ErrorLimitHi, ErrorLimitLo, EvaluateVolume test parameters added to all heat meters methods.
This commit is contained in:
@@ -13,10 +13,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStart.HeatMeters
|
||||
{
|
||||
public class TestParams : TestParamsBase, IParamsProvider, ITestParams
|
||||
{
|
||||
public float TempWarmLo; /// Low limit for warm temperature [C]
|
||||
public float TempWarmHi; /// High limit for warm temperature [C]
|
||||
public float TempColdLo; /// Low limit for cold temperature [C]
|
||||
public float TempColdHi; /// High limit for cold temperature [C]
|
||||
public float ErrorLimitLo; /// [%]
|
||||
public float ErrorLimitHi; /// [%]
|
||||
public bool EvaluateVolume; /// true = evaluate also the volume, false = evaluate only energy
|
||||
public float TempWarmLo; /// Low limit for warm temperature [°C]
|
||||
public float TempWarmHi; /// High limit for warm temperature [°C]
|
||||
public float TempColdLo; /// Low limit for cold temperature [°C]
|
||||
public float TempColdHi; /// High limit for cold temperature [°C]
|
||||
public bool FlowMeasuredAtHiTempPipe; /// true = flow measured at high temp. pipe, false = flow measured at low temp. pipe
|
||||
public float DeltaTempWarm;
|
||||
public float DeltaTempCold;
|
||||
@@ -32,6 +35,9 @@ namespace TBF.BenchControl.TestMethods.FlyingStart.HeatMeters
|
||||
|
||||
string[] paramNames = new string[]
|
||||
{
|
||||
Strings.Err_limit_neg_pct_chdr,
|
||||
Strings.Err_limit_pos_pct_chdr,
|
||||
Strings.Evaluate_volume,
|
||||
"T warm lo",
|
||||
"T warm hi",
|
||||
"T cold lo",
|
||||
@@ -50,16 +56,19 @@ namespace TBF.BenchControl.TestMethods.FlyingStart.HeatMeters
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0: return TempWarmLo.ToString();
|
||||
case 1: return TempWarmHi.ToString();
|
||||
case 2: return TempColdLo.ToString();
|
||||
case 3: return TempColdHi.ToString();
|
||||
case 4: return (FlowMeasuredAtHiTempPipe ? Strings.yes : Strings.no);
|
||||
case 5: return DeltaTempWarm.ToString();
|
||||
case 6: return DeltaTempCold.ToString();
|
||||
case 7: return ChangeInTimeWarm.ToString();
|
||||
case 8: return ChangeInTimeCold.ToString();
|
||||
case 9: return Prompt;
|
||||
case 0: return ErrorLimitLo.ToString();
|
||||
case 1: return ErrorLimitHi.ToString();
|
||||
case 2: return (EvaluateVolume ? Strings.yes : Strings.no);
|
||||
case 3: return TempWarmLo.ToString();
|
||||
case 4: return TempWarmHi.ToString();
|
||||
case 5: return TempColdLo.ToString();
|
||||
case 6: return TempColdHi.ToString();
|
||||
case 7: return (FlowMeasuredAtHiTempPipe ? Strings.yes : Strings.no);
|
||||
case 8: return DeltaTempWarm.ToString();
|
||||
case 9: return DeltaTempCold.ToString();
|
||||
case 10: return ChangeInTimeWarm.ToString();
|
||||
case 11: return ChangeInTimeCold.ToString();
|
||||
case 12: return Prompt;
|
||||
default: return string.Empty;
|
||||
}
|
||||
}
|
||||
@@ -68,16 +77,19 @@ namespace TBF.BenchControl.TestMethods.FlyingStart.HeatMeters
|
||||
{
|
||||
switch (i)
|
||||
{
|
||||
case 0: TempWarmLo = Utils.ParseSFloat(strValue); return;
|
||||
case 1: TempWarmHi = Utils.ParseSFloat(strValue); return;
|
||||
case 2: TempColdLo = Utils.ParseSFloat(strValue); return;
|
||||
case 3: TempColdHi = Utils.ParseSFloat(strValue); return;
|
||||
case 4: FlowMeasuredAtHiTempPipe = strValue.Equals(Strings.yes); return;
|
||||
case 5: DeltaTempWarm = Utils.ParseUFloat(strValue); return;
|
||||
case 6: DeltaTempCold = Utils.ParseUFloat(strValue); return;
|
||||
case 7: ChangeInTimeWarm = Utils.ParseUFloat(strValue); return;
|
||||
case 8: ChangeInTimeCold = Utils.ParseUFloat(strValue); return;
|
||||
case 9: Prompt = strValue; return;
|
||||
case 0: ErrorLimitLo = Utils.ParseSFloat(strValue); return;
|
||||
case 1: ErrorLimitHi = Utils.ParseSFloat(strValue); return;
|
||||
case 2: EvaluateVolume = strValue.Equals(Strings.yes); return;
|
||||
case 3: TempWarmLo = Utils.ParseSFloat(strValue); return;
|
||||
case 4: TempWarmHi = Utils.ParseSFloat(strValue); return;
|
||||
case 5: TempColdLo = Utils.ParseSFloat(strValue); return;
|
||||
case 6: TempColdHi = Utils.ParseSFloat(strValue); return;
|
||||
case 7: FlowMeasuredAtHiTempPipe = strValue.Equals(Strings.yes); return;
|
||||
case 8: DeltaTempWarm = Utils.ParseUFloat(strValue); return;
|
||||
case 9: DeltaTempCold = Utils.ParseUFloat(strValue); return;
|
||||
case 10: ChangeInTimeWarm = Utils.ParseUFloat(strValue); return;
|
||||
case 11: ChangeInTimeCold = Utils.ParseUFloat(strValue); return;
|
||||
case 12: Prompt = strValue; return;
|
||||
default: return;
|
||||
}
|
||||
}
|
||||
@@ -91,20 +103,23 @@ namespace TBF.BenchControl.TestMethods.FlyingStart.HeatMeters
|
||||
{
|
||||
case 0:
|
||||
case 1:
|
||||
case 2:
|
||||
case 3:
|
||||
if (Utils.TryParseSFloat(strValue, out dummy)) return true;
|
||||
break;
|
||||
case 4:
|
||||
if (strValue.Equals(Strings.yes) || strValue.Equals(Strings.no)) return true;
|
||||
break;
|
||||
case 5:
|
||||
case 6:
|
||||
if (Utils.TryParseSFloat(strValue, out dummy)) return true;
|
||||
break;
|
||||
case 2:
|
||||
case 7:
|
||||
if (strValue.Equals(Strings.yes) || strValue.Equals(Strings.no)) return true;
|
||||
break;
|
||||
case 8:
|
||||
case 9:
|
||||
case 10:
|
||||
case 11:
|
||||
if (Utils.TryParseUFloat(strValue, out dummy)) return true;
|
||||
break;
|
||||
case 9:
|
||||
case 12:
|
||||
return true;
|
||||
default:
|
||||
message = "Invalid index";
|
||||
@@ -117,6 +132,9 @@ namespace TBF.BenchControl.TestMethods.FlyingStart.HeatMeters
|
||||
|
||||
void CopyContentTo(TestParams prms)
|
||||
{
|
||||
prms.ErrorLimitLo = ErrorLimitLo;
|
||||
prms.ErrorLimitHi = ErrorLimitHi;
|
||||
prms.EvaluateVolume = EvaluateVolume;
|
||||
prms.TempWarmLo = TempWarmLo;
|
||||
prms.TempWarmHi = TempWarmHi;
|
||||
prms.TempColdLo = TempColdLo;
|
||||
|
||||
Reference in New Issue