RegulValveTandem op SetFlowOp should be functional, to be tested

This commit is contained in:
Milan Hanajik
2015-02-03 10:30:24 +01:00
parent ab8aa61a29
commit 5806a65a0c
10 changed files with 139 additions and 99 deletions
@@ -16,15 +16,10 @@ namespace TBF.BenchControl.Elde.RegulValveTandem
///
public string RegulValveName; /// Name of the regulation valve used to control the flow
public string FixedRVName; /// Name of the regulation valve with a fixed position
public int StableTimeMs; /// 200..1500 ms
public float FixedRVPosition; /// Fixed RV position 0 .. 100 in [%]
public bool StoredPositionReuse; /// true = store and re-use previous regulation valve positions
public int FlowStableSec; /// 0..60 sec
/// <summary>
/// Stabilization time when setting the flow: 0=200ms, step 50ms, max. 1.5 sec.
/// </summary>
public int StableTime { get { return (StableTimeMs - 200) / 50; } }
/// Private parameterless constructor invoked by all other (public) constructors
RegulValveTandemCfg()
{
@@ -34,7 +29,7 @@ namespace TBF.BenchControl.Elde.RegulValveTandem
RegulValveName = "RV1";
FixedRVName = "RV2";
StableTimeMs = 500;
FixedRVPosition = 50.0f;
StoredPositionReuse = false;
FlowStableSec = 5;
}
@@ -47,11 +42,11 @@ namespace TBF.BenchControl.Elde.RegulValveTandem
public string ToString(int i)
{
return string.Format("Name={0}, ControlledRVName={1}, ADC-FixedRVName={2}, StabTm={3}ms, PosReuse={4}, FlowStable={5}s",
return string.Format("Name={0}, RegulVName={1}, FixedRVName={2}, FixedRVPos={3}%, PosReuse={4}, FlowStable={5}s",
Name,
RegulValveName,
FixedRVName,
StableTimeMs,
FixedRVPosition.ToString("F0"),
StoredPositionReuse,
FlowStableSec);
}