FixedStartMassCollection : Diverter to tank after start valve is closed, 'Winiki lub E' support MeterTestRslt, ver. 2.30.1980
This commit is contained in:
parent
08b3ab45ba
commit
75766938be
@ -106,6 +106,13 @@ namespace Results.Entities
|
||||
public virtual bool IsDataStream() { return (RegReaderType == (int)RegisterReaderType.DataStream); }
|
||||
public virtual bool IsManual() { return (RegReaderType == (int)RegisterReaderType.Manual); }
|
||||
|
||||
public virtual string PassedOrErrorFlagsStr()
|
||||
{
|
||||
string eFlags = Utils.ErrorFlagsStr(ErrorIndicators);
|
||||
var str = string.IsNullOrEmpty(eFlags) ? PassedColorStr(null) : eFlags;
|
||||
return str;
|
||||
}
|
||||
|
||||
public virtual string PassedColorStr(string yesNoFormatOrEmpty)
|
||||
{
|
||||
if (string.IsNullOrEmpty(yesNoFormatOrEmpty))
|
||||
|
||||
@ -335,7 +335,8 @@ namespace Results
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Scale, "Scale", Quantity.String, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) != null) ? FormatStr(f, w.GetTestRslt(t).Scale()) : string.Empty));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.Diverter, "Diverter", Quantity.String, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) != null) ? FormatStr(f, w.GetTestRslt(t).Diverter()) : string.Empty));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.RegValve, "Reg. valve", Quantity.String, ItemCategory.TestResult, (w, t, u, f, p) => (w.GetTestRslt(t) != null) ? FormatStr(f, w.GetTestRslt(t).RegValve()) : string.Empty));
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.ResultOrErrorFlags, "Winiki lub E", Quantity.String, ItemCategory.MeterResult, (w, t, u, f, p) => FormatStr(f, w.PassedOrErrorFlagsStr()))); /// PL specific result
|
||||
AllItems.Add(new WMeterRsltItemSpec(ItemID.ResultOrErrorFlags, "Winiki lub E", Quantity.String, ItemCategory.MeterResult,(w, t, u, f, p) => (w.GetMeterTestRslt(t) != null) ? FormatStr(f, w.GetMeterTestRslt(t).PassedOrErrorFlagsStr())
|
||||
: FormatStr(f, w.PassedOrErrorFlagsStr()))); /// PL specific result
|
||||
|
||||
///
|
||||
/// Water meter info
|
||||
|
||||
@ -29,5 +29,5 @@ using System.Runtime.InteropServices;
|
||||
// Build Number
|
||||
// Revision
|
||||
//
|
||||
[assembly: AssemblyVersion("2.30.1978.0")]
|
||||
[assembly: AssemblyFileVersion("2.30.1978.0")]
|
||||
[assembly: AssemblyVersion("2.30.1980.0")]
|
||||
[assembly: AssemblyFileVersion("2.30.1980.0")]
|
||||
|
||||
@ -1,5 +1,5 @@
|
||||
///
|
||||
/// Copyright (c) 2013-2019 Sensus Slovensko a.s.
|
||||
/// Copyright (c) 2013-2022 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
@ -427,20 +427,6 @@ namespace TBF.Rig.TestMethods.FixedStartMassCollection
|
||||
|
||||
temperature_set:
|
||||
|
||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperations(readTempPressOps)
|
||||
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.FixedStart),
|
||||
test.Qfrom, test.Qto, 2 * totalPulses, 10))
|
||||
.EnterState();
|
||||
do
|
||||
{
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
while (!e.Contains(Event.MeasurementStarted));
|
||||
|
||||
//-----------------------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Stopping_flow_for_the_fixed_start);
|
||||
//-----------------------------------------------------------------
|
||||
@ -456,10 +442,23 @@ namespace TBF.Rig.TestMethods.FixedStartMassCollection
|
||||
while (!e.Contains(Event.ValvesSet));
|
||||
|
||||
|
||||
State.Create(string.Format("{0}({1}) : Starting the test", test.Method, test.Name))
|
||||
.AddOperation(checkUiOp)
|
||||
.AddOperations(readTempPressOps)
|
||||
.AddOperation(cBrd.StartMeasurementOp(outPath, (Elde.TestMethods.Diverter | Elde.TestMethods.FixedStart),
|
||||
test.Qfrom, test.Qto, 2 * totalPulses, 10))
|
||||
.EnterState();
|
||||
do
|
||||
{
|
||||
e = StateMachine.WaitRunDevsRunOps();
|
||||
if (e.Contains(Event.Error)) { retVal = Event.Error; goto stopTest; }
|
||||
if (TestAndLogUiCmdStop(test, e)) { retVal = Event.UiCmdStop; goto stopTest; }
|
||||
}
|
||||
while (!e.Contains(Event.MeasurementStarted));
|
||||
|
||||
int time = StateMachine.Time;
|
||||
double currentFlow = RefFlow.Val;
|
||||
|
||||
|
||||
//------------------------------------------------
|
||||
Bridge.OnActivity(this, Strings.Measuring_the_weight);
|
||||
//------------------------------------------------
|
||||
|
||||
Loading…
Reference in New Issue