Refactorization : BenchControl -> Rig
This commit is contained in:
@@ -0,0 +1,253 @@
|
||||
///
|
||||
/// Copyright (c) 2013-2016 Sensus Metering Systems
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Globalization;
|
||||
using System.IO.Ports;
|
||||
using System.Text;
|
||||
using log4net;
|
||||
using Config;
|
||||
using Config.Entities;
|
||||
using SchematicDrawing;
|
||||
using TBF.Rig.Generic;
|
||||
using TBF.Boxes;
|
||||
|
||||
namespace TBF.Rig.Ambient.Greco
|
||||
{
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
/// Connection settings: 19200 Bd 8-bits No-parity 1-stop-bit Flow control: none or hardware.
|
||||
/// </summary>
|
||||
public class Ambient : ComponentBase, IDevice, IOperation, GenericDevices.IAmbient, IDrawingItCmpntWithMeasuredVal
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(Ambient));
|
||||
public override string ToString() { return string.Format("Ambient({0})", Cfg.ToString(1)); }
|
||||
|
||||
private readonly AmbientCfg ambientCfg;
|
||||
///
|
||||
Unit TempUnit { get { return ambientCfg.TempUnit; } }
|
||||
double TempLimLo { get { return Units.ConvertFrom(TempUnit, ambientCfg.TempLimLo); } }
|
||||
double TempLimHi { get { return Units.ConvertFrom(TempUnit, ambientCfg.TempLimHi); } }
|
||||
double DefaultTemperature { get { return Units.ConvertFrom(TempUnit, ambientCfg.DefaultTemp); } }
|
||||
///
|
||||
Unit PressureUnit { get { return ambientCfg.PressureUnit; } }
|
||||
double PressureLimLo { get { return Units.ConvertFrom(PressureUnit, ambientCfg.PressureLimLo); } }
|
||||
double PressureLimHi { get { return Units.ConvertFrom(PressureUnit, ambientCfg.PressureLimHi); } }
|
||||
double DefaultPressure { get { return Units.ConvertFrom(PressureUnit, ambientCfg.DefaultPressure); } }
|
||||
///
|
||||
Unit HumiUnit { get { return ambientCfg.HumiUnit; } }
|
||||
double HumiLimLo { get { return Units.ConvertFrom(HumiUnit, ambientCfg.HumiLimLo); } }
|
||||
double HumiLimHi { get { return Units.ConvertFrom(HumiUnit, ambientCfg.HumiLimHi); } }
|
||||
double DefaultHumidity { get { return Units.ConvertFrom(HumiUnit, ambientCfg.DefaultHumi); } }
|
||||
|
||||
///
|
||||
/// IDrawingItCmpntWithMeasuredVal interface
|
||||
///
|
||||
public IDrawingItem DrawingItem { get { return ambientCfg as IDrawingItem; } }
|
||||
public bool MsrmntAvailable { get { return true; } }
|
||||
public double MeasuredVal { get { return temperature; } }
|
||||
public string AltString
|
||||
{
|
||||
get {
|
||||
return string.Format(ambientCfg.Format, Units.ConvertTo(TempUnit, temperature),
|
||||
Units.ConvertTo(PressureUnit, pressure),
|
||||
Units.ConvertTo(HumiUnit, humidity));
|
||||
}
|
||||
}
|
||||
|
||||
/// Private fields
|
||||
SerialPort serialPort;
|
||||
StringBuilder measurementBuilder;
|
||||
|
||||
/// <summary>The state of the measurement</summary>
|
||||
MsrmntState msrmntState;
|
||||
|
||||
///
|
||||
/// Measured values when MsrmntState == MsrmntState.Valid
|
||||
///
|
||||
double temperature; /// [°C]
|
||||
double pressure; /// [bar]
|
||||
double humidity; /// [R%]
|
||||
|
||||
/// <summary>Measurement time stamp when MsrmntState == MsrmntState.Valid</summary>
|
||||
int msrmntTimeStamp;
|
||||
|
||||
public Ambient()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Ambient temperature / humidity / pressure meter 'Greco' connected via serial interface (RS232)
|
||||
/// Connection settings: 19200 Bd 8-bits No-parity 1-stop-bit Flow control: none or hardware.
|
||||
/// </summary>
|
||||
public Ambient(AmbientCfg cfg, IList<Generic.IComponent> components)
|
||||
: this(cfg)
|
||||
{
|
||||
}
|
||||
|
||||
public Ambient(Generic.IComponentCfg cfg)
|
||||
: base(cfg)
|
||||
{
|
||||
ambientCfg = cfg as AmbientCfg;
|
||||
|
||||
temperature = DefaultTemperature;
|
||||
pressure = DefaultPressure;
|
||||
humidity = DefaultHumidity;
|
||||
|
||||
log.Warn(this.ToString());
|
||||
}
|
||||
|
||||
public void Initialize()
|
||||
{
|
||||
if (ambientCfg.DebugLevel == DebugMode.Simulate)
|
||||
{
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
return;
|
||||
}
|
||||
|
||||
string comPortName = "COM" + ambientCfg.ComPortNr.ToString();
|
||||
serialPort = new SerialPort(comPortName, ambientCfg.BaudRate, ambientCfg.Parity, ambientCfg.DataBits, ambientCfg.StopBits);
|
||||
serialPort.Handshake = ambientCfg.Handshake;
|
||||
serialPort.Open();
|
||||
measurementBuilder = new StringBuilder(40);
|
||||
msrmntState = MsrmntState.Busy;
|
||||
|
||||
log.FatalFormat("Successfully initialized device {0}", ToString());
|
||||
}
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
public void RunDeviceBefore()
|
||||
{
|
||||
if (ambientCfg.DebugLevel == DebugMode.Simulate ||
|
||||
ambientCfg.DebugLevel == DebugMode.FailureDuringOperation)
|
||||
{
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
return;
|
||||
}
|
||||
|
||||
try
|
||||
{
|
||||
measurementBuilder.Append(serialPort.ReadExisting());
|
||||
int len = measurementBuilder.Length;
|
||||
|
||||
///
|
||||
/// Device sends each 20 sec one line of ASCII text with data in the following format:
|
||||
/// (temp) 6 characters, two decimal digits, with leading spaces
|
||||
/// TAB 1 character
|
||||
/// (humi) 6 characters, two decimal digits, with leading spaces
|
||||
/// TAB 1 character
|
||||
/// (pressure) 6 characters, one decimal digits, with leading spaces is LT 1000
|
||||
/// CR + LF 2 characters
|
||||
/// Example:
|
||||
/// 23.42 38.08 1061.1
|
||||
/// 23.39 38.04 1060.8
|
||||
/// 23.39 38.08 1061.4
|
||||
///
|
||||
if (len >= 22)
|
||||
{
|
||||
string measurement = measurementBuilder.ToString();
|
||||
measurementBuilder.Clear();
|
||||
|
||||
double t = 0;
|
||||
double h = 0;
|
||||
double p = 0;
|
||||
if (double.TryParse(measurement.Substring(len - 22, 6), NumberStyles.AllowDecimalPoint | NumberStyles.AllowLeadingWhite,
|
||||
CultureInfo.InvariantCulture, out t) &&
|
||||
measurement[len - 16] == '\t' &&
|
||||
double.TryParse(measurement.Substring(len - 15, 6), NumberStyles.AllowDecimalPoint | NumberStyles.AllowLeadingWhite,
|
||||
CultureInfo.InvariantCulture, out h) &&
|
||||
measurement[len - 9] == '\t' &&
|
||||
double.TryParse(measurement.Substring(len - 8, 6), NumberStyles.AllowDecimalPoint | NumberStyles.AllowLeadingWhite,
|
||||
CultureInfo.InvariantCulture, out p) &&
|
||||
measurement[len - 2] == '\r' &&
|
||||
measurement[len - 1] == '\n')
|
||||
{
|
||||
temperature = t;
|
||||
humidity = h;
|
||||
pressure = p / 1000.0;
|
||||
|
||||
UpdateProcessData(temperature, pressure, humidity);
|
||||
msrmntTimeStamp = StateMachine.Time;
|
||||
msrmntState = MsrmntState.Valid;
|
||||
log.InfoFormat("Ambient: temperature = {0:F1} C, humidity = {1:F1} %, pressure = {2:F0} mbar", temperature, humidity, 1000 * pressure);
|
||||
}
|
||||
else
|
||||
{
|
||||
log.Warn("Invalid string received: " + measurement);
|
||||
}
|
||||
}
|
||||
}
|
||||
catch (Exception e)
|
||||
{
|
||||
DebugLevel = DebugMode.FailureDuringOperation;
|
||||
serialPort = null;
|
||||
|
||||
log.FatalFormat("Ambient: Serail port read failure : {0}", e.Message);
|
||||
if (e.InnerException != null)
|
||||
{
|
||||
log.FatalFormat("InnerMessage : {0}", e.InnerException.Message);
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Run this device</summary>
|
||||
public void RunDeviceAfter()
|
||||
{
|
||||
}
|
||||
|
||||
/// <summary>Stop this device</summary>
|
||||
public void StopDevice()
|
||||
{
|
||||
if (serialPort != null) serialPort.Close();
|
||||
}
|
||||
|
||||
public void StopDevice2() { }
|
||||
|
||||
void UpdateProcessData(double temperature, double pressure, double humidity)
|
||||
{
|
||||
TBF.Rig.Sequences.ProcessData.AmbTemp.Val = temperature;
|
||||
TBF.Rig.Sequences.ProcessData.AmbPress.Val = pressure;
|
||||
TBF.Rig.Sequences.ProcessData.AmbHumi.Val = humidity;
|
||||
}
|
||||
|
||||
///
|
||||
/// Boxes for the operation result
|
||||
///
|
||||
DoubleBox tempBox;
|
||||
DoubleBox pressureBox;
|
||||
DoubleBox humiBox;
|
||||
|
||||
public IOperation ReadAmbientOp(DoubleBox temperature, DoubleBox pressure, DoubleBox humidity)
|
||||
{
|
||||
this.tempBox = temperature;
|
||||
this.pressureBox = pressure;
|
||||
this.humiBox = humidity;
|
||||
return this;
|
||||
}
|
||||
|
||||
/// <summary>Start this operation</summary>
|
||||
public void Start()
|
||||
{
|
||||
if (tempBox != null) tempBox.Val = temperature;
|
||||
if (pressureBox != null) pressureBox.Val = pressure;
|
||||
if (humiBox != null) humiBox.Val = humidity;
|
||||
}
|
||||
|
||||
/// <summary>Run this operation</summary>
|
||||
/// <returns>
|
||||
/// Event.FlowInDone or Event.FlowOutDone
|
||||
/// </returns>
|
||||
public Event Run()
|
||||
{
|
||||
if (tempBox != null) tempBox.Val = temperature;
|
||||
if (pressureBox != null) pressureBox.Val = pressure;
|
||||
if (humiBox != null) humiBox.Val = humidity;
|
||||
return Event.AmbientDone;
|
||||
}
|
||||
|
||||
/// <summary>Stop this operation</summary>
|
||||
public void Stop() { }
|
||||
}
|
||||
}
|
||||
Reference in New Issue