/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using log4net;
|
||||
using Dirichlet.Numerics;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public enum ActionID
|
||||
{
|
||||
/// Basic
|
||||
ChangeRoute = 1, /// Change digital outputs (route)
|
||||
MeasureFlow = 2, /// Activate a flow meter to measure the flow
|
||||
SetFlow = 4, /// Set flow
|
||||
StartTest = 8, /// Start a test
|
||||
StopTest = 0x10, /// Stop a test or a flow regulation
|
||||
RegVlvIncrMove = 0x20,
|
||||
RegVlvMoveToPos = 0x40,
|
||||
RegVlvStop = 0x80,
|
||||
SwitchDiverter = 0x100, /// Switch diverter to tank/sink
|
||||
|
||||
/// Advanced
|
||||
GetDiverterTransitionData,
|
||||
GetScopeAnalyzerData,
|
||||
ResetScopeAnalyzer,
|
||||
GetSwitchCounterData,
|
||||
}
|
||||
|
||||
public class Action
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(Action));
|
||||
|
||||
public ActionID ActionId { get; set; }
|
||||
public ulong Route { get; set; } /// ChangeRoute argument
|
||||
public int FlowMId { get; set; } /// SetFlow, MeasureFlow and StartTest argument
|
||||
public int RegVId { get; set; } /// SetFlow and StartTest argument
|
||||
public int DivId { get; set; } /// StartTest and SwitchDiverter argument
|
||||
public bool IsSyncMethod { get; set; } /// StartTest argument
|
||||
public bool IsDivUsed { get; set; } /// StartTest argument
|
||||
public bool ToTank { get; set; } /// SwitchDiverter argument
|
||||
public int TotalPulsesCount { get; set; } /// StartTest argument
|
||||
public int MassPulsesCount { get; set; } /// StartTest argument
|
||||
public RegValveMode RegVMode { get; set; } /// SetFlow, RegVlvIncrMove, RegVlvMoveToPos, RegVlvStop
|
||||
public int RVMovePar1 { get; set; } /// SetFlow, RegVlvIncrMove, RegVlvMoveToPos
|
||||
public int RVMovePar2 { get; set; } /// SetFlow, RegVlvIncrMove, RegVlvMoveToPos
|
||||
public int PID { get; set; } /// SetFlow
|
||||
public int TolerRV { get; set; } /// SetFlow
|
||||
public int StabTime { get; set; } /// SetFlow
|
||||
public int DivThreshold { get; set; } /// StartTest argument
|
||||
int StartStop { get; set; } /// Implicitly used by StartTest and StopTest: -1=not defined, 0=stop, 1=start
|
||||
|
||||
|
||||
public Action()
|
||||
{
|
||||
/// Values -1 indicate the related arguments are not used yet
|
||||
FlowMId = -1;
|
||||
RegVId = -1;
|
||||
DivId = -1;
|
||||
RegVMode = RegValveMode.None;
|
||||
StartStop = -1;
|
||||
|
||||
/// These values are used by one action type only. No conflicts possible
|
||||
Route = 0;
|
||||
TotalPulsesCount = 0;
|
||||
MassPulsesCount = 0;
|
||||
RVMovePar1 = 0;
|
||||
RVMovePar2 = 0;
|
||||
}
|
||||
|
||||
|
||||
public bool IsStart()
|
||||
{
|
||||
return (ActionId & (ActionID.SetFlow | ActionID.StartTest)) != 0;
|
||||
}
|
||||
|
||||
public bool IsStop()
|
||||
{
|
||||
return (ActionId & ActionID.StopTest) != 0;
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action ChangeRoute(ulong route)
|
||||
{
|
||||
return new Action
|
||||
{
|
||||
ActionId = ActionID.ChangeRoute,
|
||||
Route = route,
|
||||
};
|
||||
}
|
||||
void SetChangeRouteArgs(Action action)
|
||||
{
|
||||
Route = action.Route;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedChangeRouteArgs(Action newAction)
|
||||
{
|
||||
return Route == newAction.Route;
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action MeasureFlow(int flowMeterId)
|
||||
{
|
||||
return new Action
|
||||
{
|
||||
ActionId = ActionID.MeasureFlow,
|
||||
FlowMId = flowMeterId,
|
||||
};
|
||||
}
|
||||
void SetMeasureFlowArgs(Action action)
|
||||
{
|
||||
FlowMId = action.FlowMId;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedMeasureFlowArgs(Action newAction)
|
||||
{
|
||||
return (FlowMId == -1 || FlowMId == newAction.FlowMId);
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action SetFlow(int flowMeterId, int regValveId, double freqLo, double freqHi,
|
||||
int pid, int tolerRV, int stabTime)
|
||||
{
|
||||
int rvMovePar1 = Convert.ToInt32(Math.Round(13.1072 * freqLo));
|
||||
int rvMovePar2 = Convert.ToInt32(Math.Round(13.1072 * freqHi));
|
||||
|
||||
return new Action
|
||||
{
|
||||
ActionId = ActionID.SetFlow,
|
||||
FlowMId = flowMeterId,
|
||||
RegVId = regValveId,
|
||||
RegVMode = RegValveMode.TargetFrequency,
|
||||
RVMovePar1 = rvMovePar1,
|
||||
RVMovePar2 = rvMovePar2,
|
||||
PID = pid,
|
||||
TolerRV = tolerRV,
|
||||
StabTime = stabTime,
|
||||
};
|
||||
}
|
||||
void SetSetFlowArgs(Action action)
|
||||
{
|
||||
FlowMId = action.FlowMId;
|
||||
RegVId = action.RegVId;
|
||||
RegVMode = action.RegVMode;
|
||||
RVMovePar1 = action.RVMovePar1;
|
||||
RVMovePar2 = action.RVMovePar2;
|
||||
PID = action.PID;
|
||||
TolerRV = action.TolerRV;
|
||||
StabTime = action.StabTime;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedSetFlowArgs(Action newAction)
|
||||
{
|
||||
return (FlowMId == -1 || FlowMId == newAction.FlowMId) &&
|
||||
(RegVId == -1 || RegVId == newAction.RegVId) &&
|
||||
(RegVMode == RegValveMode.None || RegVMode == newAction.RegVMode) &&
|
||||
(RVMovePar1 == -1 || RVMovePar1 == newAction.RVMovePar1) &&
|
||||
(RVMovePar2 == -1 || RVMovePar2 == newAction.RVMovePar2);
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action StartTest(int flowMId, int divId, int divThreshold, bool isSyncMethod,
|
||||
bool isDivUsed, int totalPulsesCount, int massPulsesCount = -1)
|
||||
{
|
||||
return new Action
|
||||
{
|
||||
ActionId = ActionID.StartTest,
|
||||
FlowMId = flowMId,
|
||||
DivId = divId,
|
||||
DivThreshold = divThreshold,
|
||||
IsSyncMethod = isSyncMethod,
|
||||
IsDivUsed = isDivUsed,
|
||||
TotalPulsesCount = totalPulsesCount,
|
||||
MassPulsesCount = (massPulsesCount == -1) ? totalPulsesCount : massPulsesCount,
|
||||
StartStop = 1,
|
||||
};
|
||||
}
|
||||
void SetStartTestArgs(Action action)
|
||||
{
|
||||
FlowMId = action.FlowMId;
|
||||
DivId = action.DivId;
|
||||
DivThreshold = action.DivThreshold;
|
||||
IsSyncMethod = action.IsSyncMethod;
|
||||
IsDivUsed = action.IsDivUsed;
|
||||
TotalPulsesCount = action.TotalPulsesCount;
|
||||
MassPulsesCount = action.MassPulsesCount;
|
||||
StartStop = 1;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedStartTestArgs(Action newAction)
|
||||
{
|
||||
return (FlowMId == -1 || FlowMId == newAction.FlowMId) &&
|
||||
(DivId == -1 || DivId == newAction.DivId) &&
|
||||
(StartStop == -1 || StartStop == 1);
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action StopTest()
|
||||
{
|
||||
return new Action()
|
||||
{
|
||||
ActionId = ActionID.StopTest,
|
||||
StartStop = 0,
|
||||
};
|
||||
}
|
||||
void SetStopTestArgs(Action action)
|
||||
{
|
||||
StartStop = 0;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedStopTestArgs(Action action)
|
||||
{
|
||||
return (StartStop == -1 || StartStop == 0);
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action RegVlvIncrMove(int regValveId, double timeSec)
|
||||
{
|
||||
int rvMovePar = Math.Abs(Convert.ToInt32(Math.Round(timeSec / 0.050))); /// Step is 50 ms
|
||||
|
||||
return new Action
|
||||
{
|
||||
ActionId = ActionID.RegVlvIncrMove,
|
||||
RegVId = regValveId,
|
||||
RegVMode = (timeSec >= 0) ? RegValveMode.PulseWidth : (RegValveMode.PulseWidth | RegValveMode.NegPulseWidth),
|
||||
RVMovePar1 = rvMovePar,
|
||||
RVMovePar2 = rvMovePar,
|
||||
};
|
||||
}
|
||||
void SetRegVlvIncrMoveArgs(Action action)
|
||||
{
|
||||
RegVId = action.RegVId;
|
||||
RegVMode = action.RegVMode;
|
||||
RVMovePar1 = action.RVMovePar1;
|
||||
RVMovePar2 = action.RVMovePar2;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedRegVlvIncrMoveArgs(Action newAction)
|
||||
{
|
||||
return (RegVId == -1 || RegVId == newAction.RegVId) &&
|
||||
(RegVMode == RegValveMode.None || RegVMode == newAction.RegVMode);
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action RegVlvMoveToPos(int regValveId, double positionLo, double positionHi = -1)
|
||||
{
|
||||
int rvMovePar1, rvMovePar2; /// TODO
|
||||
///
|
||||
if (positionHi < 0)
|
||||
{
|
||||
/// Center position specified, calculate a range
|
||||
rvMovePar1 = 0; // TODO
|
||||
rvMovePar2 = 0; // TODO
|
||||
}
|
||||
else
|
||||
{
|
||||
/// Lower and upper range of position specified
|
||||
rvMovePar1 = 0; // TODO
|
||||
rvMovePar2 = 0; // TODO
|
||||
}
|
||||
|
||||
return new Action
|
||||
{
|
||||
ActionId = ActionID.RegVlvMoveToPos,
|
||||
RegVId = regValveId,
|
||||
RegVMode = RegValveMode.TargetPosition,
|
||||
RVMovePar1 = rvMovePar1,
|
||||
RVMovePar2 = rvMovePar2,
|
||||
};
|
||||
}
|
||||
void SetRegVlvMoveToPosArgs(Action action)
|
||||
{
|
||||
RegVId = action.RegVId;
|
||||
RegVMode = action.RegVMode;
|
||||
RVMovePar1 = action.RVMovePar1;
|
||||
RVMovePar2 = action.RVMovePar2;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedRegVlvMoveToPosArgs(Action newAction)
|
||||
{
|
||||
return (RegVId == -1 || RegVId == newAction.RegVId) &&
|
||||
(RegVMode == RegValveMode.None || RegVMode == newAction.RegVMode);
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action RegVlvStop(int regValveId)
|
||||
{
|
||||
return new Action
|
||||
{
|
||||
ActionId = ActionID.RegVlvStop,
|
||||
RegVId = regValveId,
|
||||
RegVMode = RegValveMode.Stop,
|
||||
RVMovePar1 = 0,
|
||||
RVMovePar2 = 0,
|
||||
};
|
||||
}
|
||||
void SetRegVlvStopArgs(Action action)
|
||||
{
|
||||
RegVId = action.RegVId;
|
||||
RegVMode = action.RegVMode;
|
||||
RVMovePar1 = action.RVMovePar1;
|
||||
RVMovePar2 = action.RVMovePar2;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedRegVlvStopArgs(Action newAction)
|
||||
{
|
||||
return (RegVId == -1 || RegVId == newAction.RegVId) &&
|
||||
(RegVMode == RegValveMode.None || RegVMode == newAction.RegVMode);
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action SwitchDiverter(int divId, bool toTank)
|
||||
{
|
||||
return new Action
|
||||
{
|
||||
ActionId = ActionID.SwitchDiverter,
|
||||
DivId = divId,
|
||||
ToTank = toTank,
|
||||
};
|
||||
}
|
||||
void SetSwitchDiverterArgs(Action action)
|
||||
{
|
||||
DivId = action.DivId;
|
||||
ToTank = action.ToTank;
|
||||
}
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments (true = yes)
|
||||
bool CheckSharedSwitchDiverterArgs(Action action)
|
||||
{
|
||||
return (DivId == -1 || DivId == action.DivId);
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
void SetArgs(Action action)
|
||||
{
|
||||
ActionId |= action.ActionId;
|
||||
|
||||
switch (action.ActionId)
|
||||
{
|
||||
case ActionID.ChangeRoute: SetChangeRouteArgs(action); return;
|
||||
case ActionID.MeasureFlow: SetMeasureFlowArgs(action); return;
|
||||
case ActionID.SetFlow: SetSetFlowArgs(action); return;
|
||||
case ActionID.StartTest: SetStartTestArgs(action); return;
|
||||
case ActionID.StopTest: SetStopTestArgs(action); return;
|
||||
case ActionID.RegVlvIncrMove: SetRegVlvIncrMoveArgs(action); return;
|
||||
case ActionID.RegVlvMoveToPos: SetRegVlvMoveToPosArgs(action); return;
|
||||
case ActionID.RegVlvStop: SetRegVlvStopArgs(action); return;
|
||||
case ActionID.SwitchDiverter: SetSwitchDiverterArgs(action); return;
|
||||
default: return;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Check whether new action arguments are compatible with alredy collected arguments
|
||||
/// </summary>
|
||||
/// <param name="action">Action to be executed together with already collected actions</param>
|
||||
/// <returns>true when compatible</returns>
|
||||
bool CheckSharedArgs(Action action)
|
||||
{
|
||||
switch (action.ActionId)
|
||||
{
|
||||
case ActionID.ChangeRoute: return CheckSharedChangeRouteArgs(action);
|
||||
case ActionID.MeasureFlow: return CheckSharedMeasureFlowArgs(action);
|
||||
case ActionID.SetFlow: return CheckSharedSetFlowArgs(action);
|
||||
case ActionID.StartTest: return CheckSharedStartTestArgs(action);
|
||||
case ActionID.StopTest: return CheckSharedStopTestArgs(action);
|
||||
case ActionID.RegVlvIncrMove: return CheckSharedRegVlvIncrMoveArgs(action);
|
||||
case ActionID.RegVlvMoveToPos: return CheckSharedRegVlvMoveToPosArgs(action);
|
||||
case ActionID.RegVlvStop: return CheckSharedRegVlvStopArgs(action);
|
||||
case ActionID.SwitchDiverter: return CheckSharedSwitchDiverterArgs(action);
|
||||
default: return false;
|
||||
}
|
||||
}
|
||||
|
||||
///----------------------------------------------------------------------------------------------
|
||||
public static Action FetchNonConflictingActions(Queue<Action> queue)
|
||||
{
|
||||
log.Debug("Fetching non conflicting actions:");
|
||||
|
||||
if (queue == null || queue.Count == 0) return null;
|
||||
|
||||
Action resultA = queue.Dequeue();
|
||||
log.Debug(resultA.ToString());
|
||||
|
||||
while (queue.Count > 0)
|
||||
{
|
||||
var peekA = queue.Peek();
|
||||
if ((resultA.ActionId & peekA.ActionId) == 0 && resultA.CheckSharedArgs(peekA) == true)
|
||||
{
|
||||
/// ActionId would not be repeated and arguments are compatible => apply the new action
|
||||
resultA.SetArgs(peekA);
|
||||
log.Debug(peekA.ToString());
|
||||
queue.Dequeue();
|
||||
}
|
||||
else
|
||||
{
|
||||
/// Leave actions in the queue and quit the loop as the next scheduled action is incompatible
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
return resultA;
|
||||
}
|
||||
|
||||
public override string ToString()
|
||||
{
|
||||
string args;
|
||||
switch (ActionId)
|
||||
{
|
||||
case ActionID.ChangeRoute:
|
||||
args = string.Format("Route={0}", Route.ToString("X16"));
|
||||
break;
|
||||
case ActionID.MeasureFlow:
|
||||
args = string.Format("Etalon={0}", FlowMId);
|
||||
break;
|
||||
case ActionID.SetFlow:
|
||||
args = string.Format("Etalon={0} RV={1} Par1={2} Par2={3}", FlowMId, RegVId, RVMovePar1, RVMovePar2);
|
||||
break;
|
||||
case ActionID.StartTest:
|
||||
args = string.Format("Etalon={0} TotalP={1} MassP={2}", FlowMId, TotalPulsesCount, MassPulsesCount);
|
||||
break;
|
||||
case ActionID.RegVlvIncrMove:
|
||||
args = string.Format("Time={0}ms", (RegVMode & RegValveMode.NegPulseWidth) != 0 ? -50 * RVMovePar1 : 50 * RVMovePar1);
|
||||
break;
|
||||
case ActionID.RegVlvMoveToPos:
|
||||
args = string.Format("Position={0}%", 0); /// TODO
|
||||
break;
|
||||
default:
|
||||
args = string.Empty;
|
||||
break;
|
||||
}
|
||||
|
||||
return string.Format(" {0} {1}", ActionId, args);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,59 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class DivTransitionData
|
||||
{
|
||||
public const int MessageLen = 255;
|
||||
public const byte MessageCode = (byte)'K';
|
||||
|
||||
/// Diverter transition data
|
||||
const int samplesCount = 245;
|
||||
int DiverterTime_ms;
|
||||
byte[] CurveRaw;
|
||||
|
||||
DivTransitionData()
|
||||
{
|
||||
CurveRaw = new byte[samplesCount];
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Returns tru when receive data fit the message frame
|
||||
/// </summary>
|
||||
/// <param name="rcvdData">Received data</param>
|
||||
/// <param name="cumulativeSums">Cumulative sums of received data bytes</param>
|
||||
/// <param name="rcvdBytesCount">Received bytes count</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
/// <returns>true when frame fits data</returns>
|
||||
public static bool FrameFitsData(byte[] rcvdData, int[] cumulativeSums, int rcvdBytesCount, int offset)
|
||||
{
|
||||
if (offset + MessageLen > rcvdBytesCount) return false;
|
||||
|
||||
int checksum = cumulativeSums[offset + MessageLen - 3] - cumulativeSums[offset];
|
||||
|
||||
return rcvdData[offset] == Const.STX &&
|
||||
rcvdData[offset + 1] == 0x01 &&
|
||||
rcvdData[offset + 2] == ((MessageLen - 5) & 0xFF) &&
|
||||
rcvdData[offset + 3] == MessageCode &&
|
||||
rcvdData[offset + MessageLen - 2] == (checksum & 0xFF) &&
|
||||
rcvdData[offset + MessageLen - 1] == ((checksum >> 8) & 0xFF);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Proces received data
|
||||
/// </summary>
|
||||
/// <param name="rcvdData">Received data</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
public static DivTransitionData GetData(byte[] rcvdData, int offset)
|
||||
{
|
||||
var data = new DivTransitionData();
|
||||
data.DiverterTime_ms = Const.DivTimeResolution * rcvdData[offset + 4];
|
||||
for (int i = 0; i < samplesCount; i++)
|
||||
{
|
||||
data.CurveRaw[i] = rcvdData[offset + 6 + i];
|
||||
}
|
||||
return data;
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,51 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class Const
|
||||
{
|
||||
public const byte STX = 0x10;
|
||||
public const int WMsCount = 20; /// water meters count
|
||||
public const int ADCsCount = 16; /// ADCs count: feedback from RV-s and diverters
|
||||
public const int RVsCount = 8; /// 0..7
|
||||
public const int FlowmtrsCount = 7; /// ID=1..7, ID=0 ... flowmeters 1,2,3 parallel
|
||||
public const int DivertersCount = 5; /// 1..5
|
||||
public const int DivTimeResolution = 2; /// [ms]
|
||||
public const double TimeResolution = 0.0002; /// [s]
|
||||
}
|
||||
|
||||
|
||||
public enum StatusP : ulong
|
||||
{
|
||||
/// byte 0
|
||||
FlowmtrNrMask = 0x7, /// bits 0,1,2
|
||||
TestInProgress = 0x8, /// bit 3
|
||||
TestCompleted = 0x10, /// bit 4
|
||||
ReadingCounters = 0x20, /// bit 5
|
||||
WaitingForDiverter = 0x40, /// bit 6
|
||||
TestWithDiverter = 0x80, /// bit 7
|
||||
/// byte 1
|
||||
TestWithRefFlowmtr = 0x100, /// bit 8
|
||||
DirectionOfDiverer = 0x200, /// bit 9
|
||||
SynchroMethod = 0x800, /// bit 11
|
||||
WaterMeterCalib = 0x1000, /// bit 12
|
||||
EmgcyStopActive = 0x2000, /// bit 13
|
||||
GateOn = 0x4000, /// bit 14
|
||||
TimeMeasurementEn = 0x8000, /// bit 15
|
||||
/// byte 2
|
||||
FrequencyMeasured = 0x80000, /// bit 19
|
||||
CoaxRegValveBusy = 0x200000, /// bit 21
|
||||
/// byte 3
|
||||
ADCError = 0x80000000, /// bit 31
|
||||
/// byte 4
|
||||
TimeoutOccured = 0x100000000, /// bit 32 (after 40s without communication)
|
||||
MeretAddresses = 0x200000000, /// bit 33
|
||||
ScopeBufferFull = 0x400000000, /// bit 34
|
||||
/// byte 5
|
||||
/// byte 6
|
||||
Flowmtr1Active = 0x1000000000000, /// bit 48
|
||||
Flowmtr2Active = 0x2000000000000, /// bit 49
|
||||
Flowmtr3Active = 0x4000000000000, /// bit 50
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,53 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class ExtremaData
|
||||
{
|
||||
public const int MessageLen = 253;
|
||||
public const byte MessageCode = (byte)'E';
|
||||
|
||||
// TODO: Implement member variables
|
||||
|
||||
ExtremaData()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Returns tru when receive data fit the message frame
|
||||
/// </summary>
|
||||
/// <param name="rcvdData">Received data</param>
|
||||
/// <param name="cumulativeSums">Cumulative sums of received data bytes</param>
|
||||
/// <param name="rcvdBytesCount">Received bytes count</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
/// <returns>true when frame fits data</returns>
|
||||
public static bool FrameFitsData(byte[] rcvdData, int[] cumulativeSums, int rcvdBytesCount, int offset)
|
||||
{
|
||||
if (offset + MessageLen > rcvdBytesCount) return false;
|
||||
|
||||
int checksum = cumulativeSums[offset + MessageLen - 3] - cumulativeSums[offset];
|
||||
|
||||
return rcvdData[offset] == Const.STX &&
|
||||
rcvdData[offset + 1] == 0x01 &&
|
||||
rcvdData[offset + 2] == ((MessageLen - 5) & 0xFF) &&
|
||||
rcvdData[offset + 3] == MessageCode &&
|
||||
rcvdData[offset + MessageLen - 2] == (checksum & 0xFF) &&
|
||||
rcvdData[offset + MessageLen - 1] == ((checksum >> 8) & 0xFF);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Proces received data
|
||||
/// </summary>
|
||||
/// <param name="rcvdData">Received data</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
public static ExtremaData GetData(byte[] rcvdData, int offset)
|
||||
{
|
||||
var data = new ExtremaData();
|
||||
|
||||
// TODO
|
||||
|
||||
return data;
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,27 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System.Collections.Generic;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class Factory : IComponentFactory
|
||||
{
|
||||
public string ClassName { get { return this.GetType().Namespace.Substring(8); } }
|
||||
public override string ToString() { return ClassName; }
|
||||
|
||||
public void ResetStaticProperties() { UniCB.ResetStaticProperties(); }
|
||||
|
||||
public IComponent DummyComponent() { return new UniCB(); }
|
||||
|
||||
public IComponent GetComponent(IComponentCfg cfg, IList<IComponent> components) { return new UniCB(cfg); }
|
||||
|
||||
public IComponentCfg DefaultConfig() { return new UniCBCfg("UniCB", this); }
|
||||
|
||||
public IComponentCfg CmpntCfgFromCmpntEntity(Config.Entities.Component component)
|
||||
{
|
||||
return ComponentCfgBase.CreateFromDbEntity(UniCBCfg.Serializer, component, this);
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,231 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class GeneralData
|
||||
{
|
||||
public const int MessageLen = 303;
|
||||
public const byte MessageCode = (byte)' ';
|
||||
|
||||
/// General data
|
||||
public ulong State; /// bytes 5,6,7,8,9,80,81 = 7 bytes = 56 bits
|
||||
public uint Chyby485;
|
||||
public ulong Vystupy;
|
||||
public uint[] StavDA = new uint[2];
|
||||
public double[] ReferenceFreq = new double[4];
|
||||
public int[] EtPulses = new int[Const.WMsCount + 1]; /// EtPulses[0]=total pulses, EtPulses[1..WMsCount] gated et.pulses for respective WM
|
||||
public int EtPulsesK;
|
||||
public int EtPulses2;
|
||||
public int EtPulses3;
|
||||
public int[] WMeterPuls = new int[Const.WMsCount + 1]; /// WMsCount = 20
|
||||
public double[] ImpulseTime = new double[Const.WMsCount + 1]; /// WMsCount = 20
|
||||
public uint[] RegVStatus = new uint[Const.RVsCount + 1 + 1]; /// RVsCount = 8, posledny rValveStatus[9] je prudovy
|
||||
public float[] RegVMoveTime = new float[Const.RVsCount];
|
||||
public int DivTime;
|
||||
public double Ttime; /// s
|
||||
public double TimeRef; /// s
|
||||
public ulong Vstupy;
|
||||
public Int16[] AnalogInput = new Int16[Const.ADCsCount];
|
||||
public int[] TemperatureRaw = new int[8];
|
||||
|
||||
|
||||
public GeneralData()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Returns tru when receive data fit the message frame
|
||||
/// </summary>
|
||||
/// <param name="data">Received data</param>
|
||||
/// <param name="cumulativeSums">Cumulative sums of received data bytes</param>
|
||||
/// <param name="rcvdBytesCount">Received bytes count</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
/// <returns>true when frame fits data</returns>
|
||||
public static bool FrameFitsData(byte[] data, int[] cumulativeSums, int rcvdBytesCount, int offset)
|
||||
{
|
||||
if (offset + MessageLen > rcvdBytesCount) return false;
|
||||
|
||||
int checksum = cumulativeSums[offset + MessageLen - 3] - cumulativeSums[offset];
|
||||
|
||||
return data[offset] == Const.STX &&
|
||||
data[offset + 1] == 0x01 &&
|
||||
data[offset + 2] == ((MessageLen - 5) & 0xFF) &&
|
||||
data[offset + 3] == MessageCode &&
|
||||
data[offset + MessageLen - 2] == (checksum & 0xFF) &&
|
||||
data[offset + MessageLen - 1] == ((checksum >> 8) & 0xFF);
|
||||
}
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Auxiliary functions
|
||||
/// </summary>
|
||||
/// <param name="data">Received data</param>
|
||||
/// <param name="offs">Offset to the files</param>
|
||||
/// <returns></returns>
|
||||
Int16 GetInt16(byte[] data, int offs) { return BitConverter.ToInt16(data, offs); }
|
||||
UInt16 GetUInt16(byte[] data, int offs) { return BitConverter.ToUInt16(data, offs); }
|
||||
UInt32 GetUInt24(byte[] data, int offs) { return BitConverter.ToUInt32(data, offs) & 0x00FFFFFF; }
|
||||
UInt32 GetUInt32(byte[] data, int offs) { return BitConverter.ToUInt32(data, offs); }
|
||||
UInt64 GetUInt40(byte[] data, int offs) { return BitConverter.ToUInt64(data, offs) & 0x000000FFFFFFFFFF; }
|
||||
UInt64 GetUInt64(byte[] data, int offs) { return BitConverter.ToUInt64(data, offs); }
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Proces received data
|
||||
/// </summary>
|
||||
/// <param name="data">Received data</param>
|
||||
/// <param name="offs">Offset of the message</param>
|
||||
public void UpdateData(byte[] data, int offs)
|
||||
{
|
||||
State = GetUInt40(data, offs + (int)Poz.State) | /// Byte 5,6,7,8,9,80,81
|
||||
((ulong)data[offs + (int)Poz.Stat5] << 40) |
|
||||
((ulong)data[offs + (int)Poz.Stat6] << 48);
|
||||
|
||||
Vystupy = GetUInt64(data, offs + (int)Poz.Vyst); /// Byte 10 .. 17
|
||||
StavDA[1] = GetUInt16(data, offs + (int)Poz.SDA2); /// Byte 18,19
|
||||
Vstupy = GetUInt40(data, offs + (int)Poz.Vst); /// Byte 20,21,22,23,24
|
||||
|
||||
/// A/D converters: Feedback from RV-s and diverters
|
||||
for (int i = 0; i < Const.ADCsCount; i++) /// Byte 25 .. 56
|
||||
{
|
||||
#if DEBUG
|
||||
AnalogInput[Const.ADCsCount - 1 - i] = (short)(11 * (15 - i));
|
||||
#else
|
||||
AnalogInput[Const.ADCsCount - 1 - i] = GetInt16(data, offs + (int)Poz.Analogy + 2 * i);
|
||||
#endif
|
||||
}
|
||||
|
||||
/// Groch temperature meters
|
||||
for (int i = 0; i < 8; i++) /// byte 57 .. 72
|
||||
{
|
||||
TemperatureRaw[i] = GetInt16(data, offs + (int)Poz.Groch + 2 * i);
|
||||
}
|
||||
|
||||
EtPulses[0] = Convert.ToInt32(GetUInt24(data, offs + (int)Poz.Et1));/// Byte 73,74,75
|
||||
EtPulsesK = Convert.ToInt32(GetUInt24(data, offs + (int)Poz.EtK)); /// Byte 76,77,78
|
||||
byte spare1 = data[offs + (int)Poz.spare1]; /// byte 79
|
||||
byte spare2 = data[offs + (int)Poz.spare2]; /// byte 82
|
||||
|
||||
for (int i = 0; i < Const.RVsCount; i++) /// Byte 83 .. 90
|
||||
{
|
||||
RegVStatus[i + 1] = ((uint)data[offs + (int)Poz.RVs + i] >> 3) & 7;
|
||||
}
|
||||
/// 4-20 mA reg. valve
|
||||
uint stavRegQ = (uint)((State >> 16) & 0xFF);
|
||||
RegVStatus[Const.RVsCount + 1] = (stavRegQ >> 4) & 2;
|
||||
|
||||
/// This must preceed processing bytes 91 .. 250 as Ttime is used there
|
||||
uint ttimeRaw = GetUInt32(data, offs + (int)Poz.Ttime); /// Byte 251,252,253,254
|
||||
Ttime = Convert.ToDouble(ttimeRaw) * Const.TimeResolution; /// convert to [s]
|
||||
ImpulseTime[0] = Ttime;
|
||||
|
||||
/// Water meters (pulses count, gated test time, gated etalon pulses count)
|
||||
int ix1 = offs + (int)Poz.CT1; /// Byte 91 .. 250
|
||||
int ix2 = offs + (int)Poz.CTR1;
|
||||
for (int wmNr = 1; wmNr <= Const.WMsCount; wmNr++, ix1 += 6, ix2 += 2)
|
||||
{
|
||||
if ((State & (ulong)StatusP.SynchroMethod) != 0)
|
||||
{
|
||||
ushort pulses = GetUInt16(data, ix2);
|
||||
WMeterPuls[wmNr] = Convert.ToInt32(pulses);
|
||||
EtPulses[wmNr] = (pulses == 0) ? 0 : Convert.ToInt32(GetUInt24(data, ix1));
|
||||
ImpulseTime[wmNr] = (pulses == 0) ? 0 : Const.TimeResolution * Convert.ToDouble(GetUInt24(data, ix1 + 3));
|
||||
}
|
||||
else
|
||||
{
|
||||
WMeterPuls[wmNr] = Convert.ToInt32(GetUInt24(data, ix1));
|
||||
EtPulses[wmNr] = EtPulses[0];
|
||||
ImpulseTime[wmNr] = Ttime;
|
||||
}
|
||||
}
|
||||
|
||||
StavDA[0] = GetUInt16(data, offs + (int)Poz.SDA); /// Byte 255,256
|
||||
byte spare3 = data[offs + (int)Poz.spare3]; /// Byte 257
|
||||
|
||||
/// Impulzy perioda (???)
|
||||
uint[] par1 = new uint[3];
|
||||
uint[] par2 = new uint[3];
|
||||
par2[0] = GetUInt16(data, offs + (int)Poz.Per1); /// Byte 258,259
|
||||
par1[0] = GetUInt16(data, offs + (int)Poz.Per1 + 2); /// Byte 260,261
|
||||
par2[1] = GetUInt16(data, offs + (int)Poz.Per2); /// Byte 262.263
|
||||
par1[1] = GetUInt16(data, offs + (int)Poz.Per2 + 2); /// Byte 264,265
|
||||
par2[2] = GetUInt16(data, offs + (int)Poz.Per3); /// Byte 266,267
|
||||
par1[2] = GetUInt16(data, offs + (int)Poz.Per3 + 2); /// Byte 268,269
|
||||
///
|
||||
ReferenceFreq[0] = (par2[0] != 0) ? (5.0f * par1[0] / par2[0]) : 0.0f;
|
||||
ReferenceFreq[1] = ReferenceFreq[2] = ReferenceFreq[3] = 0;
|
||||
///
|
||||
if ((State & (ulong)StatusP.TestWithRefFlowmtr) != 0 && (State & (ulong)StatusP.FlowmtrNrMask) == 0)
|
||||
{
|
||||
/// Measurement with parallel flowmeters
|
||||
if ((State & (ulong)StatusP.Flowmtr1Active) != 0)
|
||||
{
|
||||
ReferenceFreq[1] = ReferenceFreq[0];
|
||||
}
|
||||
|
||||
if ((State & (ulong)StatusP.Flowmtr2Active) != 0)
|
||||
{
|
||||
ReferenceFreq[2] = (par2[1] != 0) ? (5.0f * par1[1] / par2[1]) : 0.0f;
|
||||
}
|
||||
|
||||
if ((State & (ulong)StatusP.Flowmtr3Active) != 0)
|
||||
{
|
||||
ReferenceFreq[3] = (par2[2] != 0) ? (5.0f * par1[2] / par2[2]) : 0.0f;
|
||||
}
|
||||
|
||||
ReferenceFreq[0] = ReferenceFreq[1] + ReferenceFreq[2] + ReferenceFreq[3];
|
||||
}
|
||||
|
||||
DivTime = Const.DivTimeResolution * data[offs + (int)Poz.CasKl]; /// Byte 271
|
||||
byte spare4 = data[offs + (int)Poz.spare4]; /// Byte 272
|
||||
Chyby485 = GetUInt16(data, offs + (int)Poz.Chyb485); /// Byte 273, 274 !!!!!!!!!!!!!!!
|
||||
uint timeRefRaw = GetUInt24(data, offs + (int)Poz.Tim2); /// Byte 274,275,276 !!!!!!!!!!!!!!!
|
||||
TimeRef = Convert.ToDouble(timeRefRaw) / 1000.0; /// convert to [s]
|
||||
|
||||
for (int i = 0; i < Const.RVsCount; i++) /// Byte 278 .. 293
|
||||
{
|
||||
RegVMoveTime[i] = 10 * GetUInt16(data, offs + (int)Poz.CasKoh + 2*i);
|
||||
}
|
||||
|
||||
EtPulses2 = Convert.ToInt32(GetUInt24(data, offs + (int)Poz.ETX2)); /// Byte 294,295,296
|
||||
EtPulses3 = Convert.ToInt32(GetUInt24(data, offs + (int)Poz.ETX3)); /// Byte 297,298.299 !!!!!!!!!!!!!!!
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Byte positions in rcvdData buffer
|
||||
/// </summary>
|
||||
public enum Poz : int
|
||||
{
|
||||
State = 5, /// 5 .. 9
|
||||
Vyst = State + 5, /// 10 .. 17
|
||||
SDA2 = Vyst + 8, /// 18,19
|
||||
Vst = SDA2 + 2, /// 20 .. 24
|
||||
Analogy = Vst + 5, /// 25 .. 56
|
||||
Groch = Analogy + 2 * Const.ADCsCount, /// 57 (16 analog inputs)
|
||||
Et1 = Groch + 16, /// 73,74,75
|
||||
EtK = Et1 + 3, /// 76,77,78
|
||||
spare1 = EtK + 3, /// 79
|
||||
Stat5 = spare1 + 1, /// 80
|
||||
Stat6 = Stat5 + 1, /// 81
|
||||
spare2 = Stat6 + 1, /// 82
|
||||
RVs = spare2 + 1, /// 83
|
||||
CT1 = RVs + 8, /// 91
|
||||
CTR1 = CT1 + 6 * Const.WMsCount, /// 211
|
||||
Ttime = CTR1 + 2 * Const.WMsCount, /// 251
|
||||
SDA = Ttime + 4, /// 255
|
||||
spare3 = SDA + 2, /// 257
|
||||
Per1 = spare3 + 1, /// 258
|
||||
Per2 = Per1 + 4, /// 262
|
||||
Per3 = Per2 + 4, /// 266
|
||||
CasKl = Per3 + 5, /// 271
|
||||
spare4 = CasKl + 1, /// 272
|
||||
Chyb485 = spare4 + 1, /// 273
|
||||
Tim2 = Chyb485 + 1, /// 274
|
||||
CasKoh = Tim2 + 4, /// 278
|
||||
ETX2 = CasKoh + 2 * Const.RVsCount, /// 294
|
||||
ETX3 = ETX2 + 3, /// 297
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,186 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Diagnostics;
|
||||
using Dirichlet.Numerics;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public static class OutputMessage
|
||||
{
|
||||
public const int PayloadLen = 38;
|
||||
public const byte MessageCode = (byte)' ';
|
||||
|
||||
public static byte[] GetMessage(Action action, short config)
|
||||
{
|
||||
byte[] message = new byte[PayloadLen + 5]; /// headed 3 bytes, checksum 2 bytes
|
||||
|
||||
/// Header + message code (4 bytes)
|
||||
message[0] = Const.STX;
|
||||
message[1] = 1; /// Control board addres
|
||||
message[2] = (byte)PayloadLen; /// Payload length
|
||||
message[3] = MessageCode;
|
||||
|
||||
/// Command
|
||||
message[4] = GetCommand(action);
|
||||
message[5] = action.IsStart() ? GetStartParams(action) : action.IsStop() ? GetStopParams(action) : (byte)0;
|
||||
message[6] = (action.DivId <= 0) ? (byte)0 : (byte)(action.DivId - 1);
|
||||
|
||||
int totalPulsesCount = (action.TotalPulsesCount < 0) ? 0 : action.TotalPulsesCount;
|
||||
message[7] = (byte)(totalPulsesCount & 0xFF);
|
||||
message[8] = (byte)((totalPulsesCount >> 8) & 0xFF);
|
||||
message[9] = (byte)((totalPulsesCount >> 16) & 0xFF);
|
||||
|
||||
int massPulsesCount = (action.MassPulsesCount < 0) ? 0 : action.MassPulsesCount;
|
||||
message[10] = (byte)(massPulsesCount & 0xFF);
|
||||
message[11] = (byte)((massPulsesCount >> 8) & 0xFF);
|
||||
message[12] = (byte)((massPulsesCount >> 16) & 0xFF);
|
||||
|
||||
message[13] = 0;
|
||||
|
||||
message[14] = (byte)(config & 0xff);
|
||||
message[15] = (byte)((config >> 8) & 0xff);
|
||||
|
||||
/// Route
|
||||
message[16] = ((action.ActionId & ActionID.ChangeRoute) != 0) ? (byte)1 : (byte)0; /// Route change flag
|
||||
message[17] = (byte)(action.Route & 0xFF);
|
||||
message[18] = (byte)((action.Route >> 8) & 0xFF);
|
||||
message[19] = (byte)((action.Route >> 16) & 0xFF);
|
||||
message[20] = (byte)((action.Route >> 24) & 0xFF);
|
||||
message[21] = (byte)((action.Route >> 32) & 0xFF);
|
||||
message[22] = (byte)((action.Route >> 40) & 0xFF);
|
||||
message[23] = (byte)((action.Route >> 48) & 0xFF);
|
||||
message[24] = (byte)((action.Route >> 56) & 0xFF);
|
||||
|
||||
/// DA2
|
||||
message[25] = 0;
|
||||
message[26] = 0;
|
||||
|
||||
/// Regulation valve
|
||||
message[27] = (action.RegVId < 0) ? (byte)0 : (byte)(action.RegVId | (int)action.RegVMode);
|
||||
message[28] = (byte)(action.RVMovePar1 & 0xFF);
|
||||
message[29] = (byte)((action.RVMovePar1 >> 8) & 0xFF);
|
||||
message[30] = (byte)(action.RVMovePar2 & 0xFF);
|
||||
message[31] = (byte)((action.RVMovePar2 >> 8) & 0xFF);
|
||||
message[32] = action.IsStop() ? (byte)0x20 : action.IsStart() ? (byte)0x42 : (byte)0; /// ZStavReg
|
||||
|
||||
/// DA1
|
||||
message[33] = 0; /// PrudParL
|
||||
message[34] = 0; /// PrudParH
|
||||
|
||||
message[35] = (byte)Math.Max(1, Math.Min(255, action.PID)); /// PIDRV
|
||||
message[36] = (byte)Math.Max(4, Math.Min(255, action.TolerRV)); /// TolerRV (4..20 mA reg.valve only)
|
||||
message[37] = (byte)Math.Max(0, Math.Min(255, action.StabTime)); /// StabRV
|
||||
message[38] = (byte)((action.DivThreshold >> 2) & 0xFF); /// HranAK
|
||||
|
||||
message[39] = 0;
|
||||
message[40] = 0;
|
||||
Debug.Assert(40 == PayloadLen + 2);
|
||||
|
||||
/// Checksum (2 bytes)
|
||||
int checksum = 0;
|
||||
for (int i = 1; i < PayloadLen + 3; i++) checksum += message[i];
|
||||
message[PayloadLen + 3] = (byte)(checksum & 0xFF);
|
||||
message[PayloadLen + 4] = (byte)((checksum >> 8) & 0xFF);
|
||||
|
||||
return message;
|
||||
}
|
||||
|
||||
|
||||
static byte GetCommand(Action action)
|
||||
{
|
||||
int command = 0;
|
||||
if (action.IsStart()) command |= (int)Command.Start;
|
||||
if (action.IsStop()) command |= (int)Command.Stop;
|
||||
return (byte)command;
|
||||
}
|
||||
|
||||
static byte GetStartParams(Action action)
|
||||
{
|
||||
int param = action.FlowMId & (int)StartParam.EtalonMask;
|
||||
|
||||
if (action.IsDivUsed)
|
||||
param |= (int)StartParam.DiverterStart;
|
||||
|
||||
if (action.IsSyncMethod)
|
||||
param |= (int)StartParam.SynchroMethod;
|
||||
else
|
||||
param |= (int)StartParam.StartStopMethod;
|
||||
|
||||
return (byte)param;
|
||||
}
|
||||
|
||||
static byte GetStopParams(Action action)
|
||||
{
|
||||
int param = 0;
|
||||
return (byte)param;
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
public enum Command : byte
|
||||
{
|
||||
RequestData = 0,
|
||||
Start = 1,
|
||||
Stop = 2,
|
||||
GetDiverterTransitionData = 4,
|
||||
GetScopeAnalyzerData = 7,
|
||||
ResetScopeAnalyzer = 8,
|
||||
GetSwitchCounterData = 9,
|
||||
}
|
||||
|
||||
public enum StartParam : byte
|
||||
{
|
||||
EtalonMask = 0x07,
|
||||
DiverterStart = 0x08,
|
||||
SynchroMethod = 0x10,
|
||||
DirectGateStart = 0x20, /// ???
|
||||
StartStopMethod = 0x40,
|
||||
CalibrationMode = 0x80,
|
||||
}
|
||||
|
||||
public enum StopDevs : byte
|
||||
{
|
||||
None = 0,
|
||||
Reference = 0x01, /// bit 0
|
||||
Diverter = 0x02, /// bit 1
|
||||
GatePulse = 0x08, /// bit 3
|
||||
TimeMeasurement = 0x10, /// bit 4
|
||||
BypassDevCoupled2Div = 0x20, /// bit 5
|
||||
RegValveRegulation = 0x80, /// bit 7
|
||||
All = 0xFF,
|
||||
}
|
||||
|
||||
public enum TestMethods
|
||||
{
|
||||
Diverter = 0x01, /// bit 0: 1=Mass method (diverters are used), 0=Volume method
|
||||
FixedStart = 0x02, /// bit 1: 1=fixed start method, 0=flying start method
|
||||
Synchro = 0x04, /// bit 2: 1=Synchro method, 0=Pulse counting
|
||||
MassAndContinue = 0x10, /// bit 4: 1=Method with mass measurement followed by a volume method
|
||||
}
|
||||
|
||||
public enum ValveChgFlag : byte
|
||||
{
|
||||
DoNotChange = 0,
|
||||
Change = 1,
|
||||
SendPressureMeterAddresses = 2,
|
||||
}
|
||||
|
||||
public enum RegValveMode : byte
|
||||
{
|
||||
None = 0,
|
||||
TargetFrequency = 0x10, /// Low and high frequency limits (0..2000Hz,0..2200Hz) are specified
|
||||
TargetPosition = 0x20, /// Low and high position (=DAC value) limits (0..100%) are specified
|
||||
Stop = 0x30, /// Stop regulation
|
||||
PulseWidth = 0x40, /// Pulse width 0.05 .. 2 sec. ... opening and closing (opening=0x40, closing=0xC0)
|
||||
NegPulseWidth = 0x80, /// Pulse width 0.05 .. 2 sec. ... closing (closing=0xC0)
|
||||
}
|
||||
|
||||
public enum RegValveState : byte
|
||||
{
|
||||
Idle = 0,
|
||||
PwOrFreqRegul = 2,
|
||||
DacValueRegul = 3,
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,57 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class ScopeAnalyzerData
|
||||
{
|
||||
public const int MessageLen = 1033;
|
||||
public const byte MessageCode = (byte)'S';
|
||||
|
||||
/// Scope analyzer data
|
||||
public int KonSc;
|
||||
public int ZacSc;
|
||||
|
||||
ScopeAnalyzerData()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Returns tru when receive data fit the message frame
|
||||
/// </summary>
|
||||
/// <param name="rcvdData">Received data</param>
|
||||
/// <param name="cumulativeSums">Cumulative sums of received data bytes</param>
|
||||
/// <param name="rcvdBytesCount">Received bytes count</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
/// <returns>true when frame fits data</returns>
|
||||
public static bool FrameFitsData(byte[] rcvdData, int[] cumulativeSums, int rcvdBytesCount, int offset)
|
||||
{
|
||||
if (offset + MessageLen > rcvdBytesCount) return false;
|
||||
|
||||
int checksum = cumulativeSums[offset + MessageLen - 3] - cumulativeSums[offset];
|
||||
|
||||
return rcvdData[offset] == Const.STX &&
|
||||
rcvdData[offset + 1] == 0x01 &&
|
||||
rcvdData[offset + 2] == ((MessageLen - 5) & 0xFF) &&
|
||||
rcvdData[offset + 3] == MessageCode &&
|
||||
rcvdData[offset + MessageLen - 2] == (checksum & 0xFF) &&
|
||||
rcvdData[offset + MessageLen - 1] == ((checksum >> 8) & 0xFF);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Proces received data
|
||||
/// </summary>
|
||||
/// <param name="rcvdData">Received data</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
public static ScopeAnalyzerData GetData(byte[] rcvdData, int offset)
|
||||
{
|
||||
var data = new ScopeAnalyzerData();
|
||||
|
||||
data.KonSc = Convert.ToInt32(rcvdData[4]) + 256 * Convert.ToInt32(rcvdData[5]);
|
||||
data.ZacSc = Convert.ToInt32(rcvdData[6]) + 256 * Convert.ToInt32(rcvdData[7]);
|
||||
|
||||
return data;
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,53 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class SwitchCountersData
|
||||
{
|
||||
public const int MessageLen = 303;
|
||||
public const byte MessageCode = (byte)'C';
|
||||
|
||||
// TODO: Implement member variables
|
||||
|
||||
SwitchCountersData()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Returns tru when receive data fit the message frame
|
||||
/// </summary>
|
||||
/// <param name="rcvdData">Received data</param>
|
||||
/// <param name="cumulativeSums">Cumulative sums of received data bytes</param>
|
||||
/// <param name="rcvdBytesCount">Received bytes count</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
/// <returns>true when frame fits data</returns>
|
||||
public static bool FrameFitsData(byte[] rcvdData, int[] cumulativeSums, int rcvdBytesCount, int offset)
|
||||
{
|
||||
if (offset + MessageLen > rcvdBytesCount) return false;
|
||||
|
||||
int checksum = cumulativeSums[offset + MessageLen - 3] - cumulativeSums[offset];
|
||||
|
||||
return rcvdData[offset] == Const.STX &&
|
||||
rcvdData[offset + 1] == 0x01 &&
|
||||
rcvdData[offset + 2] == ((MessageLen - 5) & 0xFF) &&
|
||||
rcvdData[offset + 3] == MessageCode &&
|
||||
rcvdData[offset + MessageLen - 2] == (checksum & 0xFF) &&
|
||||
rcvdData[offset + MessageLen - 1] == ((checksum >> 8) & 0xFF);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Proces received data
|
||||
/// </summary>
|
||||
/// <param name="rcvdData">Received data</param>
|
||||
/// <param name="offset">Offset of the message</param>
|
||||
public static SwitchCountersData GetData(byte[] rcvdData, int offset)
|
||||
{
|
||||
var data = new SwitchCountersData();
|
||||
|
||||
// TODO
|
||||
|
||||
return data;
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,596 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Diagnostics;
|
||||
using System.IO.Ports;
|
||||
using System.Text;
|
||||
using log4net;
|
||||
using Common;
|
||||
using Config.Entities;
|
||||
using Dirichlet.Numerics;
|
||||
using TBF.Rig.GenericDevices;
|
||||
using TBF.Rig.Sequences;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
public class UniCB : ComponentBase, IControlBoard, SchematicDrawing.IDrawingItCmpntWithMeasuredVal
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(UniCB));
|
||||
public override string ToString() { return string.Format("CBoard({0})", cbCfg != null ? cbCfg.ToString(1) : string.Empty); }
|
||||
|
||||
/// TBF component configuration and useful wrappers
|
||||
readonly UniCBCfg cbCfg;
|
||||
string comPort { get { return string.Format("COM{0}", cbCfg.ComPortNr); } }
|
||||
short config { get { return (short)((cbCfg.DrainValvesCount << 8) + ((cbCfg.DivertersCount - 1) << 3) + cbCfg.RegValvesCount - 4); } }
|
||||
|
||||
/// IDrawingItCmpnt interface implementation
|
||||
public SchematicDrawing.IDrawingItem DrawingItem { get { return cbCfg as SchematicDrawing.IDrawingItem; } }
|
||||
|
||||
public bool MsrmntAvailable { get { return true; } }
|
||||
public double MeasuredVal { get { return 0; } }
|
||||
|
||||
StringBuilder altString = new StringBuilder();
|
||||
public string AltString
|
||||
{
|
||||
get {
|
||||
altString.Clear();
|
||||
altString.AppendFormat("DI: {0}\n", ToBin40(DigitalInputs));
|
||||
altString.AppendFormat("DO: {0}\n", ToBin40((UInt64)Route));
|
||||
altString.AppendFormat("AD 0:{0:D4} 1:{1:D4} 2:{2:D4} 3:{3:D4} 4:{4:D4} 5:{5:D4}\n",
|
||||
AnalogInput(0), AnalogInput(1), AnalogInput(2), AnalogInput(3), AnalogInput(4), AnalogInput(5));
|
||||
altString.AppendFormat("AD 8:{0:D4} 9:{1:D4} 10:{2:D4} 11:{3:D4}",
|
||||
AnalogInput(8), AnalogInput(9), AnalogInput(10), AnalogInput(11));
|
||||
return altString.ToString();
|
||||
}
|
||||
}
|
||||
|
||||
string ToBin40(UInt64 val)
|
||||
{
|
||||
return string.Format("{0}-{1}-{2}-{3}-{4}", ToBin8((val >> 32) & 0xFF), ToBin8((val >> 24) & 0xFF),
|
||||
ToBin8((val >> 16) & 0xFF), ToBin8((val >> 8) & 0xFF), ToBin8(val & 0xFF));
|
||||
}
|
||||
|
||||
string ToBin8(UInt64 val)
|
||||
{
|
||||
string str = Convert.ToString((byte)val, 2);
|
||||
switch (str.Length)
|
||||
{
|
||||
case 1: return "0000000" + str;
|
||||
case 2: return "000000" + str;
|
||||
case 3: return "00000" + str;
|
||||
case 4: return "0000" + str;
|
||||
case 5: return "000" + str;
|
||||
case 6: return "00" + str;
|
||||
case 7: return "0" + str;
|
||||
default: return str;
|
||||
}
|
||||
}
|
||||
|
||||
/// Uni CB state
|
||||
UInt32 currentOutputs;
|
||||
bool outputsInitialized;
|
||||
DateTime lastOutputsChange;
|
||||
int lastStateMachineTime = 0;
|
||||
|
||||
|
||||
/// Propagated from configurations of other components
|
||||
UInt128 benchModelRoute;
|
||||
UInt128 valvesToInvert; /// Route = valesToInvert ^ RequiredRouteWithoutInvertedVlaves
|
||||
readonly UInt128 routeMask; /// This mask masks out virtual valves, routeMask is set in the constructor
|
||||
|
||||
/// Serial communication
|
||||
SerialPort serialPort; /// Seral port or null: Check serialPort.IsOpen before using the serial port
|
||||
const int BUFFER_SIZE = 4000; /// Size of input buffers
|
||||
byte[] buffer; /// Buffer for data received in one attempt in RunDeviceBefore()
|
||||
byte[] rcvdData; /// Buffer for all recevied but nut processed data. May contain data from several read attempts
|
||||
int[] cumulativeSums;
|
||||
int rcvdBytesCount; /// Count of valid bytes in rcvdData buffer
|
||||
|
||||
/// Message queue
|
||||
Queue<Action> scheduledActionQueue;
|
||||
|
||||
/// Received data
|
||||
public GeneralData Data;
|
||||
DivTransitionData divTransitionData;
|
||||
ScopeAnalyzerData scopeAnalyzerData;
|
||||
SwitchCountersData switchCounterData;
|
||||
|
||||
|
||||
public UInt64 State { get { return Data.State; } } /// Control board state
|
||||
public UInt64 DigitalInputs { get { return Data.Vstupy; } } /// Digital inputs
|
||||
public Int16 AnalogInput(int channel)
|
||||
{
|
||||
if (Data.AnalogInput != null && channel >= 0 && channel < Data.AnalogInput.Length)
|
||||
{
|
||||
return Data.AnalogInput[channel];
|
||||
}
|
||||
return 0;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Route: 128-bit word representing the current state of all valves and pumps
|
||||
/// </summary>
|
||||
public UInt128 Route { get { return benchModelRoute; } }
|
||||
|
||||
/// Values valid during a test
|
||||
public double RefFrequency { get { return Data.ReferenceFreq[0]; } }
|
||||
|
||||
public double RefFlow
|
||||
{
|
||||
get { return (Devices != null && Devices.FlowMeter != null) ? Devices.FlowMeter.ReadFlow() : 0.0; }
|
||||
}
|
||||
|
||||
/// Last test results
|
||||
public double TestTime { set; get; }
|
||||
public int RefPulses { set; get; }
|
||||
public float ValveOpenCloseTime { set; get; } /// Start valve open or close time in sec
|
||||
|
||||
/// <summary>
|
||||
/// Select devices used for control and measurement
|
||||
/// </summary>
|
||||
/// <param name="outPath"></param>
|
||||
public OutputPath Devices
|
||||
{
|
||||
set { devices = value; }
|
||||
get { return devices; }
|
||||
}
|
||||
|
||||
OutputPath devices;
|
||||
IFlowMeter flowMeter { get { return devices.FlowMeter; } }
|
||||
IRegValve regValve { get { return devices.RegValve; } }
|
||||
IDiverter diverter { get { return devices.Diverter; } }
|
||||
|
||||
|
||||
/// <summary>
|
||||
/// Constructor for user interfaces (change settings only).
|
||||
/// Initialize(), RunDeviceXY() and StopDevice() methods of the created object will not be called.
|
||||
/// </summary>
|
||||
public UniCB()
|
||||
{
|
||||
devices = new OutputPath(string.Empty, 0);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Constructor invoked when starting the test bench and creating components.
|
||||
/// </summary>
|
||||
public UniCB(Generic.IComponentCfg cfg)
|
||||
: base(cfg)
|
||||
{
|
||||
#if DEBUG
|
||||
Debug.WriteLine("");
|
||||
Debug.WriteLine("Uni CB enums");
|
||||
Debug.WriteLine("");
|
||||
foreach (var e in Enum.GetValues(typeof(Poz)))
|
||||
{
|
||||
Debug.WriteLine(string.Format("{0} ... {1}", e, ((int)e)));
|
||||
}
|
||||
#endif
|
||||
cbCfg = cfg as UniCBCfg;
|
||||
|
||||
devices = new OutputPath(string.Empty, 0);
|
||||
scheduledActionQueue = new Queue<Action>();
|
||||
|
||||
Data = new GeneralData();
|
||||
divTransitionData = null;
|
||||
scopeAnalyzerData = null;
|
||||
switchCounterData = null;
|
||||
|
||||
serialPort = null;
|
||||
buffer = new byte[BUFFER_SIZE];
|
||||
rcvdData = new byte[BUFFER_SIZE];
|
||||
cumulativeSums = new int[BUFFER_SIZE];
|
||||
rcvdBytesCount = 0;
|
||||
|
||||
routeMask = 0;
|
||||
for (int i = 0; i < 128; i++)
|
||||
{
|
||||
if (i < cbCfg.VirtValvesRangeLo || i > cbCfg.VirtValvesRangeHi)
|
||||
{
|
||||
routeMask = routeMask | ((UInt128)1 << i);
|
||||
}
|
||||
}
|
||||
|
||||
TBF.UiBridge.Bridge.RouteChangeHandler += delegate(object sndr, TBF.UiBridge.RouteChangeArgs args)
|
||||
{
|
||||
UInt128 mask = ((UInt128)1) << args.BitNr;
|
||||
if ((benchModelRoute & mask) == 0)
|
||||
{
|
||||
benchModelRoute |= mask;
|
||||
}
|
||||
else
|
||||
{
|
||||
benchModelRoute &= (~mask);
|
||||
}
|
||||
};
|
||||
|
||||
log.Warn(this.ToString());
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Specify inverted valves
|
||||
/// </summary>
|
||||
/// <param name="valvesToInvert"></param>
|
||||
public void SpecifyInvertedValves(UInt128 valvesToInvert)
|
||||
{
|
||||
this.valvesToInvert = valvesToInvert;
|
||||
this.benchModelRoute = valvesToInvert;
|
||||
}
|
||||
|
||||
#region IDevice interface
|
||||
|
||||
/// <summary>
|
||||
/// Initialize control board device hardware
|
||||
/// </summary>
|
||||
public void Initialize()
|
||||
{
|
||||
if (cbCfg.DebugLevel != DebugMode.Normal)
|
||||
{
|
||||
log.FatalFormat("{0} - Device simulated", Name);
|
||||
return;
|
||||
}
|
||||
|
||||
serialPort = new SerialPort(comPort, 9600, Parity.None, 8, StopBits.One);
|
||||
serialPort.DtrEnable = true;
|
||||
serialPort.WriteTimeout = 4000;
|
||||
serialPort.ParityReplace = 0xFF;
|
||||
serialPort.Open();
|
||||
|
||||
log.FatalFormat("{0} - Device successfully initialized", Name);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Reecive and process data from the control board serial port
|
||||
/// </summary>
|
||||
public void RunDeviceBefore()
|
||||
{
|
||||
if (cbCfg.DebugLevel != DebugMode.Normal || serialPort == null || !serialPort.IsOpen) return;
|
||||
|
||||
/// Read new received bytes and append them to a buffer
|
||||
int bytesCount = serialPort.BytesToRead;
|
||||
if (bytesCount > 0)
|
||||
{
|
||||
bytesCount = serialPort.Read(buffer, 0, Math.Min(bytesCount, BUFFER_SIZE));
|
||||
}
|
||||
for (int i = 0; i < bytesCount && rcvdBytesCount < BUFFER_SIZE; i++, rcvdBytesCount++)
|
||||
{
|
||||
rcvdData[rcvdBytesCount] = buffer[i];
|
||||
}
|
||||
|
||||
/// Calculate cumulative sums (to verify checksums easily)
|
||||
int cumulativeSum = 0;
|
||||
for (int i = 0; i < rcvdBytesCount; i++)
|
||||
{
|
||||
cumulativeSum += rcvdData[i];
|
||||
cumulativeSums[i] = cumulativeSum;
|
||||
}
|
||||
|
||||
/// Try to detect various kinds of data in rcvdData buffer in a loop, start at offset 0
|
||||
int offset = 0;
|
||||
int lastValidOffset = 0; /// Offset of the first byte after the last successfully parsed frame
|
||||
do
|
||||
{
|
||||
bool anyProcessed = false;
|
||||
if (ScopeAnalyzerData.FrameFitsData(rcvdData, cumulativeSums, rcvdBytesCount, offset))
|
||||
{
|
||||
/// Scope analyzer data received
|
||||
scopeAnalyzerData = ScopeAnalyzerData.GetData(rcvdData, offset);
|
||||
string s = Telegram.LogTelegram("Scope analyzer data ", rcvdData, offset, ScopeAnalyzerData.MessageLen);
|
||||
Debug.WriteLine(s);
|
||||
log.Debug(s);
|
||||
offset += ScopeAnalyzerData.MessageLen;
|
||||
lastValidOffset = offset;
|
||||
anyProcessed = true;
|
||||
}
|
||||
else if (GeneralData.FrameFitsData(rcvdData, cumulativeSums, rcvdBytesCount, offset))
|
||||
{
|
||||
/// Regular data received
|
||||
Data.UpdateData(rcvdData, offset);
|
||||
string s = Telegram.LogTelegram("General data ", rcvdData, offset, GeneralData.MessageLen);
|
||||
Debug.WriteLine(s);
|
||||
log.Debug(s);
|
||||
offset += GeneralData.MessageLen;
|
||||
lastValidOffset = offset;
|
||||
anyProcessed = true;
|
||||
}
|
||||
else if (SwitchCountersData.FrameFitsData(rcvdData, cumulativeSums, rcvdBytesCount, offset))
|
||||
{
|
||||
/// Switch counter data received
|
||||
switchCounterData = SwitchCountersData.GetData(rcvdData, offset);
|
||||
string s = Telegram.LogTelegram("Switch counter data ", rcvdData, offset, SwitchCountersData.MessageLen);
|
||||
Debug.WriteLine(s);
|
||||
log.Debug(s);
|
||||
offset += SwitchCountersData.MessageLen;
|
||||
lastValidOffset = offset;
|
||||
anyProcessed = true;
|
||||
}
|
||||
else if (DivTransitionData.FrameFitsData(rcvdData, cumulativeSums, rcvdBytesCount, offset))
|
||||
{
|
||||
/// Diverter transition data received
|
||||
divTransitionData = DivTransitionData.GetData(rcvdData, offset);
|
||||
string s = Telegram.LogTelegram("Diverter transition data ", rcvdData, offset, DivTransitionData.MessageLen);
|
||||
Debug.WriteLine(s);
|
||||
log.Debug(s);
|
||||
offset += DivTransitionData.MessageLen;
|
||||
lastValidOffset = offset;
|
||||
anyProcessed = true;
|
||||
}
|
||||
|
||||
if (!anyProcessed) offset++;
|
||||
}
|
||||
while (offset < rcvdBytesCount);
|
||||
|
||||
/// Remove processed data from the receive buffer
|
||||
for (int i = lastValidOffset; i < rcvdBytesCount; i++)
|
||||
{
|
||||
rcvdData[i - lastValidOffset] = rcvdData[i];
|
||||
}
|
||||
rcvdBytesCount -= lastValidOffset;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Send data to the control board serial port
|
||||
/// </summary>
|
||||
public void RunDeviceAfter()
|
||||
{
|
||||
if (cbCfg.DebugLevel != DebugMode.Normal) return;
|
||||
|
||||
/// Make sure the serial port is open
|
||||
if (serialPort == null || !serialPort.IsOpen)
|
||||
{
|
||||
/// Serial port is closed or does not exist => re-open the serial port
|
||||
try
|
||||
{
|
||||
if (serialPort == null)
|
||||
{
|
||||
serialPort = new SerialPort(comPort, 9600, Parity.None, 8, StopBits.One);
|
||||
}
|
||||
serialPort.DtrEnable = true;
|
||||
serialPort.WriteTimeout = 4000;
|
||||
serialPort.ParityReplace = 0xFF;
|
||||
serialPort.Open();
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
/// Re-opening serial port failed
|
||||
return;
|
||||
}
|
||||
}
|
||||
|
||||
if (!outputsInitialized || Data.Vystupy != (ulong)benchModelRoute || (StateMachine.Time - lastStateMachineTime) >= 15)
|
||||
{
|
||||
scheduledActionQueue.Enqueue(Action.ChangeRoute((ulong)benchModelRoute));
|
||||
log.InfoFormat("Enqueue( ChangeRoute(route={0:X}) )", benchModelRoute);
|
||||
foreach (var a in scheduledActionQueue) log.DebugFormat(" {0}", a);
|
||||
}
|
||||
|
||||
var combinedAction = Action.FetchNonConflictingActions(scheduledActionQueue);
|
||||
|
||||
byte[] outData = OutputMessage.GetMessage(combinedAction, config);
|
||||
if (outData != null && outData.Length > 0)
|
||||
{
|
||||
serialPort.Write(outData, 0, outData.Length);
|
||||
string s = Telegram.LogTelegram("Sent: ", outData);
|
||||
Debug.WriteLine(s);
|
||||
log.Debug(s);
|
||||
}
|
||||
|
||||
ProcessData.UpdateMeasuredValuesAndSetpoints();
|
||||
TBF.UiBridge.Bridge.OnStateMachineTick(this, new TBF.UiBridge.StateMachineTickEventArgs(Route, ProcessData.MsrmntAvailableFlags,
|
||||
ProcessData.MeasuredValues,
|
||||
ProcessData.AltStrings,
|
||||
ProcessData.Setpoints));
|
||||
}
|
||||
|
||||
public void StopDevice()
|
||||
{
|
||||
if (serialPort != null) serialPort.Close();
|
||||
serialPort = null;
|
||||
}
|
||||
|
||||
public void StopDevice2()
|
||||
{
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
#region IControlBoard interface
|
||||
|
||||
///
|
||||
/// Interface functions
|
||||
///
|
||||
public void ClearProcessValues() { }
|
||||
|
||||
public double TestTimeWM(int wmNr1)
|
||||
{
|
||||
if (wmNr1 >= 1 && wmNr1 < Data.ImpulseTime.Length)
|
||||
{
|
||||
return Data.ImpulseTime[wmNr1];
|
||||
}
|
||||
return 0;
|
||||
}
|
||||
|
||||
public int RefPulsesWM(int wmNr1)
|
||||
{
|
||||
if (wmNr1 >= 1 && wmNr1 < Data.EtPulses.Length)
|
||||
{
|
||||
return Data.EtPulses[wmNr1];
|
||||
}
|
||||
return 0;
|
||||
}
|
||||
|
||||
public int PulsesWM(int wmNr1)
|
||||
{
|
||||
if (wmNr1 >= 1 && wmNr1 < Data.WMeterPuls.Length)
|
||||
{
|
||||
return Data.WMeterPuls[wmNr1];
|
||||
}
|
||||
return 0;
|
||||
}
|
||||
|
||||
public UInt128 SetValves(UInt128 valvesToOpen, UInt128 valvesToClose, IList<BuiltIn.ValveEx.Valve> extendedValves)
|
||||
{
|
||||
UInt128 oldRoute = benchModelRoute;
|
||||
benchModelRoute = (((benchModelRoute ^ valvesToInvert) | valvesToOpen) & (~valvesToClose)) ^ valvesToInvert;
|
||||
foreach (var extV in extendedValves) extV.UpdateRoute(ref benchModelRoute);
|
||||
log.DebugFormat("SetValves(x,x), new route = {0}", Utils.RouteToStr(benchModelRoute));
|
||||
UInt128 retVal = oldRoute ^ benchModelRoute;
|
||||
|
||||
log.DebugFormat("{0}.SetValves({1}, {2}) returns {3}", Name, valvesToOpen.ToString("X"), valvesToClose.ToString("X"), retVal.ToString("X"));
|
||||
return retVal;
|
||||
}
|
||||
|
||||
///
|
||||
/// Operations
|
||||
///
|
||||
public IOperation SetFlowOp(double flowLimLo, double flowLimHi, TBF.Boxes.DoubleBox measuredFlow, int timeout)
|
||||
{
|
||||
return Devices.RegValve.SetFlowOp(Devices.FlowMeter,flowLimLo, flowLimHi, measuredFlow, timeout);
|
||||
}
|
||||
|
||||
public IOperation StopFlowRegulationOp()
|
||||
{
|
||||
//scheduledActionQueue.Enqueue(Action.Stop());
|
||||
return null;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Start a test, Events: MeasurementStarted
|
||||
/// </summary>
|
||||
/// <param name="iParam">Int32 parameter 1</param>
|
||||
/// <param name="dParam1">Double parameter 1 (alternative lower flow limit)</param>
|
||||
/// <param name="dParam2">Double parameter 2 (alternative upper flow limit)</param>
|
||||
/// <returns>Operation</returns>
|
||||
public IOperation StartTestOp(Test test, int iParam = 0, double dParam1 = 0, double dParam2 = 0)
|
||||
{
|
||||
return null;
|
||||
}
|
||||
|
||||
public IOperation ReadDiverterTransitionOp(bool isStart, Sequences.Statistics plotter, int batchNr, string testName, int repetition)
|
||||
{
|
||||
return null;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Returns operation with events: Event.MeasurementCompleted or Event.None
|
||||
/// </summary>
|
||||
/// <returns>Operation</returns>
|
||||
public IOperation QueryMeasurementEndOp()
|
||||
{
|
||||
return null;
|
||||
}
|
||||
|
||||
public IOperation StopPreviousOp()
|
||||
{
|
||||
return null;
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
#region IValveControl interface
|
||||
|
||||
/// <summary>
|
||||
/// Open/close one valve.
|
||||
/// Events: ValvesSet, ValvesBusy, Error
|
||||
/// </summary>
|
||||
/// <param name="valveToOpen">Valve to be opened</param>
|
||||
/// <param name="valveToClose">Valve to be closed</param>
|
||||
/// <returns>Newly created operation instance reference casted to IOperaton</returns>
|
||||
public IOperation SetValvesOp(IValve valveOpen, IValve valveClose)
|
||||
{
|
||||
return new BuiltIn.SetValvesOp(this, valveOpen, valveClose);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Open/close multiple valves.
|
||||
/// Events: ValvesSet, ValvesBusy, Error
|
||||
/// </summary>
|
||||
/// <param name="valvesToOpen">A list of valves to be opened</param>
|
||||
/// <param name="valvesToClose">A list of valves to be closed</param>
|
||||
/// <returns>Newly created operation instance reference casted to IOperaton</returns>
|
||||
public IOperation SetValvesOp(IList<IValve> valvesOpen, IList<IValve> valvesClose)
|
||||
{
|
||||
return new BuiltIn.SetValvesOp(this, valvesOpen, valvesClose);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Open start/stop valve.
|
||||
/// Events: ValvesSet, ValvesBusy, Error
|
||||
/// </summary>
|
||||
/// <returns>Created operation</returns>
|
||||
public IOperation OpenStartValveOp()
|
||||
{
|
||||
return new BuiltIn.SetValvesOp(this, true, devices);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Close start/stop valve.
|
||||
/// Events: ValvesSet, ValvesBusy, Error
|
||||
/// </summary>
|
||||
/// <returns>Created operation</returns>
|
||||
public IOperation CloseStartValveOp()
|
||||
{
|
||||
return new BuiltIn.SetValvesOp(this, false, devices);
|
||||
}
|
||||
|
||||
#endregion
|
||||
|
||||
public void MeasureFlow(int flowMeterId)
|
||||
{
|
||||
scheduledActionQueue.Enqueue(Action.MeasureFlow(flowMeterId));
|
||||
log.InfoFormat("Enqueue( MeasureFlow(fm={0}) )", flowMeterId);
|
||||
foreach (var a in scheduledActionQueue) log.DebugFormat(" {0}", a);
|
||||
}
|
||||
|
||||
public void SetFlow(int flowMeterId, int regVId, double freqLo, double freqHi)
|
||||
{
|
||||
scheduledActionQueue.Enqueue(Action.SetFlow(flowMeterId, regVId, freqLo, freqHi, Convert.ToInt32(Math.Round(Devices.PidCoef)), 0, 200));
|
||||
log.InfoFormat("Enqueue( SetFlow(fm={0}, rv={1}, fLo={2}, fHi={3}, pid={4}) )", flowMeterId, regVId, freqLo, freqHi, Convert.ToInt32(Math.Round(Devices.PidCoef)));
|
||||
foreach (var a in scheduledActionQueue) log.DebugFormat(" {0}", a);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Perform incremental movement of a regulation valve
|
||||
/// </summary>
|
||||
/// <param name="rvId">Reg. valve ID</param>
|
||||
/// <param name="time">Time in seconds, positive value opens the reg. valve</param>
|
||||
public void RegVlvIncrMove(int regVId, double time)
|
||||
{
|
||||
scheduledActionQueue.Enqueue(Action.RegVlvIncrMove(regVId, time));
|
||||
log.InfoFormat("Enqueue( RegVlvIncrMove(rv={0}, time={1}) )", regVId, time);
|
||||
foreach (var a in scheduledActionQueue) log.DebugFormat(" {0}", a);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Move a regulation valve to specfied position
|
||||
/// </summary>
|
||||
/// <param name="rvId">Reg. valve ID</param>
|
||||
/// <param name="position">Reg. valve position (0 .. 1.0)</param>
|
||||
public void RegVlvMoveToPos(int regVId, double positionLo, double positionHi = -1)
|
||||
{
|
||||
scheduledActionQueue.Enqueue(Action.RegVlvMoveToPos(regVId, positionLo, positionHi));
|
||||
log.InfoFormat("Enqueue( RegVlvMoveToPos(rv={0}, positionLo={1}, positionHi={2}) )", regVId, positionLo, positionHi);
|
||||
foreach (var a in scheduledActionQueue) log.DebugFormat(" {0}", a);
|
||||
}
|
||||
|
||||
public void DiverterToTank(int divNr1)
|
||||
{
|
||||
scheduledActionQueue.Enqueue(Action.SwitchDiverter(divNr1, true));
|
||||
log.InfoFormat("Enqueue( SwitchDiverter(div={0}, true) )", divNr1);
|
||||
foreach (var a in scheduledActionQueue) log.DebugFormat(" {0}", a);
|
||||
}
|
||||
|
||||
public void DiverterToSink(int divNr1)
|
||||
{
|
||||
scheduledActionQueue.Enqueue(Action.SwitchDiverter(divNr1, false));
|
||||
log.InfoFormat("Enqueue( SwitchDiverter(div={0}, false) )", divNr1);
|
||||
foreach (var a in scheduledActionQueue) log.DebugFormat(" {0}", a);
|
||||
}
|
||||
|
||||
public void ReadDiverterTransition(int divNr1)
|
||||
{
|
||||
/// TODO
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,188 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Xml.Serialization;
|
||||
using Config.Entities;
|
||||
using SchematicDrawing;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
/// <summary>
|
||||
/// Holds backup and security options - serializable configuration.
|
||||
/// </summary>
|
||||
public class UniCBCfg : ComponentCfgBase, Generic.IComponentCfg, Config.Entities.IParamsProvider, IDrawingItemWithMeasuredVal
|
||||
{
|
||||
public static XmlSerializer Serializer = XmlSerializer.FromTypes(new[] { typeof(UniCBCfg) })[0];
|
||||
public override XmlSerializer GetSerializer() { return Serializer; }
|
||||
|
||||
public IComponentCfgCtrl GetControl(IList<Config.Entities.Component> cmpntEntities) { return new Configs.ParamsProvider.ComponentCfgCtrl(this, null); }
|
||||
|
||||
///
|
||||
/// Serialized parameters
|
||||
///
|
||||
public int ComPortNr;
|
||||
public int DivertersCount;
|
||||
public int DrainValvesCount;
|
||||
public int RegValvesCount;
|
||||
public int VirtValvesRangeLo;
|
||||
public int VirtValvesRangeHi;
|
||||
|
||||
/// Schematic drawing info
|
||||
public Shape Shape { get; set; }
|
||||
public int X { get; set; }
|
||||
public int Y { get; set; }
|
||||
public Sz Sz { get; set; }
|
||||
public Orient Orient { get; set; }
|
||||
public bool Flip { get; set; }
|
||||
public int LblX { get; set; }
|
||||
public int LblY { get; set; }
|
||||
public Orient LblOrient { get; set; }
|
||||
public int MsrdX { get; set; }
|
||||
public int MsrdY { get; set; }
|
||||
public Orient MsrdOrient { get; set; }
|
||||
public Config.Unit MsrdUnit { get; set; }
|
||||
public string MsrdFormat { get; set; }
|
||||
public double MsrdValLimLo { get; set; }
|
||||
public double MsrdValLimHi { get; set; }
|
||||
|
||||
[XmlIgnore]
|
||||
public IList<GNode> GNodes { get; set; }
|
||||
[XmlIgnore]
|
||||
public IList<GEdge> EdgesToSet { get; set; }
|
||||
|
||||
/// Private parameterless constructor invoked by all other (public) constructors
|
||||
UniCBCfg()
|
||||
{
|
||||
GNodes = new List<GNode>();
|
||||
EdgesToSet = new List<GEdge>();
|
||||
}
|
||||
|
||||
public UniCBCfg(string name, IComponentFactory factory)
|
||||
: this()
|
||||
{
|
||||
Shape = Shape.UniCB;
|
||||
Sz = Sz.L;
|
||||
|
||||
Name = name;
|
||||
Factory = factory;
|
||||
ParentName = string.Empty;
|
||||
InitializeAll();
|
||||
}
|
||||
|
||||
public string ComponentName { get { return Name; } }
|
||||
|
||||
public void InitializeAll()
|
||||
{
|
||||
ComPortNr = 1;
|
||||
VirtValvesRangeLo = 90;
|
||||
VirtValvesRangeHi = 99;
|
||||
}
|
||||
|
||||
string[] paramNames = new string[]
|
||||
{
|
||||
"Serial port number",
|
||||
"Diverters count (1..5)",
|
||||
"Drain valves count (0..8)",
|
||||
"Regulation valves count (4..8)",
|
||||
"Virtual valves range LO [bit#]",
|
||||
"Virtual valves range HI [bit#]",
|
||||
};
|
||||
public string ParamName(int i) { return paramNames[i]; }
|
||||
public int ParamsCount() { return paramNames.Length; }
|
||||
|
||||
public ICollection<string> ParamValues(int i)
|
||||
{
|
||||
return null;
|
||||
}
|
||||
|
||||
public string ToString(int i)
|
||||
{
|
||||
if (i == -1)
|
||||
{
|
||||
return string.Format("{0}: COM{1}, VirtValvesRngLO={2}, VirtValvesRngeHI={3}", Name, ComPortNr, VirtValvesRangeLo, VirtValvesRangeHi);
|
||||
}
|
||||
|
||||
switch (i)
|
||||
{
|
||||
case 0: return ComPortNr.ToString();
|
||||
case 1: return DivertersCount.ToString();
|
||||
case 2: return DrainValvesCount.ToString();
|
||||
case 3: return RegValvesCount.ToString();
|
||||
case 4: return VirtValvesRangeLo.ToString();
|
||||
case 5: return VirtValvesRangeHi.ToString();
|
||||
default: return string.Empty;
|
||||
}
|
||||
}
|
||||
|
||||
public CfgUpdateFlags UpdateParam(int i, string strValue)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0: ComPortNr = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 1: DivertersCount = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 2: DrainValvesCount = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 3: RegValvesCount = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 4: VirtValvesRangeLo = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
case 5: VirtValvesRangeHi = int.Parse(strValue); return CfgUpdateFlags.RestartRqrd;
|
||||
default: return CfgUpdateFlags.None;
|
||||
}
|
||||
}
|
||||
|
||||
public bool ValidateParam(int i, string strValue, out string message)
|
||||
{
|
||||
message = string.Empty;
|
||||
int n;
|
||||
|
||||
switch (i)
|
||||
{
|
||||
case 0:
|
||||
if (int.TryParse(strValue, out n) && (n >= 1)) return true;
|
||||
break;
|
||||
case 1:
|
||||
if (int.TryParse(strValue, out n) && (n >= 1) && n <= 5) return true;
|
||||
break;
|
||||
case 2:
|
||||
if (int.TryParse(strValue, out n) && (n >= 0) && n <= 8) return true;
|
||||
break;
|
||||
case 3:
|
||||
if (int.TryParse(strValue, out n) && (n >= 4) && n <= 8) return true;
|
||||
break;
|
||||
case 4:
|
||||
case 5:
|
||||
if (int.TryParse(strValue, out n) && (n >= 0) && n <= 127) return true;
|
||||
break;
|
||||
default:
|
||||
message = "Invalid index";
|
||||
return false;
|
||||
}
|
||||
|
||||
message = ParamName(i) + " is invalid";
|
||||
return false;
|
||||
}
|
||||
|
||||
void CopyContentTo(UniCBCfg prms)
|
||||
{
|
||||
prms.ComPortNr = ComPortNr;
|
||||
prms.DivertersCount = DivertersCount;
|
||||
prms.DrainValvesCount = DrainValvesCount;
|
||||
prms.RegValvesCount = RegValvesCount;
|
||||
prms.VirtValvesRangeLo = VirtValvesRangeLo;
|
||||
prms.VirtValvesRangeHi = VirtValvesRangeHi;
|
||||
}
|
||||
|
||||
public Config.Entities.IParamsProvider Clone()
|
||||
{
|
||||
var pars = new UniCBCfg();
|
||||
CopyContentTo(pars);
|
||||
return pars;
|
||||
}
|
||||
|
||||
public bool UpdateEmbeddedDbEntity()
|
||||
{
|
||||
return true; /// =OK, do nothing
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,55 @@
|
||||
///
|
||||
/// Copyright (c) 2021 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Diagnostics;
|
||||
|
||||
namespace TBF.Rig.ControlBoard.Uni
|
||||
{
|
||||
class ValveMoveMsg
|
||||
{
|
||||
public int PayloadLen { get { return 38; } }
|
||||
public byte MessageCode { get { return 0x20; } }
|
||||
|
||||
Command cmd;
|
||||
int regValveNr;
|
||||
|
||||
public ValveMoveMsg(Command cmd, int regValveNr)
|
||||
{
|
||||
this.cmd = cmd;
|
||||
this.regValveNr = regValveNr;
|
||||
}
|
||||
|
||||
public byte[] GetMessage()
|
||||
{
|
||||
byte[] message = new byte[PayloadLen + 5]; /// headed 3 bytes, checksum 2 bytes
|
||||
|
||||
/// Header (3 bytes)
|
||||
message[0] = Const.STX;
|
||||
message[1] = 1; /// Control board addres
|
||||
message[2] = (byte)PayloadLen; /// Payload length
|
||||
|
||||
/// Command
|
||||
message[3] = MessageCode;
|
||||
message[4] = (byte)cmd;
|
||||
|
||||
/// ...
|
||||
|
||||
message[40] = 0;
|
||||
Debug.Assert(40 == PayloadLen + 2);
|
||||
|
||||
/// Checksum (2 bytes)
|
||||
int checksum = 0;
|
||||
for (int i = 1; i < PayloadLen + 3; i++) checksum += message[i];
|
||||
message[PayloadLen + 3] = (byte)(checksum & 0xFF);
|
||||
message[PayloadLen + 4] = (byte)((checksum >> 8) & 0xFF);
|
||||
|
||||
return message;
|
||||
}
|
||||
|
||||
public override string ToString()
|
||||
{
|
||||
return string.Format("ValveMoveMsg : {0}", cmd);
|
||||
}
|
||||
}
|
||||
}
|
||||