
||||
|
||||
/// Start flow regulation
|
||||
double reqFlowAve = (qFrom + qTo) / 2;
|
||||
double reqFlowLo = (0.7 * qFrom) + (0.3 * reqFlowAve); /// Move the lower limit 15% of the range up
|
||||
double reqFlowHi = (0.7 * qTo) + (0.3 * reqFlowAve); /// Move the upper limit 15% of the range down
|
||||
///
|
||||
uniCB.SetFlow(false, regV.Idx1, 2000 * reqFlowLo / flowMeter.NominalFlow,
|
||||
2000 * reqFlowHi / flowMeter.NominalFlow);
|
||||
|
||||
opState = OpState.TestInProgress;
|
||||
return Event.TestInProgress;
|
||||
|
||||
case OpState.TestInProgress:
|
||||
|
||||
if ((uniCB.State & (ulong)StatusP.TestCompleted) == 0)
|
||||
{
|
||||
return Event.TestInProgress; /// Test was not completed yet
|
||||
}
|
||||
opState = OpState.TestCompleted;
|
||||
return Event.TestCompleted;
|
||||
|
||||
case OpState.TestCompleted:
|
||||
default:
|
||||
return Event.TestCompleted;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Stop this operation
|
||||
/// </summary>
|
||||
public void Stop()
|
||||
{
|
||||
log.Info("Op.Stop()");
|
||||
uniCB.Stop(false);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -1,192 +0,0 @@
|
||||
///
|
||||
/// Copyright (c) 2013-2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using log4net;
|
||||
using TBF.Rig.GenericDevices;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class StartMeasurementOp : IOperation
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(StartMeasurementOp));
|
||||
public override string ToString() { return string.Format("StartMeasurementOp()"); }
|
||||
|
||||
/// Set by the constructor
|
||||
readonly UniCB uniCB;
|
||||
readonly TBF.Rig.Uni.RegValve.RegValve regValve;
|
||||
readonly TBF.Rig.Uni.FlowMeter.FlowMeter flowMeter;
|
||||
readonly TBF.Rig.Uni.Diverter.Diverter diverter;
|
||||
readonly int regulValveStableTime;
|
||||
readonly double maximalFlow;
|
||||
readonly double qFrom;
|
||||
readonly double qTo;
|
||||
readonly int totalRefPulses; /// Number of reference pulses for a complete test
|
||||
readonly int massRefPulses; /// Number of reference pulses for mass collection
|
||||
readonly int delayBeforeFlowRegulation; /// Delay before flow control starts in seconds
|
||||
readonly TestMethods testMethod;
|
||||
|
||||
///
|
||||
/// Internal states of this operation
|
||||
///
|
||||
enum OpState
|
||||
{
|
||||
StartingTest,
|
||||
ResendCommand,
|
||||
WaitingBeforeValveMove,
|
||||
StartingFlowRegulation,
|
||||
OpCompleted,
|
||||
}
|
||||
OpState opState;
|
||||
|
||||
|
||||
int delayStartTime; /// StateMachine.Time snapshot when delay before flow regulation starts
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Starts the measurement.
|
||||
/// Events: MeasurementStarted
|
||||
/// </summary>
|
||||
/// <param name="cb">Control board component reference</param>
|
||||
/// <param name="devices">Specifies used components</param>
|
||||
/// <param name="method">Test method</param>
|
||||
/// <param name="totalRefPulses">Test duration in number of reference flowmeter pulses</param>
|
||||
/// <param name="filterConstant">Specifies filter for watermeter pulses</param>
|
||||
public StartMeasurementOp(IControlBoard cb, OutputPath devices, TestMethods method, double qFrom, double qTo,
|
||||
int refPulses, int delayBeforeFlowRegulation = 0)
|
||||
: this(cb, devices, method, qFrom, qTo, refPulses, refPulses, delayBeforeFlowRegulation)
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Starts the measurement.
|
||||
/// Events: MeasurementStarted
|
||||
/// </summary>
|
||||
/// <param name="cb">Control board component reference</param>
|
||||
/// <param name="devices">Specifies used components</param>
|
||||
/// <param name="method">Test method</param>
|
||||
/// <param name="refPulses">Test duration in number of reference flowmeter pulses</param>
|
||||
/// <param name="filterConstant">Specifies filter for watermeter pulses</param>
|
||||
public StartMeasurementOp(IControlBoard cb, OutputPath devices, TestMethods method, double qFrom, double qTo,
|
||||
int totalRefPulses, int massRefPulses, int delayBeforeFlowRegulation = 0)
|
||||
{
|
||||
this.uniCB = cb as UniCB;
|
||||
if (uniCB == null) throw new ArgumentNullException("Invalid control board");
|
||||
|
||||
flowMeter = devices.FlowMeter as TBF.Rig.Uni.FlowMeter.FlowMeter;
|
||||
if (flowMeter == null) throw new ArgumentNullException("Invalid flow meter");
|
||||
|
||||
regValve = devices.RegValve as TBF.Rig.Uni.RegValve.RegValve;
|
||||
if (regValve == null) throw new ArgumentNullException("Invalid regulation");
|
||||
|
||||
diverter = devices.Diverter as TBF.Rig.Uni.Diverter.Diverter;
|
||||
if (diverter == null) throw new ArgumentNullException("Invalid diverter");
|
||||
|
||||
this.testMethod = method;
|
||||
this.qFrom = qFrom;
|
||||
this.qTo = qTo;
|
||||
this.totalRefPulses = totalRefPulses;
|
||||
this.massRefPulses = massRefPulses;
|
||||
this.delayBeforeFlowRegulation = delayBeforeFlowRegulation;
|
||||
|
||||
maximalFlow = 1.25 * flowMeter.NominalFlow;
|
||||
log.Debug(this.ToString());
|
||||
}
|
||||
|
||||
void SendStartCommand()
|
||||
{
|
||||
//uniCB.SyncRoute();
|
||||
uniCB.StartTest(false, flowMeter.Idx1, diverter.DiverterNr, 20,
|
||||
testMethod == TestMethods.Diverter || testMethod == TestMethods.MassAndContinue || testMethod == TestMethods.Synchro,
|
||||
testMethod == TestMethods.Diverter || testMethod == TestMethods.MassAndContinue,
|
||||
testMethod == TestMethods.FixedStart,
|
||||
totalRefPulses, massRefPulses);
|
||||
}
|
||||
|
||||
/// <summary>Start this operation</summary>
|
||||
public void Start()
|
||||
{
|
||||
SendStartCommand();
|
||||
opState = OpState.StartingTest;
|
||||
}
|
||||
|
||||
/// <summary>Run this operation</summary>
|
||||
/// <returns>
|
||||
/// Event.FlowInDone or Event.FlowOutDone
|
||||
/// </returns>
|
||||
public Event Run()
|
||||
{
|
||||
if (opState == OpState.StartingTest)
|
||||
{
|
||||
ulong state = uniCB.State;
|
||||
log.DebugFormat("state = {0} {1} {2} {3}",
|
||||
(((ulong)state >> 48) & 0xFFFF).ToString("X4"),
|
||||
(((ulong)state >> 32) & 0xFFFF).ToString("X4"),
|
||||
(((ulong)state >> 16) & 0xFFFF).ToString("X4"),
|
||||
((ulong)state & 0xFFFF).ToString("X4"));
|
||||
|
||||
if ((state & (ulong)StatusP.TestInProgress) != 0)
|
||||
{
|
||||
log.Info("Test started");
|
||||
if (delayBeforeFlowRegulation > 0)
|
||||
{
|
||||
delayStartTime = StateMachine.Time;
|
||||
opState = OpState.WaitingBeforeValveMove;
|
||||
}
|
||||
else
|
||||
{
|
||||
opState = OpState.StartingFlowRegulation;
|
||||
}
|
||||
}
|
||||
else
|
||||
{
|
||||
//opState = OpState.ResendCommand;
|
||||
}
|
||||
|
||||
return Event.None;
|
||||
}
|
||||
else if (opState == OpState.ResendCommand)
|
||||
{
|
||||
SendStartCommand();
|
||||
opState = OpState.StartingTest;
|
||||
return Event.None;
|
||||
}
|
||||
else if (opState == OpState.WaitingBeforeValveMove)
|
||||
{
|
||||
if (StateMachine.Time - delayStartTime >= delayBeforeFlowRegulation)
|
||||
{
|
||||
opState = OpState.StartingFlowRegulation;
|
||||
}
|
||||
return Event.None;
|
||||
}
|
||||
else if (opState == OpState.StartingFlowRegulation)
|
||||
{
|
||||
///
|
||||
/// Done once, issues an appropriate ValveMove(...) command
|
||||
///
|
||||
if ((qFrom >= qTo) || (qFrom > maximalFlow) || (qTo <= 0))
|
||||
{
|
||||
return Event.OpArgumentError;
|
||||
}
|
||||
|
||||
log.InfoFormat("Run(): rv#={0} flowMtr#={1} TARGET: flowLo={2} flowHi={3}",
|
||||
regValve.Idx1, flowMeter.Idx1, qFrom, qTo);
|
||||
|
||||
double freqLo = 2000 * qFrom / flowMeter.NominalFlow;
|
||||
double freqHi = 2000 * qTo / flowMeter.NominalFlow;
|
||||
uniCB.SetFlow(false, regValve.Idx1, 2000 * qFrom / flowMeter.NominalFlow, 2000 * qTo / flowMeter.NominalFlow);
|
||||
opState = OpState.OpCompleted;
|
||||
return Event.None;
|
||||
}
|
||||
else if (opState == OpState.OpCompleted)
|
||||
{
|
||||
return Event.MeasurementStarted;
|
||||
}
|
||||
|
||||
return Event.None;
|
||||
}
|
||||
|
||||
/// <summary>Stop this operation</summary>
|
||||
public void Stop() { }
|
||||
}
|
||||
}
|
||||
@@ -38,7 +38,7 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
get {
|
||||
altString.Clear();
|
||||
altString.AppendFormat("Stat: {0}.{1}.{2}.{3}\n", (State >> 48) & 0xFF, (State >> 40) & 0xFF, (State >> 32) & 0xFF, Convert.ToUInt32(State & 0xFFFFFFFF).ToString("X6"));
|
||||
altString.AppendFormat("State: {0}.{1}.{2}.{3}\n", (State >> 48) & 0xFF, (State >> 40) & 0xFF, (State >> 32) & 0xFF, Convert.ToUInt32(State & 0xFFFFFFFF).ToString("X6"));
|
||||
altString.AppendFormat("DI: {0}\n", ToBin40(DigitalInputs));
|
||||
altString.AppendFormat("DO: {0}\n", ToBin40(((UInt64)Route) >> 8));
|
||||
altString.AppendFormat("AI0: {0:D3} AI1: {1:D3} AI2: {2:D3} AI3: {3:D3} AI4: {4:D3} AI5: {5:D3}\n",
|
||||
@@ -483,102 +483,31 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Start a test, Events: MeasurementStarted
|
||||
/// Start a standing start-stop test
|
||||
/// </summary>
|
||||
/// <param name="iParam">Int32 parameter 1</param>
|
||||
/// <param name="dParam1">Double parameter 1 (alternative lower flow limit)</param>
|
||||
/// <param name="dParam2">Double parameter 2 (alternative upper flow limit)</param>
|
||||
/// <returns>Operation</returns>
|
||||
public IOperation StartTestOp(Test test, int iParam = 0, double dParam1 = 0, double dParam2 = 0)
|
||||
/// <returns>Operation running a test</returns>
|
||||
public IOperation StandingStartStopTestOp(Test test, double qFrom, double qTo, int pulsesCount)
|
||||
{
|
||||
return new StandingStartStopTestOp(this, devices, qFrom, qTo, pulsesCount);
|
||||
}
|
||||
|
||||
/// Get total number of pulses
|
||||
int totalPulses = Convert.ToInt32(Math.Round(test.Volume / devices.FlowMeter.LtrPerPulse));
|
||||
/// <summary>
|
||||
/// Start a flying start-stop test
|
||||
/// </summary>
|
||||
/// <returns>Operation running a test</returns>
|
||||
public IOperation FlyingStartStopTestOp(Test test, double qFrom, double qTo, int pulsesCount)
|
||||
{
|
||||
return new FlyingStartStopTestOp(this, devices, qFrom, qTo, pulsesCount);
|
||||
}
|
||||
|
||||
/// Get method class string
|
||||
string methodClass;
|
||||
if (!StateMachine.TestMethod2Class.TryGetValue(test.Name, out methodClass)) return null;
|
||||
|
||||
if (methodClass.Contains("TestMethods.Adjustment."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.CombinedWithDetection."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.Synchro), dParam1, dParam2, totalPulses);
|
||||
}
|
||||
if (methodClass == "TestMethods.DiverterTest")
|
||||
{
|
||||
if (iParam == 0) return null;
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.Synchro), test.Qfrom, test.Qto, totalPulses / iParam);
|
||||
}
|
||||
if (methodClass == "TestMethods.Dummy")
|
||||
{
|
||||
}
|
||||
if (methodClass == "TestMethods.Endurance")
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FixedStart."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, TestMethods.Synchro, test.Qfrom, test.Qto, 2 * totalPulses, 10);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FixedStartAdvanced."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, TestMethods.Synchro, test.Qfrom, test.Qto, 2 * totalPulses, 10);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FixedStartDefferedEval."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, TestMethods.Synchro, test.Qfrom, test.Qto, 2 * totalPulses, 10);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FixedStartMassCollDeferredEval."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.Synchro), test.Qfrom, test.Qto, 2 * totalPulses, 10);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FixedStartMassCollection."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.FixedStart), test.Qfrom, test.Qto, 2 * totalPulses, 10);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FixedStartTankCollection."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.Synchro), test.Qfrom, test.Qto, (totalPulses * 5 / 4), 10);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FlyingStart."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FlyingStartFirstRepetWithMassColl."))
|
||||
{
|
||||
TestMethods tm = (iParam == 1) ? (TestMethods.Diverter | TestMethods.Synchro) : TestMethods.Synchro;
|
||||
return new StartMeasurementOp(this, devices, tm, test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FlyingStartMassCollComparative."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.Synchro), test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FlyingStartMassCollection."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.Synchro), test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FlyingStartMassCollProlonged."))
|
||||
{
|
||||
if (iParam == 0) return null;
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.Synchro), test.Qfrom, test.Qto, totalPulses, iParam);
|
||||
}
|
||||
if (methodClass.Contains("TestMethods.FlyingStartTankCollection."))
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, (TestMethods.Diverter | TestMethods.Synchro), test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
if (methodClass == "TestMethods.PulsesTest")
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
if (methodClass == "TestMethods.PulsesTestManual")
|
||||
{
|
||||
return new StartMeasurementOp(this, devices, TestMethods.Synchro, test.Qfrom, test.Qto, totalPulses);
|
||||
}
|
||||
|
||||
return null;
|
||||
/// <summary>
|
||||
/// Start a flying start-stop test with diverter
|
||||
/// </summary>
|
||||
/// <returns>Operation running a test</returns>
|
||||
public IOperation FlyingStartStopTestWithDivOp(Test test, double qFrom, double qTo, int pulsesCount,
|
||||
int massPulsesCount = 0, bool readDivTransition = true)
|
||||
{
|
||||
return new FlyingStartStopTestWithDivOp(this, devices, qFrom, qTo, pulsesCount, massPulsesCount, readDivTransition);
|
||||
}
|
||||
|
||||
public IOperation ReadDiverterTransitionOp(bool isStart, Sequences.Statistics plotter, int batchNr, string testName, int repetition)
|
||||
@@ -756,5 +685,10 @@ namespace TBF.Rig.ControlBoard.Uni
|
||||
|
||||
/// TODO
|
||||
}
|
||||
|
||||
public void SetFiltersPidShortPulses(int[] filters, float pidCoef, int shortPulses)
|
||||
{
|
||||
/// TODO
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue