UltrasoundLevelMeter is displayed on the schematic drawing.
This commit is contained in:
@@ -1,22 +1,24 @@
|
||||
///
|
||||
/// Copyright (c) 2018 Sensus Slovensko a.s.
|
||||
/// Copyright (c) 2018-2022 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.Diagnostics;
|
||||
using log4net;
|
||||
using Common;
|
||||
using SchematicDrawing;
|
||||
using TBF.Boxes;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.Modbus.UltrasoundLevelMeter
|
||||
{
|
||||
public class LevelMeter : ComponentBase, GenericDevices.ILevelMeter, IDevice
|
||||
public class LevelMeter : ComponentBase, GenericDevices.ILevelMeter, IDevice, IDrawingItCmpntWithMeasuredVal
|
||||
{
|
||||
private static readonly ILog log = LogManager.GetLogger(typeof(LevelMeter));
|
||||
public override string ToString() { return string.Format("{0}({1})", ClassName, Cfg.ToString(-1)); }
|
||||
|
||||
readonly LevelMeterCfg myCfg;
|
||||
public IDrawingItem DrawingItem { get { return myCfg as IDrawingItem; } }
|
||||
|
||||
Common.Modbus modbus;
|
||||
|
||||
@@ -31,6 +33,14 @@ namespace TBF.Rig.Modbus.UltrasoundLevelMeter
|
||||
|
||||
public double Level { get { return level; } }
|
||||
|
||||
public bool MsrmntAvailable { get { return true; } }
|
||||
public double MeasuredVal { get { return level; } }
|
||||
public double MsrdValLimLo { get { return Units.ConvertFrom(MsrdUnit, myCfg.MsrdValLimLo); } }
|
||||
public double MsrdValLimHi { get { return Units.ConvertFrom(MsrdUnit, myCfg.MsrdValLimHi); } }
|
||||
public string MsrdFormat { get { return myCfg.MsrdFormat; } }
|
||||
public Unit MsrdUnit { get { return myCfg.MsrdUnit; } }
|
||||
public string AltString { get { return string.Empty; } }
|
||||
|
||||
/// <summary>Measurement time stamp when MsrmntState == MsrmntState.Valid</summary>
|
||||
int msrmntTimeStamp;
|
||||
|
||||
@@ -133,7 +143,7 @@ namespace TBF.Rig.Modbus.UltrasoundLevelMeter
|
||||
|
||||
/// Prepare data to be sent
|
||||
byte[] msg = new byte[8]; /// Buffer for data to send
|
||||
msg[0] = myCfg.ModbusAddress;
|
||||
msg[0] = (byte)myCfg.ModbusAddress;
|
||||
msg[1] = 3; /// CMD =
|
||||
msg[2] = (byte)(regAddr >> 8); /// Control Word Hi
|
||||
msg[3] = (byte)(regAddr & 0xFF); /// Control Word Lo
|
||||
|
||||
@@ -1,18 +1,16 @@
|
||||
///
|
||||
/// Copyright (c) 2018 Sensus Slovensko a.s.
|
||||
/// Copyright (c) 2018-2022 Sensus Slovensko a.s.
|
||||
///
|
||||
using System;
|
||||
using System.Collections.Generic;
|
||||
using System.IO;
|
||||
using System.Linq;
|
||||
using System.Xml.Serialization;
|
||||
using Common;
|
||||
using Config.Entities;
|
||||
using SchematicDrawing;
|
||||
using TBF.Rig.Generic;
|
||||
|
||||
namespace TBF.Rig.Modbus.UltrasoundLevelMeter
|
||||
{
|
||||
public class LevelMeterCfg : ComponentCfgBase, Generic.IChildComponentCfg, IParamsProvider
|
||||
public class LevelMeterCfg : ComponentCfgBase, IChildComponentCfg, IParamsProvider, IDrawingItemWithMeasuredVal
|
||||
{
|
||||
public static XmlSerializer Serializer = XmlSerializer.FromTypes(new[] { typeof(LevelMeterCfg) })[0];
|
||||
public override XmlSerializer GetSerializer() { return Serializer; }
|
||||
@@ -26,14 +24,42 @@ namespace TBF.Rig.Modbus.UltrasoundLevelMeter
|
||||
///
|
||||
/// Serialized parameters
|
||||
///
|
||||
public byte ModbusAddress; /// 1..247
|
||||
public int ModbusAddress; /// 0 (1..247)
|
||||
public double DefaultLevel; /// 1
|
||||
|
||||
/// Schematic drawing info
|
||||
public Shape Shape { get; set; }
|
||||
public int X { get; set; }
|
||||
public int Y { get; set; }
|
||||
public Sz Sz { get; set; }
|
||||
public Orient Orient { get; set; }
|
||||
public bool Flip { get; set; }
|
||||
public int LblX { get; set; }
|
||||
public int LblY { get; set; }
|
||||
public Orient LblOrient { get; set; }
|
||||
public int MsrdX { get; set; }
|
||||
public int MsrdY { get; set; }
|
||||
public Orient MsrdOrient { get; set; }
|
||||
|
||||
public string MsrdFormat { get; set; } /// 2
|
||||
public Unit MsrdUnit { get; set; } /// 3
|
||||
public double MsrdValLimLo { get; set; } /// 4
|
||||
public double MsrdValLimHi { get; set; } /// 5
|
||||
|
||||
[XmlIgnore]
|
||||
public IList<GNode> GNodes { get; set; }
|
||||
|
||||
/// Private parameterless constructor invoked by all other (public) constructors
|
||||
LevelMeterCfg() {}
|
||||
LevelMeterCfg()
|
||||
{
|
||||
GNodes = new List<GNode>();
|
||||
}
|
||||
|
||||
public LevelMeterCfg(IComponentFactory factory)
|
||||
: this()
|
||||
{
|
||||
Shape = Shape.TempM;
|
||||
Sz = Sz.M;
|
||||
Factory = factory;
|
||||
Name = "ULM";
|
||||
ParentName = "Modbus";
|
||||
@@ -45,74 +71,131 @@ namespace TBF.Rig.Modbus.UltrasoundLevelMeter
|
||||
public void InitializeAll()
|
||||
{
|
||||
ModbusAddress = 1;
|
||||
DefaultLevel = 1000.0;
|
||||
MsrdFormat = "{0:F0} mm";
|
||||
MsrdUnit = Unit.mm;
|
||||
MsrdValLimLo = 0;
|
||||
MsrdValLimHi = 5000;
|
||||
MsrdY = 22;
|
||||
}
|
||||
|
||||
|
||||
string[] paramNames = new string[]
|
||||
{
|
||||
"Modbus address",
|
||||
"Modbus address", /// 0
|
||||
"Default water level", /// 1
|
||||
"Display format", /// 2
|
||||
"Unit of water level", /// 3
|
||||
"Water level limit Lo", /// 4
|
||||
"Water level limit Hi", /// 5
|
||||
};
|
||||
public string ParamName(int i) { return paramNames[i]; }
|
||||
public int ParamsCount() { return paramNames.Length; }
|
||||
public ICollection<string> ParamValues(int i) { return null; }
|
||||
|
||||
public ICollection<string> ParamValues(int i)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 3:
|
||||
return new string[] { Unit.mm.ToDescription(),
|
||||
Unit.cm.ToDescription(),
|
||||
Unit.inch.ToDescription(),
|
||||
Unit.dm.ToDescription(),
|
||||
Unit.foot.ToDescription(),
|
||||
Unit.yard.ToDescription(),
|
||||
Unit.m.ToDescription() };
|
||||
default:
|
||||
return null;
|
||||
}
|
||||
}
|
||||
|
||||
public string ToString(int i)
|
||||
{
|
||||
if (i == -1)
|
||||
{
|
||||
return string.Format("ModbusAddr={0}", ModbusAddress);
|
||||
}
|
||||
|
||||
switch (i)
|
||||
{
|
||||
case 0: return ModbusAddress.ToString();
|
||||
default: return string.Empty;
|
||||
case 0: return ModbusAddress.ToString();
|
||||
case 1: return DefaultLevel.ToString();
|
||||
case 2: return MsrdFormat;
|
||||
case 3: return MsrdUnit.ToDescription();
|
||||
case 4: return MsrdValLimLo.ToString();
|
||||
case 5: return MsrdValLimHi.ToString();
|
||||
default:
|
||||
return string.Format("ModbusAddr={0}", ModbusAddress);
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
public CfgUpdateFlags UpdateParam(int i, string strValue)
|
||||
public CfgUpdateFlags UpdateParam(int i, string str)
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0:
|
||||
byte addr = byte.Parse(strValue);
|
||||
if (ModbusAddress != addr)
|
||||
{
|
||||
ModbusAddress = addr;
|
||||
return CfgUpdateFlags.RestartRqrd;
|
||||
}
|
||||
else
|
||||
{
|
||||
return CfgUpdateFlags.None;
|
||||
}
|
||||
|
||||
default:
|
||||
return CfgUpdateFlags.None;
|
||||
case 0: ModbusAddress = int.Parse(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 1: DefaultLevel = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 2: MsrdFormat = str; return CfgUpdateFlags.RestartRqrd;
|
||||
case 3: MsrdUnit = (str == Unit.m.ToDescription()) ? Unit.m
|
||||
: (str == Unit.cm.ToDescription()) ? Unit.cm
|
||||
: (str == Unit.inch.ToDescription()) ? Unit.inch
|
||||
: (str == Unit.dm.ToDescription()) ? Unit.dm
|
||||
: (str == Unit.foot.ToDescription()) ? Unit.foot
|
||||
: (str == Unit.yard.ToDescription()) ? Unit.yard
|
||||
: Unit.mm;
|
||||
return CfgUpdateFlags.RestartRqrd;
|
||||
case 4: MsrdValLimLo = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
case 5: MsrdValLimHi = Utils.ParseSDouble(str); return CfgUpdateFlags.RestartRqrd;
|
||||
default: return CfgUpdateFlags.None;
|
||||
}
|
||||
}
|
||||
|
||||
public bool ValidateParam(int i, string strValue, out string message)
|
||||
public bool ValidateParam(int i, string str, out string message)
|
||||
{
|
||||
message = string.Empty;
|
||||
int dummy;
|
||||
int idummy;
|
||||
double dummy;
|
||||
|
||||
switch (i)
|
||||
{
|
||||
case 0:
|
||||
if (int.TryParse(strValue, out dummy) && dummy >= 1 && dummy <= 247) return true;
|
||||
message = ParamName(i) + " is invalid. Address range is 1 .. 247";
|
||||
return false;
|
||||
if (int.TryParse(str, out idummy) && idummy >= 1 && idummy <= 254) return true;
|
||||
break;
|
||||
case 1:
|
||||
case 4:
|
||||
case 5:
|
||||
if (TBF.Utils.TryParseSDouble(str, out dummy)) return true;
|
||||
break;
|
||||
case 2:
|
||||
return true;
|
||||
case 3:
|
||||
if (ParamValues(i).Contains(str)) return true;
|
||||
break;
|
||||
default:
|
||||
message = "Invalid index";
|
||||
return false;
|
||||
}
|
||||
|
||||
message = ParamName(i) + " is invalid";
|
||||
return false;
|
||||
}
|
||||
|
||||
void CopyContentTo(LevelMeterCfg prms)
|
||||
{
|
||||
prms.ParentName = this.ParentName;
|
||||
prms.ModbusAddress = this.ModbusAddress;
|
||||
prms.DefaultLevel = this.DefaultLevel;
|
||||
prms.MsrdFormat = this.MsrdFormat;
|
||||
prms.MsrdUnit = this.MsrdUnit;
|
||||
prms.MsrdValLimLo = this.MsrdValLimLo;
|
||||
prms.MsrdValLimHi = this.MsrdValLimHi;
|
||||
|
||||
prms.ParentName = this.ParentName;
|
||||
prms.Shape = this.Shape;
|
||||
prms.Sz = this.Sz;
|
||||
prms.Orient = this.Orient;
|
||||
prms.Flip = this.Flip;
|
||||
prms.LblX = this.LblX;
|
||||
prms.LblY = this.LblY;
|
||||
prms.LblOrient = this.LblOrient;
|
||||
prms.MsrdX = this.MsrdX;
|
||||
prms.MsrdY = this.MsrdY;
|
||||
prms.MsrdOrient = this.MsrdOrient;
|
||||
}
|
||||
|
||||
|
||||
|
||||
Reference in New Issue
Block a user