/// Copyright (c) 2020 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using log4net;
|
||||
using TBF.Rig.Generic;
|
||||
using TBF.Boxes;
|
||||
using Config.Entities;
|
||||
using System.Diagnostics;
|
||||
|
||||
namespace TBF.Rig.Modbus.WaterAnalyzer
|
||||
{
|
||||
public class Analyzer : ComponentBase, GenericDevices.ITempMeter, IDevice
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(Analyzer));
|
||||
public override string ToString() { return string.Format("Analyzer({0})", Cfg.ToString(1)); }
|
||||
|
||||
readonly AnalyzerCfg myCfg;
|
||||
readonly GenericDevices.IModbus modbus;
|
||||
|
||||
/// <summary>The state of the measurement</summary>
|
||||
MsrmntState msrmntState;
|
||||
|
||||
///
|
||||
/// Measured values when MsrmntState == MsrmntState.Valid
|
||||
///
|
||||
float conductivity; /// [uS/cm] electrical conductivity of water
|
||||
double temperature; /// [°C] water temperature
|
||||
|
||||
public float Conductivity { get { return conductivity; } }
|
||||
|
||||
/// <summary>Measurement time stamp when MsrmntState == MsrmntState.Valid</summary>
|
||||
int msrmntTimeStamp;
|
||||
|
||||
|
||||
public Analyzer()
|
||||
{
|
||||
}
|
||||
|
||||
public Analyzer(Generic.IComponentCfg cfg, IList<Generic.IComponent> components)
|
||||
: base(cfg)
|
||||
{
|
||||
myCfg = cfg as AnalyzerCfg;
|
||||
|
||||
modbus = (GenericDevices.IModbus)TbfComponents.FindComponent(cfg.ParentName, components);
|
||||
if (modbus == null) throw new Exception("Cannot find " + Name + " parent");
|
||||
|
||||
/// Connect to handler
|
||||
//ModbusAddress.MeretRS485Address[Idx0] = ModbusAddress;
|
||||
|
||||
log.Warn(this.ToString());
|
||||
}
|
||||
|
||||
/// <summary>Initialize this device</summary>
|
||||
public void Initialize()
|
||||
{
|
||||
if (myCfg.DebugLevel == DebugMode.Simulate)
|
||||
{
|
||||
conductivity = 0.0F;
|
||||
temperature = 0.0;
|
||||
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
return;
|
||||
}
|
||||
|
||||
msrmntState = MsrmntState.Busy;
|
||||
|
||||
log.FatalFormat("Successfully initialized device {0}", ToString());
|
||||
}
|
||||
|
||||
|
||||
public float ReadConductivity() { return conductivity; } /// Returns electrical conductivity of water in [uS/cm]
|
||||
public double ReadTemperature() { return temperature; } /// Returns water temperature in [°C]
|
||||
|
||||
public ReadConductivityOp ReadConductivityOp(ref FloatBox conduct) { return new ReadConductivityOp(this, ref conduct); }
|
||||
public IOperation ReadTempOp(ref DoubleBox temperature) { return new ReadTempOp(this, ref temperature); }
|
||||
public IOperation ReadTempOp(ref DoubleBox temperature, Event eventDone) { return new ReadTempOp(this, ref temperature, eventDone); }
|
||||
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
public void RunDeviceBefore()
|
||||
{
|
||||
if (myCfg.DebugLevel == Config.Entities.DebugMode.Simulate ||
|
||||
myCfg.DebugLevel == Config.Entities.DebugMode.FailureDuringOperation)
|
||||
{
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
return;
|
||||
}
|
||||
|
||||
if (modbus.ReceivedTelegrams[myCfg.ModbusAddress].Count > 0)
|
||||
{
|
||||
byte[] telegram = modbus.ReceivedTelegrams[myCfg.ModbusAddress].Dequeue();
|
||||
|
||||
if (telegram.Length == 9 && telegram[1] == 3 && telegram[2] == 4)
|
||||
{
|
||||
///
|
||||
/// Telegram with values
|
||||
///
|
||||
byte[] conductBytes = new byte[] { telegram[4], telegram[3], telegram[6], telegram[5] };
|
||||
conductivity = System.BitConverter.ToSingle(conductBytes, 0);
|
||||
UpdateProcessData(conductivity);
|
||||
|
||||
string line = string.Format("conductivity = {0} uS/cm", conductivity);
|
||||
log.Debug(line);
|
||||
Debug.WriteLine(line);
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
byte[] msg = new byte[8]; /// Buffer for data to send
|
||||
|
||||
if ((StateMachine.Time % 10) == 0) /// Each 10 seconds
|
||||
{
|
||||
///
|
||||
/// Send command to request 1 float value in 2 registers at addresses 0x50 and 0x51 from Modbus.WaterAnalyzer
|
||||
///
|
||||
UInt16 regAddr = 0x50;
|
||||
UInt16 count = 2;
|
||||
|
||||
/// Prepare data to be sent
|
||||
msg[0] = myCfg.ModbusAddress;
|
||||
msg[1] = 3; /// CMD =
|
||||
msg[2] = (byte)(regAddr >> 8); /// Control Word Hi
|
||||
msg[3] = (byte)(regAddr & 0xFF); /// Control Word Lo
|
||||
msg[4] = (byte)(count >> 8); /// Serial Com Reference Hi
|
||||
msg[5] = (byte)(count & 0xFF); /// Serial Com Reference Lo
|
||||
|
||||
modbus.SendMessage(msg);
|
||||
}
|
||||
}
|
||||
|
||||
public void RunDeviceAfter() { }
|
||||
public void StopDevice() { }
|
||||
public void StopDevice2() { }
|
||||
|
||||
void UpdateProcessData(float conduct)
|
||||
{
|
||||
TBF.Rig.Sequences.ProcessData.Conductivity.Val = conduct;
|
||||
}
|
||||
}
|
||||
}
|
||||