Refactorization : BenchControl -> Rig
This commit is contained in:
@@ -0,0 +1,58 @@
|
||||
///
|
||||
/// Copyright (c) 2020 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using log4net;
|
||||
using TBF.Boxes;
|
||||
|
||||
namespace TBF.Rig.Modbus.WaterAnalyzer
|
||||
{
|
||||
public class ReadConductivityOp : IOperation
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(ReadConductivityOp));
|
||||
public override string ToString() { return string.Format("ReadLevelOp(.,.)"); }
|
||||
|
||||
/// Set by the constructor
|
||||
readonly Analyzer analyzer;
|
||||
|
||||
/// Measured value
|
||||
FloatBox conductivity; /// [uS/cm] electrical conductivity of water
|
||||
|
||||
/// <summary>
|
||||
/// Events: LevelDone or Error
|
||||
/// </summary>
|
||||
/// <param name="analyzer">Water level meter reference</param>
|
||||
/// <param name="conduct">Reference to the measured level variable, value is in mm</param>
|
||||
/// <param name="eventDone">Event to be returned by Run() when completed OK</param>
|
||||
public ReadConductivityOp(Analyzer analyzer, ref FloatBox conduct)
|
||||
{
|
||||
if (analyzer == null) throw new ArgumentNullException("analyzer");
|
||||
this.analyzer = analyzer;
|
||||
this.conductivity = conduct;
|
||||
|
||||
log.Debug(this.ToString());
|
||||
}
|
||||
|
||||
|
||||
/// <summary>Start this operation</summary>
|
||||
public void Start()
|
||||
{
|
||||
conductivity.Val = analyzer.ReadConductivity();
|
||||
}
|
||||
|
||||
/// <summary>Run this operation</summary>
|
||||
/// <returns>
|
||||
/// Event.ConductivityDone
|
||||
/// </returns>
|
||||
public Event Run()
|
||||
{
|
||||
conductivity.Val = analyzer.ReadConductivity();
|
||||
return Event.ConductivityDone;
|
||||
}
|
||||
|
||||
/// <summary>Stop this operation</summary>
|
||||
public void Stop()
|
||||
{
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue