Results.Entities.TestRslt.TestTimeCorrection added and used in test methods with diverter.
This commit is contained in:
@@ -667,6 +667,12 @@ namespace TBF.BenchControl.TestMethods.CombinedWithDetection
|
||||
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * cBrd.EtPulses(0) / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.Buoyancy = Config.Formulas.Buoyancy();
|
||||
tstRslt.VolumeCTV = 1000 * tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.DensityLine; /// [l] commercially true volume
|
||||
if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon))
|
||||
{
|
||||
tstRslt.TestTimeCorrection = outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume);
|
||||
tstRslt.VolumeCTV *= tstRslt.TestTime + tstRslt.TestTimeCorrection;
|
||||
tstRslt.VolumeCTV /= tstRslt.TestTime;
|
||||
}
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
||||
|
||||
+6
@@ -734,6 +734,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartFirstRepetWithMassColl
|
||||
tstRslt.MassEnd = Config.Formulas.CorrectedValue(tstRslt.MassEndRaw, scale.Corrections);
|
||||
tstRslt.FlowMass = 3600 * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.TestTime; /// [kg/h]
|
||||
tstRslt.VolumeCTV = 1000 * tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.DensityLine; /// [l] commercially true volume
|
||||
if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon))
|
||||
{
|
||||
tstRslt.TestTimeCorrection = outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume);
|
||||
tstRslt.VolumeCTV *= tstRslt.TestTime + tstRslt.TestTimeCorrection;
|
||||
tstRslt.VolumeCTV /= tstRslt.TestTime;
|
||||
}
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
||||
|
||||
+7
-1
@@ -825,7 +825,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollComparative
|
||||
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.Buoyancy = Config.Formulas.Buoyancy();
|
||||
tstRslt.VolumeCTV = 1000 * tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.DensityLine; /// [l] commercially true volume
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon))
|
||||
{
|
||||
tstRslt.TestTimeCorrection = outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume);
|
||||
tstRslt.VolumeCTV *= tstRslt.TestTime + tstRslt.TestTimeCorrection;
|
||||
tstRslt.VolumeCTV /= tstRslt.TestTime;
|
||||
}
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
||||
tstRslt.ConstMaster = (tstRslt.VolumeMaster == 0) ? tstRslt.ConstMasterCorr : (LtrPerRefPulse * tstRslt.VolumeCTV / tstRslt.VolumeMaster);
|
||||
|
||||
+7
-1
@@ -744,7 +744,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollProlonged
|
||||
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * totalPulses / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.Buoyancy = Formulas.Buoyancy();
|
||||
tstRslt.VolumeCTV = 1000 * tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.DensityLine; /// [l] commercially true volume of collected water
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon))
|
||||
{
|
||||
tstRslt.TestTimeCorrection = outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume);
|
||||
tstRslt.VolumeCTV *= tstRslt.TestTime + tstRslt.TestTimeCorrection;
|
||||
tstRslt.VolumeCTV /= tstRslt.TestTime;
|
||||
}
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
||||
tstRslt.ConstMaster = (massPulses == 0) ? tstRslt.ConstMasterCorr : (tstRslt.VolumeCTV / massPulses);
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * massPulses; /// [l] volume from the master flow meter
|
||||
|
||||
@@ -732,6 +732,12 @@ namespace TBF.BenchControl.TestMethods.FlyingStartMassCollection
|
||||
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.Buoyancy = Config.Formulas.Buoyancy();
|
||||
tstRslt.VolumeCTV = 1000 * tstRslt.Buoyancy * (tstRslt.MassEnd - tstRslt.MassStart) / tstRslt.DensityLine; /// [l] commercially true volume
|
||||
if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon))
|
||||
{
|
||||
tstRslt.TestTimeCorrection = outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume);
|
||||
tstRslt.VolumeCTV *= tstRslt.TestTime + tstRslt.TestTimeCorrection;
|
||||
tstRslt.VolumeCTV /= tstRslt.TestTime;
|
||||
}
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
||||
|
||||
+7
-1
@@ -494,7 +494,13 @@ namespace TBF.BenchControl.TestMethods.FlyingStartTankCollection
|
||||
tstRslt.FlowVolume = 3.6 * LtrPerRefPulse * tstRslt.PulsesMaster / tstRslt.TestTime; /// [m3/h]
|
||||
tstRslt.Buoyancy = 0;
|
||||
tstRslt.VolumeCTV = volumeBox.Val; /// [l]
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
if ((outPath.Diverter != null) && (tstRslt.TestTime > float.Epsilon))
|
||||
{
|
||||
tstRslt.TestTimeCorrection = outPath.Diverter.TestTimeCorrection(tstRslt.FlowVolume);
|
||||
tstRslt.VolumeCTV *= tstRslt.TestTime + tstRslt.TestTimeCorrection;
|
||||
tstRslt.VolumeCTV /= tstRslt.TestTime;
|
||||
}
|
||||
tstRslt.VolumeMaster = LtrPerRefPulse * tstRslt.PulsesMaster; /// [l] volume from the master flow meter
|
||||
tstRslt.ConstMasterRaw = outPath.FlowMeter.LtrPerPulse; /// Uncorrected master flowmeter coefficient
|
||||
tstRslt.ConstMasterCorr = outPath.FlowMeter.LtrPerPulseCorrected(tstRslt.FlowVolume, rangeIx); /// Corrected master pulses per liter
|
||||
tstRslt.ConstMaster = (tstRslt.VolumeMaster == 0) ? tstRslt.ConstMasterCorr : (LtrPerRefPulse * tstRslt.VolumeCTV / tstRslt.VolumeMaster);
|
||||
|
||||
Reference in New Issue