Refactorization : BenchControl -> Rig

This commit is contained in:
Milan Hanajik
2021-03-05 16:12:24 +01:00
parent 84c8ec26b6
commit 6cf3bd6160
1461 changed files with 6330 additions and 6330 deletions
@@ -0,0 +1,27 @@
///
/// Copyright (c) 2016-2020 Sensus Slovensko a.s.
///
using System.Collections.Generic;
using TBF.Rig.Generic;
namespace TBF.Rig.Modbus.PressureMeter.Meret
{
public class Factory : IComponentFactory
{
public string ClassName { get { return GetType().Namespace.Substring(8); } }
public override string ToString() { return ClassName; }
public void ResetStaticProperties() { PressureMeter.ResetStaticProperties(); }
public IComponent DummyComponent() { return new PressureMeter(); }
public IComponent GetComponent(IComponentCfg cfg, IList<IComponent> components) { return new PressureMeter(cfg, components); }
public IComponentCfg DefaultConfig() { return new PressureMeterCfg(this); }
public IComponentCfg CmpntCfgFromCmpntEntity(Config.Entities.Component component)
{
return ComponentCfgBase.CreateFromDbEntity(PressureMeterCfg.Serializer, component, this);
}
}
}
@@ -0,0 +1,129 @@
///
/// Copyright (c) 2016-2020 Sensus Slovensko a.s.
///
using System;
using System.Collections.Generic;
using log4net;
using SchematicDrawing;
using TBF.Rig.Generic;
using TBF.Boxes;
namespace TBF.Rig.Modbus.PressureMeter.Meret
{
public class PressureMeter : ComponentBase, GenericDevices.IPressureMeter, IDevice, IDrawingItCmpntWithMeasuredVal
{
private static readonly ILog log = LogManager.GetLogger(typeof(PressureMeter));
public override string ToString() { return string.Format("{0}({1})", ClassName, Cfg.ToString(1)); }
readonly PressureMeterCfg pressureMtrCfg;
public IDrawingItem DrawingItem { get { return pressureMtrCfg as IDrawingItem; } }
readonly GenericDevices.IModbus modbus;
double receivedPressure;
public bool MsrmntAvailable { get { return true; } }
public double MeasuredVal { get { return receivedPressure; } }
public string AltString { get { return string.Empty; } }
public PressureMeter() { }
public PressureMeter(Generic.IComponentCfg cfg, IList<Generic.IComponent> components)
: base(cfg)
{
pressureMtrCfg = cfg as PressureMeterCfg;
modbus = (GenericDevices.IModbus)TbfComponents.FindComponent(cfg.ParentName, components);
if (modbus == null) throw new Exception("Cannot find " + Name + " parent");
log.Warn(this.ToString());
}
///
/// IDevice interface
///
public void Initialize() { }
public void RunDeviceBefore()
{
if (pressureMtrCfg.DebugLevel == Config.Entities.DebugMode.Simulate ||
pressureMtrCfg.DebugLevel == Config.Entities.DebugMode.FailureDuringOperation)
{
return;
}
if (modbus.ReceivedTelegrams[pressureMtrCfg.ModbusAddress].Count > 0)
{
byte[] telegram = modbus.ReceivedTelegrams[pressureMtrCfg.ModbusAddress].Dequeue();
if (telegram.Length == 9 && telegram[1] == 4 && telegram[2] == 4)
{
/// Swap byte order
byte t1 = telegram[3];
byte t2 = telegram[4];
byte t3 = telegram[5];
byte t4 = telegram[6];
telegram[3] = t4;
telegram[4] = t3;
telegram[5] = t2;
telegram[6] = t1;
receivedPressure = Config.Units.ConvertFrom(Config.Unit.kPa, System.BitConverter.ToSingle(telegram, 3));
log.WarnFormat("Pressure: {0}={1}bar", Name, receivedPressure.ToString("F3"));
}
}
if ((StateMachine.Time % Constants.ModbusPollPeriod) == (pressureMtrCfg.ModbusAddress % Constants.ModbusPollPeriod)) /// Each 'ModbusDevices' seconds
{
const byte Function = 4; /// Read input registers
const ushort Address = 0; /// Pressure
modbus.SendMessage((byte)pressureMtrCfg.ModbusAddress, Function, Address, 2);
}
}
public void RunDeviceAfter() { }
public void StopDevice() { }
public void StopDevice2() { }
/// <summary>
/// Returns the water pressure
/// </summary>
/// <returns>Pressure in mBar</returns>
public double ReadPressure()
{
if (Cfg.DebugLevel == Config.Entities.DebugMode.Normal)
{
return Config.Formulas.CorrectedValue(receivedPressure, Corrections);
}
else if (Cfg.DebugLevel == Config.Entities.DebugMode.Simulate)
{
return 1.0;
}
else
{
return 0;
}
}
/// <summary>
/// Events: PressureDone, Error
/// </summary>
/// <param name="pressureBox">Reference to a variable for the pressure in Bar</param>
/// <returns>ReadPressureOp instance reference casted to IOperaton</returns>
public IOperation ReadPressureOp(ref DoubleBox pressureBox)
{
return new ReadPressureOp(this, ref pressureBox);
}
/// <summary>
/// Events: pressureDone, Error
/// </summary>
/// <param name="pressureBox">Reference to a variable for the pressure in Bar</param>
/// <param name="pressureDone">Event returned when measurement done</param>
/// <returns>ReadPressureOp instance reference casted to IOperaton</returns>
public IOperation ReadPressureOp(ref DoubleBox pressureBox, Event pressureDone)
{
return new ReadPressureOp(this, ref pressureBox, pressureDone);
}
}
}
@@ -0,0 +1,220 @@
///
/// Copyright (c) 2021 Sensus Slovensko a.s.
///
using System;
using System.Collections.Generic;
using System.Linq;
using System.Xml.Serialization;
using Config;
using Config.Entities;
using SchematicDrawing;
using TBF.Rig.Generic;
namespace TBF.Rig.Modbus.PressureMeter.Meret
{
public class PressureMeterCfg : ComponentCfgBase, IChildComponentCfg, GenericDevices.ICalibInfoCfg, IParamsProvider,
IDrawingItemWithMeasuredVal
{
public static XmlSerializer Serializer = XmlSerializer.FromTypes(new[] { typeof(PressureMeterCfg) })[0];
public override XmlSerializer GetSerializer() { return Serializer; }
public IComponentCfgCtrl GetControl(IList<Config.Entities.Component> cmpntEntities)
{
var parents = cmpntEntities.Where(x => x.ClassName == "Modbus.Common");
return new Configs.ParamsProvider.ComponentCfgCtrl(this, parents);
}
///
/// Serialized parameters
///
public int ModbusAddress; /// 0 (1..254)
public double DefaultPressure; /// 1
public string MsrdFormat { get; set; } /// 2
public Config.Unit MsrdUnit { get; set; } /// 3
public double MsrdValLimLo { get; set; } /// 4
public double MsrdValLimHi { get; set; } /// 5
/// Calibration info serialized parameters displayed in Metrology tab page
public string CalibCertificateNr { get; set; }
public DateTime CalibDate { get; set; }
public DateTime CalibValidDate { get; set; }
/// Schematic drawing info
public Shape Shape { get; set; }
public int X { get; set; }
public int Y { get; set; }
public Sz Sz { get; set; }
public Orient Orient { get; set; }
public bool Flip { get; set; }
public int LblX { get; set; }
public int LblY { get; set; }
public Orient LblOrient { get; set; }
public int MsrdX { get; set; }
public int MsrdY { get; set; }
public Orient MsrdOrient { get; set; }
[XmlIgnore]
public IList<GNode> GNodes { get; set; }
/// Private parameterless constructor invoked by all other (public) constructors
PressureMeterCfg()
{
GNodes = new List<GNode>();
}
public PressureMeterCfg(IComponentFactory factory)
: this()
{
Shape = Shape.PressM;
Sz = Sz.M;
Factory = factory;
Name = "Pr";
ParentName = "Modbus";
InitializeAll();
}
public string ComponentName { get { return Name; } }
public void InitializeAll()
{
ModbusAddress = 49;
DefaultPressure = 2.34;
MsrdFormat = "{0:F2} bar";
MsrdUnit = Config.Unit.bar;
MsrdValLimLo = -0.1;
MsrdValLimHi = 25.0;
MsrdY = 22;
}
string[] paramNames = new string[]
{
"Modbus address", /// 0
"Default pressure", /// 1
"Display format", /// 2
"Unit of pressure", /// 3
"Pressure limit Lo", /// 4
"Pressure limit Hi", /// 5
};
public string ParamName(int i) { return paramNames[i]; }
public int ParamsCount() { return paramNames.Length; }
public ICollection<string> ParamValues(int i)
{
switch (i)
{
case 3:
return new string[] { "Pa", "hPa", "mbar", "kPa", "inHg", "psi", "bar", "MPa" };
default:
return null;
}
}
public string ToString(int i)
{
switch (i)
{
case 0: return ModbusAddress.ToString();
case 1: return DefaultPressure.ToString();
case 2: return MsrdFormat;
case 3: return MsrdUnit.ToString();
case 4: return MsrdValLimLo.ToString();
case 5: return MsrdValLimHi.ToString();
default:
return string.Format("{0}(1) {2}[{3},{4}] addr={5}", Name,
(string.IsNullOrEmpty(ParentName) ? "-" : ParentName), Shape, X, Y, ModbusAddress);
}
}
public CfgUpdateFlags UpdateParam(int i, string str)
{
switch (i)
{
case 0: ModbusAddress = int.Parse(str); return CfgUpdateFlags.RestartRqrd;
case 1: DefaultPressure = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
case 2: MsrdFormat = str; return CfgUpdateFlags.RestartRqrd;
case 3:
foreach (var u in new Unit[] { Unit.Pa, Unit.hPa, Unit.mbar, Unit.kPa, Unit.inHg, Unit.psi, Unit.bar, Unit.MPa })
{
if (str == u.ToString())
{
MsrdUnit = u;
return CfgUpdateFlags.RestartRqrd;
}
}
return CfgUpdateFlags.None;
case 4: MsrdValLimLo = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
case 5: MsrdValLimHi = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
default: return CfgUpdateFlags.None;
}
}
public bool ValidateParam(int i, string str, out string message)
{
message = string.Empty;
int idummy;
double dummy;
switch (i)
{
case 0:
if (int.TryParse(str, out idummy) && idummy >= 1 && idummy <= 254) return true;
break;
case 1:
case 4:
case 5:
if (TBF.Utils.TryParseSDouble(str, out dummy)) return true;
break;
case 2:
return true;
case 3:
if (ParamValues(3).Contains(str)) return true;
break;
default:
message = "Invalid index";
return false;
}
message = ParamName(i) + " is invalid";
return false;
}
void CopyContentTo(PressureMeterCfg prms)
{
prms.ParentName = this.ParentName;
prms.CalibCertificateNr = this.CalibCertificateNr;
prms.CalibDate = this.CalibDate;
prms.CalibValidDate = this.CalibValidDate;
prms.Shape = this.Shape;
prms.Sz = this.Sz;
prms.Orient = this.Orient;
prms.Flip = this.Flip;
prms.LblX = this.LblX;
prms.LblY = this.LblY;
prms.LblOrient = this.LblOrient;
prms.MsrdX = this.MsrdX;
prms.MsrdY = this.MsrdY;
prms.MsrdOrient = this.MsrdOrient;
prms.ModbusAddress = this.ModbusAddress;
prms.DefaultPressure = this.DefaultPressure;
prms.MsrdFormat = this.MsrdFormat;
prms.MsrdUnit = this.MsrdUnit;
prms.MsrdValLimLo = this.MsrdValLimLo;
prms.MsrdValLimHi = this.MsrdValLimHi;
}
public Config.Entities.IParamsProvider Clone()
{
PressureMeterCfg pars = new PressureMeterCfg();
CopyContentTo(pars);
return pars;
}
public bool UpdateEmbeddedDbEntity()
{
return true; /// =OK, do nothing
}
}
}
@@ -0,0 +1,60 @@
///
/// Copyright (c) 2016-2021 Sensus Slovensko a.s.
///
using System;
using log4net;
using TBF.Boxes;
namespace TBF.Rig.Modbus.PressureMeter.Meret
{
public class ReadPressureOp : IOperation
{
private static readonly ILog log = LogManager.GetLogger(typeof(ReadPressureOp));
public override string ToString() { return string.Format("ReadPressureOp(.,{0},.)", eventDone); }
/// Set by the constructor
readonly PressureMeter pressureMeter;
readonly DoubleBox pressure; /// Box for the measured value
readonly Event eventDone;
/// <summary>
/// Events: PressureDone or Error
/// </summary>
/// <param name="pressureMeter">Pressure meter reference</param>
/// <param name="pressure">Reference to the measured pressure variable, value is in bar</param>
/// <param name="eventDone">Event to be returned by Run() when completed OK</param>
public ReadPressureOp(PressureMeter pressureMeter, ref DoubleBox pressure, Event eventDone)
{
if (pressureMeter == null) throw new ArgumentNullException("pressureMeter");
this.pressureMeter = pressureMeter;
this.pressure = pressure;
this.eventDone = eventDone;
log.Debug(this.ToString());
}
public ReadPressureOp(PressureMeter pressureMeter, ref DoubleBox pressure)
: this(pressureMeter, ref pressure, Event.PressureDone)
{
}
/// <summary>Start this operation</summary>
public void Start()
{
if (pressure != null) pressure.Val = pressureMeter.ReadPressure();
}
/// <summary>Run this operation</summary>
/// <returns>
/// Event.PressureInDone or Event.PressureOutDone
/// </returns>
public Event Run()
{
if (pressure != null) pressure.Val = pressureMeter.ReadPressure();
return eventDone;
}
/// <summary>Stop this operation</summary>
public void Stop() { }
}
}