Refactorization : BenchControl -> Rig
This commit is contained in:
@@ -0,0 +1,216 @@
|
||||
///
|
||||
/// Copyright (c) 2017-2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using log4net;
|
||||
using Config;
|
||||
using Config.Entities;
|
||||
using SchematicDrawing;
|
||||
using TBF.Rig.Generic;
|
||||
using TBF.Boxes;
|
||||
|
||||
namespace TBF.Rig.Modbus.Ambient.Comet
|
||||
{
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
/// Connection settings: 9600 Bd 8-bits No-parity 2-stop-bits Flow control: none.
|
||||
/// </summary>
|
||||
public class Ambient : ComponentBase, IDevice, IOperation, GenericDevices.IAmbient, IDrawingItCmpntWithMeasuredVal
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(Ambient));
|
||||
public override string ToString() { return string.Format("Ambient({0})", Cfg.ToString(1)); }
|
||||
|
||||
///
|
||||
/// Configuration and wrappers
|
||||
///
|
||||
readonly AmbientCfg ambientCfg;
|
||||
///
|
||||
Unit TempUnit { get { return ambientCfg.TempUnit; } }
|
||||
double TempLimLo { get { return Units.ConvertFrom(TempUnit, ambientCfg.TempLimLo); } }
|
||||
double TempLimHi { get { return Units.ConvertFrom(TempUnit, ambientCfg.TempLimHi); } }
|
||||
double DefaultTemperature { get { return Units.ConvertFrom(TempUnit, ambientCfg.DefaultTemp); } }
|
||||
///
|
||||
Unit PressureUnit { get { return ambientCfg.PressureUnit; } }
|
||||
double PressureLimLo { get { return Units.ConvertFrom(PressureUnit, ambientCfg.PressureLimLo); } }
|
||||
double PressureLimHi { get { return Units.ConvertFrom(PressureUnit, ambientCfg.PressureLimHi); } }
|
||||
double DefaultPressure { get { return Units.ConvertFrom(PressureUnit, ambientCfg.DefaultPressure); } }
|
||||
///
|
||||
Unit HumiUnit { get { return ambientCfg.HumiUnit; } }
|
||||
double HumiLimLo { get { return Units.ConvertFrom(HumiUnit, ambientCfg.HumiLimLo); } }
|
||||
double HumiLimHi { get { return Units.ConvertFrom(HumiUnit, ambientCfg.HumiLimHi); } }
|
||||
double DefaultHumidity { get { return Units.ConvertFrom(HumiUnit, ambientCfg.DefaultHumi); } }
|
||||
|
||||
///
|
||||
/// IDrawingItCmpntWithMeasuredVal interface
|
||||
///
|
||||
public IDrawingItem DrawingItem { get { return ambientCfg as IDrawingItem; } }
|
||||
///
|
||||
public bool MsrmntAvailable { get { return true; } }
|
||||
public double MeasuredVal { get { return temperature; } }
|
||||
public string AltString
|
||||
{
|
||||
get {
|
||||
return string.Format(ambientCfg.Format, Units.ConvertTo(TempUnit, temperature),
|
||||
Units.ConvertTo(PressureUnit, pressure),
|
||||
Units.ConvertTo(HumiUnit, humidity));
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
readonly GenericDevices.IModbus modbus;
|
||||
|
||||
/// <summary>The state of the measurement</summary>
|
||||
MsrmntState msrmntState;
|
||||
|
||||
///
|
||||
/// Measured values when MsrmntState == MsrmntState.Valid
|
||||
///
|
||||
double temperature; /// [°C]
|
||||
double pressure; /// [bar]
|
||||
double humidity; /// [R%]
|
||||
|
||||
|
||||
/// <summary>Measurement time stamp when MsrmntState == MsrmntState.Valid</summary>
|
||||
int msrmntTimeStamp;
|
||||
|
||||
public Ambient()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
/// </summary>
|
||||
public Ambient(Generic.IComponentCfg cfg, IList<Generic.IComponent> components)
|
||||
: base(cfg)
|
||||
{
|
||||
ambientCfg = cfg as AmbientCfg;
|
||||
|
||||
modbus = (GenericDevices.IModbus)TbfComponents.FindComponent(cfg.ParentName, components);
|
||||
if (modbus == null) throw new Exception("Cannot find " + Name + " parent");
|
||||
|
||||
temperature = DefaultTemperature;
|
||||
pressure = DefaultPressure;
|
||||
humidity = DefaultHumidity;
|
||||
|
||||
log.Warn(this.ToString());
|
||||
}
|
||||
|
||||
public void Initialize()
|
||||
{
|
||||
if (ambientCfg.DebugLevel == DebugMode.Simulate)
|
||||
{
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
return;
|
||||
}
|
||||
|
||||
msrmntState = MsrmntState.Busy;
|
||||
|
||||
log.FatalFormat("Successfully initialized device {0}", ToString());
|
||||
}
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
public void RunDeviceBefore()
|
||||
{
|
||||
if (ambientCfg.DebugLevel == DebugMode.Simulate ||
|
||||
ambientCfg.DebugLevel == DebugMode.FailureDuringOperation)
|
||||
{
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
return;
|
||||
}
|
||||
|
||||
if (modbus.ReceivedTelegrams[ambientCfg.ModbusAddress].Count > 0)
|
||||
{
|
||||
byte[] telegram = modbus.ReceivedTelegrams[ambientCfg.ModbusAddress].Dequeue();
|
||||
|
||||
if (telegram.Length == 13 && telegram[1] == 3 && telegram[2] == 8)
|
||||
{
|
||||
int value = (int)telegram[3] * 256 + (int)telegram[4];
|
||||
temperature = value / 10.0;
|
||||
|
||||
value = (int)telegram[5] * 256 + (int)telegram[6];
|
||||
humidity = value / 10.0;
|
||||
|
||||
value = (int)telegram[9] * 256 + (int)telegram[10];
|
||||
pressure = value / 10000.0;
|
||||
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
|
||||
UpdateProcessData(temperature, pressure, humidity);
|
||||
|
||||
log.InfoFormat("Ambient: temperature = {0:F1} C, humidity = {1:F1} %, pressure = {2:F0} mbar", temperature, humidity, 1000 * pressure);
|
||||
}
|
||||
}
|
||||
|
||||
if ((StateMachine.Time % 10) == (ambientCfg.ModbusAddress % 10)) /// Each 10 seconds
|
||||
{
|
||||
/// Read four registers: 0x31, 0x32, 0x33, 0x34
|
||||
UInt16 regAddr = 0x0030; /// register addr. = 0x31 (Modbus!)
|
||||
UInt16 count = 4;
|
||||
|
||||
/// Prepare data to be sent
|
||||
byte[] msg = new byte[8];
|
||||
msg[0] = (byte)ambientCfg.ModbusAddress;
|
||||
msg[1] = 3; /// CMD = Read registers
|
||||
msg[2] = (byte)(regAddr >> 8); /// Control Word Hi
|
||||
msg[3] = (byte)(regAddr & 0xFF); /// Control Word Lo
|
||||
msg[4] = (byte)(count >> 8); /// Serial Com Reference Hi
|
||||
msg[5] = (byte)(count & 0xFF); /// Serial Com Reference Lo
|
||||
|
||||
modbus.SendMessage(msg);
|
||||
}
|
||||
}
|
||||
|
||||
public void RunDeviceAfter() { }
|
||||
public void StopDevice() { }
|
||||
public void StopDevice2() { }
|
||||
|
||||
void UpdateProcessData(double temperature, double pressure, double humidity)
|
||||
{
|
||||
TBF.Rig.Sequences.ProcessData.AmbTemp.Val = temperature;
|
||||
TBF.Rig.Sequences.ProcessData.AmbPress.Val = pressure;
|
||||
TBF.Rig.Sequences.ProcessData.AmbHumi.Val = humidity;
|
||||
}
|
||||
|
||||
|
||||
///
|
||||
/// Boxes for the operation result
|
||||
///
|
||||
DoubleBox tempBox;
|
||||
DoubleBox pressureBox;
|
||||
DoubleBox humiBox;
|
||||
|
||||
public IOperation ReadAmbientOp(DoubleBox temperature, DoubleBox pressure, DoubleBox humidity)
|
||||
{
|
||||
this.tempBox = temperature;
|
||||
this.pressureBox = pressure;
|
||||
this.humiBox = humidity;
|
||||
return this;
|
||||
}
|
||||
|
||||
/// <summary>Start this operation</summary>
|
||||
public void Start()
|
||||
{
|
||||
if (tempBox != null) tempBox.Val = temperature;
|
||||
if (pressureBox != null) pressureBox.Val = pressure;
|
||||
if (humiBox != null) humiBox.Val = humidity;
|
||||
}
|
||||
|
||||
/// <summary>Run this operation</summary>
|
||||
/// <returns>
|
||||
/// Event.FlowInDone or Event.FlowOutDone
|
||||
/// </returns>
|
||||
public Event Run()
|
||||
{
|
||||
if (tempBox != null) tempBox.Val = temperature;
|
||||
if (pressureBox != null) pressureBox.Val = pressure;
|
||||
if (humiBox != null) humiBox.Val = humidity;
|
||||
return Event.AmbientDone;
|
||||
}
|
||||
|
||||
/// <summary>Stop this operation</summary>
|
||||
public void Stop() { }
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,290 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Linq;
|
||||
using System.Xml.Serialization;
|
||||
using Config;
|
||||
using Config.Entities;
|
||||
using SchematicDrawing;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.Modbus.Ambient.Comet
|
||||
{
|
||||
public class AmbientCfg : ComponentCfgBase, IChildComponentCfg, IParamsProvider, IDrawingItemWithMeasuredVal
|
||||
{
|
||||
public static XmlSerializer Serializer = XmlSerializer.FromTypes(new[] { typeof(AmbientCfg) })[0];
|
||||
public override XmlSerializer GetSerializer() { return Serializer; }
|
||||
|
||||
|
||||
public IComponentCfgCtrl GetControl(IList<Config.Entities.Component> cmpntEntities)
|
||||
{
|
||||
var parents = cmpntEntities.Where(x => x.ClassName == "Modbus.Common");
|
||||
return new Configs.ParamsProvider.ComponentCfgCtrl(this, parents);
|
||||
}
|
||||
|
||||
///
|
||||
/// Serialized parameters
|
||||
///
|
||||
public int ModbusAddress; /// 0 1..254
|
||||
public Unit TempUnit; /// 1
|
||||
public double TempLimLo; /// 2
|
||||
public double TempLimHi; /// 3
|
||||
public double DefaultTemp; /// 4
|
||||
public Unit PressureUnit; /// 5
|
||||
public double PressureLimLo; /// 6
|
||||
public double PressureLimHi; /// 7
|
||||
public double DefaultPressure; /// 8
|
||||
public Unit HumiUnit; /// 9
|
||||
public double HumiLimLo; /// 10
|
||||
public double HumiLimHi; /// 11
|
||||
public double DefaultHumi; /// 12
|
||||
public string Format; /// 13
|
||||
|
||||
/// Schematic drawing info
|
||||
public Shape Shape { get; set; }
|
||||
public int X { get; set; }
|
||||
public int Y { get; set; }
|
||||
public Sz Sz { get; set; }
|
||||
public Orient Orient { get; set; }
|
||||
public bool Flip { get; set; }
|
||||
public int LblX { get; set; }
|
||||
public int LblY { get; set; }
|
||||
public Orient LblOrient { get; set; }
|
||||
public int MsrdX { get; set; }
|
||||
public int MsrdY { get; set; }
|
||||
public Orient MsrdOrient { get; set; }
|
||||
|
||||
[XmlIgnore]
|
||||
public string MsrdFormat { get { return string.Empty; } }
|
||||
[XmlIgnore]
|
||||
public Config.Unit MsrdUnit { get { return TempUnit; } }
|
||||
[XmlIgnore]
|
||||
public double MsrdValLimLo { get { return TempLimLo; } }
|
||||
[XmlIgnore]
|
||||
public double MsrdValLimHi { get { return TempLimHi; } }
|
||||
|
||||
[XmlIgnore]
|
||||
public IList<GNode> GNodes { get; set; }
|
||||
|
||||
/// Private parameterless constructor invoked by all other (public) constructors
|
||||
AmbientCfg()
|
||||
{
|
||||
GNodes = new List<GNode>();
|
||||
Format = string.Empty;
|
||||
}
|
||||
|
||||
public AmbientCfg(IComponentFactory factory)
|
||||
: this()
|
||||
{
|
||||
Shape = Shape.PressM;
|
||||
Sz = Sz.M;
|
||||
Factory = factory;
|
||||
Name = "Ambient";
|
||||
ParentName = "Modbus";
|
||||
InitializeAll();
|
||||
}
|
||||
|
||||
public string ComponentName { get { return Name; } }
|
||||
|
||||
public void InitializeAll()
|
||||
{
|
||||
ModbusAddress = 1;
|
||||
TempUnit = Unit.C;
|
||||
TempLimLo = 15;
|
||||
TempLimHi = 30;
|
||||
DefaultTemp = 25;
|
||||
PressureUnit = Unit.hPa;
|
||||
PressureLimLo = 960;
|
||||
PressureLimHi = 1060;
|
||||
DefaultPressure = 1013;
|
||||
HumiUnit = Unit.RPct;
|
||||
HumiLimLo = 20;
|
||||
HumiLimHi = 80;
|
||||
DefaultHumi = 50;
|
||||
Format = "{0:F1} °C\n{1:F0} hPa\n{2:F0} R%";
|
||||
|
||||
MsrdY = 22;
|
||||
}
|
||||
|
||||
string[] paramNames = new string[]
|
||||
{
|
||||
"Modbus address", /// 0
|
||||
"Unit of temperature", /// 1
|
||||
"Temperature limit Lo", /// 2
|
||||
"Temperature limit Hi", /// 3
|
||||
"Default temperature", /// 4
|
||||
"Unit of pressure", /// 5
|
||||
"Pressure limit Lo", /// 6
|
||||
"Pressure limit Hi", /// 7
|
||||
"Default pressure", /// 8
|
||||
"Unit of rel. humidity", /// 9
|
||||
"Rel. humidity limit Lo", /// 10
|
||||
"Rel. humidity limit Hi", /// 11
|
||||
"Default retl. humidity", /// 12
|
||||
"Display format", /// 13
|
||||
};
|
||||
public string ParamName(int i) { return paramNames[i]; }
|
||||
public int ParamsCount() { return paramNames.Length; }
|
||||
|
||||
public ICollection<string> ParamValues(int i)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 1:
|
||||
return new string[] { "°C", "°F", "K" };
|
||||
case 5:
|
||||
return new string[] { "Pa", "hPa", "mbar", "kPa", "inHg", "psi", "bar", "MPa" };
|
||||
case 9:
|
||||
return new string[] { "R%" };
|
||||
default:
|
||||
return null;
|
||||
}
|
||||
}
|
||||
|
||||
public string ToString(int i)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0: return ModbusAddress.ToString();
|
||||
case 1: return TempUnit.ToDescription();
|
||||
case 2: return TempLimLo.ToString();
|
||||
case 3: return TempLimHi.ToString();
|
||||
case 4: return DefaultTemp.ToString();
|
||||
case 5: return PressureUnit.ToDescription();
|
||||
case 6: return PressureLimLo.ToString();
|
||||
case 7: return PressureLimHi.ToString();
|
||||
case 8: return DefaultPressure.ToString();
|
||||
case 9: return HumiUnit.ToDescription();
|
||||
case 10: return HumiLimLo.ToString();
|
||||
case 11: return HumiLimHi.ToString();
|
||||
case 12: return DefaultHumi.ToString();
|
||||
case 13: return Format.Replace("\n", "<LF>");
|
||||
default:
|
||||
return string.Format("Name={0}, Parent={1}, ModbusAddr={2}", Name,
|
||||
(string.IsNullOrEmpty(ParentName) ? "-" : ParentName), ModbusAddress);
|
||||
}
|
||||
}
|
||||
|
||||
public CfgUpdateFlags UpdateParam(int i, string str)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0: ModbusAddress = int.Parse(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 1:
|
||||
foreach (var u in new Unit[] { Unit.C, Unit.F, Unit.K })
|
||||
{
|
||||
if (str == u.ToDescription()) { TempUnit = u; return CfgUpdateFlags.RestartRqrd; }
|
||||
}
|
||||
return CfgUpdateFlags.None;
|
||||
case 2: TempLimLo = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 3: TempLimHi = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 4: DefaultTemp = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 5:
|
||||
foreach (var u in new Unit[] { Unit.Pa, Unit.hPa, Unit.mbar, Unit.kPa, Unit.inHg, Unit.psi, Unit.bar, Unit.MPa })
|
||||
{
|
||||
if (str == u.ToDescription()) { PressureUnit = u; return CfgUpdateFlags.RestartRqrd; }
|
||||
}
|
||||
return CfgUpdateFlags.None;
|
||||
case 6: PressureLimLo = Utils.ParseUDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 7: PressureLimHi = Utils.ParseUDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 8: DefaultPressure = Utils.ParseUDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 9:
|
||||
foreach (var u in new Unit[] { Unit.RPct })
|
||||
{
|
||||
if (str == u.ToDescription()) { HumiUnit = u; return CfgUpdateFlags.RestartRqrd; }
|
||||
}
|
||||
return CfgUpdateFlags.None;
|
||||
case 10: HumiLimLo = Utils.ParseUDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 11: HumiLimHi = Utils.ParseUDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 12: DefaultHumi = Utils.ParseUDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 13: Format = str.Replace("<LF>", "\n"); return CfgUpdateFlags.RestartRqrd;
|
||||
default: return CfgUpdateFlags.None;
|
||||
}
|
||||
}
|
||||
|
||||
public bool ValidateParam(int i, string str, out string message)
|
||||
{
|
||||
message = string.Empty;
|
||||
int idummy;
|
||||
double dummy;
|
||||
|
||||
switch (i)
|
||||
{
|
||||
case 0:
|
||||
if (int.TryParse(str, out idummy) && idummy >= 1 && idummy <= 254) return true;
|
||||
break;
|
||||
case 1:
|
||||
case 5:
|
||||
case 9:
|
||||
if (ParamValues(i).Contains(str)) return true;
|
||||
break;
|
||||
case 2:
|
||||
case 3:
|
||||
case 4:
|
||||
if (TBF.Utils.TryParseSDouble(str, out dummy)) return true;
|
||||
break;
|
||||
case 6:
|
||||
case 7:
|
||||
case 8:
|
||||
case 10:
|
||||
case 11:
|
||||
case 12:
|
||||
if (TBF.Utils.TryParseUDouble(str, out dummy)) return true;
|
||||
break;
|
||||
case 13:
|
||||
return true;
|
||||
default:
|
||||
message = "Invalid index";
|
||||
return false;
|
||||
}
|
||||
|
||||
message = ParamName(i) + " is invalid";
|
||||
return false;
|
||||
}
|
||||
|
||||
void CopyContentTo(AmbientCfg prms)
|
||||
{
|
||||
prms.ParentName = this.ParentName;
|
||||
|
||||
prms.Shape = this.Shape;
|
||||
prms.Sz = this.Sz;
|
||||
prms.Orient = this.Orient;
|
||||
prms.Flip = this.Flip;
|
||||
prms.LblX = this.LblX;
|
||||
prms.LblY = this.LblY;
|
||||
prms.LblOrient = this.LblOrient;
|
||||
prms.MsrdX = this.MsrdX;
|
||||
prms.MsrdY = this.MsrdY;
|
||||
prms.MsrdOrient = this.MsrdOrient;
|
||||
|
||||
prms.ModbusAddress = this.ModbusAddress;
|
||||
prms.TempUnit = this.TempUnit;
|
||||
prms.TempLimLo = this.TempLimLo;
|
||||
prms.TempLimHi = this.TempLimHi;
|
||||
prms.DefaultTemp = this.DefaultTemp;
|
||||
prms.PressureUnit = this.PressureUnit;
|
||||
prms.PressureLimLo = this.PressureLimLo;
|
||||
prms.PressureLimHi = this.PressureLimHi;
|
||||
prms.DefaultPressure = this.DefaultPressure;
|
||||
prms.HumiUnit = this.HumiUnit;
|
||||
prms.HumiLimLo = this.HumiLimLo;
|
||||
prms.HumiLimHi = this.HumiLimHi;
|
||||
prms.DefaultHumi = this.DefaultHumi;
|
||||
prms.Format = this.Format;
|
||||
}
|
||||
|
||||
public Config.Entities.IParamsProvider Clone()
|
||||
{
|
||||
AmbientCfg pars = new AmbientCfg();
|
||||
CopyContentTo(pars);
|
||||
return pars;
|
||||
}
|
||||
|
||||
public bool UpdateEmbeddedDbEntity()
|
||||
{
|
||||
return true; /// =OK, do nothing
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,27 @@
|
||||
///
|
||||
/// Copyright (c) 2017 Sensus Metering Systems
|
||||
///
|
||||
using System.Collections.Generic;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.Modbus.Ambient.Comet
|
||||
{
|
||||
public class Factory : IComponentFactory
|
||||
{
|
||||
public string ClassName { get { return GetType().Namespace.Substring(8); } }
|
||||
public override string ToString() { return ClassName; }
|
||||
|
||||
public void ResetStaticProperties() { Ambient.ResetStaticProperties(); }
|
||||
|
||||
public IComponent DummyComponent() { return new Ambient(); }
|
||||
|
||||
public IComponent GetComponent(IComponentCfg cfg, IList<IComponent> components) { return new Ambient(cfg, components); }
|
||||
|
||||
public IComponentCfg DefaultConfig() { return new AmbientCfg(this); }
|
||||
|
||||
public IComponentCfg CmpntCfgFromCmpntEntity(Config.Entities.Component component)
|
||||
{
|
||||
return ComponentCfgBase.CreateFromDbEntity(AmbientCfg.Serializer, component, this);
|
||||
}
|
||||
}
|
||||
}
|
||||
Reference in New Issue